Skip to main content
Erschienen in: European Radiology 11/2012

01.11.2012 | Oncology

PET/CT in lung cancer: Influence of contrast medium on quantitative and clinical assessment

verfasst von: Florian F. Behrendt, Yavuz Temur, Frederik A. Verburg, Moritz Palmowski, Thomas Krohn, Hubertus Pietsch, Christiane K. Kuhl, Felix M. Mottaghy

Erschienen in: European Radiology | Ausgabe 11/2012

Einloggen, um Zugang zu erhalten

Abstract

Objectives

To evaluate the influence of intravenous contrast medium and different contrast medium phases on attenuation correction, PET image quality and clinical staging in combined PET/CT in patients with a suspicion of lung cancer.

Methods

Sixty patients with a suspicion of lung cancer were prospectively enrolled for combined 18F-FDG-PET/CT examination. PET images were reconstructed with non-enhanced and arterial and venous phase contrast CT. Maximum and mean standardised uptake values (SUVmax and SUVmean) and contrast enhancement (HU) were determined in the subclavian vein, ascending aorta, abdominal aorta, inferior vena cava, portal vein, liver and kidney and lung tumour. PET data were evaluated visually for clinical staging and image quality.

Results

SUVmax was significantly increased between contrast and non-contrast PET/CT at all anatomic sites (all P < 0.001). SUVmax was significantly increased for arterial PET/CT compared to venous PET/CT in the arteries (all P < 0.001). Venous PET/CT resulted in significantly higher SUVmax values compared to arterial PET/CT in the parenchymatous organs (all P < 0.05). Visual clinical evaluation of malignant lesions showed no differences between contrast and non-contrast PET/CT (P = 1.0).

Conclusions

Contrast enhanced CT is suitable for attenuation correction in combined PET/CT in lung cancer; it affects neither the clinical assessment nor image quality of the PET images.

Key Points

Positron emission tomography combined with computed tomography is now a mainstream investigation
There has been debate about whether CT contrast agents affect PET results
Contrast-enhanced CT is satisfactory for attenuation correction in lung cancer PET/CT
Multiphase CT does not affect PET; additional unenhanced CT is unnecessary
For quantitative follow-up PET analysis, an identical PET/CT protocol is required
Literatur
1.
Zurück zum Zitat Cantwell CP, Setty BN, Holalkere N, Sahani DV, Fischman AJ, Blake MA (2008) Liver lesion detection and characterization in patients with colorectal cancer: a comparison of low radiation dose non-enhanced PET/CT, contrast-enhanced PET/CT, and liver MRI. J Comput Assist Tomogr 325:738–744CrossRef Cantwell CP, Setty BN, Holalkere N, Sahani DV, Fischman AJ, Blake MA (2008) Liver lesion detection and characterization in patients with colorectal cancer: a comparison of low radiation dose non-enhanced PET/CT, contrast-enhanced PET/CT, and liver MRI. J Comput Assist Tomogr 325:738–744CrossRef
2.
Zurück zum Zitat Pfannenberg AC, Aschoff P, Brechtel K et al (2007) Low dose non-enhanced CT versus standard dose contrast-enhanced CT in combined PET/CT protocols for staging and therapy planning in non-small cell lung cancer. Eur J Nucl Med Mol Imaging 34:36–44PubMedCrossRef Pfannenberg AC, Aschoff P, Brechtel K et al (2007) Low dose non-enhanced CT versus standard dose contrast-enhanced CT in combined PET/CT protocols for staging and therapy planning in non-small cell lung cancer. Eur J Nucl Med Mol Imaging 34:36–44PubMedCrossRef
3.
Zurück zum Zitat Pfannenberg AC, Aschoff P, Brechtel K et al (2007) Value of contrast-enhanced multiphase CT in combined PET/CT protocols for oncological imaging. Br J Radiol 80:437–445PubMedCrossRef Pfannenberg AC, Aschoff P, Brechtel K et al (2007) Value of contrast-enhanced multiphase CT in combined PET/CT protocols for oncological imaging. Br J Radiol 80:437–445PubMedCrossRef
4.
Zurück zum Zitat Tateishi U, Maeda T, Morimoto T, Miyake M, Arai Y, Kim EE (2007) Non-enhanced CT versus contrast-enhanced CT in integrated PET/CT studies for nodal staging of rectal cancer. Eur J Nucl Med Mol Imaging 34:1627–1634PubMedCrossRef Tateishi U, Maeda T, Morimoto T, Miyake M, Arai Y, Kim EE (2007) Non-enhanced CT versus contrast-enhanced CT in integrated PET/CT studies for nodal staging of rectal cancer. Eur J Nucl Med Mol Imaging 34:1627–1634PubMedCrossRef
5.
Zurück zum Zitat Antoch G, Stattaus J, Nemat AT et al (2003) Non-small cell lung cancer: dual-modality PET/CT in preoperative staging. Radiology 229:526–533PubMedCrossRef Antoch G, Stattaus J, Nemat AT et al (2003) Non-small cell lung cancer: dual-modality PET/CT in preoperative staging. Radiology 229:526–533PubMedCrossRef
6.
Zurück zum Zitat Lardinois D, Weder W, Hany TF et al (2003) Staging of non-small-cell lung cancer with integrated positron-emission tomography and computed tomography. N Engl J Med 348:2500–2507PubMedCrossRef Lardinois D, Weder W, Hany TF et al (2003) Staging of non-small-cell lung cancer with integrated positron-emission tomography and computed tomography. N Engl J Med 348:2500–2507PubMedCrossRef
7.
Zurück zum Zitat Delbeke D, Coleman RE, Guiberteau MJ et al (2006) Procedure guideline for SPECT/CT imaging 1.0. J Nucl Med 47:1227–1234PubMed Delbeke D, Coleman RE, Guiberteau MJ et al (2006) Procedure guideline for SPECT/CT imaging 1.0. J Nucl Med 47:1227–1234PubMed
8.
Zurück zum Zitat Boellaard R, O'Doherty MJ, Weber WA et al (2010) FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0. Eur J Nucl Med Mol Imaging 37:181–200PubMedCrossRef Boellaard R, O'Doherty MJ, Weber WA et al (2010) FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0. Eur J Nucl Med Mol Imaging 37:181–200PubMedCrossRef
9.
Zurück zum Zitat Krause BJ, Beyer T, Bockisch A et al (2007) FDG-PET/CT in oncology. German Guideline. Nuklearmedizin 46:291–301PubMed Krause BJ, Beyer T, Bockisch A et al (2007) FDG-PET/CT in oncology. German Guideline. Nuklearmedizin 46:291–301PubMed
10.
Zurück zum Zitat Antoch G, Freudenberg LS, Egelhof T et al (2002) Focal tracer uptake: a potential artifact in contrast-enhanced dual-modality PET/CT scans. J Nucl Med 43:1339–1342PubMed Antoch G, Freudenberg LS, Egelhof T et al (2002) Focal tracer uptake: a potential artifact in contrast-enhanced dual-modality PET/CT scans. J Nucl Med 43:1339–1342PubMed
11.
Zurück zum Zitat Nakamoto Y, Chin BB, Kraitchman DL, Lawler LP, Marshall LT, Wahl RL (2003) Effects of nonionic intravenous contrast agents at PET/CT imaging: phantom and canine studies. Radiology 227:817–824PubMedCrossRef Nakamoto Y, Chin BB, Kraitchman DL, Lawler LP, Marshall LT, Wahl RL (2003) Effects of nonionic intravenous contrast agents at PET/CT imaging: phantom and canine studies. Radiology 227:817–824PubMedCrossRef
12.
Zurück zum Zitat Berthelsen AK, Holm S, Loft A, Klausen TL, Andersen F, Hojgaard L (2005) PET/CT with intravenous contrast can be used for PET attenuation correction in cancer patients. Eur J Nucl Med Mol Imaging 32:1167–1175PubMedCrossRef Berthelsen AK, Holm S, Loft A, Klausen TL, Andersen F, Hojgaard L (2005) PET/CT with intravenous contrast can be used for PET attenuation correction in cancer patients. Eur J Nucl Med Mol Imaging 32:1167–1175PubMedCrossRef
13.
Zurück zum Zitat Mawlawi O, Erasmus JJ, Munden RF et al (2006) Quantifying the effect of IV contrast media on integrated PET/CT: clinical evaluation. AJR Am J Roentgenol 186:308–319PubMedCrossRef Mawlawi O, Erasmus JJ, Munden RF et al (2006) Quantifying the effect of IV contrast media on integrated PET/CT: clinical evaluation. AJR Am J Roentgenol 186:308–319PubMedCrossRef
14.
Zurück zum Zitat Yau YY, Chan WS, Tam YM et al (2005) Application of intravenous contrast in PET/CT: does it really introduce significant attenuation correction error? J Nucl Med 46:283–291PubMed Yau YY, Chan WS, Tam YM et al (2005) Application of intravenous contrast in PET/CT: does it really introduce significant attenuation correction error? J Nucl Med 46:283–291PubMed
15.
Zurück zum Zitat Bunyaviroch T, Turkington TG, Wong TZ, Wilson JW, Colsher JG, Coleman RE (2008) Quantitative effects of contrast enhanced CT attenuation correction on PET SUV measurements. Mol Imaging Biol 10:107–113PubMedCrossRef Bunyaviroch T, Turkington TG, Wong TZ, Wilson JW, Colsher JG, Coleman RE (2008) Quantitative effects of contrast enhanced CT attenuation correction on PET SUV measurements. Mol Imaging Biol 10:107–113PubMedCrossRef
16.
Zurück zum Zitat Surti S, Kuhn A, Werner ME, Perkins AE, Kolthammer J, Karp JS (2007) Performance of Philips Gemini TF PET/CT scanner with special consideration for its time-of-flight imaging capabilities. J Nucl Med 48:471–480PubMed Surti S, Kuhn A, Werner ME, Perkins AE, Kolthammer J, Karp JS (2007) Performance of Philips Gemini TF PET/CT scanner with special consideration for its time-of-flight imaging capabilities. J Nucl Med 48:471–480PubMed
17.
Zurück zum Zitat Surti S, Scheuermann J, El Fakhri G et al (2011) Impact of time-of-flight PET on whole-body oncologic studies: a human observer lesion detection and localization study. J Nucl Med 52:712–719PubMedCrossRef Surti S, Scheuermann J, El Fakhri G et al (2011) Impact of time-of-flight PET on whole-body oncologic studies: a human observer lesion detection and localization study. J Nucl Med 52:712–719PubMedCrossRef
18.
Zurück zum Zitat An YS, Sheen SS, Oh YJ, Hwang SC, Yoon JK (2007) Nonionic intravenous contrast agent does not cause clinically significant artifacts to 18F-FDG PET/CT in patients with lung cancer. Ann Nucl Med 21:585–592PubMedCrossRef An YS, Sheen SS, Oh YJ, Hwang SC, Yoon JK (2007) Nonionic intravenous contrast agent does not cause clinically significant artifacts to 18F-FDG PET/CT in patients with lung cancer. Ann Nucl Med 21:585–592PubMedCrossRef
19.
Zurück zum Zitat Aschoff P, Plathow C, Beyer T et al (2012) Multiphase contrast-enhanced CT with highly concentrated contrast agent can be used for PET attenuation correction in integrated PET/CT imaging. Eur J Nucl Med Mol Imaging 39:316–325PubMedCrossRef Aschoff P, Plathow C, Beyer T et al (2012) Multiphase contrast-enhanced CT with highly concentrated contrast agent can be used for PET attenuation correction in integrated PET/CT imaging. Eur J Nucl Med Mol Imaging 39:316–325PubMedCrossRef
20.
Zurück zum Zitat Fleischmann D (2003) High-concentration contrast media in MDCT angiography: principles and rationale. Eur Radiol 13:N39–N43PubMedCrossRef Fleischmann D (2003) High-concentration contrast media in MDCT angiography: principles and rationale. Eur Radiol 13:N39–N43PubMedCrossRef
21.
Zurück zum Zitat Heusner TA, Kuehl H, Veit-Haibach P et al (2008) Highly iodinated intravenous contrast material for PET/CT - a feasibility study. Rofo 180:740–745PubMedCrossRef Heusner TA, Kuehl H, Veit-Haibach P et al (2008) Highly iodinated intravenous contrast material for PET/CT - a feasibility study. Rofo 180:740–745PubMedCrossRef
22.
Zurück zum Zitat Foley WD (2002) Special focus session: multidetector CT: abdominal visceral imaging. Radiographics 22:701–719PubMed Foley WD (2002) Special focus session: multidetector CT: abdominal visceral imaging. Radiographics 22:701–719PubMed
23.
Zurück zum Zitat Israel GM, Bosniak MA (2008) Pitfalls in renal mass evaluation and how to avoid them. Radiographics 28:1325–1338PubMedCrossRef Israel GM, Bosniak MA (2008) Pitfalls in renal mass evaluation and how to avoid them. Radiographics 28:1325–1338PubMedCrossRef
24.
Zurück zum Zitat Leide-Svegborn S (2010) Radiation exposure of patients and personnel from a PET/CT procedure with 18F-FDG. Radiat Prot Dosimetry 139:208–213PubMedCrossRef Leide-Svegborn S (2010) Radiation exposure of patients and personnel from a PET/CT procedure with 18F-FDG. Radiat Prot Dosimetry 139:208–213PubMedCrossRef
Metadaten
Titel
PET/CT in lung cancer: Influence of contrast medium on quantitative and clinical assessment
verfasst von
Florian F. Behrendt
Yavuz Temur
Frederik A. Verburg
Moritz Palmowski
Thomas Krohn
Hubertus Pietsch
Christiane K. Kuhl
Felix M. Mottaghy
Publikationsdatum
01.11.2012
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 11/2012
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-012-2515-1

Weitere Artikel der Ausgabe 11/2012

European Radiology 11/2012 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.