Erschienen in: Clinical Research in Cardiology 11/2010

01.11.2010 | Letter to the Editors

Inappropriate shock delivery by implantable cardioverter defibrillator due to electrical leak from bathroom tap

verfasst von: Ahmet Çamsarı, Dilek Çiçek Yılmaz, Türkay Özcan

Erschienen in: Clinical Research in Cardiology | Ausgabe 11/2010

Einloggen, um Zugang zu erhalten

Excerpt

Sirs: …
Literatur
1.
Zurück zum Zitat Mathew P, Lewis C, Neglia J et al (1997) Interaction between electronic article surveillance systems and implantable defibrillators: insights from a fourth generation ICD. Pacing Clin Electrophysiol 20:2857e9CrossRef Mathew P, Lewis C, Neglia J et al (1997) Interaction between electronic article surveillance systems and implantable defibrillators: insights from a fourth generation ICD. Pacing Clin Electrophysiol 20:2857e9CrossRef
2.
Zurück zum Zitat Madrid A, Sanchez A, Bosch E et al (1997) Dysfunction of implantable defibrillators caused by slot machines. Pacing Clin Electrophysiol 20:212e4CrossRef Madrid A, Sanchez A, Bosch E et al (1997) Dysfunction of implantable defibrillators caused by slot machines. Pacing Clin Electrophysiol 20:212e4CrossRef
3.
Zurück zum Zitat Seifert T, Block M, Borggrefe M et al (1995) Erroneous discharge of an implantable cardioverter defibrillator caused by an electric razor. Pacing Clin Electrophysiol 18:1592e4CrossRef Seifert T, Block M, Borggrefe M et al (1995) Erroneous discharge of an implantable cardioverter defibrillator caused by an electric razor. Pacing Clin Electrophysiol 18:1592e4CrossRef
4.
Zurück zum Zitat Man KC, Davidson T, Langberg JJ et al (1993) Interference from a hand held radiofrequency remote control causing discharge of an implantable defibrillator. Pacing Clin Electrophysiol 16:1756e8CrossRef Man KC, Davidson T, Langberg JJ et al (1993) Interference from a hand held radiofrequency remote control causing discharge of an implantable defibrillator. Pacing Clin Electrophysiol 16:1756e8CrossRef
5.
Zurück zum Zitat Wayar L, Mont L, Silva RMFL et al (2003) Electrical interference from an abdominal muscle stimulator unit on an implantable cardioverter defibrillator: report of two consecutive cases. Pacing Clin Electrophysiol 26:1292e3CrossRef Wayar L, Mont L, Silva RMFL et al (2003) Electrical interference from an abdominal muscle stimulator unit on an implantable cardioverter defibrillator: report of two consecutive cases. Pacing Clin Electrophysiol 26:1292e3CrossRef
6.
Zurück zum Zitat Sabate X, Moure C, Nicolas J et al (2001) Washing machine associated 50 Hz detected as ventricular fibrillation by an implanted cardioverter defibrillator. Pacing Clin Electrophysiol 24:1281e3CrossRef Sabate X, Moure C, Nicolas J et al (2001) Washing machine associated 50 Hz detected as ventricular fibrillation by an implanted cardioverter defibrillator. Pacing Clin Electrophysiol 24:1281e3CrossRef
7.
Zurück zum Zitat Diez C, Hofmann HS, Börgermann J (2009) Atrial and ventricular lead insulation defects with resulting inappropriate shocks and end-of-life of the ICD impulse generator in a young bodybuilder with congenital long-QT syndrome. J Clin Res Cardiol 98(1):16–18 [Epub 2008 Sep 5] Diez C, Hofmann HS, Börgermann J (2009) Atrial and ventricular lead insulation defects with resulting inappropriate shocks and end-of-life of the ICD impulse generator in a young bodybuilder with congenital long-QT syndrome. J Clin Res Cardiol 98(1):16–18 [Epub 2008 Sep 5]
8.
Zurück zum Zitat Vlay SC (2002) Fish pond electromagnetic interference resulting in an inappropriate implantable cardioverter defibrillator shock. Pacing Clin Electrophysiol 25:1532CrossRefPubMed Vlay SC (2002) Fish pond electromagnetic interference resulting in an inappropriate implantable cardioverter defibrillator shock. Pacing Clin Electrophysiol 25:1532CrossRefPubMed
9.
Zurück zum Zitat Hauck M, Bauer A, Voss F, Weretka S et al (2009) “Home monitoring” for early detection of implantable cardioverter-defibrillator failure: a single-center prospective observational study. Clin Res Cardiol 98(1):19–24 [Epub 2008 Sep 5] Hauck M, Bauer A, Voss F, Weretka S et al (2009) “Home monitoring” for early detection of implantable cardioverter-defibrillator failure: a single-center prospective observational study. Clin Res Cardiol 98(1):19–24 [Epub 2008 Sep 5]
Metadaten
Titel
Inappropriate shock delivery by implantable cardioverter defibrillator due to electrical leak from bathroom tap
verfasst von
Ahmet Çamsarı
Dilek Çiçek Yılmaz
Türkay Özcan
Publikationsdatum
01.11.2010
Verlag
Springer-Verlag
Erschienen in
Clinical Research in Cardiology / Ausgabe 11/2010
Print ISSN: 1861-0684
Elektronische ISSN: 1861-0692
DOI
https://doi.org/10.1007/s00392-010-0202-2

Weitere Artikel der Ausgabe 11/2010

Clinical Research in Cardiology 11/2010 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.