Skip to main content
Erschienen in: European Radiology 2/2016

01.02.2016 | Interventional

Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules

verfasst von: Nicola Rotolo, Chiara Floridi, Andrea Imperatori, Federico Fontana, Anna Maria Ierardi, Monica Mangini, Veronica Arlant, Giuseppe De Marchi, Raffaele Novario, Lorenzo Dominioni, Carlo Fugazzola, Gianpaolo Carrafiello

Erschienen in: European Radiology | Ausgabe 2/2016

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To compare the diagnostic performance of cone-beam CT (CBCT)-guided and CT fluoroscopy (fluoro-CT)-guided technique for transthoracic needle biopsy (TNB) of lung nodules.

Methods

The hospital records of 319 consecutive patients undergoing 324 TNBs of lung nodules in a single radiology unit in 2009–2013 were retrospectively evaluated. The newly introduced CBCT technology was used to biopsy 123 nodules; 201 nodules were biopsied by conventional fluoro-CT-guided technique. We assessed the performance of the two biopsy systems for diagnosis of malignancy and the radiation exposure.

Results

Nodules biopsied by CBCT-guided and by fluoro-CT-guided technique had similar characteristics: size, 20 ± 6.5 mm (mean ± standard deviation) vs. 20 ± 6.8 mm (p = 0.845); depth from pleura, 15 ± 15 mm vs. 15 ± 16 mm (p = 0.595); malignant, 60 % vs. 66 % (p = 0.378). After a learning period, the newly introduced CBCT-guided biopsy system and the conventional fluoro-CT-guided system showed similar sensitivity (95 % and 92 %), specificity (100 % and 100 %), accuracy for diagnosis of malignancy (96 % and 94 %), and delivered non-significantly different median effective doses [11.1 mSv (95 % CI 8.9–16.0) vs. 14.5 mSv (95 % CI 9.5–18.1); p = 0.330].

Conclusion

The CBCT-guided and fluoro-CT-guided systems for lung nodule biopsy are similar in terms of diagnostic performance and effective dose, and may be alternatively used to optimize the available technological resources.

Key Points

CBCT-guided and fluoro-CT-guided lung nodule biopsy provided high and similar diagnostic accuracy.
Effective dose from CBCT-guided and fluoro-CT-guided lung nodule biopsy was similar.
To optimize resources, CBCT-guided lung nodule biopsy may be an alternative to fluoro-CT-guided.
Literatur
1.
Zurück zum Zitat Smith-Bindman R, Miglioretti DL, Johnson E et al (2012) Use of diagnostic imaging studies and associated radiation exposure for patients enrolled in large integrated health care system, 1996–2010. JAMA 307:2400–2409PubMedCrossRef Smith-Bindman R, Miglioretti DL, Johnson E et al (2012) Use of diagnostic imaging studies and associated radiation exposure for patients enrolled in large integrated health care system, 1996–2010. JAMA 307:2400–2409PubMedCrossRef
2.
Zurück zum Zitat Schmidt RL, Witt BL, Lopez-Calderon LE et al (2013) The influence of rapid onsite evaluation on the adequacy rate of fine-needle aspiration cytology. A systematic review and meta-analysis. Am J Clin Pathol 139:300–308PubMedCrossRef Schmidt RL, Witt BL, Lopez-Calderon LE et al (2013) The influence of rapid onsite evaluation on the adequacy rate of fine-needle aspiration cytology. A systematic review and meta-analysis. Am J Clin Pathol 139:300–308PubMedCrossRef
3.
Zurück zum Zitat Priola AM, Priola SM, Cataldi A et al (2007) Accuracy of CT-guided transthoracic needle biopsy of lung lesions: factors affecting diagnostic yield. Radiol Med 112:1142–1159PubMedCrossRef Priola AM, Priola SM, Cataldi A et al (2007) Accuracy of CT-guided transthoracic needle biopsy of lung lesions: factors affecting diagnostic yield. Radiol Med 112:1142–1159PubMedCrossRef
4.
Zurück zum Zitat Tomiyana N, Yasuhara Y, Nakajima Y et al (2006) CT-guided needle biopsy of lung lesions: a survey of severe complication based on 9783 biopsies in Japan. Eur J Radiol 59:60–64CrossRef Tomiyana N, Yasuhara Y, Nakajima Y et al (2006) CT-guided needle biopsy of lung lesions: a survey of severe complication based on 9783 biopsies in Japan. Eur J Radiol 59:60–64CrossRef
5.
Zurück zum Zitat Hiraki T, Mimura H, Gobara H et al (2009) CT fluoroscopy-guided biopsy of 1,000 pulmonary lesions performed with 20-gauge coaxial cutting needles: diagnostic yield and risk factors for diagnostic failure. Chest 136:1612–1617PubMedCrossRef Hiraki T, Mimura H, Gobara H et al (2009) CT fluoroscopy-guided biopsy of 1,000 pulmonary lesions performed with 20-gauge coaxial cutting needles: diagnostic yield and risk factors for diagnostic failure. Chest 136:1612–1617PubMedCrossRef
6.
Zurück zum Zitat Tam AL, Mohamed A, Pfister M et al (2010) C-arm cone beam computed tomography needle path overlay for fluoroscopic guided vertebroplasty. Spine 35:1095–1099PubMed Tam AL, Mohamed A, Pfister M et al (2010) C-arm cone beam computed tomography needle path overlay for fluoroscopic guided vertebroplasty. Spine 35:1095–1099PubMed
7.
Zurück zum Zitat Braak SJ, van Stijen MJL, van Es HW, Nievelstein RAJ, van Heesewijk JPM (2011) Effective dose during needle interventions: cone-beam CT guidance compared with conventional CT guidance. J Vasc Interv Radiol 22:455–461PubMedCrossRef Braak SJ, van Stijen MJL, van Es HW, Nievelstein RAJ, van Heesewijk JPM (2011) Effective dose during needle interventions: cone-beam CT guidance compared with conventional CT guidance. J Vasc Interv Radiol 22:455–461PubMedCrossRef
8.
Zurück zum Zitat Carrafiello G, Dizonno M, Colli V et al (2010) Comparative study of jaws with multislice computed tomography and cone-beam computed tomography. Radiol Med 115:600–611PubMedCrossRef Carrafiello G, Dizonno M, Colli V et al (2010) Comparative study of jaws with multislice computed tomography and cone-beam computed tomography. Radiol Med 115:600–611PubMedCrossRef
9.
Zurück zum Zitat Carrafiello G, Fontana F, Mangini M et al (2012) Initial experience with percutaneous biopsies of bone lesions using XperGuide cone-beam CT (CBCT): technical note. Radiol Med 117:1386–1397PubMedCrossRef Carrafiello G, Fontana F, Mangini M et al (2012) Initial experience with percutaneous biopsies of bone lesions using XperGuide cone-beam CT (CBCT): technical note. Radiol Med 117:1386–1397PubMedCrossRef
11.
Zurück zum Zitat Strocchi S, Colli V, Conte L et al (2012) Multidector CT fluoroscopy and cone-beam CT-guided percutaneous transthoracic biopsy: comparison based on patient doses. Radiat Prot Dosim 151:162–165CrossRef Strocchi S, Colli V, Conte L et al (2012) Multidector CT fluoroscopy and cone-beam CT-guided percutaneous transthoracic biopsy: comparison based on patient doses. Radiat Prot Dosim 151:162–165CrossRef
12.
Zurück zum Zitat Jin KN, Park CM, Goo JM et al (2010) Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT system. Eur Radiol 20:2108–2115PubMedCrossRef Jin KN, Park CM, Goo JM et al (2010) Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT system. Eur Radiol 20:2108–2115PubMedCrossRef
13.
Zurück zum Zitat Cheung JY, Kim Y, Shim SS et al (2011) Combined fluoroscopy- and CT-guided transthoracic needle biopsy using a C-arm cone-beam CT system: comparison with fluoroscopy-guided biopsy. Korean J Radiol 12:89–96PubMedPubMedCentralCrossRef Cheung JY, Kim Y, Shim SS et al (2011) Combined fluoroscopy- and CT-guided transthoracic needle biopsy using a C-arm cone-beam CT system: comparison with fluoroscopy-guided biopsy. Korean J Radiol 12:89–96PubMedPubMedCentralCrossRef
14.
Zurück zum Zitat Choi MJ, Kim Y, Hong YS et al (2012) Transthoracic needle biopsy using a C-arm cone-beam CT system: diagnostic accuracy and safety. Br J Radiol 85:182–187CrossRef Choi MJ, Kim Y, Hong YS et al (2012) Transthoracic needle biopsy using a C-arm cone-beam CT system: diagnostic accuracy and safety. Br J Radiol 85:182–187CrossRef
15.
Zurück zum Zitat Lee SM, Park CM, Lee KH et al (2014) C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of lung nodules: clinical experience in 1108 patients. Radiology 27:291–300CrossRef Lee SM, Park CM, Lee KH et al (2014) C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of lung nodules: clinical experience in 1108 patients. Radiology 27:291–300CrossRef
16.
Zurück zum Zitat Christner JA, Kofler JM, McCollough CH (2010) Estimating effective dose for CT using dose-length product compared with using organ doses: consequences of adopting International Commission on Radiological Protection publication 103 or dual–energy scanning. Am J Roentgenol 194:881–889CrossRef Christner JA, Kofler JM, McCollough CH (2010) Estimating effective dose for CT using dose-length product compared with using organ doses: consequences of adopting International Commission on Radiological Protection publication 103 or dual–energy scanning. Am J Roentgenol 194:881–889CrossRef
17.
Zurück zum Zitat D’Agostino RB, Belanger A, D’Agostino RB Jr (1990) A suggestion for using powerful and informative tests of normality. Am Stat 44:316–321 D’Agostino RB, Belanger A, D’Agostino RB Jr (1990) A suggestion for using powerful and informative tests of normality. Am Stat 44:316–321
18.
Zurück zum Zitat Li-Han H, Chia-Chuan L, Jen-Sheng K (2004) Education and experience improve the performance of transbronchial needle aspiration. A learning curve at a cancer center. Chest 125:532–540CrossRef Li-Han H, Chia-Chuan L, Jen-Sheng K (2004) Education and experience improve the performance of transbronchial needle aspiration. A learning curve at a cancer center. Chest 125:532–540CrossRef
19.
Zurück zum Zitat Hwang HS, Chung MJ, Lee JW et al (2010) C-arm cone-beam CT-guided percutaneous transthoracic lung biopsy: usefulness in evaluation of small pulmonary nodules. Am J Roentgenol 195:400–407CrossRef Hwang HS, Chung MJ, Lee JW et al (2010) C-arm cone-beam CT-guided percutaneous transthoracic lung biopsy: usefulness in evaluation of small pulmonary nodules. Am J Roentgenol 195:400–407CrossRef
20.
Zurück zum Zitat Gupta R, Cheung AC, Bartling SH et al (2008) Flat-panel volume CT: fundamental principles, technology, and applications. Radiographics 28:2009–2022PubMedCrossRef Gupta R, Cheung AC, Bartling SH et al (2008) Flat-panel volume CT: fundamental principles, technology, and applications. Radiographics 28:2009–2022PubMedCrossRef
21.
Zurück zum Zitat El-Sheik M, Heverhagen JT, Alfke H et al (2001) Multiplanar reconstructions and three-dimensional imaging (computed rotational osteography) of complex fractures by using a C-arm system: initial results. Radiology 221:843–849PubMedCrossRef El-Sheik M, Heverhagen JT, Alfke H et al (2001) Multiplanar reconstructions and three-dimensional imaging (computed rotational osteography) of complex fractures by using a C-arm system: initial results. Radiology 221:843–849PubMedCrossRef
22.
Zurück zum Zitat Kothary N, Lock L, Sze DY et al (2009) Computed tomography-guided percutaneous needle biopsy of pulmonary nodules: impact of nodule size on diagnostic accuracy. Clin Lung Cancer 10:360–363PubMedCrossRef Kothary N, Lock L, Sze DY et al (2009) Computed tomography-guided percutaneous needle biopsy of pulmonary nodules: impact of nodule size on diagnostic accuracy. Clin Lung Cancer 10:360–363PubMedCrossRef
23.
Zurück zum Zitat Braak SJ, Herder GJM, van Heesewijk JPM, van Strijen MJL (2012) Pulmonary masses: initial results of cone-beam CT guidance with needle planning software for percutaneous lung biopsy. Cardiovasc Intervent Radiol 35:1414–1421PubMedCrossRef Braak SJ, Herder GJM, van Heesewijk JPM, van Strijen MJL (2012) Pulmonary masses: initial results of cone-beam CT guidance with needle planning software for percutaneous lung biopsy. Cardiovasc Intervent Radiol 35:1414–1421PubMedCrossRef
24.
Zurück zum Zitat Khan MF, Straub R, Moghaddam SR et al (2008) Variables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided transthoracic biopsy. Eur Radiol 18:1356–1363PubMedCrossRef Khan MF, Straub R, Moghaddam SR et al (2008) Variables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided transthoracic biopsy. Eur Radiol 18:1356–1363PubMedCrossRef
25.
Zurück zum Zitat Covey AM, Gandhi R, Brody LA et al (2004) Factors associated with pneumothorax and pneumothorax requiring treatment after percutaneous lung biopsy in 443 consecutive patients. J Vasc Interv Radiol 15:479–483PubMedCrossRef Covey AM, Gandhi R, Brody LA et al (2004) Factors associated with pneumothorax and pneumothorax requiring treatment after percutaneous lung biopsy in 443 consecutive patients. J Vasc Interv Radiol 15:479–483PubMedCrossRef
26.
Zurück zum Zitat Yeow KM, Su IH, Pan KT et al (2004) Risk factors of pneumothorax and bleeding. Multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies. Chest 126:748–754PubMedCrossRef Yeow KM, Su IH, Pan KT et al (2004) Risk factors of pneumothorax and bleeding. Multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies. Chest 126:748–754PubMedCrossRef
27.
Zurück zum Zitat Saji H, Nakamura H, Tsuchida T et al (2002) The incidence and risk of pneumothorax and chest tube placement after percutaneous CT-guided lung biopsy. Chest 121:1521–1526PubMedCrossRef Saji H, Nakamura H, Tsuchida T et al (2002) The incidence and risk of pneumothorax and chest tube placement after percutaneous CT-guided lung biopsy. Chest 121:1521–1526PubMedCrossRef
28.
Zurück zum Zitat Choi JW, Park CM, Goo JM et al (2012) C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of small (≤20 mm) lung nodules: diagnostic accuracy and complications in 161 patients. Am J Roentgenol 199:322–330CrossRef Choi JW, Park CM, Goo JM et al (2012) C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of small (≤20 mm) lung nodules: diagnostic accuracy and complications in 161 patients. Am J Roentgenol 199:322–330CrossRef
29.
Zurück zum Zitat Kim JI, Park CM, Lee SM, Goo JM (2015) Rapid needle-out patient-rollover approach after cone beam CT-guided lung biopsy: effect on pneumothorax rate in 1,191 consecutive patients. Eur Radiol. doi:10.1007/s00330-015-3601-y Kim JI, Park CM, Lee SM, Goo JM (2015) Rapid needle-out patient-rollover approach after cone beam CT-guided lung biopsy: effect on pneumothorax rate in 1,191 consecutive patients. Eur Radiol. doi:10.​1007/​s00330-015-3601-y
30.
Zurück zum Zitat Choo JY, Park CM, Lee NK, Lee SM, Lee HJ, Goo JM (2013) Percutaneous transthoracic needle biopsy of small (≤1 cm) lung nodules under C-arm cone-beam CT virtual navigation guidance. Eur Radiol 23:712–719PubMedCrossRef Choo JY, Park CM, Lee NK, Lee SM, Lee HJ, Goo JM (2013) Percutaneous transthoracic needle biopsy of small (≤1 cm) lung nodules under C-arm cone-beam CT virtual navigation guidance. Eur Radiol 23:712–719PubMedCrossRef
31.
Zurück zum Zitat Kim GR, Hur J, Lee SM et al (2011) CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic performance. Eur Radiol 21:232–239PubMedCrossRef Kim GR, Hur J, Lee SM et al (2011) CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic performance. Eur Radiol 21:232–239PubMedCrossRef
Metadaten
Titel
Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules
verfasst von
Nicola Rotolo
Chiara Floridi
Andrea Imperatori
Federico Fontana
Anna Maria Ierardi
Monica Mangini
Veronica Arlant
Giuseppe De Marchi
Raffaele Novario
Lorenzo Dominioni
Carlo Fugazzola
Gianpaolo Carrafiello
Publikationsdatum
01.02.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 2/2016
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-015-3861-6

Weitere Artikel der Ausgabe 2/2016

European Radiology 2/2016 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.