Data assessing the effectiveness of single-use flexible ureteropyeloscopy (FURS) are limited. This study evaluates and compares single-use FURS with conventional reusable FURS.

Methods

A systematic search using electronic databases (Pubmed and Embase) was performed for studies evaluating single-use FURS in the setting of urinary tract stone disease. Outcome measures included a comparative evaluation of their mechanical, optical and clinical outcomes.

Results

Eleven studies on 466 patients met inclusion criteria. In vitro comparative data were available on three single-use flexible ureteropyeloscopes (LithoVue™, Polyscope™ and SemiFlex™) and clinical data were available on two (LithoVue™ and Polyscope™). The overall stone-free rate and complication rate associated with single-use FURS was 87 ± 15% and 9.3 ± 9%, respectively. There were no significant differences in procedure duration, stone size, stone clearance and complication rates when single-use FURS and reusable FURS were compared (duration: 73 ± 27 versus 74 ± 13 min, p = 0.99; stone size: 1.36 ± 0.2 versus 1.34 ± 0.18 cm, p = 0.93; stone-free rate: 77.8 ± 18 versus 68.5 ± 33%, p = 0.76; complication rate 15.3 ± 10.6 versus 15 ± 1.6%, p = 0.3).

Conclusions

Single-use FURS demonstrates comparable efficacy with reusable FURS in treating renal calculi. Further studies on clinical efficacy and cost are needed to determine whether single-use FURS will reliably replace its reusable counterpart.
Literatur
2.
Zurück zum Zitat Bagley DH (1987) Flexible ureteropyeloscopy with modular, “disposable” endoscope. Urology 29(3):296–300CrossRefPubMed Bagley DH (1987) Flexible ureteropyeloscopy with modular, “disposable” endoscope. Urology 29(3):296–300CrossRefPubMed
3.
Zurück zum Zitat Emiliani E, Traxer O (2017) Single use and disposable flexible ureteroscopes. Curr Opin Urol 27(2):176–181CrossRefPubMed Emiliani E, Traxer O (2017) Single use and disposable flexible ureteroscopes. Curr Opin Urol 27(2):176–181CrossRefPubMed
4.
Zurück zum Zitat Doizi S, Traxer O (2017) Re: Evaluation of a novel single-use flexible ureteroscope. Eur Urol 72(1):152–153CrossRefPubMed Doizi S, Traxer O (2017) Re: Evaluation of a novel single-use flexible ureteroscope. Eur Urol 72(1):152–153CrossRefPubMed
5.
Zurück zum Zitat Boylu U, Oommen M, Thomas R, Lee BR (2009) In vitro comparison of a disposable flexible ureteroscope and conventional flexible ureteroscopes. J Urol 182(5):2347–2351CrossRefPubMed Boylu U, Oommen M, Thomas R, Lee BR (2009) In vitro comparison of a disposable flexible ureteroscope and conventional flexible ureteroscopes. J Urol 182(5):2347–2351CrossRefPubMed
7.
Zurück zum Zitat Ding J, Xu D, Cao Q, Huang T, Zhu Y, Huang K et al (2015) Comparing the efficacy of a multimodular flexible ureteroscope with its conventional counterpart in the management of renal stones. Urology 86(2):224–229CrossRefPubMed Ding J, Xu D, Cao Q, Huang T, Zhu Y, Huang K et al (2015) Comparing the efficacy of a multimodular flexible ureteroscope with its conventional counterpart in the management of renal stones. Urology 86(2):224–229CrossRefPubMed
8.
Zurück zum Zitat Huang Y-T (2013) Clinical effectiveness of the PolyScopeTM endoscope system combined with holmium laser lithotripsy in the treatment of upper urinary calculi with a diameter of less than 2 cm. Exp Ther Med 6(2):591–595CrossRefPubMedPubMedCentral Huang Y-T (2013) Clinical effectiveness of the PolyScopeTM endoscope system combined with holmium laser lithotripsy in the treatment of upper urinary calculi with a diameter of less than 2 cm. Exp Ther Med 6(2):591–595CrossRefPubMedPubMedCentral
9.
Zurück zum Zitat Bansal H, Swain S, Sharma GK, Mathanya M, Trivedi S, Dwivedi US et al (2011) Polyscope: a new era in flexible ureterorenoscopy. J Endourol 25(2):317–321CrossRefPubMed Bansal H, Swain S, Sharma GK, Mathanya M, Trivedi S, Dwivedi US et al (2011) Polyscope: a new era in flexible ureterorenoscopy. J Endourol 25(2):317–321CrossRefPubMed
10.
Zurück zum Zitat Bader MJ, Gratzke C, Walther S, Schlenker B, Tilki D, Hocaoglu Y et al (2010) The PolyScope: a modular design, semidisposable flexible ureterorenoscope system. J Endourol 24(7):1061–1066CrossRefPubMed Bader MJ, Gratzke C, Walther S, Schlenker B, Tilki D, Hocaoglu Y et al (2010) The PolyScope: a modular design, semidisposable flexible ureterorenoscope system. J Endourol 24(7):1061–1066CrossRefPubMed
11.
Zurück zum Zitat Usawachintachit M, Isaacson DS, Taguchi K, Tzou DT, Hsi RS, Sherer BA et al (2017) A prospective case–control study comparing LithoVue, a single-use, flexible disposable ureteroscope, with flexible, reusable fiber-optic ureteroscopes. J Endourol 31(5):468–475CrossRefPubMed Usawachintachit M, Isaacson DS, Taguchi K, Tzou DT, Hsi RS, Sherer BA et al (2017) A prospective case–control study comparing LithoVue, a single-use, flexible disposable ureteroscope, with flexible, reusable fiber-optic ureteroscopes. J Endourol 31(5):468–475CrossRefPubMed
12.
Zurück zum Zitat Doizi S, Kamphuis G, Giusti G, Andreassen KH, Knoll T, Osther PJ et al (2017) First clinical evaluation of a new single-use flexible ureteroscope (LithoVueTM): a European prospective multicentric feasibility study. World J Urol 35(5):809–818CrossRefPubMed Doizi S, Kamphuis G, Giusti G, Andreassen KH, Knoll T, Osther PJ et al (2017) First clinical evaluation of a new single-use flexible ureteroscope (LithoVueTM): a European prospective multicentric feasibility study. World J Urol 35(5):809–818CrossRefPubMed
13.
Zurück zum Zitat Proietti S, Dragos L, Molina W, Doizi S, Giusti G, Traxer O (2016) Comparison of new single-use digital flexible ureteroscope versus nondisposable fiber optic and digital ureteroscope in a cadaveric model. J Endourol 30(6):655–659CrossRefPubMedPubMedCentral Proietti S, Dragos L, Molina W, Doizi S, Giusti G, Traxer O (2016) Comparison of new single-use digital flexible ureteroscope versus nondisposable fiber optic and digital ureteroscope in a cadaveric model. J Endourol 30(6):655–659CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat Wiseman O, Keeley F, Traxer O, Giusti G, Lipkin M, Preminger G (2016) Comparison of a new single-use digital flexible ureteroscope (LithoVue) to a non-disposable fibre-optic flexible ureteroscope in a live porcine model. J Urol 195(4):e682CrossRef Wiseman O, Keeley F, Traxer O, Giusti G, Lipkin M, Preminger G (2016) Comparison of a new single-use digital flexible ureteroscope (LithoVue) to a non-disposable fibre-optic flexible ureteroscope in a live porcine model. J Urol 195(4):e682CrossRef
16.
Zurück zum Zitat Johnson MT, Khemees T a, Knudsen BE. Resilience of disposable endoscope optical fiber properties after repeat sterilization. J Endourol. 2013;27(1):71–4 Johnson MT, Khemees T a, Knudsen BE. Resilience of disposable endoscope optical fiber properties after repeat sterilization. J Endourol. 2013;27(1):71–4
17.
Zurück zum Zitat Ghodoussipour S, Thompson E, Shah A, Mitra A, Deshmukh S, Dunn M (2017) Mp50-08 Limitations of the lithovue single use digital flexible ureteroscope. J Urol 197(4):e686–e687CrossRef Ghodoussipour S, Thompson E, Shah A, Mitra A, Deshmukh S, Dunn M (2017) Mp50-08 Limitations of the lithovue single use digital flexible ureteroscope. J Urol 197(4):e686–e687CrossRef
18.
Zurück zum Zitat Doersch K, Elmekresh A, Milburn PA, Machen G, Hart K, El Tayeb M (2017) Pd35-08 Utilization of pressurized vs non-pressurized irrigation during ureteroscopy in the absence of ureteral access sheath: comparative retrospective study. J Urol 197(4):e665–e666CrossRef Doersch K, Elmekresh A, Milburn PA, Machen G, Hart K, El Tayeb M (2017) Pd35-08 Utilization of pressurized vs non-pressurized irrigation during ureteroscopy in the absence of ureteral access sheath: comparative retrospective study. J Urol 197(4):e665–e666CrossRef
19.
Zurück zum Zitat Buttice S, Sener TE, Netsch C, Emiliani E, Pappalardo R, Magno C (2016) LithoVueTM: a new single-use digital flexible ureteroscope. Cent Eur J Urol 69(3):302–305 Buttice S, Sener TE, Netsch C, Emiliani E, Pappalardo R, Magno C (2016) LithoVueTM: a new single-use digital flexible ureteroscope. Cent Eur J Urol 69(3):302–305
20.
Zurück zum Zitat Siu JJ-Y, Chen H-Y, Liao P-C, Chiang J-H, Chang C-H, Chen Y-H et al (2016) The cost-effectiveness of treatment modalities for ureteral stones. Inq J Heal Care Organ Provis Financ 53(91):4695801666901CrossRef Siu JJ-Y, Chen H-Y, Liao P-C, Chiang J-H, Chang C-H, Chen Y-H et al (2016) The cost-effectiveness of treatment modalities for ureteral stones. Inq J Heal Care Organ Provis Financ 53(91):4695801666901CrossRef
21.
Zurück zum Zitat Pietrow PK, Auge BK, Delvecchio FC, Silverstein AD, Weizer AZ, Albala DM et al (2002) Techniques to maximize flexible ureteroscope longevity. Urology 60(5):784–788CrossRefPubMed Pietrow PK, Auge BK, Delvecchio FC, Silverstein AD, Weizer AZ, Albala DM et al (2002) Techniques to maximize flexible ureteroscope longevity. Urology 60(5):784–788CrossRefPubMed
22.
Zurück zum Zitat Carey RI, Gomez CS, Maurici G, Lynne CM, Leveillee RJ, Bird VG (2006) Frequency of ureteroscope damage seen at a tertiary care center. J Urol 176(2):607–610CrossRefPubMed Carey RI, Gomez CS, Maurici G, Lynne CM, Leveillee RJ, Bird VG (2006) Frequency of ureteroscope damage seen at a tertiary care center. J Urol 176(2):607–610CrossRefPubMed
23.
Zurück zum Zitat Defidio L, De Dominicis M, Di Gianfrancesco L, Fuchs G, Patel A (2012) Improving flexible ureterorenoscope durability up to 100 procedures. J Endourol 26(10):1329–1334CrossRefPubMed Defidio L, De Dominicis M, Di Gianfrancesco L, Fuchs G, Patel A (2012) Improving flexible ureterorenoscope durability up to 100 procedures. J Endourol 26(10):1329–1334CrossRefPubMed
24.
Zurück zum Zitat Sung JC, Springhart WP, Marguet CG, L’Esperance JO, Tan YH, Albala DM et al (2005) Location and etiology of flexible and semirigid ureteroscope damage. Urology 66(5):958–963CrossRefPubMed Sung JC, Springhart WP, Marguet CG, L’Esperance JO, Tan YH, Albala DM et al (2005) Location and etiology of flexible and semirigid ureteroscope damage. Urology 66(5):958–963CrossRefPubMed
25.
Zurück zum Zitat Semins MJ, George S, Allaf ME, Matlaga BR (2009) Ureteroscope cleaning and sterilization by the urology operating room team: the effect on repair costs. J Endourol 23(6):903–905CrossRefPubMed Semins MJ, George S, Allaf ME, Matlaga BR (2009) Ureteroscope cleaning and sterilization by the urology operating room team: the effect on repair costs. J Endourol 23(6):903–905CrossRefPubMed
26.
Zurück zum Zitat Muggeo E, Boissel A, Martin L, Sgro C, Michiels C (2015) Cost comparison of two reprocessing procedures of flexible ureteroscopes at the University Hospital of Dijon. Prog Urol 25(6):318–324CrossRefPubMed Muggeo E, Boissel A, Martin L, Sgro C, Michiels C (2015) Cost comparison of two reprocessing procedures of flexible ureteroscopes at the University Hospital of Dijon. Prog Urol 25(6):318–324CrossRefPubMed
27.
Zurück zum Zitat Landman J, Lee DI, Lee C, Monga M (2003) Evaluation of overall costs of currently available small flexible ureteroscopes. Urology 62(2):218–222CrossRefPubMed Landman J, Lee DI, Lee C, Monga M (2003) Evaluation of overall costs of currently available small flexible ureteroscopes. Urology 62(2):218–222CrossRefPubMed
28.
Zurück zum Zitat Kramolowsky E, McDowell Z, Moore B, Booth B, Wood N (2016) Cost analysis of flexible ureteroscope repairs: evaluation of 655 procedures in a community-based practice. J Endourol 30(3):254–256CrossRefPubMed Kramolowsky E, McDowell Z, Moore B, Booth B, Wood N (2016) Cost analysis of flexible ureteroscope repairs: evaluation of 655 procedures in a community-based practice. J Endourol 30(3):254–256CrossRefPubMed
29.
Zurück zum Zitat Ozimek T, Schneider MH, Hupe MC, Wiessmeyer JR, Cordes J, Chlosta PL, Merseburger AS, Kramer MW (2017) Retrospective cost analysis of a single-center reusable flexible ureterorenoscopy (fURS) program: a comparative cost simulation of disposable fURS as an alternative. J Endourol. https://doi.org/10.1089/end.2017.0427 (epub ahead of print) PubMed Ozimek T, Schneider MH, Hupe MC, Wiessmeyer JR, Cordes J, Chlosta PL, Merseburger AS, Kramer MW (2017) Retrospective cost analysis of a single-center reusable flexible ureterorenoscopy (fURS) program: a comparative cost simulation of disposable fURS as an alternative. J Endourol. https://​doi.​org/​10.​1089/​end.​2017.​0427 (epub ahead of print) PubMed
30.
Zurück zum Zitat Martin CJ, McAdams SB, Abdul-Muhsin H, Lim VM, Nunez-Nateras R, Tyson MD et al (2017) The economic implications of a reusable flexible digital ureteroscope: a cost-benefit analysis. J Urol 197(3):730–735CrossRefPubMed Martin CJ, McAdams SB, Abdul-Muhsin H, Lim VM, Nunez-Nateras R, Tyson MD et al (2017) The economic implications of a reusable flexible digital ureteroscope: a cost-benefit analysis. J Urol 197(3):730–735CrossRefPubMed
31.
Zurück zum Zitat Grasso M, Bagley D (1998) Small diameter, actively deflectable, flexible ureteropyeloscopy. J Urol 160(5):1648–1654CrossRefPubMed Grasso M, Bagley D (1998) Small diameter, actively deflectable, flexible ureteropyeloscopy. J Urol 160(5):1648–1654CrossRefPubMed
32.
Zurück zum Zitat Fojecki G, Hennessey D, Lawrentschuk N, Bolton D (2017) Comparison of parameters of standard reusable flexible uretero-renoscopes with a single use uretero-renoscope (LithoVueTM). J Urol 197(4):e686CrossRef Fojecki G, Hennessey D, Lawrentschuk N, Bolton D (2017) Comparison of parameters of standard reusable flexible uretero-renoscopes with a single use uretero-renoscope (LithoVueTM). J Urol 197(4):e686CrossRef
Metadaten
Titel
Single-use flexible ureteropyeloscopy: a systematic review
Publikationsdatum
24.11.2017
Erschienen in
World Journal of Urology / Ausgabe 4/2018
Print ISSN: 0724-4983
Elektronische ISSN: 1433-8726
DOI
https://doi.org/10.1007/s00345-017-2131-4

Weitere Artikel der Ausgabe 4/2018

World Journal of Urology 4/2018 Zur Ausgabe

Update Urologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.