Skip to main content
Erschienen in: European Radiology 5/2015

01.05.2015 | Musculoskeletal

Prevalence and type of errors in dual-energy x-ray absorptiometry

verfasst von: Carmelo Messina, Michele Bandirali, Luca Maria Sconfienza, Nathascja Katia D’Alonzo, Giovanni Di Leo, Giacomo Davide Edoardo Papini, Fabio Massimo Ulivieri, Francesco Sardanelli

Erschienen in: European Radiology | Ausgabe 5/2015

Einloggen, um Zugang zu erhalten

Abstract

Objectives

Pitfalls in dual-energy x-ray absorptiometry (DXA) are common. Our aim was to assess rate and type of errors in DXA examinations/reports, evaluating a consecutive series of DXA images of patients examined elsewhere and later presenting to our institution for a follow-up DXA.

Methods

After ethics committee approval, a radiologist retrospectively reviewed all DXA images provided by patients presenting at our institution for a new DXA. Errors were categorized as patient positioning (PP), data analysis (DA), artefacts and/or demographics.

Results

Of 2,476 patients, 1,198 had no previous DXA, while 793 had a previous DXA performed in our institution. The remaining 485 (20 %) patients entered the study (38 men and 447 women; mean age ± standard deviation, 68 ± 9 years). Previous DXA examinations were performed at a total of 37 centres. Of 485 reports, 451 (93 %) had at least one error out of a total of 558 errors distributed as follows: 441 (79 %) were DA, 66 (12 %) PP, 39 (7 %) artefacts and 12 (2 %) demographics.

Conclusions

About 20 % of patients did not undergo DXA at the same institution as previously. More than 90 % of DXA presented at least one error, mainly of DA. International Society for Clinical Densitometry guidelines are very poorly adopted.

Key Points

More than 90 % of DXA examinations/reports presented one or more errors.
About 80 % of errors are related to image data analysis.
Errors in DXA examinations may have potential implications for patients’ management.
Literatur
1.
Zurück zum Zitat Consensus Development Conference (1993) Diagnosis, prophylaxis, and treatment of osteoporosis. Am J Med 94:646–650CrossRef Consensus Development Conference (1993) Diagnosis, prophylaxis, and treatment of osteoporosis. Am J Med 94:646–650CrossRef
2.
Zurück zum Zitat Kanis JA, McCloskey EV, Johansson H, Cooper C, Rizzoli R, Reginster JY et al (2013) European guidance for the diagnosis and management of osteoporosis in postmenopausal women. Osteoporos Int 24(1):23–57CrossRefPubMedCentralPubMed Kanis JA, McCloskey EV, Johansson H, Cooper C, Rizzoli R, Reginster JY et al (2013) European guidance for the diagnosis and management of osteoporosis in postmenopausal women. Osteoporos Int 24(1):23–57CrossRefPubMedCentralPubMed
3.
Zurück zum Zitat Kanis JA, Oden A, Johnell O et al (2007) The use of clinical risk factors enhances the performance of BMD in the prediction of hip and osteoporotic fractures in men and women. Osteoporos Int 18(8):1033–1046CrossRefPubMed Kanis JA, Oden A, Johnell O et al (2007) The use of clinical risk factors enhances the performance of BMD in the prediction of hip and osteoporotic fractures in men and women. Osteoporos Int 18(8):1033–1046CrossRefPubMed
5.
Zurück zum Zitat Blake GM, Fogelman (2007) Role of dual-energy x-ray absorptiometry in the diagnosis and treatment of osteoporosis. J Clin Densitom 10(1):102–110CrossRefPubMed Blake GM, Fogelman (2007) Role of dual-energy x-ray absorptiometry in the diagnosis and treatment of osteoporosis. J Clin Densitom 10(1):102–110CrossRefPubMed
6.
Zurück zum Zitat Bandirali M, Sconfienza LM, Aliprandi A et al (2014) In vivo differences among scan modes in bone mineral density measurement at dual-energy x-ray absorptiometry. Radiol Med 119(4):257–260CrossRefPubMed Bandirali M, Sconfienza LM, Aliprandi A et al (2014) In vivo differences among scan modes in bone mineral density measurement at dual-energy x-ray absorptiometry. Radiol Med 119(4):257–260CrossRefPubMed
7.
Zurück zum Zitat El Maghraoui A, Achemlal L, Bezza A (2006) Monitoring of dual-energy x-ray absorptiometry measurement in clinical practice. J Clin Densitom 9(3):281–286CrossRefPubMed El Maghraoui A, Achemlal L, Bezza A (2006) Monitoring of dual-energy x-ray absorptiometry measurement in clinical practice. J Clin Densitom 9(3):281–286CrossRefPubMed
8.
Zurück zum Zitat Delnevo A, Bandirali M, Di Leo G et al (2013) Differences among array, fast array, and high-definition scan modes in bone mineral density measurement at dual-energy x-ray absorptiometry on a phantom. Clin Radiol 68(6):616–619CrossRefPubMed Delnevo A, Bandirali M, Di Leo G et al (2013) Differences among array, fast array, and high-definition scan modes in bone mineral density measurement at dual-energy x-ray absorptiometry on a phantom. Clin Radiol 68(6):616–619CrossRefPubMed
10.
Zurück zum Zitat Watts NB (2004) Fundamentals and pitfalls of bone densitometry using dual-energy x-ray absorptiometry (DXA). Osteoporos Int 15(11):847–854CrossRefPubMed Watts NB (2004) Fundamentals and pitfalls of bone densitometry using dual-energy x-ray absorptiometry (DXA). Osteoporos Int 15(11):847–854CrossRefPubMed
11.
Zurück zum Zitat Garg MK, Kharb S (2013) Dual energy x-ray absorptiometry: pitfalls in measurement and interpretation of bone mineral density. Indian J Endocrinol Metab 17(2):203–210CrossRefPubMedCentralPubMed Garg MK, Kharb S (2013) Dual energy x-ray absorptiometry: pitfalls in measurement and interpretation of bone mineral density. Indian J Endocrinol Metab 17(2):203–210CrossRefPubMedCentralPubMed
12.
Zurück zum Zitat Hologic (2000) QDR series user’s guide. Hologic, Bedford Hologic (2000) QDR series user’s guide. Hologic, Bedford
13.
Zurück zum Zitat Bachrach LK (2000) Dual energy x-ray absorptiometry (DEXA) measurements of bone density and body composition: promise and pitfalls. J Pediatr Endocrinol Metab 13(Suppl):983–988PubMed Bachrach LK (2000) Dual energy x-ray absorptiometry (DEXA) measurements of bone density and body composition: promise and pitfalls. J Pediatr Endocrinol Metab 13(Suppl):983–988PubMed
14.
Zurück zum Zitat Gafni RI, Baron J (2004) Overdiagnosis of osteoporosis in children due to misinterpretation of dual-energy x-ray absorptiometry (DEXA). J Pediatr 144(2):253–257CrossRefPubMed Gafni RI, Baron J (2004) Overdiagnosis of osteoporosis in children due to misinterpretation of dual-energy x-ray absorptiometry (DEXA). J Pediatr 144(2):253–257CrossRefPubMed
15.
Zurück zum Zitat Leonard MB, Propert KJ, Zemel BS, Stallings VA, Feldman HI (1999) Discrepancies in pediatric bone mineral density reference data: potential for misdiagnosis of osteopenia. J Pediatr 135:182–188CrossRefPubMed Leonard MB, Propert KJ, Zemel BS, Stallings VA, Feldman HI (1999) Discrepancies in pediatric bone mineral density reference data: potential for misdiagnosis of osteopenia. J Pediatr 135:182–188CrossRefPubMed
16.
Zurück zum Zitat Prentice A, Parsons TJ, Cole TJ (1994) Uncritical use of bone mineral density in absorptiometry may lead to size-related artifacts in the identification of bone mineral determinants. Am J Clin Nutr 60:837–842PubMed Prentice A, Parsons TJ, Cole TJ (1994) Uncritical use of bone mineral density in absorptiometry may lead to size-related artifacts in the identification of bone mineral determinants. Am J Clin Nutr 60:837–842PubMed
17.
Zurück zum Zitat Preidler KW, White LS, Tashkin J et al (1997) Dual-energy x-ray absorptiometric densitometry in osteoarthritis of the hip. Acta Radiol 38:539–542PubMed Preidler KW, White LS, Tashkin J et al (1997) Dual-energy x-ray absorptiometric densitometry in osteoarthritis of the hip. Acta Radiol 38:539–542PubMed
18.
Zurück zum Zitat Rand T, Seidl G, Kainberger F et al (1997) Impact of spinal degenerative changes on the evaluation of bone mineral density with dual energy x-ray absorptiometry (DXA). Calcif Tissue Int 60(5):430–433CrossRefPubMed Rand T, Seidl G, Kainberger F et al (1997) Impact of spinal degenerative changes on the evaluation of bone mineral density with dual energy x-ray absorptiometry (DXA). Calcif Tissue Int 60(5):430–433CrossRefPubMed
19.
Zurück zum Zitat Muraki S, Yamamoto S, Ishibashi H et al (2004) Impact of degenerative spinal diseases on bone mineral density of the lumbar spine in elderly women. Osteoporos Int 15(9):724–728CrossRefPubMed Muraki S, Yamamoto S, Ishibashi H et al (2004) Impact of degenerative spinal diseases on bone mineral density of the lumbar spine in elderly women. Osteoporos Int 15(9):724–728CrossRefPubMed
20.
Zurück zum Zitat Lekamwasam S, Lenora RS (2003) Effect of leg rotation on hip bone mineral density measurements. J Clin Densitom Winter 6(4):331–336CrossRef Lekamwasam S, Lenora RS (2003) Effect of leg rotation on hip bone mineral density measurements. J Clin Densitom Winter 6(4):331–336CrossRef
21.
Zurück zum Zitat US Preventive Services Task Force (2011) Screening for osteoporosis: US Preventive Services Task Force recommendation statement. Ann Intern Med 154(5):356–364CrossRef US Preventive Services Task Force (2011) Screening for osteoporosis: US Preventive Services Task Force recommendation statement. Ann Intern Med 154(5):356–364CrossRef
Metadaten
Titel
Prevalence and type of errors in dual-energy x-ray absorptiometry
verfasst von
Carmelo Messina
Michele Bandirali
Luca Maria Sconfienza
Nathascja Katia D’Alonzo
Giovanni Di Leo
Giacomo Davide Edoardo Papini
Fabio Massimo Ulivieri
Francesco Sardanelli
Publikationsdatum
01.05.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 5/2015
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-014-3509-y

Weitere Artikel der Ausgabe 5/2015

European Radiology 5/2015 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.