DNA double-strand breaks as potential indicators for the biological effects of ionising radiation exposure from cardiac CT and conventional coronary angiography: a randomised, controlled study

verfasst von: Dominik Geisel, Elke Zimmermann, Matthias Rief, Johannes Greupner, Michael Laule, Fabian Knebel, Bernd Hamm, Marc Dewey

Erschienen in: European Radiology | Ausgabe 8/2012

Einloggen, um Zugang zu erhalten

Abstract

Objectives

To prospectively compare induced DNA double-strand breaks by cardiac computed tomography (CT) and conventional coronary angiography (CCA).

Methods

56 patients with suspected coronary artery disease were randomised to undergo either CCA or cardiac CT. DNA double-strand breaks were assessed in fluorescence microscopy of blood lymphocytes as indicators of the biological effects of radiation exposure. Radiation doses were estimated using dose–length product (DLP) and dose–area product (DAP) with conversion factors for CT and CCA, respectively.

Results

On average there were 0.12 ± 0.06 induced double-strand breaks per lymphocyte for CT and 0.29 ± 0.18 for diagnostic CCA (P < 0.001). This relative biological effect of ionising radiation from CCA was 1.9 times higher (P < 0.001) than the effective dose estimated by conversion factors would have suggested. The correlation between the biological effects and the estimated radiation doses was excellent for CT (r = 0.951, P < 0.001) and moderate to good for CCA (r = 0.862, P < 0.001). One day after radiation, a complete repair of double-strand breaks to background levels was found in both groups.

Conclusions

Conversion factors may underestimate the relative biological effects of ionising radiation from CCA. DNA double-strand break assessment may provide a strategy for individualised assessments of radiation.

Key Points

• Radiation dose causes concern for both conventional coronary angiography and cardiac CT.
Estimations of the biological effects of ionising radiation may become feasible.
Fewer DNA double-strand breaks are induced by cardiac CT than CCA.
Conversion factors may underestimate the relative effects of ionising radiation from CCA.
Literatur
1.
Zurück zum Zitat Brenner DJ, Hall EJ (2007) Computed tomography – an increasing source of radiation exposure. N Engl J Med 357:2277–2284PubMedCrossRef Brenner DJ, Hall EJ (2007) Computed tomography – an increasing source of radiation exposure. N Engl J Med 357:2277–2284PubMedCrossRef
2.
Zurück zum Zitat Mettler FA, Bhargavan M, Faulkner K et al (2009) Radiologic and nuclear medicine studies in the United States and worldwide: frequency, radiation dose, and comparison with other radiation sources −1950-2007. Radiology 253:520–531PubMedCrossRef Mettler FA, Bhargavan M, Faulkner K et al (2009) Radiologic and nuclear medicine studies in the United States and worldwide: frequency, radiation dose, and comparison with other radiation sources −1950-2007. Radiology 253:520–531PubMedCrossRef
3.
Zurück zum Zitat Fazel R, Krumholz HM, Wang Y et al (2009) Exposure to low-dose ionizing radiation from medical imaging procedures. N Engl J Med 361:849–857PubMedCrossRef Fazel R, Krumholz HM, Wang Y et al (2009) Exposure to low-dose ionizing radiation from medical imaging procedures. N Engl J Med 361:849–857PubMedCrossRef
4.
Zurück zum Zitat Chen J, Einstein AJ, Fazel R et al (2010) Cumulative exposure to ionizing radiation from diagnostic and therapeutic cardiac imaging procedures: a population-based analysis. J Am Coll Cardiol 56:702–711PubMedCrossRef Chen J, Einstein AJ, Fazel R et al (2010) Cumulative exposure to ionizing radiation from diagnostic and therapeutic cardiac imaging procedures: a population-based analysis. J Am Coll Cardiol 56:702–711PubMedCrossRef
5.
Zurück zum Zitat Gerber TC, Carr JJ, Arai AE et al (2009) Ionizing radiation in cardiac imaging: a science advisory from the American Heart Association Committee on Cardiac Imaging of the Council on Clinical Cardiology and Committee on Cardiovascular Imaging and Intervention of the Council on Cardiovascular Radiology and Intervention. Circulation 119:1056–1065PubMedCrossRef Gerber TC, Carr JJ, Arai AE et al (2009) Ionizing radiation in cardiac imaging: a science advisory from the American Heart Association Committee on Cardiac Imaging of the Council on Clinical Cardiology and Committee on Cardiovascular Imaging and Intervention of the Council on Cardiovascular Radiology and Intervention. Circulation 119:1056–1065PubMedCrossRef
6.
Zurück zum Zitat Mark DB, Berman DS, Budoff MJ et al (2010) ACCF/ACR/AHA/NASCI/SAIP/SCAI/SCCT 2010 Expert Consensus Document on Coronary Computed Tomographic Angiography Catheterization and Cardiovascular Interventions 76:E1-E42 Mark DB, Berman DS, Budoff MJ et al (2010) ACCF/ACR/AHA/NASCI/SAIP/SCAI/SCCT 2010 Expert Consensus Document on Coronary Computed Tomographic Angiography Catheterization and Cardiovascular Interventions 76:E1-E42
7.
Zurück zum Zitat Schuetz GM, Zacharopoulou NM, Schlattmann P, Dewey M (2010) Meta-analysis: noninvasive coronary angiography using computed tomography versus magnetic resonance imaging. Ann Intern Med 152:167–177PubMed Schuetz GM, Zacharopoulou NM, Schlattmann P, Dewey M (2010) Meta-analysis: noninvasive coronary angiography using computed tomography versus magnetic resonance imaging. Ann Intern Med 152:167–177PubMed
8.
Zurück zum Zitat Mountford PJ, Temperton DH (1992) Recommendations of the International Commission on Radiological Protection (ICRP) 1990. Eur J Nucl Med 19:77–79PubMedCrossRef Mountford PJ, Temperton DH (1992) Recommendations of the International Commission on Radiological Protection (ICRP) 1990. Eur J Nucl Med 19:77–79PubMedCrossRef
9.
Zurück zum Zitat Pierce DA, Preston DL (2000) Radiation-related cancer risks at low doses among atomic bomb survivors. Radiat Res 154:178–186PubMedCrossRef Pierce DA, Preston DL (2000) Radiation-related cancer risks at low doses among atomic bomb survivors. Radiat Res 154:178–186PubMedCrossRef
10.
Zurück zum Zitat Huda W, Ogden KM, Khorasani MR (2008) Converting dose-length product to effective dose at CT. Radiology 248:995–1003PubMedCrossRef Huda W, Ogden KM, Khorasani MR (2008) Converting dose-length product to effective dose at CT. Radiology 248:995–1003PubMedCrossRef
11.
Zurück zum Zitat Le Heron JC (1992) Estimation of effective dose to the patient during medical x-ray examinations from measurements of the dose-area product. Phys Med Biol 37:2117–2126PubMedCrossRef Le Heron JC (1992) Estimation of effective dose to the patient during medical x-ray examinations from measurements of the dose-area product. Phys Med Biol 37:2117–2126PubMedCrossRef
12.
Zurück zum Zitat Leung KC, Martin CJ (1996) Effective doses for coronary angiography. Br J Radiol 69:426–431PubMedCrossRef Leung KC, Martin CJ (1996) Effective doses for coronary angiography. Br J Radiol 69:426–431PubMedCrossRef
13.
Zurück zum Zitat Geleijns J, Joemai RM, Dewey M et al (2011) Radiation exposure to patients in a multicenter coronary angiography trial (CORE 64). AJR Am J Roentgenol 196:1126–1132PubMedCrossRef Geleijns J, Joemai RM, Dewey M et al (2011) Radiation exposure to patients in a multicenter coronary angiography trial (CORE 64). AJR Am J Roentgenol 196:1126–1132PubMedCrossRef
14.
Zurück zum Zitat Einstein AJ, Moser KW, Thompson RC, Cerqueira MD, Henzlova MJ (2007) Radiation dose to patients from cardiac diagnostic imaging. Circulation 116:1290–1305PubMedCrossRef Einstein AJ, Moser KW, Thompson RC, Cerqueira MD, Henzlova MJ (2007) Radiation dose to patients from cardiac diagnostic imaging. Circulation 116:1290–1305PubMedCrossRef
15.
Zurück zum Zitat Little MP, Wakeford R, Tawn EJ, Bouffler SD, Berrington de Gonzalez A (2009) Risks associated with low doses and low dose rates of ionizing radiation: why linearity may be (almost) the best we can do. Radiology 251:6–12PubMedCrossRef Little MP, Wakeford R, Tawn EJ, Bouffler SD, Berrington de Gonzalez A (2009) Risks associated with low doses and low dose rates of ionizing radiation: why linearity may be (almost) the best we can do. Radiology 251:6–12PubMedCrossRef
16.
Zurück zum Zitat Schlattl H, Zankl M, Petoussi-Henss N (2007) Organ dose conversion coefficients for voxel models of the reference male and female from idealized photon exposures. Phys Med Biol 52:2123–2145PubMedCrossRef Schlattl H, Zankl M, Petoussi-Henss N (2007) Organ dose conversion coefficients for voxel models of the reference male and female from idealized photon exposures. Phys Med Biol 52:2123–2145PubMedCrossRef
17.
Zurück zum Zitat Kobayashi J, Iwabuchi K, Miyagawa K et al (2008) Current topics in DNA double-strand break repair. J Radiat Res (Tokyo) 49:93–103CrossRef Kobayashi J, Iwabuchi K, Miyagawa K et al (2008) Current topics in DNA double-strand break repair. J Radiat Res (Tokyo) 49:93–103CrossRef
18.
Zurück zum Zitat Rothkamm K, Horn S (2009) Gamma-H2AX as protein biomarker for radiation exposure. Ann Ist Super Sanita 45:265–271PubMed Rothkamm K, Horn S (2009) Gamma-H2AX as protein biomarker for radiation exposure. Ann Ist Super Sanita 45:265–271PubMed
19.
Zurück zum Zitat Einstein AJ, Henzlova MJ, Rajagopalan S (2007) Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography. JAMA 298:317–323PubMedCrossRef Einstein AJ, Henzlova MJ, Rajagopalan S (2007) Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography. JAMA 298:317–323PubMedCrossRef
20.
Zurück zum Zitat Einstein AJ (2009) Radiation protection of patients undergoing cardiac computed tomographic angiography. JAMA 301:545–547PubMedCrossRef Einstein AJ (2009) Radiation protection of patients undergoing cardiac computed tomographic angiography. JAMA 301:545–547PubMedCrossRef
21.
Zurück zum Zitat Hausleiter J, Meyer T, Hermann F et al (2009) Estimated radiation dose associated with cardiac CT angiography. JAMA 301:500–507PubMedCrossRef Hausleiter J, Meyer T, Hermann F et al (2009) Estimated radiation dose associated with cardiac CT angiography. JAMA 301:500–507PubMedCrossRef
22.
Zurück zum Zitat Morrish OW, Goldstone KE (2008) An investigation into patient and staff doses from X-ray angiography during coronary interventional procedures. Br J Radiol 81:35–45PubMedCrossRef Morrish OW, Goldstone KE (2008) An investigation into patient and staff doses from X-ray angiography during coronary interventional procedures. Br J Radiol 81:35–45PubMedCrossRef
23.
Zurück zum Zitat Beels L, Bacher K, De Wolf D, Werbrouck J, Thierens H (2009) Gamma-H2AX Foci as a biomarker for patient X-ray exposure in pediatric cardiac catheterization. Are we underestimating radiation risks? Circulation 20:1903–1909CrossRef Beels L, Bacher K, De Wolf D, Werbrouck J, Thierens H (2009) Gamma-H2AX Foci as a biomarker for patient X-ray exposure in pediatric cardiac catheterization. Are we underestimating radiation risks? Circulation 20:1903–1909CrossRef
24.
Zurück zum Zitat Geisel D, Heverhagen JT, Kalinowski M, Wagner HJ (2008) DNA double-strand breaks after percutaneous transluminal angioplasty. Radiology 248:852–859PubMedCrossRef Geisel D, Heverhagen JT, Kalinowski M, Wagner HJ (2008) DNA double-strand breaks after percutaneous transluminal angioplasty. Radiology 248:852–859PubMedCrossRef
25.
Zurück zum Zitat Rothkamm K, Balroop S, Shekhdar J, Fernie P, Goh V (2007) Leukocyte DNA damage after multi-detector row CT: a quantitative biomarker of low-level radiation exposure. Radiology 242:244–251PubMedCrossRef Rothkamm K, Balroop S, Shekhdar J, Fernie P, Goh V (2007) Leukocyte DNA damage after multi-detector row CT: a quantitative biomarker of low-level radiation exposure. Radiology 242:244–251PubMedCrossRef
26.
Zurück zum Zitat Dewey M, Zimmermann E, Deissenrieder F et al (2009) Noninvasive coronary angiography by 320-row computed tomography with lower radiation exposure and maintained diagnostic accuracy: comparison of results with cardiac catheterization in a head-to-head pilot investigation. Circulation 120:867–875PubMedCrossRef Dewey M, Zimmermann E, Deissenrieder F et al (2009) Noninvasive coronary angiography by 320-row computed tomography with lower radiation exposure and maintained diagnostic accuracy: comparison of results with cardiac catheterization in a head-to-head pilot investigation. Circulation 120:867–875PubMedCrossRef
27.
Zurück zum Zitat Deak PD, Smal Y, Kalender WA (2010) Multisection CT protocols: sex- and age-specific conversion factors used to determine effective dose from dose-length product. Radiology 257:158–166PubMedCrossRef Deak PD, Smal Y, Kalender WA (2010) Multisection CT protocols: sex- and age-specific conversion factors used to determine effective dose from dose-length product. Radiology 257:158–166PubMedCrossRef
28.
Zurück zum Zitat Löbrich M, Rief N, Kühne M et al (2005) In vivo formation and repair of DNA double-strand breaks after computed tomography examinations. Proc Natl Acad Sci USA 102:8984–8989PubMedCrossRef Löbrich M, Rief N, Kühne M et al (2005) In vivo formation and repair of DNA double-strand breaks after computed tomography examinations. Proc Natl Acad Sci USA 102:8984–8989PubMedCrossRef
29.
Zurück zum Zitat Tripodi D, Lyons S, Davies D (1971) Separation of peripheral leukocytes by Ficoll density gradient centrifugation. Transplantation 11:487–488PubMedCrossRef Tripodi D, Lyons S, Davies D (1971) Separation of peripheral leukocytes by Ficoll density gradient centrifugation. Transplantation 11:487–488PubMedCrossRef
30.
Zurück zum Zitat Carpenter AE, Jones TR, Lamprecht MR et al (2006) Cell Profiler: image analysis software for identifying and quantifying cell phenotypes. Genome Biol 7:R100PubMedCrossRef Carpenter AE, Jones TR, Lamprecht MR et al (2006) Cell Profiler: image analysis software for identifying and quantifying cell phenotypes. Genome Biol 7:R100PubMedCrossRef
31.
Zurück zum Zitat Jost G, Golfier S, Pietsch H et al (2009) The influence of x-ray contrast agents in computed tomography on the induction of dicentrics and gamma-H2AX foci in lymphocytes of human blood samples. Phys Med Biol 54:6029–6039PubMedCrossRef Jost G, Golfier S, Pietsch H et al (2009) The influence of x-ray contrast agents in computed tomography on the induction of dicentrics and gamma-H2AX foci in lymphocytes of human blood samples. Phys Med Biol 54:6029–6039PubMedCrossRef
32.
Zurück zum Zitat Kataoka Y, Bindokas VP, Duggan RC, Murley JS, Grinda DJ (2006) Flow cytometric analysis of phosphorylated histone H2AX following exposure to ionizing radiation in human microvascular endothelial cells. J Radiat Res (Tokyo) 47:245–257CrossRef Kataoka Y, Bindokas VP, Duggan RC, Murley JS, Grinda DJ (2006) Flow cytometric analysis of phosphorylated histone H2AX following exposure to ionizing radiation in human microvascular endothelial cells. J Radiat Res (Tokyo) 47:245–257CrossRef
33.
Zurück zum Zitat Kuefner MA, Grudzenski S, Hamann J et al (2010) Effect of CT scan protocols on x-ray-induced DNA double-strand breaks in blood lymphocytes of patients undergoing coronary CT angiography. Eur Radiol 20:2917–2924PubMedCrossRef Kuefner MA, Grudzenski S, Hamann J et al (2010) Effect of CT scan protocols on x-ray-induced DNA double-strand breaks in blood lymphocytes of patients undergoing coronary CT angiography. Eur Radiol 20:2917–2924PubMedCrossRef
34.
Zurück zum Zitat Dickey JS, Redon CE, Nakamura AJ, Baird BJ, Sedelnikova OA, Bonner WM (2009) H2AX: functional roles and potential applications. Chromosoma 118:683–692PubMedCrossRef Dickey JS, Redon CE, Nakamura AJ, Baird BJ, Sedelnikova OA, Bonner WM (2009) H2AX: functional roles and potential applications. Chromosoma 118:683–692PubMedCrossRef
35.
Zurück zum Zitat Brenner DJ, Doll R, Goodhead DT et al (2003) Cancer risks attributable to low doses of ionizing radiation: assessing what we really know. Proc Natl Acad Sci USA 100:13761–13766PubMedCrossRef Brenner DJ, Doll R, Goodhead DT et al (2003) Cancer risks attributable to low doses of ionizing radiation: assessing what we really know. Proc Natl Acad Sci USA 100:13761–13766PubMedCrossRef
36.
Zurück zum Zitat Bogaert E, Bacher K, Thierens H (2008) A large-scale multicentre study in Belgium of dose area product values and effective doses in interventional cardiology using contemporary X-ray equipment. Radiat Prot Dosim 128:312–323CrossRef Bogaert E, Bacher K, Thierens H (2008) A large-scale multicentre study in Belgium of dose area product values and effective doses in interventional cardiology using contemporary X-ray equipment. Radiat Prot Dosim 128:312–323CrossRef
37.
Zurück zum Zitat Budoff MJ, Gupta M (2010) Radiation exposure from cardiac imaging procedures: do the risks outweigh the benefits? J Am Coll Cardiol 56:712–714PubMedCrossRef Budoff MJ, Gupta M (2010) Radiation exposure from cardiac imaging procedures: do the risks outweigh the benefits? J Am Coll Cardiol 56:712–714PubMedCrossRef
39.
Zurück zum Zitat Einstein AJ, Elliston CD, Arai AE et al (2010) Radiation dose from single-heartbeat coronary CT Angiography performed with a 320-detector row volume scanner. Radiology 254:698–706PubMedCrossRef Einstein AJ, Elliston CD, Arai AE et al (2010) Radiation dose from single-heartbeat coronary CT Angiography performed with a 320-detector row volume scanner. Radiology 254:698–706PubMedCrossRef
40.
Zurück zum Zitat Seguchi S, Aoyama T, Koyama S, Fujii K, Yamauchi-Kawaura C (2010) Patient radiation dose in prospectively gated axial CT coronary angiography and retrospectively gated helical technique with a 320-detector row CT scanner. Med Phys 37:5579–5585PubMedCrossRef Seguchi S, Aoyama T, Koyama S, Fujii K, Yamauchi-Kawaura C (2010) Patient radiation dose in prospectively gated axial CT coronary angiography and retrospectively gated helical technique with a 320-detector row CT scanner. Med Phys 37:5579–5585PubMedCrossRef
41.
Zurück zum Zitat Schlattl H, Zankl M, Hausleiter J, Hoeschen C (2007) Local organ dose conversion coefficients for angiographic examinations of coronary arteries. Phys Med Biol 52:4393–4408PubMedCrossRef Schlattl H, Zankl M, Hausleiter J, Hoeschen C (2007) Local organ dose conversion coefficients for angiographic examinations of coronary arteries. Phys Med Biol 52:4393–4408PubMedCrossRef
42.
Zurück zum Zitat Frankenberg D, Frankenberg-Schwager M, Garg I et al (2002) Mutation induction and neoplastic transformation in human and human-hamster hybrid cells: Dependence on photon energy and modulation in the low-dose range. J Radiol Prot 22:A17PubMedCrossRef Frankenberg D, Frankenberg-Schwager M, Garg I et al (2002) Mutation induction and neoplastic transformation in human and human-hamster hybrid cells: Dependence on photon energy and modulation in the low-dose range. J Radiol Prot 22:A17PubMedCrossRef
43.
Zurück zum Zitat Frankenberg D, Binder A (1985) RBE Values for the Induction of DNA Double Strand Breaks as a Function of Photon Energy. Radiat Prot Dosim 13:157–159 Frankenberg D, Binder A (1985) RBE Values for the Induction of DNA Double Strand Breaks as a Function of Photon Energy. Radiat Prot Dosim 13:157–159
44.
Zurück zum Zitat Rübe CE, Fricke A, Wendorf J et al (2010) Accumulation of DNA double-strand breaks in normal tissues after fractionated irradiation. Int J Radiat Oncol Biol Phys 76:1206–1213PubMedCrossRef Rübe CE, Fricke A, Wendorf J et al (2010) Accumulation of DNA double-strand breaks in normal tissues after fractionated irradiation. Int J Radiat Oncol Biol Phys 76:1206–1213PubMedCrossRef
45.
Zurück zum Zitat Joiner MC, Marples B, Lambin P, Short SC, Turesson I (2001) Low-dose hypersensitivity: current status and possible mechanisms. Int J Radiat Oncol Biol Phys 49:379–389PubMedCrossRef Joiner MC, Marples B, Lambin P, Short SC, Turesson I (2001) Low-dose hypersensitivity: current status and possible mechanisms. Int J Radiat Oncol Biol Phys 49:379–389PubMedCrossRef
46.
Zurück zum Zitat Shao C, Folkard M, Michael BD, Prise KM (2004) Targeted cytoplasmic irradiation induces bystander responses. Proc Natl Acad Sci USA 101:13495–13500PubMedCrossRef Shao C, Folkard M, Michael BD, Prise KM (2004) Targeted cytoplasmic irradiation induces bystander responses. Proc Natl Acad Sci USA 101:13495–13500PubMedCrossRef
47.
Zurück zum Zitat Löbrich M, Shibata A, Beucher A et al (2010) Gamma H2AX foci analysis for monitoring DNA double-strand break repair: strengths, limitations and optimization. Cell Cycle 9:662–669PubMedCrossRef Löbrich M, Shibata A, Beucher A et al (2010) Gamma H2AX foci analysis for monitoring DNA double-strand break repair: strengths, limitations and optimization. Cell Cycle 9:662–669PubMedCrossRef
48.
Zurück zum Zitat Deckbar D, Stiff T, Koch B, Reis C, Löbrich M, Jeggo PA (2010) The limitations of the G1-S checkpoint. Cancer Res 70:4412–4421PubMedCrossRef Deckbar D, Stiff T, Koch B, Reis C, Löbrich M, Jeggo PA (2010) The limitations of the G1-S checkpoint. Cancer Res 70:4412–4421PubMedCrossRef
49.
Zurück zum Zitat Khanna KK, Jackson SP (2001) DNA double-strand breaks: signaling, repair and the cancer connection. Nat Genet 27:247–254PubMedCrossRef Khanna KK, Jackson SP (2001) DNA double-strand breaks: signaling, repair and the cancer connection. Nat Genet 27:247–254PubMedCrossRef
50.
Zurück zum Zitat Mitelman F, Johansson B, Mertens F (2007) The impact of translocations and gene fusions on cancer causation. Nat Rev Cancer 7:233–245PubMedCrossRef Mitelman F, Johansson B, Mertens F (2007) The impact of translocations and gene fusions on cancer causation. Nat Rev Cancer 7:233–245PubMedCrossRef
51.
Zurück zum Zitat Grudzenski S, Kuefner MA, Heckmann MB, Uder M, Löbrich M (2009) Contrast medium-enhanced radiation damage caused by CT examinations. Radiology 253:706PubMedCrossRef Grudzenski S, Kuefner MA, Heckmann MB, Uder M, Löbrich M (2009) Contrast medium-enhanced radiation damage caused by CT examinations. Radiology 253:706PubMedCrossRef
52.
Zurück zum Zitat Adams FH, Norman A, Mello RS, Bass D (1977) Effect of radiation and contrast media on chromosomes. Preliminary report. Radiology 124:823–826PubMed Adams FH, Norman A, Mello RS, Bass D (1977) Effect of radiation and contrast media on chromosomes. Preliminary report. Radiology 124:823–826PubMed
53.
Zurück zum Zitat Venneri L, Rossi F, Botto N et al (2009) Cancer risk from professional exposure in staff working in cardiac catheterization laboratory: insights from the National Research Council's Biological Effects of Ionizing Radiation VII Report. Am Heart J 157:118–124PubMedCrossRef Venneri L, Rossi F, Botto N et al (2009) Cancer risk from professional exposure in staff working in cardiac catheterization laboratory: insights from the National Research Council's Biological Effects of Ionizing Radiation VII Report. Am Heart J 157:118–124PubMedCrossRef
54.
Zurück zum Zitat Andreassi MG, Cioppa A, Botto N et al (2005) Somatic DNA damage in interventional cardiologists: a case–control study. FASEB J 19:998–999PubMed Andreassi MG, Cioppa A, Botto N et al (2005) Somatic DNA damage in interventional cardiologists: a case–control study. FASEB J 19:998–999PubMed
55.
Zurück zum Zitat Maurer MH, Zimmermann E, Schlattmann P, Germershausen C, Hamm B, Dewey M (2012) Indications, imaging technique, and reading of cardiac computed tomography: survey of clinical practice. Eur Radiol 22:59–72PubMedCrossRef Maurer MH, Zimmermann E, Schlattmann P, Germershausen C, Hamm B, Dewey M (2012) Indications, imaging technique, and reading of cardiac computed tomography: survey of clinical practice. Eur Radiol 22:59–72PubMedCrossRef
56.
Zurück zum Zitat Miller JM, Dewey M, Vavere AL et al (2009) Coronary CT angiography using 64 detector rows: methods and design of the multi-centre trial CORE-64. Eur Radiol 19:816–828PubMedCrossRef Miller JM, Dewey M, Vavere AL et al (2009) Coronary CT angiography using 64 detector rows: methods and design of the multi-centre trial CORE-64. Eur Radiol 19:816–828PubMedCrossRef
57.
Zurück zum Zitat Achenbach S, Marwan M, Ropers D et al (2010) Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition. Eur Heart J 31:340–346PubMedCrossRef Achenbach S, Marwan M, Ropers D et al (2010) Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition. Eur Heart J 31:340–346PubMedCrossRef
58.
Zurück zum Zitat Achenbach S, Anders K, Kalender WA (2008) Dual-source cardiac computed tomography: image quality and dose considerations. Eur Radiol 18:1188–1198PubMedCrossRef Achenbach S, Anders K, Kalender WA (2008) Dual-source cardiac computed tomography: image quality and dose considerations. Eur Radiol 18:1188–1198PubMedCrossRef
59.
Zurück zum Zitat aff GL, Chinnaiyan KM, Share DA et al (2009) Radiation dose from cardiac computed tomography before and after implementation of radiation dose-reduction techniques. JAMA 301:2340–2348PubMedCrossRef aff GL, Chinnaiyan KM, Share DA et al (2009) Radiation dose from cardiac computed tomography before and after implementation of radiation dose-reduction techniques. JAMA 301:2340–2348PubMedCrossRef
60.
61.
Zurück zum Zitat Brenner DJ, Hricak H (2010) Radiation exposure from medical imaging: time to regulate? JAMA 304:208–209PubMedCrossRef Brenner DJ, Hricak H (2010) Radiation exposure from medical imaging: time to regulate? JAMA 304:208–209PubMedCrossRef
62.
Zurück zum Zitat Zanzonico P, Rothenberg LN, Strauss HW (2006) Radiation exposure of computed tomography and direct intracoronary angiography: risk has its reward. J Am Coll Cardiol 47:1846–1849PubMedCrossRef Zanzonico P, Rothenberg LN, Strauss HW (2006) Radiation exposure of computed tomography and direct intracoronary angiography: risk has its reward. J Am Coll Cardiol 47:1846–1849PubMedCrossRef
63.
Zurück zum Zitat Smith-Bindman R, Lipson J, Marcus R et al (2009) Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer. Arch Intern Med 169:2078–2086PubMedCrossRef Smith-Bindman R, Lipson J, Marcus R et al (2009) Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer. Arch Intern Med 169:2078–2086PubMedCrossRef
64.
Zurück zum Zitat McCollough CH, Leng S, Yu L, Cody DD, Boone JM, McNitt-Gray MF (2011) CT dose index and patient dose: they are not the same thing. Radiology 259:311–316PubMedCrossRef McCollough CH, Leng S, Yu L, Cody DD, Boone JM, McNitt-Gray MF (2011) CT dose index and patient dose: they are not the same thing. Radiology 259:311–316PubMedCrossRef
65.
Zurück zum Zitat Pryor DB, Shaw L, McCants CB et al (1993) Value of the history and physical in identifying patients at increased risk for coronary artery disease. Ann Intern Med 118:81–90PubMed Pryor DB, Shaw L, McCants CB et al (1993) Value of the history and physical in identifying patients at increased risk for coronary artery disease. Ann Intern Med 118:81–90PubMed
Metadaten
Titel
DNA double-strand breaks as potential indicators for the biological effects of ionising radiation exposure from cardiac CT and conventional coronary angiography: a randomised, controlled study
verfasst von
Dominik Geisel
Elke Zimmermann
Matthias Rief
Johannes Greupner
Michael Laule
Fabian Knebel
Bernd Hamm
Marc Dewey
Publikationsdatum
01.08.2012
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 8/2012
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-012-2426-1

Weitere Artikel der Ausgabe 8/2012

European Radiology 8/2012 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.