Skip to main content
Erschienen in: European Radiology 11/2010

01.11.2010 | Cardiac

High-pitch dual-source CT coronary angiography: systolic data acquisition at high heart rates

verfasst von: Robert Goetti, Gudrun Feuchtner, Paul Stolzmann, Lotus Desbiolles, Michael Alexander Fischer, Christoph Karlo, Stephan Baumueller, Hans Scheffel, Hatem Alkadhi, Sebastian Leschka

Erschienen in: European Radiology | Ausgabe 11/2010

Einloggen, um Zugang zu erhalten

Abstract

Objective

To assess the effect of systolic data acquisition for electrocardiography (ECG)-triggered high-pitch computed tomography (CT) on motion artefacts of coronary arteries in patients with high heart rates (HRs).

Methods

Eighty consecutive patients (15 women, age 67 ± 14 years) with HR ≥70 bpm underwent CT angiography of the thoracic aorta (CTA) on 128-slice dual-source CT in ECG-triggered high-pitch acquisition mode (pitch = 3.2) set at 60% (group A, n = 40) or 30% (group B, n = 40) of the RR interval. Two blinded readers graded coronary artery image quality on a three-point scale. Radiation doses were calculated.

Results

Inter-observer agreement in grading image quality of the 1,154 coronary segments was good (κ = 0.62). HRs were similar in groups A and B (85 ± 13 bpm vs 85 ± 14 bpm, p not significant). Significantly fewer coronary segments with non-diagnostic image quality occurred (i.e. score 3) in group B than in group A [2.8% (16/579) vs 8.3% (48/575), p < 0.001]. Seventeen patients (42.5%) of group A and 12 patients (30.0%) of group B had at least one non-diagnostic segment. Effective radiation doses were 2.3 ± 0.3 mSv for chest CTA.

Conclusion

A systolic acquisition window for high-pitch dual-source CTA in patients with high HRs (≥70 bpm) significantly improves coronary artery image quality at a low radiation dose.
Literatur
1.
Zurück zum Zitat Raff GL, Gallagher MJ, O’Neill WW, Goldstein JA (2005) Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 46:552–557CrossRefPubMed Raff GL, Gallagher MJ, O’Neill WW, Goldstein JA (2005) Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 46:552–557CrossRefPubMed
2.
Zurück zum Zitat Scheffel H, Alkadhi H, Plass A et al (2006) Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control. Eur Radiol 16:2739–2747CrossRefPubMed Scheffel H, Alkadhi H, Plass A et al (2006) Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control. Eur Radiol 16:2739–2747CrossRefPubMed
3.
Zurück zum Zitat Weustink AC, Meijboom WB, Mollet NR et al (2007) Reliable high-speed coronary computed tomography in symptomatic patients. J Am Coll Cardiol 50:786–794CrossRefPubMed Weustink AC, Meijboom WB, Mollet NR et al (2007) Reliable high-speed coronary computed tomography in symptomatic patients. J Am Coll Cardiol 50:786–794CrossRefPubMed
4.
Zurück zum Zitat Johnson TR, Nikolaou K, Busch S et al (2007) Diagnostic accuracy of dual-source computed tomography in the diagnosis of coronary artery disease. Invest radiol 42:684–691CrossRefPubMed Johnson TR, Nikolaou K, Busch S et al (2007) Diagnostic accuracy of dual-source computed tomography in the diagnosis of coronary artery disease. Invest radiol 42:684–691CrossRefPubMed
5.
Zurück zum Zitat Ropers U, Ropers D, Pflederer T et al (2007) Influence of heart rate on the diagnostic accuracy of dual-source computed tomography coronary angiography. J Am Coll Cardiol 50:2393–2398CrossRefPubMed Ropers U, Ropers D, Pflederer T et al (2007) Influence of heart rate on the diagnostic accuracy of dual-source computed tomography coronary angiography. J Am Coll Cardiol 50:2393–2398CrossRefPubMed
6.
Zurück zum Zitat Leschka S, Stolzmann P, Desbiolles L et al (2009) Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience. Eur Radiol 19:2896–2903CrossRefPubMed Leschka S, Stolzmann P, Desbiolles L et al (2009) Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience. Eur Radiol 19:2896–2903CrossRefPubMed
7.
Zurück zum Zitat Nieman K, Rensing BJ, van Geuns RJ et al (2002) Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rate. Heart 88:470–474CrossRefPubMed Nieman K, Rensing BJ, van Geuns RJ et al (2002) Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rate. Heart 88:470–474CrossRefPubMed
8.
Zurück zum Zitat Hoffmann MH, Shi H, Manzke R et al (2005) Noninvasive coronary angiography with 16-detector row CT: effect of heart rate. Radiology 234:86–97CrossRefPubMed Hoffmann MH, Shi H, Manzke R et al (2005) Noninvasive coronary angiography with 16-detector row CT: effect of heart rate. Radiology 234:86–97CrossRefPubMed
9.
Zurück zum Zitat Achenbach S, Ropers D, Holle J, Muschiol G, Daniel WG, Moshage W (2000) In-plane coronary arterial motion velocity: measurement with electron-beam CT. Radiology 216:457–463PubMed Achenbach S, Ropers D, Holle J, Muschiol G, Daniel WG, Moshage W (2000) In-plane coronary arterial motion velocity: measurement with electron-beam CT. Radiology 216:457–463PubMed
10.
Zurück zum Zitat Chung CS, Karamanoglu M, Kovacs SJ (2004) Duration of diastole and its phases as a function of heart rate during supine bicycle exercise. Am J Physiol Heart Circ Physiol 287:H2003–H2008CrossRefPubMed Chung CS, Karamanoglu M, Kovacs SJ (2004) Duration of diastole and its phases as a function of heart rate during supine bicycle exercise. Am J Physiol Heart Circ Physiol 287:H2003–H2008CrossRefPubMed
11.
Zurück zum Zitat Herzog C, Arning-Erb M, Zangos S et al (2006) Multi-detector row CT coronary angiography: influence of reconstruction technique and heart rate on image quality. Radiology 238:75–86CrossRefPubMed Herzog C, Arning-Erb M, Zangos S et al (2006) Multi-detector row CT coronary angiography: influence of reconstruction technique and heart rate on image quality. Radiology 238:75–86CrossRefPubMed
12.
Zurück zum Zitat Wintersperger BJ, Nikolaou K, von Ziegler F et al (2006) Image quality, motion artifacts, and reconstruction timing of 64-slice coronary computed tomography angiography with 0.33-second rotation speed. Invest radiol 41:436–442CrossRefPubMed Wintersperger BJ, Nikolaou K, von Ziegler F et al (2006) Image quality, motion artifacts, and reconstruction timing of 64-slice coronary computed tomography angiography with 0.33-second rotation speed. Invest radiol 41:436–442CrossRefPubMed
13.
Zurück zum Zitat Leschka S, Wildermuth S, Boehm T et al (2006) Noninvasive coronary angiography with 64-section CT: effect of average heart rate and heart rate variability on image quality. Radiology 241:378–385CrossRefPubMed Leschka S, Wildermuth S, Boehm T et al (2006) Noninvasive coronary angiography with 64-section CT: effect of average heart rate and heart rate variability on image quality. Radiology 241:378–385CrossRefPubMed
14.
Zurück zum Zitat Weustink AC, Mollet NR, Pugliese F et al (2008) Optimal electrocardiographic pulsing windows and heart rate: effect on image quality and radiation exposure at dual-source coronary CT angiography. Radiology 248:792–798CrossRefPubMed Weustink AC, Mollet NR, Pugliese F et al (2008) Optimal electrocardiographic pulsing windows and heart rate: effect on image quality and radiation exposure at dual-source coronary CT angiography. Radiology 248:792–798CrossRefPubMed
15.
Zurück zum Zitat Seifarth H, Wienbeck S, Pusken M et al (2007) Optimal systolic and diastolic reconstruction windows for coronary CT angiography using dual-source CT. AJR Am J Roentgenol 189:1317–1323CrossRefPubMed Seifarth H, Wienbeck S, Pusken M et al (2007) Optimal systolic and diastolic reconstruction windows for coronary CT angiography using dual-source CT. AJR Am J Roentgenol 189:1317–1323CrossRefPubMed
16.
Zurück zum Zitat Araoz PA, Kirsch J, Primak AN et al (2009) Optimal image reconstruction phase at low and high heart rates in dual-source CT coronary angiography. Int J Cardiovasc Imaging 25:837–845CrossRefPubMed Araoz PA, Kirsch J, Primak AN et al (2009) Optimal image reconstruction phase at low and high heart rates in dual-source CT coronary angiography. Int J Cardiovasc Imaging 25:837–845CrossRefPubMed
17.
Zurück zum Zitat Adler G, Meille L, Rohnean A, Sigal-Cinqualbre A, Capderou A, Paul JF (2009) Robustness of end-systolic reconstructions in coronary dual-source CT angiography for high heart rate patients. Eur Radiol. doi:10.1007/s00330-009-1642-9 PubMed Adler G, Meille L, Rohnean A, Sigal-Cinqualbre A, Capderou A, Paul JF (2009) Robustness of end-systolic reconstructions in coronary dual-source CT angiography for high heart rate patients. Eur Radiol. doi:10.​1007/​s00330-009-1642-9 PubMed
18.
Zurück zum Zitat Bamberg F, Sommer WH, Schenzle JC et al (2009) Systolic acquisition of coronary dual-source computed tomography angiography: feasibility in an unselected patient population. Eur Radiol. doi:10.1007/s00330-009-1680-3 Bamberg F, Sommer WH, Schenzle JC et al (2009) Systolic acquisition of coronary dual-source computed tomography angiography: feasibility in an unselected patient population. Eur Radiol. doi:10.​1007/​s00330-009-1680-3
19.
Zurück zum Zitat Petersilka M, Bruder H, Krauss B, Stierstorfer K, Flohr TG (2008) Technical principles of dual source CT. Eur J Radiol 68:362–368CrossRefPubMed Petersilka M, Bruder H, Krauss B, Stierstorfer K, Flohr TG (2008) Technical principles of dual source CT. Eur J Radiol 68:362–368CrossRefPubMed
20.
Zurück zum Zitat Austen WG, Edwards JE, Frye RL et al (1975) A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circ 51(4 Suppl):5–40 Austen WG, Edwards JE, Frye RL et al (1975) A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circ 51(4 Suppl):5–40
21.
Zurück zum Zitat Menzel H, Schibilla H, Teunen D (2000) European guidelines on quality criteria for computed tomography, Publication no. EUR 16262 EN. European Commission, Luxembourg Menzel H, Schibilla H, Teunen D (2000) European guidelines on quality criteria for computed tomography, Publication no. EUR 16262 EN. European Commission, Luxembourg
22.
Zurück zum Zitat Morin RL (1988) Monte Carlo simulation in the radiological sciences. CRC Press, Boca Raton Morin RL (1988) Monte Carlo simulation in the radiological sciences. CRC Press, Boca Raton
23.
Zurück zum Zitat Halliburton SS, Sola S, Kuzmiak SA et al (2008) Effect of dual-source cardiac computed tomography on patient radiation dose in a clinical setting: comparison to single-source imaging. J Cardiovasc Comput Tomogr 2:392–400CrossRefPubMed Halliburton SS, Sola S, Kuzmiak SA et al (2008) Effect of dual-source cardiac computed tomography on patient radiation dose in a clinical setting: comparison to single-source imaging. J Cardiovasc Comput Tomogr 2:392–400CrossRefPubMed
24.
Zurück zum Zitat Achenbach S, Marwan M, Ropers D et al (2009) Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition. Eur Heart J 31(3):340–346CrossRefPubMed Achenbach S, Marwan M, Ropers D et al (2009) Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition. Eur Heart J 31(3):340–346CrossRefPubMed
25.
Zurück zum Zitat Lell M, Hinkmann F, Anders K et al (2009) High-pitch electrocardiogram-triggered computed tomography of the chest: initial results. Invest radiol 44:728–733CrossRefPubMed Lell M, Hinkmann F, Anders K et al (2009) High-pitch electrocardiogram-triggered computed tomography of the chest: initial results. Invest radiol 44:728–733CrossRefPubMed
26.
Zurück zum Zitat Goetti R, Baumuller S, Feuchtner G et al (2010) High-pitch dual-source CT angiography of the thoracic and abdominal aorta: is simultaneous coronary artery assessment possible? AJR Am J Roentgenol 194:938–944CrossRefPubMed Goetti R, Baumuller S, Feuchtner G et al (2010) High-pitch dual-source CT angiography of the thoracic and abdominal aorta: is simultaneous coronary artery assessment possible? AJR Am J Roentgenol 194:938–944CrossRefPubMed
27.
Zurück zum Zitat Gerber TC, Kuzo RS, Morin RL (2005) Techniques and parameters for estimating radiation exposure and dose in cardiac computed tomography. Int J Cardiovasc Imaging 21:165–176CrossRefPubMed Gerber TC, Kuzo RS, Morin RL (2005) Techniques and parameters for estimating radiation exposure and dose in cardiac computed tomography. Int J Cardiovasc Imaging 21:165–176CrossRefPubMed
28.
Zurück zum Zitat McCollough CH, Primak AN, Saba O et al (2007) Dose performance of a 64-channel dual-source CT scanner. Radiology 243:775–784CrossRefPubMed McCollough CH, Primak AN, Saba O et al (2007) Dose performance of a 64-channel dual-source CT scanner. Radiology 243:775–784CrossRefPubMed
29.
Zurück zum Zitat Shapiro MD, Dodd JD, Kalva S et al (2009) A comprehensive electrocardiogram-gated 64-slice multidetector computed tomography imaging protocol to visualize the coronary arteries, thoracic aorta, and pulmonary vasculature in a single breath hold. J Comput Assist Tomogr 33:225–232CrossRefPubMed Shapiro MD, Dodd JD, Kalva S et al (2009) A comprehensive electrocardiogram-gated 64-slice multidetector computed tomography imaging protocol to visualize the coronary arteries, thoracic aorta, and pulmonary vasculature in a single breath hold. J Comput Assist Tomogr 33:225–232CrossRefPubMed
30.
Zurück zum Zitat Johnson TR, Nikolaou K, Becker A et al (2008) Dual-source CT for chest pain assessment. Eur Radiol 18:773–780CrossRefPubMed Johnson TR, Nikolaou K, Becker A et al (2008) Dual-source CT for chest pain assessment. Eur Radiol 18:773–780CrossRefPubMed
Metadaten
Titel
High-pitch dual-source CT coronary angiography: systolic data acquisition at high heart rates
verfasst von
Robert Goetti
Gudrun Feuchtner
Paul Stolzmann
Lotus Desbiolles
Michael Alexander Fischer
Christoph Karlo
Stephan Baumueller
Hans Scheffel
Hatem Alkadhi
Sebastian Leschka
Publikationsdatum
01.11.2010
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 11/2010
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-010-1838-z

Weitere Artikel der Ausgabe 11/2010

European Radiology 11/2010 Zur Ausgabe

Update Radiologie