Skip to main content
Erschienen in: European Radiology 7/2017

Open Access 12.12.2016 | Ultrasound

High-resolution ultrasound visualization of the recurrent motor branch of the median nerve: normal and first pathological findings

verfasst von: Georg Riegler, Christopher Pivec, Hannes Platzgummer, Doris Lieba-Samal, Peter Brugger, Suren Jengojan, Martin Vierhapper, Gerd Bodner

Erschienen in: European Radiology | Ausgabe 7/2017

Abstract

Purpose

To evaluate in a prospective study the possibility of visualization and diagnostic assessment of the recurrent motor branch (RMB) of the median nerve with high-resolution ultrasound (HRUS).

Materials and methods

HRUS with high-frequency probes (18–22 MhZ) was used to locate the RMB in eight fresh cadaveric hands. To verify correct identification, ink-marking and consecutive dissection were performed. Measurement of the RMB maximum transverse-diameter, an evaluation of the origin from the median nerve and its course in relation to the transverse carpal ligament, was performed in both hands of ten healthy volunteers (n = 20). Cases referred for HRUS examinations for suspected RMB lesions were also assessed.

Results

The RMB was clearly visible in all anatomical specimens and all volunteers. Dissection confirmed HRUS findings in all anatomical specimens. Mean RMB diameter in volunteers was 0.7 mm ± 0.1 (range, 0.6–1). The RMB originated from the radial aspect in 11 (55%), central aspect in eight (40%) and ulnar aspect in one (5%) hand. Nineteen (95%) extraligamentous courses and one (5%) subligamentous course were detected. Three patients with visible RMB abnormalities on HRUS were identified.

Conclusion

HRUS is able to reliably visualize the RMB, its variations and pathologies.

Key Points

Ultrasound allows visualization of the recurrent motor branch of the median nerve.
Ultrasound may help clinicians to assess patients with recurrent motor branch pathologies.
Patient management may become more appropriate and targeted therapy could be improved.

Introduction

The recurrent motor branch (RMB), sometimes also referred to as the muscular thenar branch of the median nerve, classically supplies innervation to the thenar musculature, including the abductor pollicis brevis, the opponens pollicis and the superficial head of the flexor pollicis brevis (Fig. 1) [1, 2]. These contribute to the most important movements of the hand: opposition and abduction of the thumb.
Damage to the RMB may lead to severely impaired function in patients, with loss of dexterity, pinch and grasp function. The main clinical relevance of the RMB is its susceptibility to iatrogenic injury, due to its variants, during decompression surgery for carpal tunnel syndrome (CTS) [3]. This is because anatomical studies have shown that there is high variability with regard to the origin from the median nerve [4, 5] and its course in relation to the transverse carpal ligament (TCL) [4, 69]. Moreover, accessory motor branches have also been described [2, 4, 1012].
Isolated RMB neuropathies are either rare or possibly underdiagnosed due to the lack of imaging modalities that can depict the nerve. Among these RMB neuropathies, anecdotal reports describe compression of the nerve due to schwannomas [1315], ganglia [16, 17], anomalous anatomical structures [18, 19], long distance cycling [20] or cutting injuries [21, 22]. Furthermore, there is an ongoing debate about whether selective involvement of the thenar motor fibres is a variant of CTS or an idiopathic entity [2326].
To date, evaluation and localization of the RMB has been restricted to electrophysiological assessment [26] and clinical testing using landmarks [27, 28].
High-resolution ultrasound (HRUS), using linear, high-frequency probes, offers excellent tissue differentiation for the examination of superficial structures and may facilitate imaging of the RMB. As this has been described for the palmar cutaneous branch of the median nerve [29], which can be assumed to have a comparable diameter, we hypothesized that RMB evaluation would be possible with HRUS. This may open the possibility of diagnosing pathologies related to the nerve, or allow for pre-surgical evaluation or marking in case of suspected variations, and, thus, reduce the risk of iatrogenic injuries.
Therefore, this study aimed to: (i) confirm the correct identification of the RMB by HRUS with ink-marking and consecutive dissection in anatomical specimens; (ii) provide the first measurements of RMB diameter, evaluating the origin, course and possible accessory branches in healthy volunteers; and (iii) present cases with RMB pathology found with HRUS.

Methods

Ultrasound technique

This prospective study was approved by the ethics committee of the Medical University of Vienna (EC-number 1529/2015) and was conducted between 1 February 2015 and 1 December 2015.
HRUS examinations were performed using a GE LOGIQ e (GE Healthcare, Wauwatosa, WI, USA) ultrasound (US) platform with high-frequency probes (GE L8-18i-D, GE L10-22-RS). Two radiologists carried out all examinations. One had more than 20 years’ experience (G.B.) and one had 4 years’ experience (G.R.) in peripheral nerve imaging. Both raters were present during the collection of the subjects. G.B. performed all the interventions on all the anatomical specimens. G.R. collected all the images of healthy individuals, with G.R. watching the procedure.
The examination followed a standardized assessment protocol that started with the transverse view of the median nerve or its digital cutaneous branches at the level of the metacarpal bodies III-IV. The probe was moved proximally until a tubular structure arising from the median nerve, in most cases curving radially and proximally and coursing toward the thenar musculature, was presumed to be the RMB. Subsequently, the origin was assessed by turning the probe until the longitudinal axis of the nerve was visible. In most cases, the RMB formed an approximately 45° angle with the median nerve. Subsequently, the nerve was followed until its entrance into the thenar musculature. To avoid confusion with the palmar cutaneous branch or the palmar digital branch of the median nerve, the RMB had to enter the thenar musculature in contrast to the other branches. To avoid confusion with vessels, colour Doppler was used. Probe positioning, probe track and measurement of the RMB diameter is presented in Fig. 2. The normal presentation of the RMB at its origin is presented in Fig. 3.
A second possibility to locate the RMB (considered by the authors to be more difficult) was to start with the transverse view of the median nerve 3 cm proximal to the pisiform bone. Following the median nerve, the probe was moved distally until its subdivision into terminal branches. At this level, the probe was moved proximally and distally to identify the RMB. After identification, the assessment of the nerve was performed in a manner similar to that described above.

Ultrasound in anatomical specimens

In four randomly selected fresh anatomical specimens in the legal custody of the Department of Systematic Anatomy, Medical University of Vienna, HRUS was performed as described above in both wrists (n = 8). After locating the RMB, a small amount of blue dye mixed with glue (0.1 ml) was injected into the nerve/adjacent to the nerve under HRUS guidance (22-gauge needle, in-plane technique). Subsequent anatomical dissection was performed to confirm the exact location of the dye injection. A plastic surgeon (M.V.) and anatomist (P.B.) who performed the dissections determined the exact location of the dye injection. Correct dye injection was noted if at least some amount of the dye was injected into the nerve sheath.

Ultrasound in healthy volunteers

Ten healthy volunteers were recruited via notices at the Department of Biomedical Imaging and Image-guided Therapy and word-of-mouth acquisition. Written informed consent was obtained from all volunteers. Inclusion criteria were age over 18 years, and exclusion criteria were known polyneuropathy, known myopathy, chronic disease known to cause peripheral neuropathy, current or previous CTS and previous hand surgery.
The RMB was assessed on both sides (n = 20). Measurements of the maximum transverse diameter were obtained immediately after the separation from the median nerve using the platform software of LOGIQ e. The origin of the RMB with respect to the median nerve was assessed according to Mackinnon and Dellon (4). The site of origin of the RMB from the median nerve was classified as either ulnar, central-volar or radial, since the intermediate type (one-third the distance between the radial and central aspect) described by Mackinnon and Dellon [5] is not clearly distinguishable with US.
The course of the RMB in relation to the transverse carpal ligament (TCL) was evaluated using the classification of Lanz [8]: extraligamentous – origin and course distal to the TCL; subligamentous – origin within the carpal tunnel, winding around the distal edge of the TCL; transligamentous – piercing the TCL. Furthermore, the presence of accessory branches was evaluated.

Ultrasound in patients

Between 1 February 2015 and 1 December 2015, we monitored patients who were referred to the Department of Biomedical Imaging and Image-guided Therapy, and in whom RMB pathologies were detected with HRUS. The referring diagnosis of all screened patients was clinically or electrophysiologically diagnosed carpal tunnel syndrome. All patients were referred to our department for preoperative evaluation prior to carpal tunnel surgery. HRUS examinations were performed using the same assessment protocol as described above.

Statistical analysis

Descriptive statistics were performed using IBM SPSS Statistics for Windows Version 22.0.0.2 (IBM, Armonk, NY, USA). Metric data (nerve diameter) are presented as mean ± standard deviation and range (minimum–maximum).

Results

Ultrasound in anatomical specimens

The RMB was clearly visible in all anatomical specimens. Dissection confirmed the correct identification of the RMB (100%) on both sites in all subjects (n = 8). An example of a dissection finding is shown in Fig. 3.

Ultrasound in healthy volunteers

Table 1 shows a summary of all demographic findings and measurements. Five females and five males (mean age, 31.5 years; age range, 27–54 years) were included in the study. The RMB could be visualized in both wrists of all volunteers (n = 20). Assessment of the nerve was possible from its origin until its ramification into terminal branches. Some of these branches could even be visualized in the thenar musculature. Sonographically, the RMB appeared as a hypoechoic, round dot in the transverse view, with a small surrounding hyperechoic border. While the hypoechoic dot was clearly depictable, the surrounding hyperechoic tissue, which we presumed to be the epineurium, was not well distinguishable from the adjacent tissue. Individual fascicles of the RMB could be seen in only a few cases.
Table 1
Demographic characteristics, measurement of transverse diameter, origin, course, and branches of the RMB in healthy
Volunteer No.
Sex
Age (y)
Side
TD (mm)
Origin
Branches
Course
1
M
31
R
0.06
Cen
1
Extra
1
M
31
L
0.07
Rad
1
Extra
2
M
33
R
0.06
Rad
1
Extra
2
M
33
L
0.06
Rad
1
Extra
3
M
55
L
0.07/0.06(a)
Rad
2
Extra
3
M
55
R
0.06
Rad
1
Extra
4
F
38
R
0.10
Rad
1
Extra
4
F
38
L
0.07
Uln
1
Sub
5
F
31
R
0.07
Cen
1
Extra
5
F
31
L
0.08
Cen
1
Extra
6
F
30
R
0.07
Rad
1
Extra
6
F
30
L
0.06
Cen
1
Extra
7
F
54
R
0.07
Cen
1
Extra
7
F
54
L
0.07
Cen
1
Extra
8
M
32
R
0.10
Rad
1
Extra
8
M
32
L
0.07
Rad
1
Extra
9
F
27
R
0.07
Rad
1
Extra
9
F
27
L
0.07
Cen
1
Extra
10
M
31
R
0.10
Rad
1
Extra
10
M
31
L
0.07
Cen
1
Extra
RMB recurrent motor branch, No. number, M male, F female, y years, R right, L Left, mm miliimeter, TD transverse diameter/mean cross sectional diameter, (a) accessory branch, Cen central, Rad radial, Uln ulnar, Extra extraligamentous, Sub subligamentous
The mean transverse diameter was 0.7 mm ± 0.1 (range, 0.6–1). The maximum detectable intraindividual side difference was 0.03 mm.
The RMB originated from the radial aspect in 11 hands (55%), the central aspect in eight hands (40%), and the ulnar aspect in one hand (5%).
An extraligamentous course was seen in 19 hands (95%), and a subligamentous course in one hand (5%). No transligamentous course was observed. One accessory branch arising from the radial aspect of the median nerve, with a maximum transverse diameter of 0.6 mm, was detected (Fig. 4 and Movie).

Ultrasound in patients

Of 189 patients with carpal tunnel syndrome, three patients (1.6%) with RMB pathologies were identified and are presented below. Figure 5 shows the HRUS findings of all patients.
Case 1
A 51-year-old female presented with a weakening of the thenar musculature for the 6 months prior to presentation, at the left wrist, sometimes combined with slight pain and paraesthesias in the first finger on her left side. Clinical examination revealed a loss of power (0/5) of thumb abduction, thenar wasting and a mild hypoesthesia of the first digit. Motor conduction studies showed severe axonal damage of motor fibres on the left (compound muscle action potential: left 1,500 μV, right 18,700 μV) and prolongation of distal motor latency, while sensory testing revealed a preserved sensory nerve action potential with a only slightly reduced amplitude of 12 μV and a decreased antidromic conduction velocity of 44 m/s. Sonographic assessment revealed a radially originating, extraligamentously coursing and severely thickened RMB (1.5 mm vs. 0.9 mm on the right). Further, the whole median nerve also exhibited an increased cross-sectional area of 0.23 cm2 within/distal to the carpal tunnel (upper limit normal ≤0.12 cm2). The clinically visible atrophy was also documented with US (Fig. 5). In accordance with the present findings, this was assumed to be CTS with severe involvement of the RMB.
Case 2
A 49-year-old female presented with paresis of the thenar muscles on her right side for the 4 months prior to presentation. No paraesthesias or pain were reported. Clinical examination revealed paresis of thumb opposition (2/5) and mild paresis of thumb abduction (4/5). Atrophy of the lateral thenar and the opponens pollicis muscle was visible. Sonographic assessment revealed a radially originating, extraligamentously coursing, moderately thickened RMB (1.3 mm) and a normal cross-sectional area of 0.10 cm2 (standard value ≤0.12 cm2) of the median nerve. Further, atrophy of the thenar musculature was assessed (Fig. 5). The patient was operated upon approximately 2 months after HRUS examination. There was a positive correlation between the sonographic findings and surgery. Intraoperatively, the RMB was thickened and seemed to be entrapped in ‘fibrous tissue’ directly after its origin from the median nerve, as classified by the surgeons. The fibrous tissue was removed and neurolysis was performed. A short-term follow-up 5 weeks after surgery revealed improved power (3/5) of thumb opposition and thumb abduction (5/5). In accordance with the present findings, this was assumed to be a variant of CTS with involvement of the RMB.
Case 3
A 45-year-old female presented with a severe paresis of the thenar musculature on her right side for the 6 months prior to presentation. No paraesthesias or pain were reported. Clinical examination revealed plegia of thumb abduction (0/5). A clear thenar atrophy was visible. Sonographic assessment revealed a radially originating, extraligamentously coursing and moderately thickened RMB (1.3 mm). Moreover, the radial-sided motor fascicles within the median nerve were clearly swollen. Further, atrophy of the thenar muscles was assessed (Figs. 5 and 6). In accordance with the present findings, this was assumed to be a variant of CTS with involvement of the RMB.

Discussion

This study confirms the reliable visualization of the RMB with HRUS using US-guided ink-marking and consecutive dissection in a series of anatomical specimens. Initial measurements of the RMB in healthy volunteers showed a mean transverse diameter of 0.7 mm ± 0.1 mm (range, 0.6–1). Subsequently, a broad variation in point of origin and course was observed.
Ultrasound measurements of the transverse diameter of the RMB in healthy volunteers revealed clearly lower values than previously described in anatomical studies. Wang and colleagues [30] reported a mean diameter of 1.7 ± 0.3 mm in seven fresh forearm amputation specimens, and Üstün et al. [31] reported a mean diameter of 1.4 mm ± 0.12 mm in ten fresh cadaver arms. This discrepancy in nerve diameter may be due to the different visualization methods employed. In our study, we could measure only the hypoechoic pattern of the nerve without the surrounding neural tissue. Measurements of the transverse diameter of the RMB with US have not yet been reported. As presented, the transverse diameter in patients clearly exceeded the upper limit observed in healthy volunteers. Therefore, HRUS may help to evaluate RMB pathologies, and our data may serve as a reference for further, more detailed US characterizations of the RMB.
In addition to the depiction of the RMB, HRUS provides further information about the course, origin and branching of this nerve. The course of the RMB in relation to the TCL has gained extensive attention in various studies, due to the fact that the ‘anomalous’ trans- and subligamentous variants, in particular, are at risk during both open and endoscopic surgery [3, 7, 8, 32]. Our results are comparable with previous studies [4, 69] (extraligamentous, 46–97%; subligamentous, 2–34%; transligamentous, 1–23%), although we did not detect a transligamentous course, which is mainly attributable to the small study sample.
The origin from the radial aspect of the median nerve was described as a possible site of entrapment because of separate obliquely arranged fibres from the TCL encircling the RMB [7]. As the radial origin is most common and the results of previous studies are in accordance with our data (55% vs. 60–80%) [4, 5], we think this condition can be easily detected by HRUS. The less frequent origin from the ulnar aspect of the median nerve (5% in our study vs. 1.1% in a study of 821 hands that had undergone carpal tunnel (CT) release surgery) [9] represents a major risk for iatrogenic injury with the ulnar side approach, as well as with the median approach, since the nerve crosses the anterior aspect of the median nerve during CT release [33].
Iatrogenic RMB injury during CT release seems to be a rare complication, with approximately 0.5% in the reported literature [3, 32]. Nevertheless, it represents a severe complication also called the ‘million dollar injury’ due to the compensation awarded in lawsuits because of the loss of thenar function [34, 35]. To date, no consensus exists about whether the branch should be examined intra- or preoperatively to avoid damage. Of 153 surgeons responding to a questionnaire, the majority (>70%) did not explore the nerve routinely and did not recommend doing so [36]. Other authors suggest exploring the RMB intraoperatively, at least for some special conditions [37]. Indeed, whenever the surgeon encounters muscle fibres lying superficial to or interposed within the TCL, there is a greater than 90% likelihood that the motor branch would be anomalous [37]. The preoperative RMB localization is limited to the use of surface landmarks, such as the Kaplan’s cardinal and middle finger radial-side-line, or a physical examination manoeuvre, such as the middle finger flexion test [27, 28]. Nevertheless, these tests are inaccurate when the RMB has a varying course. As an example, in middle finger flexion tests, the transligamentous course showed a deviation of 10–25 mm from where it was expected [27, 28]. RMB evaluation with HRUS overcomes all these limitations. It allows visualization of the nerve along its entire course, which may help surgeons to plan their approach for CT release. In the case of a ‘dangerous’ variation, preoperative skin-marking could be provided to facilitate exploration of the nerve. Although we did not observe an iatrogenic injury prior to re-operation during our short observation period, we saw one patient postoperatively who was treated for a complete transection of the RMB during carpal tunnel release. Therefore, the results of this study suggest that HRUS evaluation of the RMB should be included as part of the conventional sonographic examination for CTS to minimize iatrogenic injury during CT release.
In 1982, Bennet and Crouch [23] reported two cases of isolated compression of the RMB, characterized by selective involvement of thenar motor fibres. In these cases, the surgical observation showed compression of the branch due to a transligamentous course or an excessive angle of the thenar branch at the distal edge of the transverse ligament with neuroma formation proximal to the entrapment sites. Four subsequent electrophysiological and clinical studies underlined the theory that motor fascicles alone may be involved in CTS, or represent a separate entity without the classic CTS [2426, 38]. Our case 2 and case 3 may provide a hint that these conditions may be detectable by HRUS in the future. Nevertheless, further comparative HRUS studies between normal and pathological RMB conditions are needed to reliably answer this question.
This study has several strengths and limitations. Its strengths include the first-time use of HRUS for specific assessment of the RMB and confirmation of the findings by the gold standard of anatomical dissection. Its limitations include the fact that findings in vivo were uncontrolled. However, accuracy in anatomical specimens was 100% and RMB in volunteers could be followed into the abductor muscle. A further limitation is the fact that pathological findings in this manuscript are case reports and do not provide reliable information about the future role of HRUS in RMB pathology detection. For this reason, further comparative studies between normal and pathological conditions are needed.
In conclusion, this study confirms the reliable ability to visualize the RMB and its variations with HRUS, in anatomical specimens and in healthy volunteers. We therefore encourage the use of HRUS, especially for preoperative evaluation for carpal tunnel release or if thenar muscle weakening is present. Further studies are needed to assess the value of HRUS in diagnosing RMB pathologies.

Acknowledgements

Open access funding provided by Medical University of Vienna. The authors thank Mary McAllister for her comments on the manuscript. This work was orally presented at the ECR 2016 in Vienna. The scientific guarantor of this publication is Gerd Bodner. The authors of this manuscript declare no relationships with any companies whose products or services may be related to the subject matter of the article. The authors state that this work has not received any funding. No complex statistical methods were necessary for this paper. Institutional Review Board approval was obtained. Written informed consent was obtained from all subjects (patients) in this study. Methodology: prospective, experimental, performed at one institution.
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Radiologie

Kombi-Abonnement

Mit e.Med Radiologie erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes Radiologie, den Premium-Inhalten der radiologischen Fachzeitschriften, inklusive einer gedruckten Radiologie-Zeitschrift Ihrer Wahl.

Literatur
1.
Zurück zum Zitat Mazurek MT, Shin AY (2001) Upper extremity peripheral nerve anatomy: current concepts and applications. Clin Orthop Relat Res 7–20 Mazurek MT, Shin AY (2001) Upper extremity peripheral nerve anatomy: current concepts and applications. Clin Orthop Relat Res 7–20
2.
Zurück zum Zitat Mumford J, Morecraft R, Blair WF (1987) Anatomy of the thenar branch of the median nerve. J Hand Surg 12:361–365CrossRef Mumford J, Morecraft R, Blair WF (1987) Anatomy of the thenar branch of the median nerve. J Hand Surg 12:361–365CrossRef
3.
Zurück zum Zitat Benson LS, Bare AA, Nagle DJ et al (2006) Complications of endoscopic and open carpal tunnel release. Arthrosc: J Arthrosc Related Surg: Off Publ Arthrosc Assoc North Am Int Arthrosc Assoc 22:919–924, 924 e911–912CrossRef Benson LS, Bare AA, Nagle DJ et al (2006) Complications of endoscopic and open carpal tunnel release. Arthrosc: J Arthrosc Related Surg: Off Publ Arthrosc Assoc North Am Int Arthrosc Assoc 22:919–924, 924 e911–912CrossRef
4.
Zurück zum Zitat Hurwitz PJ (1996) Variations in the course of the thenar motor branch of the median nerve. J Hand Surg 21:344–346CrossRef Hurwitz PJ (1996) Variations in the course of the thenar motor branch of the median nerve. J Hand Surg 21:344–346CrossRef
5.
Zurück zum Zitat Mackinnon SE, Dellon AL (1988) Anatomic Investigations of Nerves at the Wrist.1. Orientation of the Motor Fascicle of the Median Nerve in the Carpal-Tunnel. Ann Plast Surg 21:32–35CrossRefPubMed Mackinnon SE, Dellon AL (1988) Anatomic Investigations of Nerves at the Wrist.1. Orientation of the Motor Fascicle of the Median Nerve in the Carpal-Tunnel. Ann Plast Surg 21:32–35CrossRefPubMed
6.
Zurück zum Zitat Al-Qattan MM (2010) Variations in the course of the thenar motor branch of the median nerve and their relationship to the hypertrophic muscle overlying the transverse carpal ligament. J Hand Surg 35:1820–1824CrossRef Al-Qattan MM (2010) Variations in the course of the thenar motor branch of the median nerve and their relationship to the hypertrophic muscle overlying the transverse carpal ligament. J Hand Surg 35:1820–1824CrossRef
7.
Zurück zum Zitat Kozin SH (1998) The anatomy of the recurrent branch of the median nerve. J Hand Surg 23:852–858CrossRef Kozin SH (1998) The anatomy of the recurrent branch of the median nerve. J Hand Surg 23:852–858CrossRef
8.
Zurück zum Zitat Lanz U (1977) Anatomical variations of the median nerve in the carpal tunnel. J Hand Surg 2:44–53CrossRef Lanz U (1977) Anatomical variations of the median nerve in the carpal tunnel. J Hand Surg 2:44–53CrossRef
9.
Zurück zum Zitat Tountas CP, Bihrle DM, MacDonald CJ et al (1987) Variations of the median nerve in the carpal canal. J Hand Surg 12:708–712CrossRef Tountas CP, Bihrle DM, MacDonald CJ et al (1987) Variations of the median nerve in the carpal canal. J Hand Surg 12:708–712CrossRef
10.
Zurück zum Zitat Alp M, Marur T, Akkin SM et al (2005) Ramification pattern of the thenar branch of the median nerve entering the thenar fascia and the distribution of the terminal branches in the thenar musculature: Anatomic cadaver study in 144 hands. Clin Anat 18:195–199CrossRefPubMed Alp M, Marur T, Akkin SM et al (2005) Ramification pattern of the thenar branch of the median nerve entering the thenar fascia and the distribution of the terminal branches in the thenar musculature: Anatomic cadaver study in 144 hands. Clin Anat 18:195–199CrossRefPubMed
11.
Zurück zum Zitat Olave E, Prates JC, Gabrielli C et al (1996) Morphometric studies of the muscular branch of the median nerve. J Anat 189(Pt 2):445–449PubMedPubMedCentral Olave E, Prates JC, Gabrielli C et al (1996) Morphometric studies of the muscular branch of the median nerve. J Anat 189(Pt 2):445–449PubMedPubMedCentral
12.
Zurück zum Zitat Sacks JM, Kuo YR, McLean K et al (2007) Anatomical relationships among the median nerve thenar branch, superficial palmar arch, and transverse carpal ligament. Plast Reconstr Surg 120:713–718CrossRefPubMed Sacks JM, Kuo YR, McLean K et al (2007) Anatomical relationships among the median nerve thenar branch, superficial palmar arch, and transverse carpal ligament. Plast Reconstr Surg 120:713–718CrossRefPubMed
13.
Zurück zum Zitat Fiaschi P, Pacetti M, Secci F et al (2015) A rare case of first motor branch of median nerve schwannoma. Neur Sci: Off J Italian Neurol Soc Italian Soc Clin Neurophysiol 36:659–661CrossRef Fiaschi P, Pacetti M, Secci F et al (2015) A rare case of first motor branch of median nerve schwannoma. Neur Sci: Off J Italian Neurol Soc Italian Soc Clin Neurophysiol 36:659–661CrossRef
14.
Zurück zum Zitat Josty IC, Sykes PJ (2001) An unusual schwannoma of the median nerve: effects on the motor branch. Br J Plast Surg 54:71–73CrossRefPubMed Josty IC, Sykes PJ (2001) An unusual schwannoma of the median nerve: effects on the motor branch. Br J Plast Surg 54:71–73CrossRefPubMed
15.
Zurück zum Zitat Squarzina PB, Adani R, Cerofolini E et al (1993) Ancient schwannoma of the motor branch of the median nerve: a clinical case. La Chirurgia Degli Organi Di Movimento 78:19–23PubMed Squarzina PB, Adani R, Cerofolini E et al (1993) Ancient schwannoma of the motor branch of the median nerve: a clinical case. La Chirurgia Degli Organi Di Movimento 78:19–23PubMed
16.
Zurück zum Zitat Jensen TT (1990) Isolated compression of the motor branch of the median nerve by a ganglion. Case report. Scan J Plastic Reconstruc Surg Hand Surg/Nordisk Plastikkirurgisk Forening [and] Nordisk Klubb Handkirurgi 24:171CrossRef Jensen TT (1990) Isolated compression of the motor branch of the median nerve by a ganglion. Case report. Scan J Plastic Reconstruc Surg Hand Surg/Nordisk Plastikkirurgisk Forening [and] Nordisk Klubb Handkirurgi 24:171CrossRef
17.
Zurück zum Zitat Kato H, Ogino T, Nanbu T et al (1991) Compression neuropathy of the motor branch of the median nerve caused by palmar ganglion. J Hand Surg 16:751–752CrossRef Kato H, Ogino T, Nanbu T et al (1991) Compression neuropathy of the motor branch of the median nerve caused by palmar ganglion. J Hand Surg 16:751–752CrossRef
18.
Zurück zum Zitat Widder S, Shons AR (1988) Carpal tunnel syndrome associated with extra tunnel vascular compression of the median nerve motor branch. J Hand Surg 13:926–927CrossRef Widder S, Shons AR (1988) Carpal tunnel syndrome associated with extra tunnel vascular compression of the median nerve motor branch. J Hand Surg 13:926–927CrossRef
19.
Zurück zum Zitat Yamanaka K, Horiuchi Y, Yabe Y (1994) Compression neuropathy of the motor branch of the median nerve due to an anomalous thenar muscle. J Hand Surg 19:711–712CrossRef Yamanaka K, Horiuchi Y, Yabe Y (1994) Compression neuropathy of the motor branch of the median nerve due to an anomalous thenar muscle. J Hand Surg 19:711–712CrossRef
20.
Zurück zum Zitat Ali E, Delamont RS, Jenkins D et al (2013) Bilateral recurrent motor branch of median nerve neuropathy following long-distance cycling. Clin Neurophysiol: Of J Int Fed Clin Neurophysiol 124:1258–1260CrossRef Ali E, Delamont RS, Jenkins D et al (2013) Bilateral recurrent motor branch of median nerve neuropathy following long-distance cycling. Clin Neurophysiol: Of J Int Fed Clin Neurophysiol 124:1258–1260CrossRef
21.
Zurück zum Zitat Haussmann P (1980) Isolated traumatic lesions of the motor nerve branches in the hand. Handchirurgie 12:23–25PubMed Haussmann P (1980) Isolated traumatic lesions of the motor nerve branches in the hand. Handchirurgie 12:23–25PubMed
22.
Zurück zum Zitat Nara Y, Hasegawa O, Matsumoto M et al (1995) Electrophysiologic evaluation of entrapment neuropathy caused by scar formation in recurrent motor branch of the median nerve. No to Shinkei Brain Nerve 47:779PubMed Nara Y, Hasegawa O, Matsumoto M et al (1995) Electrophysiologic evaluation of entrapment neuropathy caused by scar formation in recurrent motor branch of the median nerve. No to Shinkei Brain Nerve 47:779PubMed
23.
Zurück zum Zitat Bennett JB, Crouch CC (1982) Compression syndrome of the recurrent motor branch of the median nerve. J Hand Surg 7:407–409CrossRef Bennett JB, Crouch CC (1982) Compression syndrome of the recurrent motor branch of the median nerve. J Hand Surg 7:407–409CrossRef
24.
Zurück zum Zitat Cosgrove JL, Chase PM, Mast NJ (2002) Thenar motor syndrome: median mononeuropathy of the hand. Am J Phys Med Rehab/Assoc Acad Phys 81:421–423CrossRef Cosgrove JL, Chase PM, Mast NJ (2002) Thenar motor syndrome: median mononeuropathy of the hand. Am J Phys Med Rehab/Assoc Acad Phys 81:421–423CrossRef
25.
Zurück zum Zitat Mondelli M, Aretini A, Ginanneschi F et al (2010) Thenar motor neuropathy electrophysiological study of 28 cases. J Clin Neurophysiol: Off Publ Am Electroencephalographic Soc 27:344–349CrossRef Mondelli M, Aretini A, Ginanneschi F et al (2010) Thenar motor neuropathy electrophysiological study of 28 cases. J Clin Neurophysiol: Off Publ Am Electroencephalographic Soc 27:344–349CrossRef
26.
Zurück zum Zitat Repaci M, Torrieri F, Di Blasio F et al (1999) Exclusive electrophysiological motor involvement in carpal tunnel syndrome. Clin Neurophysiol: Off J Int Fed Clin Neurophysiol 110:1471–1474CrossRef Repaci M, Torrieri F, Di Blasio F et al (1999) Exclusive electrophysiological motor involvement in carpal tunnel syndrome. Clin Neurophysiol: Off J Int Fed Clin Neurophysiol 110:1471–1474CrossRef
27.
Zurück zum Zitat Eskandari MM, Yilmaz C, Oztuna V et al (2005) Topographic localization of the motor branch of the median nerve. J Hand Surg 30:803–807CrossRef Eskandari MM, Yilmaz C, Oztuna V et al (2005) Topographic localization of the motor branch of the median nerve. J Hand Surg 30:803–807CrossRef
28.
Zurück zum Zitat Rodriguez R, Strauch RJ (2013) The middle finger flexion test to locate the thenar motor branch of the median nerve. J Hand Surg 38:1547–1550CrossRef Rodriguez R, Strauch RJ (2013) The middle finger flexion test to locate the thenar motor branch of the median nerve. J Hand Surg 38:1547–1550CrossRef
29.
Zurück zum Zitat Tagliafico A, Pugliese F, Bianchi S et al (2008) High-resolution sonography of the palmar cutaneous branch of the median nerve. AJR Am J Roentgenol 191:107–114CrossRefPubMed Tagliafico A, Pugliese F, Bianchi S et al (2008) High-resolution sonography of the palmar cutaneous branch of the median nerve. AJR Am J Roentgenol 191:107–114CrossRefPubMed
30.
Zurück zum Zitat Wang Y, Zhu S (1997) Transfer of a branch of the anterior interosseus nerve to the motor branch of the median nerve and ulnar nerve. Chin Med J 110:216–219PubMed Wang Y, Zhu S (1997) Transfer of a branch of the anterior interosseus nerve to the motor branch of the median nerve and ulnar nerve. Chin Med J 110:216–219PubMed
31.
Zurück zum Zitat Ustun ME, Ogun TC, Karabulut AK et al (2001) An alternative method for restoring opposition after median nerve injury: an anatomical feasibility study for the use of neurotisation. J Anat 198:635–638CrossRefPubMedPubMedCentral Ustun ME, Ogun TC, Karabulut AK et al (2001) An alternative method for restoring opposition after median nerve injury: an anatomical feasibility study for the use of neurotisation. J Anat 198:635–638CrossRefPubMedPubMedCentral
32.
Zurück zum Zitat Palmer AK, Toivonen DA (1999) Complications of endoscopic and open carpal tunnel release. J Hand Surg 24:561–565CrossRef Palmer AK, Toivonen DA (1999) Complications of endoscopic and open carpal tunnel release. J Hand Surg 24:561–565CrossRef
33.
Zurück zum Zitat Lilly CJ, Magnell TD (1985) Severance of the thenar branch of the median nerve as a complication of carpal tunnel release. J Hand Surg 10:399–402CrossRef Lilly CJ, Magnell TD (1985) Severance of the thenar branch of the median nerve as a complication of carpal tunnel release. J Hand Surg 10:399–402CrossRef
34.
Zurück zum Zitat Krishnan P, Mishra R, Jena M et al (2013) Transligamentous thenar branch of the median nerve: the million dollar nerve. Neurol India 61:311–312CrossRefPubMed Krishnan P, Mishra R, Jena M et al (2013) Transligamentous thenar branch of the median nerve: the million dollar nerve. Neurol India 61:311–312CrossRefPubMed
35.
Zurück zum Zitat Virgilio C (2014) Surgery. Springer Science + Business Media, New York Virgilio C (2014) Surgery. Springer Science + Business Media, New York
36.
Zurück zum Zitat Candal-Couto JJ, Sher JL (2007) The thenar motor branch during carpal tunnel decompression: "the expert opinion". Arch Orthop Trauma Surg 127:431–434CrossRefPubMed Candal-Couto JJ, Sher JL (2007) The thenar motor branch during carpal tunnel decompression: "the expert opinion". Arch Orthop Trauma Surg 127:431–434CrossRefPubMed
37.
Zurück zum Zitat Green DP, Morgan JP (2008) Correlation between muscle morphology of the transverse carpal ligament and branching pattern of the motor branch of median nerve. J Hand Surg 33:1505–1511CrossRef Green DP, Morgan JP (2008) Correlation between muscle morphology of the transverse carpal ligament and branching pattern of the motor branch of median nerve. J Hand Surg 33:1505–1511CrossRef
38.
Zurück zum Zitat Mondelli M, Baldasseroni A, Aretini A et al (2010) Prevalent involvement of thenar motor fibres in vineyard workers with carpal tunnel syndrome. Clin Neurophysiol:Off J Int Fed Clin Neurophysiol 121:1251–1255CrossRef Mondelli M, Baldasseroni A, Aretini A et al (2010) Prevalent involvement of thenar motor fibres in vineyard workers with carpal tunnel syndrome. Clin Neurophysiol:Off J Int Fed Clin Neurophysiol 121:1251–1255CrossRef
Metadaten
Titel
High-resolution ultrasound visualization of the recurrent motor branch of the median nerve: normal and first pathological findings
verfasst von
Georg Riegler
Christopher Pivec
Hannes Platzgummer
Doris Lieba-Samal
Peter Brugger
Suren Jengojan
Martin Vierhapper
Gerd Bodner
Publikationsdatum
12.12.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 7/2017
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-016-4671-1

Weitere Artikel der Ausgabe 7/2017

European Radiology 7/2017 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.