Demonstration of the reproducibility of free-breathing diffusion-weighted MRI and dynamic contrast enhanced MRI in children with solid tumours: a pilot study

verfasst von: Keiko Miyazaki, Neil P. Jerome, David J. Collins, Matthew R. Orton, James A. d’Arcy, Toni Wallace, Lucas Moreno, Andrew D. J. Pearson, Lynley V. Marshall, Fernando Carceller, Martin O. Leach, Stergios Zacharoulis, Dow-Mu Koh

Erschienen in: European Radiology | Ausgabe 9/2015

Abstract

Objectives

The objectives are to examine the reproducibility of functional MR imaging in children with solid tumours using quantitative parameters derived from diffusion-weighted (DW-) and dynamic contrast enhanced (DCE-) MRI.

Methods

Patients under 16-years-of age with confirmed diagnosis of solid tumours (n = 17) underwent free-breathing DW-MRI and DCE-MRI on a 1.5 T system, repeated 24 hours later. DW-MRI (6 b-values, 0-1000 sec/mm2) enabled monoexponential apparent diffusion coefficient estimation using all (ADC0-1000) and only ≥100 sec/mm2 (ADC100-1000) b-values. DCE-MRI was used to derive the transfer constant (Ktrans), the efflux constant (kep), the extracellular extravascular volume (ve), and the plasma fraction (vp), using a study cohort arterial input function (AIF) and the extended Tofts model. Initial area under the gadolinium enhancement curve and pre-contrast T1 were also calculated. Percentage coefficients of variation (CV) of all parameters were calculated.

Results

The most reproducible cohort parameters were ADC100-1000 (CV = 3.26 %), pre-contrast T1 (CV = 6.21 %), and Ktrans (CV = 15.23 %). The ADC100-1000 was more reproducible than ADC0-1000, especially extracranially (CV = 2.40 % vs. 2.78 %). The AIF (n = 9) derived from this paediatric population exhibited sharper and earlier first-pass and recirculation peaks compared with the literature’s adult population average.

Conclusions

Free-breathing functional imaging protocols including DW-MRI and DCE-MRI are well-tolerated in children aged 6 - 15 with good to moderate measurement reproducibility.

Key Points

Diffusion MRI protocol is feasible and well-tolerated in a paediatric oncology population.
DCE-MRI for pharmacokinetic evaluation is feasible and well tolerated in a paediatric oncology population.
Paediatric arterial input function (AIF) shows systematic differences from the adult population-average AIF.
Variation of quantitative parameters from paired functional MRI measurements were within 20 %.
Abkürzungen
ADC
Apparent diffusion coefficient
AIF
Arterial input function
CI
Confidence interval
CV
Coefficient of variation
DCE-MRI
Dynamic contrast enhanced magnetic resonance imaging
DW-MRI
Diffusion-weighted magnetic resonance imaging
GRAPPA
Generalised autocalibrating partially parallel acquisition acceleration
IAUGC
Initial area under the gadolinium curve
MRI
Magnetic resonance imaging
PNET
Primitive neuroendocrine tumour
ROI
Region of interest

Introduction

Development of anti-cancer therapeutics targeted to specific biological pathways, involved in tumour growth and progression, and inducing cytostasis rather than substantial tumour shrinkage, has led to a need for non-invasive biomarkers reporting on drug action and tumour response beyond simple radiological assessment based on lesion size. Improving survival rates of poor-prognosis childhood cancers via clinical introduction of new molecularly targeted anti-cancer therapeutics, through trials incorporating imaging for proof-of-target inhibition or predictive biomarkers, is a priority [13], and will accelerate and improve the paediatric drug development process.
Diffusion-weighted (DW) and Dynamic Contrast-Enhanced (DCE) MRI are imaging-based techniques that can monitor and predict a response to conventional and novel targeted therapeutic agents in clinical trials [417]. DW-MRI provides information on tissue cellularity, integrity of cellular membranes, and tortuosity of the extracellular space. Malignant tumours are usually hypercellular compared with their tissues of origin, and, thus, show a low apparent diffusion coefficient (ADC). DCE-MRI enables the assessment of parameters pertinent to the state of tumour vasculature by tracking the kinetics of an intravenously administered contrast agent. DCE-MRI measurements can be obtained from parameters such as: the volume transfer constant between plasma and extracellular space (Ktrans), the efflux rate constant between extracellular extravascular space and plasma (kep), the fractional volume of extracellular extravascular space per unit volume of tissue (ve), the fractional volume of blood plasma per unit volume of tissue (vp), the initial area under the gadolinium curve over 60 seconds after arrival of contrast agent (IAUGC60), and the longitudinal relaxation time before administration of contrast agent (pre-contrast T1).
While these functional imaging biomarkers have been extensively used in early clinical trials in the adult setting, there is very little information in the paediatric population where, due to the differences in vascular physiology and biology of paediatric tumours, they may be different. There are also important practical issues that make functional measurements more challenging in children, including logistical difficulties, movement during the procedure, and difficulties obtaining intravenous access. Additionally, the rarity of the conditions necessitate multicentre clinical trials, requiring additional validation and quality assurance procedures. For a prospective study of parameter reproducibility – rather than parameter values – it is possible to include a diverse range of pathologies, giving increased recruitment within a cohort where cancer is rare, and increased generality of the reproducibility assessment. Improved knowledge of reproducibility for functional imaging will guide further development and incorporation as exploratory or secondary endpoints in multi-centre phase I/II clinical trials of cancer therapeutics in children, particularly those that have an antiangiogenic effect. Specifically, DCE-MRI and DW-MRI may demonstrate proof-of-mechanism that anti-angiogenics cause changes in tumour vasculature and tumour cellularity. In addition, tumour imaging characteristics at study entry or changes in tumour imaging characteristics early in therapy may be predictive biomarkers for objective response and clinical benefit.
The purpose of this study is to examine the feasibility of performing functional MRI in children with solid tumours by evaluating the reproducibility of quantitative parameters derived from diffusion-weighted (DW-) and dynamic contrast enhanced (DCE-) MRI.

Materials and methods

Patient population

This prospective study was approved by the institutional review board; prior written consent was obtained from each child’s parent/legal guardian, with assent from each child. Inclusion criteria were: patients (a) less than 16 years old, (b) with confirmed diagnosis of a solid tumour, (c) with a measurable target lesion (≥2 cm), and (d) requiring MRI as part of their routine care. Exclusion criteria were patients with: (a) general anaesthesia required for their scans, (b) renal function impairment, (c) previous allergy to contrast, or contraindications to MRI, (d) lung metastases only, and (e) disease sites that may result in substantial artefacts on the DCE-MRI and DW-MRI studies.

MRI studies

Imaging was performed with a 1.5 T Magnetom Avanto system (Siemens Healthcare, Erlangen, Germany) using a phased-array head coil (intra-cranial studies) or a phased-array body coil (extra-cranial studies). DW- and DCE-MRI was performed during the initial routine MRI, and repeated after 24 hours.

Diffusion-weighted MRI

The free-breathing DW-MRI protocol used a multi-slice single-shot echo-planar imaging sequence with: echo time, 75 msec; repetition time, 3500 msec; matrix, 128 × 128 (interpolated to 256 × 256); 24 slices with 5 mm thickness; generalised autocalibrating partially parallel acquisition acceleration (GRAPPA) factor of two; spectral adiabatic inversion-recovery fat suppression, and three signal averages. Six diffusion gradients (b-values: 0, 50, 100, 300, 600, and 1000 sec/mm2) were applied in three orthogonal directions and averaged to provide isotropic trace-weighted images. Total time for DW-MRI was 3 min 30 seconds. The fields of view were 220 × 220 mm2 in the transverse orientation (intra-cranial studies) and 300 × 300 mm2 in the coronal orientation (extra-cranial studies). The central imaging slice was positioned through the centre of the tumour.

Dynamic contrast-enhanced MRI

The free-breathing DCE-MRI protocol consisted of the following:
i.)
A proton density-weighted three-dimensional spoiled gradient-echo sequence with: echo time, 0.95 msec; repetition time, 3.00 msec; matrix, 128 × 128 (interpolated to 256 × 256); 14 partitions with 5 mm thickness; GRAPPA factor of two; flip angle, 3°; and ten signal averages. The DCE-MRI volume was centred on the DW-MRI volume.
 
ii.)
A dynamic T1-weighted acquisition with identical parameters, except for a flip angle of 16°, and one signal average. Eighty volumes at 3.23 seconds each were acquired in approximately 4 minutes. At the fifth volumetric acquisition, gadolinium-based contrast agent (single dose, 0.1 mmol/kg) was injected followed by 10 ml of saline. Magnevist® was the contrast agent used initially, but it was changed to Dotarem® following a change in local policy regarding MR contrast agents. In children without an implanted central line, injections were performed using a power injector through a peripherally-inserted intravenous cannula. The flow rate varied between 1–3 ml/sec appropriate to the cannula. A number (n = 4) of patients had a Hickman-type central line in place; to avoid an additional invasive procedure in these children, contrast was delivered manually into the central line via a three-way tap by an expert radiologist (D.M.K).
 
iii.)
The sequence in i.) was repeated following the dynamic acquisition, to allow subsequent conversion of signal intensity to contrast agent concentration [18, 19]. Total time for DCE-MRI was 6 minutes.
 
Patients were imaged twice, 24 hours apart without treatment intervention, using the same imaging and injection protocols.

Image analysis

Images were assessed and regions-of-interest (ROIs) were drawn by an expert radiologist (D.M.K); ROIs were drawn around the tumour for three central slices of the imaging volume, and in the matching slices of the repeat study. Data processing to derive functional parameters was performed offline by a postdoctoral research fellow experienced (6 years) in DW- and DCE-MRI studies. DW-MRI analysis was performed offline using ADEPT software (The Institute of Cancer Research, London, UK). Apparent diffusion coefficient values (ADC, 10-6 mm2/sec) were calculated using Levenberg-Marquardt mono-exponential fitting with signal intensities from: (i) all b-values (0, 50, 100, 300, 600, and 1000 sec/mm2, ‘ADC0-1000’) and (ii) b-values ≥100 sec/mm2 (100, 300, 600, and 1000 sec/mm2, ‘ADC100-1000’) on a voxel-by-voxel basis.
DCE-MRI data processing was performed off-line using MRIW software (The Institute of Cancer Research, London, UK), using the same slices and ROIs as for the DW-MRI. The proton-density weighted images acquired post-contrast were used with the dynamically acquired T1-weighted images to generate contrast agent concentrations on a per-voxel basis [18, 19]. Relaxivities of Magnevist® and Dotarem® at 1.5 T were taken to be 4.3 and 4.2 mM-1 sec-1, respectively. The model-independent parameters evaluated were: (i) IAUGC60, in mM.sec, and (ii) the pre-contrast T1, in seconds. Pharmacokinetic model analysis was performed using an extended Tofts model and a population-averaged arterial input function (AIF), measured from a subset of the study cohort where a suitable ROI could be drawn along the descending aorta on or near the central partition (Fig. 1a). Dynamic signal intensities averaged over the ROI were converted to contrast agent concentrations as for the lesion data, and an empirical input function model consisting of components describing the first pass, second pass, and equilibrium phases was fitted to the data [20, 21]:
$$ {C}_p(t) = {C}_B(t)\otimes {R}_M(t)+{C}_R\left(t-{t}_R\right)+{C}_R\left(t-{t}_R\right)\otimes {R}_E(t), $$
(1)
where C B (t) models dispersion in the lungs, C R (t) describes the recirculation phase with a delay t R , and both are modelled with raised cosine functions [22]. R M (t) is an impulse response modelling the mixing through the heart, given by R M (t) = α M  exp(−μ M t) , and R E (t) is an impulse response modelling reflux of contrast from the whole-body extra-vascular space: R E (t) = α E  exp(−μ E t). The input function is thus defined by eight parameters: aB, μB, μM (first pass phase), aR, μR, tR (second pass phase), aE and μE (equilibrium phase). A population-averaged paediatric AIF was constructed by taking the median of the individual AIF parameters after accounting for variations in haematocrit measured in individual patients. The DCE-MRI model-dependent parameters evaluated were: (i) Ktrans, in min-1, (ii) kep, in min-1, (iii) ve, and (iv) vp.

Statistical analysis

For each parameter, the results from voxels in the three analysed slices were combined, and the median parameter value was used in analysis of reproducibility. For model-derived DCE-MRI parameters, values from non-enhancing voxels (where post-onset signal intensities stay within one standard deviation of the pre-contrast mean signal intensity) were not included. The time required for post-processing (performed offline on a laptop, 2.4 GHz processor, 8 GB RAM) varied directly with the size of the tumour ROIs, from approximately 20 seconds to 14 minutes (DCE-MRI) and 10 seconds to 6.5 minutes (DW-MRI) for the smallest and largest tumours, respectively. Baseline variability between repeat median parameters was assessed by calculating the coefficient of variation (CV) and 95 % confidence interval (CI) limits using log-transformed measurement values for: (i) intra-cranial, (ii) extra-cranial, and (iii) combined cohorts.

Results

The study cohort comprised 17 patients with solid tumours (eight intracranial, nine extracranial tumours) recruited between January 2010 and August 2013. Median patient age was 11 years (range 6–15 years). Patient characteristics and primary tumour classification are summarised in Table 1.
Table 1
Patient characteristics and primary tumour classification
 
Sex/Age
Pathology
Intracranial tumour
 1
F/8
Anaplastic astrocytoma
 2
M/7
Primitive neuroectodermal tumour
 3
M/10
Glioblastoma multiforme
 4
M/11
High grade glioma
 5
F/9
Glioblastoma multiforme
 6
M/8
Glioblastoma multiforme
 7
M/15
Anaplastic astrocytoma
 8
M/11
Astrocytoma
Extracranial tumour
 9
M/7
Ganglioneuroblastoma
 10
M/13
Spindle cell sarcoma
 11
F/12
Ganglioneuroblastoma
 12
M/14
Rhabdomyosarcoma
 13
M/15
Sacral myxopapillary ependymoma
 14
M/12
Intra-abdominal primitive neuroectodermal tumour
 15
M/6
Neuroblastoma
 16
M/13
Rhabdomyosarcoma
 17
M/14
Neuroendocrine tumour
All patients were cooperative and tolerated the free-breathing imaging protocol well. One patient did not return for a repeat scan owing to logistical difficulties. DW-MRI data in one patient suffered technical failure. Tumours in four patients did not exhibit contrast agent uptake (intracranial: anaplastic astrocytoma and thalamic high-grade glioma; and extracranial: intra-abdominal PNET and neuroblastoma stage 4). Reproducibility values of the DW-MRI parameters were, thus, analysed using 15 pairs of measurements (seven intracranial, eight extracranial), and that of DCE-MRI parameters using 12 pairs of measurements (five intracranial, seven extracranial).
Nine study-specific, individual AIFs were obtained from DCE-MRI. The cohort-averaged paediatric AIF is shown in Fig. 1b together with an adult population-averaged AIF refitted to the input function model in Eq. 1 [20, 23] with an assumed haematocrit of 0.42. First-pass and recirculation peaks were found to be sharper and to occur earlier in the paediatric AIF; parameters for the two population-averaged AIFs are given in Table 2.
Table 2
Summary of input function model parameters [21] for the population-averaged adult and paediatric arterial input functions
Input function parameters
Adult
Paediatric
First-pass parameters
aB (mM)
60.7
86.5
μB (min-1)
24.8
65.9
μM (min-1)
23.4
13.3
Second-pass parameters
aR (mM)
4.96
8.19
μR (min-1)
9.48
32.0
tR (min)
0.0943
0.209
Equilibrium phase parameters
aE (mM)
25.4
84.3
μE (min-1)
0.169
0.179
The coefficients of variation and 95 % CI limits for all imaging parameters are summarised in Table 3. The most reproducible DW-MRI and DCE-MRI parameters for the full cohort were ADC100-1000 (CV = 3.26 %), pre-contrast T1 (CV = 6.21 %), and Ktrans (CV = 15.23 %). The ADC100-1000 was found to be more reproducible than ADC0-1000, especially extracranially (CV = 2.40 % vs. 2.78 %).
Table 3
Reproducibility values of DW-MR imaging and DCE-MR imaging parameters
 
Coefficient of Variation (%), 95 % confidence interval limits in parentheses
DW-MRI parameters
Intra-cranial (n = 7)
Extra-cranial (n = 8)
Intra- and extra-cranial (n = 15)
 ADC0-1000
3.92 (-7.4, 8.0)
2.78 (-5.3, 5.6)
3.74 (-7.1, 7.6)
 ADC100-1000
4.09 (-7.7, 8.4)
2.40 (-4.6, 4.8)
3.26 (-6.2, 6.6)
DCE-MRI parameters
Intracranial (n = 5)
Extracranial (n = 7)
Intracranial and extracranial (n = 12)
 Pre-contrast T1
7.99 (-14.5, 16.9)
5.19 (-9.7, 10.7)
6.21 (-11.5, 12.9)
 IAUGC60
9.38 (-16.8, 20.1)
11.71 (-20.5, 25.7)
12.77 (-22.1, 28.3)
 Ktrans
13.58 (-23.3, 30.3)
16.79 (-27.9, 38.7)
15.23 (-25.7, 34.5)
 kep
21.74 (-34.4, 52.4)
19.74 (-31.8, 46.7)
19.60 (-31.7, 46.3)
 ve
20.05 (-32.2, 47.6)
17.48 (-28.8, 40.5)
18.56 (-30.3, 43.4)
 vp
50.73 (-60.9, 155.5)
16.29 (-27.2, 37.3)
36.24 (-49.8, 99.1)
Example ADC maps and mono-exponential curve fits for ADC0-1000 and ADC100-1000 from intracranial and extracranial tumour patients are shown in Figs. 2 and 3, respectively. The IAUGC60 and Ktrans maps and contrast agent uptake curves (same patients) are shown in Figs. 4 and 5.

Discussion

Functional imaging has the potential to provide imaging biomarkers for proof-of-mechanism for angiogenesis inhibitors, and to identify those patients more likely to respond to a given therapy, as well as providing more physiological sensitivity when assessing post-treatment response.
The range and specificity of available functional imaging modalities allow improved characterisation of spatial differences in biological properties both within and between tumours, though at the cost of lengthened imaging studies. Paediatric MRI is particularly challenging, since children may not lie still during the entire imaging protocol, find the noise and confined space distressing, or may be unable to cooperate with breath-holding instructions intended to minimise abdominal motion artefacts as used with adults.
Despite the challenges involved, there is increasing use of functional imaging in children with intracranial tumours, as summarised by Peet et al. [24]. There are, however, still very few reports of functional imaging studies in children with extracranial tumours. Despite this paucity, there are studies that report the potential of DW- and DCE-MRI biomarkers for disease characterisation [25, 26] and response assessment in various paediatric oncological settings. Rodriguez-Gutierrez et al., evaluated serial DW-MRI to predict treatment response in high-grade paediatric brain tumours and found that responders exhibited a higher regional ADC increase [27]. Guo et al., performed DCE-MRI in children with newly diagnosed, non-metastatic osteosarcoma treated on a phase 2 trial (NCT001456390) [28], finding DCE-MRI derived parameters were potential early prognostic factors for event-free and overall survival. Recently, Navid et al., published the results of a phase I and clinical pharmacology study of bevacizumab, sorafenib, and low-dose cyclophosphamide in children and young adults with refractory/recurrent extracranial solid tumours [29]; both groups of study patients exhibited a rapid decrease in Ktrans and vp in the first 7 days after treatment initiation. Such results demonstrate the emerging roles of functional MR imaging markers for assessing and predicting treatment response in children with cancer, and their potential contribution to the development of stratified treatment regimens.
Baseline reproducibility values of the functional MR parameters are important measures of consistency and reliability that should be evaluated. Several studies have investigated the reproducibility of DW- and DCE-MRI derived parameters in adults [10, 12, 30]; given the added challenges when imaging children, arising from both logistical and physiological differences, reproducibility should be investigated specifically for this cohort.
In this present study functional MR imaging, repeated following 24 hours without treatment intervention, was performed in a paediatric cohort (6 to 15 years-of-age) to assess the reproducibility of the derived parameters. All seventeen children who participated in the study were able to cooperate throughout the entire imaging protocol, including injections of contrast agent and saline flush. The quality of data obtained allowed DW-MRI and DCE-MRI model fitting on a voxel-by-voxel basis to generate parametric maps, with parameter reproducibility values comparable to those achieved in adult cohorts [12, 30]. The diversity of tumours present in the cohort adds to the generality of the result, with both extracranial and intracranial tumour subgroups presenting similar coefficients of variation.
Whole cohort ADC reproducibility was found to be better when excluding the two lowest b-values in the mono-exponential fitting procedure, compared to using all b-values; this difference was also present for the extracranial tumour cohort, suggesting that fitting a mono-exponential model for all b-values results in ADC measures that will be biased by the lower b-value data points. The curve fits shown in Figs. 2 and 3 clearly illustrate this bias. The use of a bi-exponential model with “slow” and “fast” diffusion components arising from an optimised diffusion protocol may be more informative, as well as better reflecting the properties of specific tumour types, and should be explored.
For DCE-MRI measurements, we employed a 3-D volumetric protocol with good spatial and temporal resolutions. The dynamic temporal resolution employed (~3 s) not only helped to minimise motion artefacts but also helped to capture the contrast uptake curves in the tumour and the descending aorta (where signal changes occur rapidly). Using the contrast uptake curves from the descending aorta, it was possible to construct a paediatric population AIF (Fig. 1b), observed to have features distinct from those seen in an adult population [23] and consistent with the relatively high rate of circulation seen in children. Although limited patient numbers preclude investigation of AIF variations with age in this present study, the differences observed between the paediatric and adult population AIFs highlight the importance of conducting such investigations in the future. Additionally, it is important to optimise the injection protocol in patients with an implanted central venous line to minimise the variability observed with hand injections [20].
Pre-contrast T1 was found to be a robust parameter with the best reproducibility (CV = 6.21 %). This parameter is used in the conversion of signal intensity to contrast agent concentration for quantitative DCE-MRI data analysis, but it is also a potential marker for treatment response [31, 32]. There is a consensus that IAUGC60 and Ktrans should be used as quantitative endpoints for DCE-MRI when used in the development of anti-angiogenic and anti-vascular agents [33, 34], with a recent report on DCE-MRI quantification supporting a CV of less than 20 % for these parameters [35]. In our study, the CV of IAUGC60 and Ktrans for the whole cohort were 12.77 % and 15.23 %, respectively. The reproducibility of other DCE-MRI derived parameters ranged between 12.8 to 19.6 % except for vp for the whole cohort (36.24 %). It is interesting that the DCE-MRI parameters generally expressed a higher variability than those from DW-MRI, which may reflect either additional complexities of administering exogenous contrast or, given that the most reproducible DCE-MRI parameters were model-independent, the inherent difficulty in modelling a complex process.
There are several limitations to this study. Firstly, the number of patients involved in the study is small (recruitment of n = 17 was completed over 3.5 years) as patients were asked to undergo a second MRI research examination. This reflects the ethical and logistical challenges of research involving children and emphasises the importance of multi-centre collaboration to increase recruitment. The small cohort, and, therefore, limited numbers for the range of tumours represented, restricts the conclusions that can be drawn about specific tumour types, though functional parameter reproducibility is more dependent on factors arising from tumour location, imaging set-up, and acquisition parameters than from lesion type. Secondly, a population-averaged AIF for pharmacokinetic modelling of DCE-MRI data may mask differences arising from true physiological variations. Obtaining a study-specific AIF, however, is a well-documented challenge; in our experience, it was not always possible to include an artery in the central partitions of the imaging volume. Therefore, using a population-averaged AIF was a pragmatic solution for this present study. Wang et al., have shown that it is reasonable and practical to use a limited-population-based average AIF for pharmacokinetic modelling of osteosarcoma DCE-MRI data from a large population when it is not possible to measure every individual AIF [36]. Thirdly, we have not included younger children requiring sedation or general anaesthesia for their examinations, due to the ethical challenges involved in performing repeated sedation solely for research purposes.
In conclusion, this study has demonstrated that a free-breathing protocol including diffusion-weighted and dynamic contrast-enhanced MR imaging in children aged between 6 and 15-years-old is feasible and well-tolerated, and that reproducible functional parameters can be obtained. The non-invasive nature of such imaging makes this approach particularly attractive for use in a paediatric population. Findings of this pilot study will support the incorporation of DW- and DCE- MRI in paediatric phase I-II clinical trials of new molecularly targeted agents, particularly those targeting VEGF/VEGFR and other angiogenesis pathways.

Acknowledgments

The scientific guarantor of this publication is Prof. Martin Leach. The authors of this manuscript declare no relationships with any companies, whose products or services may be related to the subject matter of the article. This study has received funding by CR UK and EPSRC in association with the Medical Research Council and Department of Health (England) grant C1060/A10334, and NHS funding to the NIHR Biomedical Research Centre and the Clinical Research Facility in Imaging. Support also received for the CR UK and EPSRC Paediatric Imaging Programme C7809/A10342. Lucas Moreno and Lynley Marshall are funded by the Oak Foundation. ADJP is supported by Cancer Research UK (programme grant C1178/A10294) – Chair in Paediatric Oncology. We acknowledge Experimental Cancer Medicine Centre (ECMC) Network funding for support to early clinical trials. No complex statistical methods were necessary for this paper. Institutional Review Board approval was obtained. Written informed consent was obtained from all subjects (patients) in this study. Methodology: prospective, experimental, performed at one institution.
Open Access This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Radiologie

Kombi-Abonnement

Mit e.Med Radiologie erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes Radiologie, den Premium-Inhalten der radiologischen Fachzeitschriften, inklusive einer gedruckten Radiologie-Zeitschrift Ihrer Wahl.

Literatur
1.
Zurück zum Zitat Norris RE, Adamson PC (2012) Challenges and opportunities in childhood cancer drug development. Nat Rev Cancer 12:776–782 Norris RE, Adamson PC (2012) Challenges and opportunities in childhood cancer drug development. Nat Rev Cancer 12:776–782
2.
Zurück zum Zitat Vassal G, Zwaan CM, Ashley D, Le Deley MC, Hargrave D, Blanc P et al (2013) New drugs for children and adolescents with cancer: the need for novel development pathways. Lancet Oncol 14:e117–e124 Vassal G, Zwaan CM, Ashley D, Le Deley MC, Hargrave D, Blanc P et al (2013) New drugs for children and adolescents with cancer: the need for novel development pathways. Lancet Oncol 14:e117–e124
3.
Zurück zum Zitat Boklan J (2006) Little patients, losing patience: pediatric cancer drug development. Mol Cancer Ther 5:1905–1908 Boklan J (2006) Little patients, losing patience: pediatric cancer drug development. Mol Cancer Ther 5:1905–1908
4.
Zurück zum Zitat Chang Y-C, Yu C-J, Chen C-M, Hu F-C, Hsu H-H, Tseng W-YI et al (2012) Dynamic contrast-enhanced MRI in advanced nonsmall-cell lung cancer patients treated with first-line bevacizumab, gemcitabine, and cisplatin. J Magn Reson Imaging JMRI 36:387–396 Chang Y-C, Yu C-J, Chen C-M, Hu F-C, Hsu H-H, Tseng W-YI et al (2012) Dynamic contrast-enhanced MRI in advanced nonsmall-cell lung cancer patients treated with first-line bevacizumab, gemcitabine, and cisplatin. J Magn Reson Imaging JMRI 36:387–396
5.
Zurück zum Zitat Chase DM, Sill MW, Monk BJ, Chambers MD, Darcy KM, Han ES et al (2012) Changes in tumour blood flow as measured by Dynamic Contrast-Enhanced Magnetic Resonance Imaging (DCE-MRI) may predict activity of single agent bevacizumab in recurrent epithelial ovarian (EOC) and primary peritoneal cancer (PPC) patients: an exploratory a. Gynecol Oncol 126:375–380 Chase DM, Sill MW, Monk BJ, Chambers MD, Darcy KM, Han ES et al (2012) Changes in tumour blood flow as measured by Dynamic Contrast-Enhanced Magnetic Resonance Imaging (DCE-MRI) may predict activity of single agent bevacizumab in recurrent epithelial ovarian (EOC) and primary peritoneal cancer (PPC) patients: an exploratory a. Gynecol Oncol 126:375–380
6.
Zurück zum Zitat De Bruyne S, Van Damme N, Smeets P, Ferdinande L, Ceelen W, Mertens J et al (2012) Value of DCE-MRI and FDG-PET/CT in the prediction of response to preoperative chemotherapy with bevacizumab for colorectal liver metastases. Br J Cancer 106:1926–1933 De Bruyne S, Van Damme N, Smeets P, Ferdinande L, Ceelen W, Mertens J et al (2012) Value of DCE-MRI and FDG-PET/CT in the prediction of response to preoperative chemotherapy with bevacizumab for colorectal liver metastases. Br J Cancer 106:1926–1933
7.
Zurück zum Zitat Desar IME, Ter Voert EGW, Hambrock T, Van Asten JJ, Van Spronsen DJ, Mulders PF et al (2011) Functional MRI techniques demonstrate early vascular changes in renal cell cancer patients treated with sunitinib: a pilot study. Cancer Imaging Off Publ Int Cancer Imaging Soc 11:259–265 Desar IME, Ter Voert EGW, Hambrock T, Van Asten JJ, Van Spronsen DJ, Mulders PF et al (2011) Functional MRI techniques demonstrate early vascular changes in renal cell cancer patients treated with sunitinib: a pilot study. Cancer Imaging Off Publ Int Cancer Imaging Soc 11:259–265
8.
Zurück zum Zitat Hirashima Y, Yamada Y, Tateishi U, Kato K, Miyake M, Horita Y et al (2012) Pharmacokinetic parameters from 3-Tesla DCE-MRI as surrogate biomarkers of antitumour effects of bevacizumab plus FOLFIRI in colorectal cancer with liver metastasis. Int J Cancer 130:2359–2365 Hirashima Y, Yamada Y, Tateishi U, Kato K, Miyake M, Horita Y et al (2012) Pharmacokinetic parameters from 3-Tesla DCE-MRI as surrogate biomarkers of antitumour effects of bevacizumab plus FOLFIRI in colorectal cancer with liver metastasis. Int J Cancer 130:2359–2365
9.
Zurück zum Zitat Jain R, Scarpace LM, Ellika S, Torcuator R, Schultz LR, Hearshen D et al (2010) Imaging response criteria for recurrent gliomas treated with bevacizumab: role of diffusion weighted imaging as an imaging biomarker. J Neuro-Oncol 96:423–431 Jain R, Scarpace LM, Ellika S, Torcuator R, Schultz LR, Hearshen D et al (2010) Imaging response criteria for recurrent gliomas treated with bevacizumab: role of diffusion weighted imaging as an imaging biomarker. J Neuro-Oncol 96:423–431
10.
Zurück zum Zitat Koh D-M, Blackledge M, Collins DJ, Padhani AR, Wallace T, Wilton B et al (2009) Reproducibility and changes in the apparent diffusion coefficients of solid tumours treated with combretastatin A4 phosphate and bevacizumab in a two-centre phase I clinical trial. Eur Radiol 19:2728–2738 Koh D-M, Blackledge M, Collins DJ, Padhani AR, Wallace T, Wilton B et al (2009) Reproducibility and changes in the apparent diffusion coefficients of solid tumours treated with combretastatin A4 phosphate and bevacizumab in a two-centre phase I clinical trial. Eur Radiol 19:2728–2738
11.
Zurück zum Zitat Kummar S, Gutierrez ME, Chen A, Turkbey IB, Allen D, Horneffer YR et al (2011) Phase I trial of vandetanib and bevacizumab evaluating the VEGF and EGF signal transduction pathways in adults with solid tumours and lymphomas. Eur J Cancer 47:997–1005 Kummar S, Gutierrez ME, Chen A, Turkbey IB, Allen D, Horneffer YR et al (2011) Phase I trial of vandetanib and bevacizumab evaluating the VEGF and EGF signal transduction pathways in adults with solid tumours and lymphomas. Eur J Cancer 47:997–1005
12.
Zurück zum Zitat Messiou C, Orton M, Collins DJ, Morgan VA, Mears D, Ghiorghiu D et al (2012) Advanced solid tumours treated with cediranib: comparison of dynamic contrast-enhanced MR imaging and CT as markers of vascular activity 1. Radiology 265(2):426–36PubMedCrossRef Messiou C, Orton M, Collins DJ, Morgan VA, Mears D, Ghiorghiu D et al (2012) Advanced solid tumours treated with cediranib: comparison of dynamic contrast-enhanced MR imaging and CT as markers of vascular activity 1. Radiology 265(2):426–36PubMedCrossRef
13.
Zurück zum Zitat Miyazaki K, Orton M, Davidson R (2012) Neuroendocrine tumour liver metastases: use of dynamic contrast-enhanced MR imaging to monitor and predict radiolabeled octreotide therapy response. Radiology 263:139–148 Miyazaki K, Orton M, Davidson R (2012) Neuroendocrine tumour liver metastases: use of dynamic contrast-enhanced MR imaging to monitor and predict radiolabeled octreotide therapy response. Radiology 263:139–148
14.
Zurück zum Zitat O’Connor JPB, Rose CJ, Jackson A, Watson Y, Cheung S, Maders F et al (2011) DCE-MRI biomarkers of tumour heterogeneity predict CRC liver metastasis shrinkage following bevacizumab and FOLFOX-6. Br J Cancer 105:139–145 O’Connor JPB, Rose CJ, Jackson A, Watson Y, Cheung S, Maders F et al (2011) DCE-MRI biomarkers of tumour heterogeneity predict CRC liver metastasis shrinkage following bevacizumab and FOLFOX-6. Br J Cancer 105:139–145
15.
Zurück zum Zitat Pope WB, Qiao XJ, Kim HJ, Lai A, Nghiemphu P, Xue X et al (2012) Apparent diffusion coefficient histogram analysis stratifies progression-free and overall survival in patients with recurrent GBM treated with bevacizumab: a multi-center study. J Neuro-Oncol 108:491–498 Pope WB, Qiao XJ, Kim HJ, Lai A, Nghiemphu P, Xue X et al (2012) Apparent diffusion coefficient histogram analysis stratifies progression-free and overall survival in patients with recurrent GBM treated with bevacizumab: a multi-center study. J Neuro-Oncol 108:491–498
16.
Zurück zum Zitat Yoo DS, Kirkpatrick JP, Craciunescu O, Broadwater G, Peterson BL, Carroll MD et al (2012) Prospective trial of synchronous bevacizumab, erlotinib, and concurrent chemoradiation in locally advanced head and neck cancer. Clin Cancer Res Off J Am Assoc Cancer Res 18:1404–1414 Yoo DS, Kirkpatrick JP, Craciunescu O, Broadwater G, Peterson BL, Carroll MD et al (2012) Prospective trial of synchronous bevacizumab, erlotinib, and concurrent chemoradiation in locally advanced head and neck cancer. Clin Cancer Res Off J Am Assoc Cancer Res 18:1404–1414
17.
Zurück zum Zitat Yopp A, Schwartz L, Kemeny N (2011) Antiangiogenic therapy for primary liver cancer: correlation of changes in dynamic contrast-enhanced magnetic resonance imaging with tissue hypoxia markers and clinical response. Ann Surg Oncol 18:2192–2199 Yopp A, Schwartz L, Kemeny N (2011) Antiangiogenic therapy for primary liver cancer: correlation of changes in dynamic contrast-enhanced magnetic resonance imaging with tissue hypoxia markers and clinical response. Ann Surg Oncol 18:2192–2199
18.
Zurück zum Zitat Miyazaki K, D’Arcy JA, Orton MR, Koh D-M, Collins DJ, Leach MO (2011) Improved T1 quantification using post-Gd contrast variable flip angle data. International Society of Magnetic Resonance in Medicine. p 1092 Miyazaki K, D’Arcy JA, Orton MR, Koh D-M, Collins DJ, Leach MO (2011) Improved T1 quantification using post-Gd contrast variable flip angle data. International Society of Magnetic Resonance in Medicine. p 1092
19.
Zurück zum Zitat De Bruin P, Versluis M, Yusuf E, Reignierse M, Watt I, Van Osch M (2010) Accuracy of T1-Fitting for Pharmacokinetic Analysis of Dynamic Contrast-Enhanced MRI. International Society of Magnetic Resonance in Medicine. p 1720 De Bruin P, Versluis M, Yusuf E, Reignierse M, Watt I, Van Osch M (2010) Accuracy of T1-Fitting for Pharmacokinetic Analysis of Dynamic Contrast-Enhanced MRI. International Society of Magnetic Resonance in Medicine. p 1720
20.
Zurück zum Zitat Miyazaki K, Orton MR, Collins DJ, d’Arcy JA, Wallace T, Moreno L et al (2013) Preliminary analysis of arterial input function derived from dynamic contrast enhanced MRI in children with cancer. International Society of Magnetic Resonance in Medicine. p 720 Miyazaki K, Orton MR, Collins DJ, d’Arcy JA, Wallace T, Moreno L et al (2013) Preliminary analysis of arterial input function derived from dynamic contrast enhanced MRI in children with cancer. International Society of Magnetic Resonance in Medicine. p 720
21.
Zurück zum Zitat Orton MR, Collins DJ, Messiou C, Castellano E, Tessier J, Spratt S et al (2010) A New Vascular Impulse Response Function for Modelling and Prediction with Measured Dynamic Contrast Enhanced Plasma Curves. International Society of Magnetic Resonance in Medicine. p 1726 Orton MR, Collins DJ, Messiou C, Castellano E, Tessier J, Spratt S et al (2010) A New Vascular Impulse Response Function for Modelling and Prediction with Measured Dynamic Contrast Enhanced Plasma Curves. International Society of Magnetic Resonance in Medicine. p 1726
22.
Zurück zum Zitat Orton MR, d’Arcy JA, Walker-Samuel S, Hawkes DJ, Atkinson D, Collins DJ et al (2008) Computationally efficient vascular input function models for quantitative kinetic modelling using DCE-MRI. Phys Med Biol 53:1225–1239 Orton MR, d’Arcy JA, Walker-Samuel S, Hawkes DJ, Atkinson D, Collins DJ et al (2008) Computationally efficient vascular input function models for quantitative kinetic modelling using DCE-MRI. Phys Med Biol 53:1225–1239
23.
Zurück zum Zitat Parker GJM, Roberts C, Macdonald A, Buonaccorsi G, Cheung S, Buckley DL et al (2006) Experimentally-derived functional form for a population-averaged high-temporal-resolution arterial input function for dynamic contrast-enhanced MRI. Magn Reson Med Off J Soc Magn Res Med/Soc Magn Reson Med 56:993–1000 Parker GJM, Roberts C, Macdonald A, Buonaccorsi G, Cheung S, Buckley DL et al (2006) Experimentally-derived functional form for a population-averaged high-temporal-resolution arterial input function for dynamic contrast-enhanced MRI. Magn Reson Med Off J Soc Magn Res Med/Soc Magn Reson Med 56:993–1000
24.
Zurück zum Zitat Peet AC, Arvanitis TN, Leach MO, Waldman AD (2012) Functional imaging in adult and paediatric brain tumours. Nat Rev Clin Oncol 9:700–711 Peet AC, Arvanitis TN, Leach MO, Waldman AD (2012) Functional imaging in adult and paediatric brain tumours. Nat Rev Clin Oncol 9:700–711
25.
Zurück zum Zitat Jost SC, Ackerman JW, Garbow JR, Manwaring LP, Gutmann DH, McKinstry RC (2008) Diffusion-weighted and dynamic contrast-enhanced imaging as markers of clinical behavior in children with optic pathway glioma. Pediatr Radiol 38:1293–1299 Jost SC, Ackerman JW, Garbow JR, Manwaring LP, Gutmann DH, McKinstry RC (2008) Diffusion-weighted and dynamic contrast-enhanced imaging as markers of clinical behavior in children with optic pathway glioma. Pediatr Radiol 38:1293–1299
26.
Zurück zum Zitat Gahr N, Darge K, Hahn G, Kreher BW, Von Buiren M, Uhl M (2011) Diffusion-weighted MRI for differentiation of neuroblastoma and ganglioneuroblastoma/ganglioneuroma. Eur J Radiol 79:443–446 Gahr N, Darge K, Hahn G, Kreher BW, Von Buiren M, Uhl M (2011) Diffusion-weighted MRI for differentiation of neuroblastoma and ganglioneuroblastoma/ganglioneuroma. Eur J Radiol 79:443–446
27.
Zurück zum Zitat Rodriguez Gutierrez D, Manita M, Jaspan T, Dineen R, Grundy RG, Auer DP (2013) Serial MR diffusion to predict treatment response in high-grade pediatric brain tumors: a comparison of regional and voxel-based diffusion change metrics. Neuro Oncol 15:981–989 Rodriguez Gutierrez D, Manita M, Jaspan T, Dineen R, Grundy RG, Auer DP (2013) Serial MR diffusion to predict treatment response in high-grade pediatric brain tumors: a comparison of regional and voxel-based diffusion change metrics. Neuro Oncol 15:981–989
28.
Zurück zum Zitat Guo J, Reddick WE, Glass JO, Ji Q, Billups C, Wu J et al (2012) Dynamic contrast-enhanced magnetic resonance imaging as a prognostic factor in predicting event-free and overall survival in pediatric patients with osteosarcoma. Cancer 118:3776–3785 Guo J, Reddick WE, Glass JO, Ji Q, Billups C, Wu J et al (2012) Dynamic contrast-enhanced magnetic resonance imaging as a prognostic factor in predicting event-free and overall survival in pediatric patients with osteosarcoma. Cancer 118:3776–3785
29.
Zurück zum Zitat Navid F, Baker SD, McCarville MB, Stewart CF, Billups C, Wu J et al (2013) Phase I and clinical pharmacology study of bevacizumab, sorafenib, and low-dose cyclophosphamide in children and young adults with refractory/recurrent solid tumors. Clin Cancer Res Off J Am Assoc Cancer Res 19:236–246 Navid F, Baker SD, McCarville MB, Stewart CF, Billups C, Wu J et al (2013) Phase I and clinical pharmacology study of bevacizumab, sorafenib, and low-dose cyclophosphamide in children and young adults with refractory/recurrent solid tumors. Clin Cancer Res Off J Am Assoc Cancer Res 19:236–246
30.
Zurück zum Zitat Nathan P, Zweifel M, Padhani AR, Koh D-M, Ng M, Collins DJ et al (2012) Phase I trial of combretastatin A4 phosphate (CA4P) in combination with bevacizumab in patients with advanced cancer. Clin Cancer Res Off J Am Assoc Cancer Res 18:3428–3439 Nathan P, Zweifel M, Padhani AR, Koh D-M, Ng M, Collins DJ et al (2012) Phase I trial of combretastatin A4 phosphate (CA4P) in combination with bevacizumab in patients with advanced cancer. Clin Cancer Res Off J Am Assoc Cancer Res 18:3428–3439
31.
Zurück zum Zitat Jamin Y, Tucker E, Poon E, Popov S (2013) Evaluation of clinically translatable MR imaging biomarkers of therapeutic response in the TH-MYCN transgenic mouse model of neuroblastoma. Radiol 266:130–140 Jamin Y, Tucker E, Poon E, Popov S (2013) Evaluation of clinically translatable MR imaging biomarkers of therapeutic response in the TH-MYCN transgenic mouse model of neuroblastoma. Radiol 266:130–140
32.
Zurück zum Zitat O’Connor JPB, Carano RAD, Clamp AR, Ross J, Ho CCK, Jackson A et al (2009) Quantifying antivascular effects of monoclonal antibodies to vascular endothelial growth factor: insights from imaging. Clin Cancer Res Off J Am Assoc Cancer Res 15:6674–6682 O’Connor JPB, Carano RAD, Clamp AR, Ross J, Ho CCK, Jackson A et al (2009) Quantifying antivascular effects of monoclonal antibodies to vascular endothelial growth factor: insights from imaging. Clin Cancer Res Off J Am Assoc Cancer Res 15:6674–6682
33.
Zurück zum Zitat Leach MO, Brindle KM, Evelhoch JL, Griffiths JR, Horsman MR, Jackson A et al (2005) The assessment of antiangiogenic and antivascular therapies in early-stage clinical trials using magnetic resonance imaging: issues and recommendations. Br J Cancer 92:1599–1610 Leach MO, Brindle KM, Evelhoch JL, Griffiths JR, Horsman MR, Jackson A et al (2005) The assessment of antiangiogenic and antivascular therapies in early-stage clinical trials using magnetic resonance imaging: issues and recommendations. Br J Cancer 92:1599–1610
34.
Zurück zum Zitat Leach MO, Morgan B, Tofts PS, Buckley DL, Huang W, Horsfield MA et al (2012) Imaging vascular function for early stage clinical trials using dynamic contrast-enhanced magnetic resonance imaging. Eur Radiol 22:1451–1464 Leach MO, Morgan B, Tofts PS, Buckley DL, Huang W, Horsfield MA et al (2012) Imaging vascular function for early stage clinical trials using dynamic contrast-enhanced magnetic resonance imaging. Eur Radiol 22:1451–1464
35.
Zurück zum Zitat Quantitative Imaging Biomarkers Alliance. Profile: DCE MRI Quantification Version 1.6 (2011) Quantitative Imaging Biomarkers Alliance. Profile: DCE MRI Quantification Version 1.6 (2011)
36.
Zurück zum Zitat Wang Y, Huang W, Panicek DM, Schwartz LH, Koutcher JA (2008) Feasibility of using limited-population-based arterial input function for pharmacokinetic modeling of osteosarcoma dynamic contrast-enhanced MRI data. Magn Reson Med Off J Soc Magn Reson Med/Soc Magn Reson Med 59:1183–1189 Wang Y, Huang W, Panicek DM, Schwartz LH, Koutcher JA (2008) Feasibility of using limited-population-based arterial input function for pharmacokinetic modeling of osteosarcoma dynamic contrast-enhanced MRI data. Magn Reson Med Off J Soc Magn Reson Med/Soc Magn Reson Med 59:1183–1189
Metadaten
Titel
Demonstration of the reproducibility of free-breathing diffusion-weighted MRI and dynamic contrast enhanced MRI in children with solid tumours: a pilot study
verfasst von
Keiko Miyazaki
Neil P. Jerome
David J. Collins
Matthew R. Orton
James A. d’Arcy
Toni Wallace
Lucas Moreno
Andrew D. J. Pearson
Lynley V. Marshall
Fernando Carceller
Martin O. Leach
Stergios Zacharoulis
Dow-Mu Koh
Publikationsdatum
01.09.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 9/2015
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-015-3666-7

Weitere Artikel der Ausgabe 9/2015

European Radiology 9/2015 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.