Skip to main content
Erschienen in: European Radiology 5/2010

01.05.2010 | Cardiac

Automated computer-aided stenosis detection at coronary CT angiography: initial experience

verfasst von: Elisabeth Arnoldi, Mulugeta Gebregziabher, U. Joseph Schoepf, Roman Goldenberg, Luis Ramos-Duran, Peter L. Zwerner, Konstantin Nikolaou, Maximilian F. Reiser, Philip Costello, Christian Thilo

Erschienen in: European Radiology | Ausgabe 5/2010

Einloggen, um Zugang zu erhalten

Abstract

Objective

To evaluate the performance of a computer-aided algorithm for automated stenosis detection at coronary CT angiography (cCTA).

Methods

We investigated 59 patients (38 men, mean age 58 ± 12 years) who underwent cCTA and quantitative coronary angiography (QCA). All cCTA data sets were analyzed using a software algorithm for automated, without human interaction, detection of coronary artery stenosis. The performance of the algorithm for detection of stenosis of 50% or more was compared with QCA.

Results

QCA revealed a total of 38 stenoses of 50% or more of which the algorithm correctly identified 28 (74%). Overall, the automated detection algorithm had 74%/100% sensitivity, 83%/65% specificity, 46%/58% positive predictive value, and 94%/100% negative predictive value for diagnosing stenosis of 50% or more on per-vessel/per-patient analysis, respectively. There were 33 false positive detection marks (average 0.56/patient), of which 19 were associated with stenotic lesions of less than 50% on QCA and 14 were not associated with an atherosclerotic surrogate.

Conclusion

Compared with QCA, the automated detection algorithm evaluated has relatively high accuracy for diagnosing significant coronary artery stenosis at cCTA. If used as a second reader, the high negative predictive value may further enhance the confidence of excluding significant stenosis based on a normal or near-normal cCTA study.
Literatur
1.
Zurück zum Zitat Pugliese F, Hunink MG, Gruszczynska K et al (2009) Learning curve for coronary CT angiography: what constitutes sufficient training? Radiology 251:359–368CrossRefPubMed Pugliese F, Hunink MG, Gruszczynska K et al (2009) Learning curve for coronary CT angiography: what constitutes sufficient training? Radiology 251:359–368CrossRefPubMed
2.
Zurück zum Zitat Choi HS, Choi BW, Choe KO et al (2004) Pitfalls, artifacts, and remedies in multi-detector row CT coronary angiography. Radiographics 24:787–800CrossRefPubMed Choi HS, Choi BW, Choe KO et al (2004) Pitfalls, artifacts, and remedies in multi-detector row CT coronary angiography. Radiographics 24:787–800CrossRefPubMed
3.
Zurück zum Zitat Hoe JW, Toh KH (2007) A practical guide to reading CT coronary angiograms—how to avoid mistakes when assessing for coronary stenoses. Int J Cardiovasc Imaging 23:617–633CrossRefPubMed Hoe JW, Toh KH (2007) A practical guide to reading CT coronary angiograms—how to avoid mistakes when assessing for coronary stenoses. Int J Cardiovasc Imaging 23:617–633CrossRefPubMed
4.
Zurück zum Zitat Nakanishi T, Kayashima Y, Inoue R, Sumii K, Gomyo Y (2005) Pitfalls in 16-detector row CT of the coronary arteries. Radiographics 25:425–438CrossRefPubMed Nakanishi T, Kayashima Y, Inoue R, Sumii K, Gomyo Y (2005) Pitfalls in 16-detector row CT of the coronary arteries. Radiographics 25:425–438CrossRefPubMed
5.
Zurück zum Zitat Wormanns D, Fiebich M, Saidi M, Diederich S, Heindel W (2002) Automatic detection of pulmonary nodules at spiral CT: clinical application of a computer-aided diagnosis system. Eur Radiol 12:1052–1057CrossRefPubMed Wormanns D, Fiebich M, Saidi M, Diederich S, Heindel W (2002) Automatic detection of pulmonary nodules at spiral CT: clinical application of a computer-aided diagnosis system. Eur Radiol 12:1052–1057CrossRefPubMed
6.
Zurück zum Zitat de Vries AH, Jensch S, Liedenbaum MH et al (2007) Does a computer-aided detection algorithm in a second read paradigm enhance the performance of experienced computed tomography colonography readers in a population of increased risk? Eur Radiol 19:941–950CrossRef de Vries AH, Jensch S, Liedenbaum MH et al (2007) Does a computer-aided detection algorithm in a second read paradigm enhance the performance of experienced computed tomography colonography readers in a population of increased risk? Eur Radiol 19:941–950CrossRef
7.
Zurück zum Zitat Das M, Muhlenbruch G, Helm A et al (2008) Computer-aided detection of pulmonary embolism: influence on radiologists’ detection performance with respect to vessel segments. Eur Radiol 18:1350–1355CrossRefPubMed Das M, Muhlenbruch G, Helm A et al (2008) Computer-aided detection of pulmonary embolism: influence on radiologists’ detection performance with respect to vessel segments. Eur Radiol 18:1350–1355CrossRefPubMed
8.
Zurück zum Zitat Tanaka T, Nitta N, Ohta S et al (2009) Evaluation of computer-aided detection of lesions in mammograms obtained with a digital phase-contrast mammography system. Eur Radiol. doi:10.1007/s00330-009-1505-4 Tanaka T, Nitta N, Ohta S et al (2009) Evaluation of computer-aided detection of lesions in mammograms obtained with a digital phase-contrast mammography system. Eur Radiol. doi:10.​1007/​s00330-009-1505-4
9.
Zurück zum Zitat Koss LG, Sherman ME, Cohen MB et al (1997) Significant reduction in the rate of false-negative cervical smears with neural network-based technology (PAPNET Testing System). Hum Pathol 28:1196–1203CrossRefPubMed Koss LG, Sherman ME, Cohen MB et al (1997) Significant reduction in the rate of false-negative cervical smears with neural network-based technology (PAPNET Testing System). Hum Pathol 28:1196–1203CrossRefPubMed
10.
Zurück zum Zitat Sugahara T, Yamagihara Y, Sugimoto N, Kimura K, Awano K, Azumi T (1992) Computer-aided interpretation of coronary cineangiograms. Accuracy of automatic detection of stenotic lesions. Acta Radiol 33:6–9PubMed Sugahara T, Yamagihara Y, Sugimoto N, Kimura K, Awano K, Azumi T (1992) Computer-aided interpretation of coronary cineangiograms. Accuracy of automatic detection of stenotic lesions. Acta Radiol 33:6–9PubMed
11.
Zurück zum Zitat Isgum I, Rutten A, Prokop M, van Ginneken B (2007) Detection of coronary calcifications from computed tomography scans for automated risk assessment of coronary artery disease. Med Phys 34:1450–1461CrossRefPubMed Isgum I, Rutten A, Prokop M, van Ginneken B (2007) Detection of coronary calcifications from computed tomography scans for automated risk assessment of coronary artery disease. Med Phys 34:1450–1461CrossRefPubMed
12.
Zurück zum Zitat Reimann AJ, Tsiflikas I, Brodoefel H et al (2009) Efficacy of computer aided analysis in detection of significant coronary artery stenosis in cardiac using dual source computed tomography. Int J Cardiovasc Imaging 25:195–203CrossRefPubMed Reimann AJ, Tsiflikas I, Brodoefel H et al (2009) Efficacy of computer aided analysis in detection of significant coronary artery stenosis in cardiac using dual source computed tomography. Int J Cardiovasc Imaging 25:195–203CrossRefPubMed
13.
Zurück zum Zitat Das M, Muhlenbruch G, Mahnken AH et al (2006) Small pulmonary nodules: effect of two computer-aided detection systems on radiologist performance. Radiology 241:564–571CrossRefPubMed Das M, Muhlenbruch G, Mahnken AH et al (2006) Small pulmonary nodules: effect of two computer-aided detection systems on radiologist performance. Radiology 241:564–571CrossRefPubMed
14.
Zurück zum Zitat Schoepf UJ, Schneider AC, Das M, Wood SA, Cheema JI, Costello P (2007) Pulmonary embolism: computer-aided detection at multidetector row spiral computed tomography. J Thorac Imaging 22:319–323CrossRefPubMed Schoepf UJ, Schneider AC, Das M, Wood SA, Cheema JI, Costello P (2007) Pulmonary embolism: computer-aided detection at multidetector row spiral computed tomography. J Thorac Imaging 22:319–323CrossRefPubMed
15.
Zurück zum Zitat Zhou C, Chan HP, Patel S et al (2005) Preliminary investigation of computer-aided detection of pulmonary embolism in three-dimensional computed tomography pulmonary angiography images. Acad Radiol 12:782–792CrossRefPubMed Zhou C, Chan HP, Patel S et al (2005) Preliminary investigation of computer-aided detection of pulmonary embolism in three-dimensional computed tomography pulmonary angiography images. Acad Radiol 12:782–792CrossRefPubMed
16.
Zurück zum Zitat Summers RM, Johnson CD, Pusanik LM, Malley JD, Youssef AM, Reed JE (2001) Automated polyp detection at CT colonography: feasibility assessment in a human population. Radiology 219:51–59PubMed Summers RM, Johnson CD, Pusanik LM, Malley JD, Youssef AM, Reed JE (2001) Automated polyp detection at CT colonography: feasibility assessment in a human population. Radiology 219:51–59PubMed
17.
Zurück zum Zitat Taylor SA, Iinuma G, Saito Y, Zhang J, Halligan S (2008) CT colonography: computer-aided detection of morphologically flat T1 colonic carcinoma. Eur Radiol 18:1666–1673CrossRefPubMed Taylor SA, Iinuma G, Saito Y, Zhang J, Halligan S (2008) CT colonography: computer-aided detection of morphologically flat T1 colonic carcinoma. Eur Radiol 18:1666–1673CrossRefPubMed
18.
Zurück zum Zitat Hamon M, Morello R, Riddell JW (2007) Coronary arteries: diagnostic performance of 16-versus 64-section spiral CT compared with invasive coronary angiography—meta-analysis. Radiology 245:720–731CrossRefPubMed Hamon M, Morello R, Riddell JW (2007) Coronary arteries: diagnostic performance of 16-versus 64-section spiral CT compared with invasive coronary angiography—meta-analysis. Radiology 245:720–731CrossRefPubMed
19.
Zurück zum Zitat Hendel RC, Patel MR, Kramer CM et al (2006) ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging: a report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group, American College of Radiology, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, American Society of Nuclear Cardiology, North American Society for Cardiac Imaging, Society for Cardiovascular Angiography and Interventions, and Society of Interventional Radiology. J Am Coll Cardiol 48:1475–1497CrossRefPubMed Hendel RC, Patel MR, Kramer CM et al (2006) ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging: a report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group, American College of Radiology, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, American Society of Nuclear Cardiology, North American Society for Cardiac Imaging, Society for Cardiovascular Angiography and Interventions, and Society of Interventional Radiology. J Am Coll Cardiol 48:1475–1497CrossRefPubMed
20.
Zurück zum Zitat Hoffmann U, Nagurney JT, Moselewski F et al (2006) Coronary multidetector computed tomography in the assessment of patients with acute chest pain. Circulation 114:2251–2260CrossRefPubMed Hoffmann U, Nagurney JT, Moselewski F et al (2006) Coronary multidetector computed tomography in the assessment of patients with acute chest pain. Circulation 114:2251–2260CrossRefPubMed
21.
Zurück zum Zitat Hoffmann U, Bamberg F, Chae CU et al (2009) Coronary computed tomography angiography for early triage of patients with acute chest pain: the ROMICAT (Rule Out Myocardial Infarction using Computer Assisted Tomography) trial. J Am Coll Cardiol 53:1642–1650CrossRefPubMed Hoffmann U, Bamberg F, Chae CU et al (2009) Coronary computed tomography angiography for early triage of patients with acute chest pain: the ROMICAT (Rule Out Myocardial Infarction using Computer Assisted Tomography) trial. J Am Coll Cardiol 53:1642–1650CrossRefPubMed
22.
Zurück zum Zitat Sato Y, Matsumoto N, Ichikawa M, Kunimasa T et al (2005) Efficacy of multislice computed tomography for the detection of acute coronary syndrome in the emergency department. Circ J 69:1047–1051CrossRefPubMed Sato Y, Matsumoto N, Ichikawa M, Kunimasa T et al (2005) Efficacy of multislice computed tomography for the detection of acute coronary syndrome in the emergency department. Circ J 69:1047–1051CrossRefPubMed
23.
Zurück zum Zitat Arnoldi E, Johnson TR, Rist C et al (2009) Adequate image quality with reduced radiation dose in prospectively triggered coronary CTA compared with retrospective techniques. Eur Radiol. doi:10.1007/s00330-009-1411-9 Arnoldi E, Johnson TR, Rist C et al (2009) Adequate image quality with reduced radiation dose in prospectively triggered coronary CTA compared with retrospective techniques. Eur Radiol. doi:10.​1007/​s00330-009-1411-9
24.
Zurück zum Zitat Achenbach S, Marwan M, Schepis T et al (2009) High-pitch spiral acquisition: a new scan mode for coronary CT angiography. J Cardiovasc Comput Tomogr 3:117–121CrossRefPubMed Achenbach S, Marwan M, Schepis T et al (2009) High-pitch spiral acquisition: a new scan mode for coronary CT angiography. J Cardiovasc Comput Tomogr 3:117–121CrossRefPubMed
Metadaten
Titel
Automated computer-aided stenosis detection at coronary CT angiography: initial experience
verfasst von
Elisabeth Arnoldi
Mulugeta Gebregziabher
U. Joseph Schoepf
Roman Goldenberg
Luis Ramos-Duran
Peter L. Zwerner
Konstantin Nikolaou
Maximilian F. Reiser
Philip Costello
Christian Thilo
Publikationsdatum
01.05.2010
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 5/2010
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-009-1644-7

Weitere Artikel der Ausgabe 5/2010

European Radiology 5/2010 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.