Skip to main content
Erschienen in: European Radiology 12/2014

01.12.2014 | Chest

Comparison of chest radiography, chest digital tomosynthesis and low dose MDCT to detect small ground-glass opacity nodules: an anthropomorphic chest phantom study

verfasst von: Kyung Won Doo, Eun-Young Kang, Hwan Seok Yong, Soo-Youn Ham, Ki Yeol Lee, Ji Yung Choo

Erschienen in: European Radiology | Ausgabe 12/2014

Einloggen, um Zugang zu erhalten

Abstract

Objectives

The purpose of this study was to evaluate the diagnostic performance of chest radiography (CXR), chest digital tomosynthesis (DT) and low dose multidetector computed tomography (LDCT) for the detection of small pulmonary ground-glass opacity (GGO) nodules, using an anthropomorphic chest phantom.

Methods

Artificial pulmonary nodules were placed in a phantom and a total of 40 samples of different nodule settings underwent CXR, DT and LDCT. The images were randomly read by three experienced chest radiologists. Free-response receiver-operating characteristics (FROC) were used.

Results

The figures of merit for the FROC curves averaged for the three observers were 0.41, 0.37 and 0.76 for CXR, DT and LDCT, respectively. FROC analyses revealed significantly better performance of LDCT over CXR or DT for the detection of GGO nodules (P < 0.05). The difference in detectability between CXR and DT was not statistically significant (P = 0.73).

Conclusion

The diagnostic performance of DT for the detection of pulmonary small GGO nodules was not significantly different from that of CXR, but LDCT performed significantly better than both CXR and DT. DT is not a suitable alternative to CT for small GGO nodule detection, and LDCT remains the method of choice for this purpose.

Key Points

For GGO nodule detection, DT was not significantly different from CXR.
DT is not a suitable alternative to CT for GGO nodule detection.
LDCT is the method of choice for GGO nodule detection.
Literatur
1.
Zurück zum Zitat Geitung JT, Skjaerstad LM, Gothlin JH (1999) Clinical utility of chest roentgenograms. Eur Radiol 9:721–723PubMedCrossRef Geitung JT, Skjaerstad LM, Gothlin JH (1999) Clinical utility of chest roentgenograms. Eur Radiol 9:721–723PubMedCrossRef
2.
Zurück zum Zitat Speets AM, van der Graaf Y, Hoes AW et al (2006) Chest radiography in general practice: indications, diagnostic yield and consequences for patient management. Br J Gen Pract 56:574–578PubMedCentralPubMed Speets AM, van der Graaf Y, Hoes AW et al (2006) Chest radiography in general practice: indications, diagnostic yield and consequences for patient management. Br J Gen Pract 56:574–578PubMedCentralPubMed
3.
Zurück zum Zitat Samei E, Flynn MJ, Eyler WR (1999) Detection of subtle lung nodules: relative influence of quantum and anatomic noise on chest radiographs. Radiology 213:727–734PubMedCrossRef Samei E, Flynn MJ, Eyler WR (1999) Detection of subtle lung nodules: relative influence of quantum and anatomic noise on chest radiographs. Radiology 213:727–734PubMedCrossRef
4.
Zurück zum Zitat Hakansson M, Bath M, Borjesson S, Kheddache S, Johnsson AA, Mansson LG (2005) Nodule detection in digital chest radiography: effect of system noise. Radiat Prot Dosim 114:97–101CrossRef Hakansson M, Bath M, Borjesson S, Kheddache S, Johnsson AA, Mansson LG (2005) Nodule detection in digital chest radiography: effect of system noise. Radiat Prot Dosim 114:97–101CrossRef
5.
Zurück zum Zitat Schenzle JC, Sommer WH, Neumaier K et al (2010) Dual energy CT of the chest: how about the dose? Investig Radiol 45:347–353 Schenzle JC, Sommer WH, Neumaier K et al (2010) Dual energy CT of the chest: how about the dose? Investig Radiol 45:347–353
6.
Zurück zum Zitat Lell MM, May M, Deak P et al (2011) High-pitch spiral computed tomography: effect on image quality and radiation dose in pediatric chest computed tomography. Investig Radiol 46:116–123CrossRef Lell MM, May M, Deak P et al (2011) High-pitch spiral computed tomography: effect on image quality and radiation dose in pediatric chest computed tomography. Investig Radiol 46:116–123CrossRef
7.
Zurück zum Zitat Katsura M, Matsuda I, Akahane M et al (2013) Model-based iterative reconstruction technique for ultralow-dose chest CT: comparison of pulmonary nodule detectability with the adaptive statistical iterative reconstruction technique. Investig Radiol 48:206–212 Katsura M, Matsuda I, Akahane M et al (2013) Model-based iterative reconstruction technique for ultralow-dose chest CT: comparison of pulmonary nodule detectability with the adaptive statistical iterative reconstruction technique. Investig Radiol 48:206–212
8.
Zurück zum Zitat Sone S, Kasuga T, Sakai F et al (1991) Development of a high-resolution digital tomosynthesis system and its clinical application. Radiographics 11:807–822PubMedCrossRef Sone S, Kasuga T, Sakai F et al (1991) Development of a high-resolution digital tomosynthesis system and its clinical application. Radiographics 11:807–822PubMedCrossRef
9.
Zurück zum Zitat Dobbins JT 3rd, McAdams HP, Godfrey DJ, Li CM (2008) Digital tomosynthesis of the chest. J Thorac Imaging 23:86–92PubMedCrossRef Dobbins JT 3rd, McAdams HP, Godfrey DJ, Li CM (2008) Digital tomosynthesis of the chest. J Thorac Imaging 23:86–92PubMedCrossRef
10.
Zurück zum Zitat James TD, McAdams HP, Song JW et al (2008) Digital tomosynthesis of the chest for lung nodule detection: interim sensitivity results from an ongoing NIH-sponsored trial. Med Phys 35:2554–2557PubMedCrossRef James TD, McAdams HP, Song JW et al (2008) Digital tomosynthesis of the chest for lung nodule detection: interim sensitivity results from an ongoing NIH-sponsored trial. Med Phys 35:2554–2557PubMedCrossRef
11.
Zurück zum Zitat Vikgren J, Zachrisson S, Svalkvist A et al (2008) Comparison of chest tomosynthesis and chest radiography for detection of pulmonary nodules: human observer study of clinical cases. Radiology 249:1034–1041PubMedCrossRef Vikgren J, Zachrisson S, Svalkvist A et al (2008) Comparison of chest tomosynthesis and chest radiography for detection of pulmonary nodules: human observer study of clinical cases. Radiology 249:1034–1041PubMedCrossRef
12.
Zurück zum Zitat Yamada Y, Jinzaki M, Hasegawa I et al (2011) Fast scanning tomosynthesis for the detection of pulmonary nodules: diagnostic performance compared with chest radiography, using multidetector-row computed tomography as the reference. Investig Radiol 46:471–477CrossRef Yamada Y, Jinzaki M, Hasegawa I et al (2011) Fast scanning tomosynthesis for the detection of pulmonary nodules: diagnostic performance compared with chest radiography, using multidetector-row computed tomography as the reference. Investig Radiol 46:471–477CrossRef
13.
Zurück zum Zitat Lee G, Jeong YJ, Kim KI et al (2013) Comparison of chest digital tomosynthesis and chest radiography for detection of asbestos-related pleuropulmonary disease. Clin Radiol 68:376–382PubMedCrossRef Lee G, Jeong YJ, Kim KI et al (2013) Comparison of chest digital tomosynthesis and chest radiography for detection of asbestos-related pleuropulmonary disease. Clin Radiol 68:376–382PubMedCrossRef
14.
Zurück zum Zitat Yamada Y, Jinzaki M, Hashimoto M et al (2013) Tomosynthesis for the early detection of pulmonary emphysema: diagnostic performance compared with chest radiography, using multidetector computed tomography as reference. Eur Radiol 23:2118–2126PubMedCrossRef Yamada Y, Jinzaki M, Hashimoto M et al (2013) Tomosynthesis for the early detection of pulmonary emphysema: diagnostic performance compared with chest radiography, using multidetector computed tomography as reference. Eur Radiol 23:2118–2126PubMedCrossRef
15.
Zurück zum Zitat Naidich DP, Bankier AA, MacMahon H et al (2013) Recommendations for the management of subsolid pulmonary nodules detected at CT: a statement from the Fleischner Society. Radiology 266:304–317PubMedCrossRef Naidich DP, Bankier AA, MacMahon H et al (2013) Recommendations for the management of subsolid pulmonary nodules detected at CT: a statement from the Fleischner Society. Radiology 266:304–317PubMedCrossRef
16.
Zurück zum Zitat Hayashi H, Ashizawa K, Uetani M et al (2009) Detectability of peripheral lung cancer on chest radiographs: effect of the size, location and extent of ground-glass opacity. Br J Radiol 82:272–278PubMedCrossRef Hayashi H, Ashizawa K, Uetani M et al (2009) Detectability of peripheral lung cancer on chest radiographs: effect of the size, location and extent of ground-glass opacity. Br J Radiol 82:272–278PubMedCrossRef
17.
Zurück zum Zitat Hashemi S, Mehrez H, Cobbold RS, Paul NS (2014) Optimal image reconstruction for detection and characterization of small pulmonary nodules during low-dose CT. Eur Radiol. doi:10.1007/s00330-014-3142-9 PubMed Hashemi S, Mehrez H, Cobbold RS, Paul NS (2014) Optimal image reconstruction for detection and characterization of small pulmonary nodules during low-dose CT. Eur Radiol. doi:10.​1007/​s00330-014-3142-9 PubMed
18.
Zurück zum Zitat Terzi A, Bertolaccini L, Viti A et al (2013) Lung cancer detection with digital chest tomosynthesis: baseline results from the observational study SOS. J Thorac Oncol 8:685–692PubMedCrossRef Terzi A, Bertolaccini L, Viti A et al (2013) Lung cancer detection with digital chest tomosynthesis: baseline results from the observational study SOS. J Thorac Oncol 8:685–692PubMedCrossRef
19.
Zurück zum Zitat Johnsson AA, Vikgren J, Bath M (2014) Chest tomosynthesis: technical and clinical perspectives. Semin Respir Crit Care Med 35:17–26PubMedCrossRef Johnsson AA, Vikgren J, Bath M (2014) Chest tomosynthesis: technical and clinical perspectives. Semin Respir Crit Care Med 35:17–26PubMedCrossRef
20.
Zurück zum Zitat Zhao F, Zeng Y, Peng G et al (2012) Experimental study of detection of nodules showing ground-glass opacity and radiation dose by using anthropomorphic chest phantom: digital tomosynthesis and multidetector CT. J Comput Assist Tomogr 36:523–527PubMedCrossRef Zhao F, Zeng Y, Peng G et al (2012) Experimental study of detection of nodules showing ground-glass opacity and radiation dose by using anthropomorphic chest phantom: digital tomosynthesis and multidetector CT. J Comput Assist Tomogr 36:523–527PubMedCrossRef
21.
Zurück zum Zitat Gomi T, Nakajima M, Fujiwara H et al (2012) Comparison between chest digital tomosynthesis and CT as a screening method to detect artificial pulmonary nodules: a phantom study. Br J Radiol 85:e622–e629PubMedCentralPubMedCrossRef Gomi T, Nakajima M, Fujiwara H et al (2012) Comparison between chest digital tomosynthesis and CT as a screening method to detect artificial pulmonary nodules: a phantom study. Br J Radiol 85:e622–e629PubMedCentralPubMedCrossRef
22.
Zurück zum Zitat Kim EY, Chung MJ, Lee HY, Koh WJ, Jung HN, Lee KS (2010) Pulmonary mycobacterial disease: diagnostic performance of low-dose digital tomosynthesis as compared with chest radiography. Radiology 257:269–277PubMedCrossRef Kim EY, Chung MJ, Lee HY, Koh WJ, Jung HN, Lee KS (2010) Pulmonary mycobacterial disease: diagnostic performance of low-dose digital tomosynthesis as compared with chest radiography. Radiology 257:269–277PubMedCrossRef
23.
Zurück zum Zitat Quaia E, Baratella E, Cioffi V et al (2010) The value of digital tomosynthesis in the diagnosis of suspected pulmonary lesions on chest radiography: analysis of diagnostic accuracy and confidence. Acad Radiol 17:1267–1274PubMedCrossRef Quaia E, Baratella E, Cioffi V et al (2010) The value of digital tomosynthesis in the diagnosis of suspected pulmonary lesions on chest radiography: analysis of diagnostic accuracy and confidence. Acad Radiol 17:1267–1274PubMedCrossRef
24.
Zurück zum Zitat Nagao M, Murase K, Yasuhara Y et al (2002) Measurement of localized ground-glass attenuation on thin-section computed tomography images: correlation with the progression of bronchioloalveolar carcinoma of the lung. Investig Radiol 37:692–697CrossRef Nagao M, Murase K, Yasuhara Y et al (2002) Measurement of localized ground-glass attenuation on thin-section computed tomography images: correlation with the progression of bronchioloalveolar carcinoma of the lung. Investig Radiol 37:692–697CrossRef
25.
Zurück zum Zitat McCollough CH, Chen GH, Kalender W et al (2012) Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT. Radiology 264:567–580PubMedCentralPubMedCrossRef McCollough CH, Chen GH, Kalender W et al (2012) Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT. Radiology 264:567–580PubMedCentralPubMedCrossRef
26.
Zurück zum Zitat Oda S, Awai K, Liu D et al (2008) Ground-glass opacities on thin-section helical CT: differentiation between bronchioloalveolar carcinoma and atypical adenomatous hyperplasia. AJR Am J Roentgenol 190:1363–1368PubMedCrossRef Oda S, Awai K, Liu D et al (2008) Ground-glass opacities on thin-section helical CT: differentiation between bronchioloalveolar carcinoma and atypical adenomatous hyperplasia. AJR Am J Roentgenol 190:1363–1368PubMedCrossRef
27.
Zurück zum Zitat Ikeda K, Awai K, Mori T, Kawanaka K, Yamashita Y, Nomori H (2007) Differential diagnosis of ground-glass opacity nodules: CT number analysis by three-dimensional computerized quantification. Chest 132:984–990PubMedCrossRef Ikeda K, Awai K, Mori T, Kawanaka K, Yamashita Y, Nomori H (2007) Differential diagnosis of ground-glass opacity nodules: CT number analysis by three-dimensional computerized quantification. Chest 132:984–990PubMedCrossRef
Metadaten
Titel
Comparison of chest radiography, chest digital tomosynthesis and low dose MDCT to detect small ground-glass opacity nodules: an anthropomorphic chest phantom study
verfasst von
Kyung Won Doo
Eun-Young Kang
Hwan Seok Yong
Soo-Youn Ham
Ki Yeol Lee
Ji Yung Choo
Publikationsdatum
01.12.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 12/2014
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-014-3376-6

Weitere Artikel der Ausgabe 12/2014

European Radiology 12/2014 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.