Skip to main content
Erschienen in: Clinical Research in Cardiology 6/2018

16.02.2018 | Original Paper

Patient-specific registration of 3D CT angiography (CTA) with X-ray fluoroscopy for image fusion during transcatheter aortic valve implantation (TAVI) increases performance of the procedure

verfasst von: I. Vernikouskaya, W. Rottbauer, J. Seeger, B. Gonska, V. Rasche, Jochen Wöhrle

Erschienen in: Clinical Research in Cardiology | Ausgabe 6/2018

Einloggen, um Zugang zu erhalten

Abstract

Objectives

The aim of this study was to adapt patient-specifically a co-registration procedure for image fusion (IF) of a pre-interventional CT dataset with real-time X-ray (XR) fluoroscopy during transfemoral transcatheter aortic valve implantation (TAVI), enabling improved performance of the procedure.

Background

The ability to use 3D models of the respective anatomies to complement the anatomic information obtained by XR fluoroscopy and provide a greater degree of real-time anatomical guidance holds great potential for complex cardiac interventions, especially for TAVI procedures with cerebral protection.

Methods

Initial registration of two datasets was performed during the femoral puncture and sheath introduction using routinely acquired arteriographies. On-time refinement of the co-registration was then performed during the on-going procedure avoiding additional angiograms for the co-registration. Performance of the method was evaluated quantitatively in terms of procedural characteristics and clinical events.

Results

Significant reduction of the radiation dose [51 (42–55) vs. 64 (49–81) Gy cm2, p = 0.032] and contrast agent (CA) volume [80 (50–95) vs. 100 (80–110) ml, p = 0.010] was achieved with the optimized approach as compared to the control group without IF, with simultaneous decrease of procedural [48 (41–58) vs. 61 (53–67) min, p = 0.002] and fluoroscopy times [14.8 (12.7–18.5) vs. 17.8 (14.3–19.4), p = 0.108].

Conclusions

In this proof-of-concept study we have demonstrated a novel co-registration approach for IF during TAVI not requiring any additional CA or XR scan. We have evaluated its potential benefit with the strong focus on guiding the femoral puncture, placement of the double-filter cerebral embolic protection device, and deployment of the valve prosthesis. We achieved improved performance and safety of the procedure with the introduced approach.
Literatur
1.
Zurück zum Zitat Sánchez Y, Anvari A, Samir AE, Arellano RS, Prabhakar AM, Uppot RN (2017) Navigational guidance and ablation planning tools for interventional radiology. Curr Probl Diagn Radiol 46(3):225–233CrossRefPubMed Sánchez Y, Anvari A, Samir AE, Arellano RS, Prabhakar AM, Uppot RN (2017) Navigational guidance and ablation planning tools for interventional radiology. Curr Probl Diagn Radiol 46(3):225–233CrossRefPubMed
2.
Zurück zum Zitat Schwein A, Chinnadurai P, Shah DJ, Lumsden AB, Bechara CF, Bismuth J (2017) Feasibility of three-dimensional magnetic resonance angiography-fluoroscopy image fusion technique in guiding complex endovascular aortic procedures in patients with renal insufficiency. J Vasc Surg 65(5):1440–1452CrossRefPubMed Schwein A, Chinnadurai P, Shah DJ, Lumsden AB, Bechara CF, Bismuth J (2017) Feasibility of three-dimensional magnetic resonance angiography-fluoroscopy image fusion technique in guiding complex endovascular aortic procedures in patients with renal insufficiency. J Vasc Surg 65(5):1440–1452CrossRefPubMed
3.
Zurück zum Zitat Ierardi AM, Duka E, Radaelli A, Rivolta N, Piffaretti G, Carrafiello G (2015) Fusion of CT angiography or MR angiography with unenhanced CBCT and fluoroscopy guidance in endovascular treatments of aorto-iliac steno-occlusion: technical note on a preliminary experience. Cardiovasc Intervent Radiol 39(1):111–116CrossRefPubMed Ierardi AM, Duka E, Radaelli A, Rivolta N, Piffaretti G, Carrafiello G (2015) Fusion of CT angiography or MR angiography with unenhanced CBCT and fluoroscopy guidance in endovascular treatments of aorto-iliac steno-occlusion: technical note on a preliminary experience. Cardiovasc Intervent Radiol 39(1):111–116CrossRefPubMed
4.
Zurück zum Zitat Sailer AM, de Haan MW, Peppelenbosch AG, Jacobs MJ, Wildberger JE, Schurink GWH (2014) CTA with fluoroscopy image fusion guidance in endovascular complex aortic aneurysm repair. Eur J Vasc Endovasc Surg 47(4):349–356CrossRefPubMed Sailer AM, de Haan MW, Peppelenbosch AG, Jacobs MJ, Wildberger JE, Schurink GWH (2014) CTA with fluoroscopy image fusion guidance in endovascular complex aortic aneurysm repair. Eur J Vasc Endovasc Surg 47(4):349–356CrossRefPubMed
5.
Zurück zum Zitat McNally MM, Scali ST, Feezor RJ, Neal D, Huber TS, Beck AW (2015) Three dimensional fusion CT decreases radiation exposure, procedure time and contrast use during fenestrated endovascular aortic repair. J Vasc Surg 61(2):309–316CrossRefPubMed McNally MM, Scali ST, Feezor RJ, Neal D, Huber TS, Beck AW (2015) Three dimensional fusion CT decreases radiation exposure, procedure time and contrast use during fenestrated endovascular aortic repair. J Vasc Surg 61(2):309–316CrossRefPubMed
6.
Zurück zum Zitat Krishnaswamy A, Tuzcu EM, Kapadia SR (2015) Integration of MDCT and fluoroscopy using C-arm computed tomography to guide structural cardiac interventions in the cardiac catheterization laboratory. Catheter Cardiovasc Interv 85(1):139–147CrossRefPubMed Krishnaswamy A, Tuzcu EM, Kapadia SR (2015) Integration of MDCT and fluoroscopy using C-arm computed tomography to guide structural cardiac interventions in the cardiac catheterization laboratory. Catheter Cardiovasc Interv 85(1):139–147CrossRefPubMed
7.
Zurück zum Zitat Movassaghi B, Rasche V, Grass M, Viergever MA, Niessen WJ (2004) A quantitative analysis of 3-D coronary modeling from two or more projection images. IEEE Trans Med Imaging 23(12):1517–1531CrossRefPubMed Movassaghi B, Rasche V, Grass M, Viergever MA, Niessen WJ (2004) A quantitative analysis of 3-D coronary modeling from two or more projection images. IEEE Trans Med Imaging 23(12):1517–1531CrossRefPubMed
8.
Zurück zum Zitat Vernikouskaya I, Rottbauer W, Gonska B, Rodewald C, Seeger J, Rasche V, Wöhrle J (2017) Image-guidance for transcatheter aortic valve implantation (TAVI) and cerebral embolic protection. Int J Cardiol 249:90–95CrossRefPubMed Vernikouskaya I, Rottbauer W, Gonska B, Rodewald C, Seeger J, Rasche V, Wöhrle J (2017) Image-guidance for transcatheter aortic valve implantation (TAVI) and cerebral embolic protection. Int J Cardiol 249:90–95CrossRefPubMed
9.
Zurück zum Zitat Panigrahy A, Caruthers SD, Krejza J, Barnes PD, Faddoul SG, Sleeper LA et al (2000) Registration of three-dimensional MR and CT studies of the cervical spine. Am J Neuroradiol 21(2):282–289PubMed Panigrahy A, Caruthers SD, Krejza J, Barnes PD, Faddoul SG, Sleeper LA et al (2000) Registration of three-dimensional MR and CT studies of the cervical spine. Am J Neuroradiol 21(2):282–289PubMed
10.
Zurück zum Zitat Auffret V, Lefevre T, Van Belle E, Eltchaninoff H, Iung B, Koning R et al (2017) Temporal trends in transcatheter aortic valve replacement in France: FRANCE 2 to FRANCE TAVI. J Am Coll Cardiol 70(1):42–55CrossRefPubMed Auffret V, Lefevre T, Van Belle E, Eltchaninoff H, Iung B, Koning R et al (2017) Temporal trends in transcatheter aortic valve replacement in France: FRANCE 2 to FRANCE TAVI. J Am Coll Cardiol 70(1):42–55CrossRefPubMed
11.
Zurück zum Zitat Thourani VH, Kodali S, Makkar RR, Herrmann HC, Williams M, Babaliaros V et al (2016) Transcatheter aortic valve replacement versus surgical valve replacement in intermediate-risk patients: a propensity score analysis. Lancet 387(10034):2218–2225CrossRefPubMed Thourani VH, Kodali S, Makkar RR, Herrmann HC, Williams M, Babaliaros V et al (2016) Transcatheter aortic valve replacement versus surgical valve replacement in intermediate-risk patients: a propensity score analysis. Lancet 387(10034):2218–2225CrossRefPubMed
12.
Zurück zum Zitat Doenst T, Strüning C, Moschovas A, Gonzalez-Lopez D, Essa Y, Kirov H et al (2016) Cardiac surgery 2015 reviewed. Clin Res Cardiol 105(10):801–814CrossRefPubMed Doenst T, Strüning C, Moschovas A, Gonzalez-Lopez D, Essa Y, Kirov H et al (2016) Cardiac surgery 2015 reviewed. Clin Res Cardiol 105(10):801–814CrossRefPubMed
13.
Zurück zum Zitat Gaede L, Blumenstein J, Kim W-K, Liebetrau C, Dörr O, Nef H et al (2017) Trends in aortic valve replacement in Germany in 2015: transcatheter versus isolated surgical aortic valve repair. Clin Res Cardiol 106(6):411–419CrossRefPubMed Gaede L, Blumenstein J, Kim W-K, Liebetrau C, Dörr O, Nef H et al (2017) Trends in aortic valve replacement in Germany in 2015: transcatheter versus isolated surgical aortic valve repair. Clin Res Cardiol 106(6):411–419CrossRefPubMed
14.
Zurück zum Zitat Ramlawi B, Anaya-Ayala JE, Reardon MJ (2012) Transcatheter aortic valve replacement (TAVR): access planning and strategies. Methodist DeBakey Cardiovasc J 8(2):22–25CrossRefPubMedPubMedCentral Ramlawi B, Anaya-Ayala JE, Reardon MJ (2012) Transcatheter aortic valve replacement (TAVR): access planning and strategies. Methodist DeBakey Cardiovasc J 8(2):22–25CrossRefPubMedPubMedCentral
15.
Zurück zum Zitat Seidler T, Hünlich M, Puls M, Hasenfuß G, Jacobshagen C (2017) Feasibility and outcomes of interventional treatment for vascular access site complications following transfemoral aortic valve implantation. Clin Res Cardiol 106(3):183–191CrossRefPubMed Seidler T, Hünlich M, Puls M, Hasenfuß G, Jacobshagen C (2017) Feasibility and outcomes of interventional treatment for vascular access site complications following transfemoral aortic valve implantation. Clin Res Cardiol 106(3):183–191CrossRefPubMed
16.
Zurück zum Zitat Thirumala PD, Nguyen FD, Mehta A, Schindler J, Mulukutla S, Jeevanantham V et al (2017) Perioperative stroke, in-hospital mortality, and postoperative morbidity following transcatheter aortic valve implantation: a nationwide study. J Clin Neurol 13(4):351–358CrossRefPubMedPubMedCentral Thirumala PD, Nguyen FD, Mehta A, Schindler J, Mulukutla S, Jeevanantham V et al (2017) Perioperative stroke, in-hospital mortality, and postoperative morbidity following transcatheter aortic valve implantation: a nationwide study. J Clin Neurol 13(4):351–358CrossRefPubMedPubMedCentral
17.
Zurück zum Zitat Altisent OA-J, Ferreira-Gonzalez I, Marsal JR, Ribera A, Auger C, Ortega G et al (2016) Neurological damage after transcatheter aortic valve implantation compared with surgical aortic valve replacement in intermediate risk patients. Clin Res Cardiol 105(6):508–517CrossRef Altisent OA-J, Ferreira-Gonzalez I, Marsal JR, Ribera A, Auger C, Ortega G et al (2016) Neurological damage after transcatheter aortic valve implantation compared with surgical aortic valve replacement in intermediate risk patients. Clin Res Cardiol 105(6):508–517CrossRef
18.
Zurück zum Zitat Jobanputra Y, Jones BM, Mohananey D, Fatima B, Kandregula K, Kapadia S (2017) Cerebral protection devices for transcatheter aortic valve replacement. Expert Rev Med Devices 14(7):529–543CrossRefPubMed Jobanputra Y, Jones BM, Mohananey D, Fatima B, Kandregula K, Kapadia S (2017) Cerebral protection devices for transcatheter aortic valve replacement. Expert Rev Med Devices 14(7):529–543CrossRefPubMed
19.
Zurück zum Zitat Bernhardt P, Rodewald C, Seeger J, Gonska B, Buckert D, Radermacher M et al (2016) Non-contrast-enhanced magnetic resonance angiography is equal to contrast-enhanced multislice computed tomography for correct aortic sizing before transcatheter aortic valve implantation. Clin Res Cardiol 105(3):273–278CrossRefPubMed Bernhardt P, Rodewald C, Seeger J, Gonska B, Buckert D, Radermacher M et al (2016) Non-contrast-enhanced magnetic resonance angiography is equal to contrast-enhanced multislice computed tomography for correct aortic sizing before transcatheter aortic valve implantation. Clin Res Cardiol 105(3):273–278CrossRefPubMed
20.
Zurück zum Zitat Kim W-K, Liebetrau C, Linden A van, Blumenstein J, Gaede L, Hamm CW et al (2016) Myocardial injury associated with transcatheter aortic valve implantation (TAVI). Clin Res Cardiol 105(5):379–387CrossRefPubMed Kim W-K, Liebetrau C, Linden A van, Blumenstein J, Gaede L, Hamm CW et al (2016) Myocardial injury associated with transcatheter aortic valve implantation (TAVI). Clin Res Cardiol 105(5):379–387CrossRefPubMed
21.
Zurück zum Zitat Karambatsakidou A, Omar A, Chehrazi B, Rück A, Scherp Nilsson J, Fransson A (2016) SKIN dose, effective dose and related risk in transcatheter aortic valve implantation (TAVI) procedures: is the cancer risk acceptable for younger patients? Radiat Prot Dosimetry 169(1–4):225–231CrossRefPubMed Karambatsakidou A, Omar A, Chehrazi B, Rück A, Scherp Nilsson J, Fransson A (2016) SKIN dose, effective dose and related risk in transcatheter aortic valve implantation (TAVI) procedures: is the cancer risk acceptable for younger patients? Radiat Prot Dosimetry 169(1–4):225–231CrossRefPubMed
22.
Zurück zum Zitat Möllmann H, Bestehorn K, Bestehorn M, Papoutsis K, Fleck E, Ertl G et al (2016) In-hospital outcome of transcatheter vs. surgical aortic valve replacement in patients with aortic valve stenosis: complete dataset of patients treated in 2013 in Germany. Clin Res Cardiol 105(6):553–559CrossRefPubMed Möllmann H, Bestehorn K, Bestehorn M, Papoutsis K, Fleck E, Ertl G et al (2016) In-hospital outcome of transcatheter vs. surgical aortic valve replacement in patients with aortic valve stenosis: complete dataset of patients treated in 2013 in Germany. Clin Res Cardiol 105(6):553–559CrossRefPubMed
23.
Zurück zum Zitat Gülker J-E, Schott P, Katoh M, Bufe A (2016) Case report: Cerebral stentretreiver thrombectomy of an embolized valve fragment after valve in valve TAVI. Clin Res Cardiol 105(4):372–375CrossRefPubMed Gülker J-E, Schott P, Katoh M, Bufe A (2016) Case report: Cerebral stentretreiver thrombectomy of an embolized valve fragment after valve in valve TAVI. Clin Res Cardiol 105(4):372–375CrossRefPubMed
24.
Zurück zum Zitat Kim W-K, Meyer A, Möllmann H, Rolf A, Möllmann S, Blumenstein J et al (2016) Cyclic changes in area- and perimeter-derived effective dimensions of the aortic annulus measured with multislice computed tomography and comparison with metric intraoperative sizing. Clin Res Cardiol 105(7):622–629CrossRefPubMed Kim W-K, Meyer A, Möllmann H, Rolf A, Möllmann S, Blumenstein J et al (2016) Cyclic changes in area- and perimeter-derived effective dimensions of the aortic annulus measured with multislice computed tomography and comparison with metric intraoperative sizing. Clin Res Cardiol 105(7):622–629CrossRefPubMed
25.
Zurück zum Zitat Kim W-K, Blumenstein J, Liebetrau C, Rolf A, Gaede L, Van Linden A et al (2017) Comparison of outcomes using balloon-expandable versus self-expanding transcatheter prostheses according to the extent of aortic valve calcification. Clin Res Cardiol 106(12):995–1004CrossRefPubMed Kim W-K, Blumenstein J, Liebetrau C, Rolf A, Gaede L, Van Linden A et al (2017) Comparison of outcomes using balloon-expandable versus self-expanding transcatheter prostheses according to the extent of aortic valve calcification. Clin Res Cardiol 106(12):995–1004CrossRefPubMed
26.
Zurück zum Zitat Wöhrle J, Gonska B, Rodewald C, Trepte U, Koch S, Scharnbeck D et al (2015) Transfemoral aortic valve implantation with the repositionable Lotus valve compared with the balloon-expandable Edwards Sapien 3 valve. Int J Cardiol 195:171–175CrossRefPubMed Wöhrle J, Gonska B, Rodewald C, Trepte U, Koch S, Scharnbeck D et al (2015) Transfemoral aortic valve implantation with the repositionable Lotus valve compared with the balloon-expandable Edwards Sapien 3 valve. Int J Cardiol 195:171–175CrossRefPubMed
27.
Zurück zum Zitat Gonska B, Seeger J, Rodewald C, Scharnbeck D, Rottbauer W, Wöhrle J (2016) Transfemoral valve-in-valve implantation for degenerated bioprosthetic aortic valves using the new balloon-expandable Edwards Sapien 3 valve. Catheter Cardiovasc Interv 88(4):636–643CrossRefPubMed Gonska B, Seeger J, Rodewald C, Scharnbeck D, Rottbauer W, Wöhrle J (2016) Transfemoral valve-in-valve implantation for degenerated bioprosthetic aortic valves using the new balloon-expandable Edwards Sapien 3 valve. Catheter Cardiovasc Interv 88(4):636–643CrossRefPubMed
28.
Zurück zum Zitat Wöhrle J, Gonska B, Rodewald C, Seeger J, Scharnbeck D, Rottbauer W (2016) Transfemoral aortic valve implantation with the new Edwards Sapien 3 valve for treatment of severe aortic stenosis—impact of valve size in a single center experience. PLOS ONE 11(3):e0151247CrossRefPubMedPubMedCentral Wöhrle J, Gonska B, Rodewald C, Seeger J, Scharnbeck D, Rottbauer W (2016) Transfemoral aortic valve implantation with the new Edwards Sapien 3 valve for treatment of severe aortic stenosis—impact of valve size in a single center experience. PLOS ONE 11(3):e0151247CrossRefPubMedPubMedCentral
29.
Zurück zum Zitat Gonska B, Seeger J, Keßler M, von Keil A, Rottbauer W, Wöhrle J (2017) Predictors for permanent pacemaker implantation in patients undergoing transfemoral aortic valve implantation with the Edwards Sapien 3 valve. Clin Res Cardiol 106(8):590–597CrossRefPubMed Gonska B, Seeger J, Keßler M, von Keil A, Rottbauer W, Wöhrle J (2017) Predictors for permanent pacemaker implantation in patients undergoing transfemoral aortic valve implantation with the Edwards Sapien 3 valve. Clin Res Cardiol 106(8):590–597CrossRefPubMed
30.
Zurück zum Zitat Kappetein AP, Head SJ, Généreux P, Piazza N, van Mieghem NM, Blackstone EH et al (2012) Updated standardized endpoint definitions for transcatheter aortic valve implantation: the valve academic research consortium-2 consensus document (VARC-2). Eur J Cardiothorac Surg 42(5):S45-60CrossRefPubMed Kappetein AP, Head SJ, Généreux P, Piazza N, van Mieghem NM, Blackstone EH et al (2012) Updated standardized endpoint definitions for transcatheter aortic valve implantation: the valve academic research consortium-2 consensus document (VARC-2). Eur J Cardiothorac Surg 42(5):S45-60CrossRefPubMed
31.
Zurück zum Zitat Plank F, Friedrich G, Bartel T, Mueller S, Bonaros N, Heinz A et al (2012) Benefits of high-pitch 128-slice dual-source computed tomography for planning of transcatheter aortic valve implantation. Ann Thorac Surg 94(6):1961–1966CrossRefPubMed Plank F, Friedrich G, Bartel T, Mueller S, Bonaros N, Heinz A et al (2012) Benefits of high-pitch 128-slice dual-source computed tomography for planning of transcatheter aortic valve implantation. Ann Thorac Surg 94(6):1961–1966CrossRefPubMed
32.
Zurück zum Zitat Schmermund A, Marwan M, Hausleiter J, Barth S, Bruder O, Kerber S et al (2017) Declining radiation dose of coronary computed tomography angiography: German cardiac CT registry experience 2009–2014. Clin Res Cardiol 106(11):905–912CrossRefPubMed Schmermund A, Marwan M, Hausleiter J, Barth S, Bruder O, Kerber S et al (2017) Declining radiation dose of coronary computed tomography angiography: German cardiac CT registry experience 2009–2014. Clin Res Cardiol 106(11):905–912CrossRefPubMed
33.
Zurück zum Zitat Ochs MM, Siepen FA dem, Fritz T, Andre F, Gitsioudis G, Korosoglou G et al (2017) Limits of the possible: diagnostic image quality in coronary angiography with third-generation dual-source CT. Clin Res Cardiol 106(7):485–492CrossRefPubMed Ochs MM, Siepen FA dem, Fritz T, Andre F, Gitsioudis G, Korosoglou G et al (2017) Limits of the possible: diagnostic image quality in coronary angiography with third-generation dual-source CT. Clin Res Cardiol 106(7):485–492CrossRefPubMed
34.
Zurück zum Zitat John M, Liao R, Zheng Y, Nöttling A, Boese J, Kirschstein U et al (2010) System to guide transcatheter aortic valve implantations based on interventional C-arm CT imaging. Med Image Comput Comput Assist Interv 13(Pt 1):375–382PubMed John M, Liao R, Zheng Y, Nöttling A, Boese J, Kirschstein U et al (2010) System to guide transcatheter aortic valve implantations based on interventional C-arm CT imaging. Med Image Comput Comput Assist Interv 13(Pt 1):375–382PubMed
35.
Zurück zum Zitat Briguori C, Tavano D, Colombo A (2003) Contrast agent-associated nephrotoxicity. Prog Cardiovasc Dis 45(6):493–503CrossRefPubMed Briguori C, Tavano D, Colombo A (2003) Contrast agent-associated nephrotoxicity. Prog Cardiovasc Dis 45(6):493–503CrossRefPubMed
36.
Zurück zum Zitat Lu Y, Sun Y, Liao R, Ong SH (2014) A pre-operative CT and non-contrast-enhanced C-arm CT registration framework for trans-catheter aortic valve implantation. Comput Med Imaging Graph 38(8):683–695CrossRefPubMed Lu Y, Sun Y, Liao R, Ong SH (2014) A pre-operative CT and non-contrast-enhanced C-arm CT registration framework for trans-catheter aortic valve implantation. Comput Med Imaging Graph 38(8):683–695CrossRefPubMed
37.
Zurück zum Zitat Lauterbach M, Hauptmann KE (2016) Reducing patient radiation dose with image noise reduction technology in transcatheter aortic valve procedures. Am J Cardiol 117(5):834–838CrossRefPubMed Lauterbach M, Hauptmann KE (2016) Reducing patient radiation dose with image noise reduction technology in transcatheter aortic valve procedures. Am J Cardiol 117(5):834–838CrossRefPubMed
38.
Zurück zum Zitat Miller DL, Balter S, Schueler BA, Wagner LK, Strauss KJ, Vañó E (2010) Clinical radiation management for fluoroscopically guided interventional procedures. Radiology 257(2):321–332CrossRefPubMed Miller DL, Balter S, Schueler BA, Wagner LK, Strauss KJ, Vañó E (2010) Clinical radiation management for fluoroscopically guided interventional procedures. Radiology 257(2):321–332CrossRefPubMed
39.
Zurück zum Zitat Chambers CE, Fetterly KA, Holzer R, Lin P-JP, Blankenship JC, Balter S et al (2011) Radiation safety program for the cardiac catheterization laboratory. Catheter Cardiovasc Interv 77(4):546–556CrossRefPubMed Chambers CE, Fetterly KA, Holzer R, Lin P-JP, Blankenship JC, Balter S et al (2011) Radiation safety program for the cardiac catheterization laboratory. Catheter Cardiovasc Interv 77(4):546–556CrossRefPubMed
40.
Zurück zum Zitat Hertault A, Maurel B, Midulla M, Bordier C, Desponds L, Saeed Kilani M et al (2015) Editor’s choice—minimizing radiation exposure during endovascular procedures: basic knowledge, literature review, and reporting standards. Eur J Vasc Endovasc Surg 50(1):21–36CrossRefPubMed Hertault A, Maurel B, Midulla M, Bordier C, Desponds L, Saeed Kilani M et al (2015) Editor’s choice—minimizing radiation exposure during endovascular procedures: basic knowledge, literature review, and reporting standards. Eur J Vasc Endovasc Surg 50(1):21–36CrossRefPubMed
41.
Zurück zum Zitat Thourani VH, Forcillo J, Beohar N, Doshi D, Parvataneni R, Ayele GM et al (2016) Impact of preoperative chronic kidney disease in 2,531 high-risk and inoperable patients undergoing transcatheter aortic valve replacement in the PARTNER trial. Ann Thorac Surg 102(4):1172–1180CrossRefPubMed Thourani VH, Forcillo J, Beohar N, Doshi D, Parvataneni R, Ayele GM et al (2016) Impact of preoperative chronic kidney disease in 2,531 high-risk and inoperable patients undergoing transcatheter aortic valve replacement in the PARTNER trial. Ann Thorac Surg 102(4):1172–1180CrossRefPubMed
42.
Zurück zum Zitat Ewe SH, Delgado V, Ng ACT, Antoni ML, van der Kley F, Marsan NA et al (2011) Outcomes after transcatheter aortic valve implantation: transfemoral versus transapical approach. Ann Thorac Surg 92(4):1244–1251CrossRefPubMed Ewe SH, Delgado V, Ng ACT, Antoni ML, van der Kley F, Marsan NA et al (2011) Outcomes after transcatheter aortic valve implantation: transfemoral versus transapical approach. Ann Thorac Surg 92(4):1244–1251CrossRefPubMed
43.
Zurück zum Zitat Hartrumpf M, Erb M, Zytowski M, Kuehnel R-U, Aigner S, Butter C et al (2015) Radiation exposure and contrast volume differ between transapical and transfemoral aortic valve implantation with the Edwards SAPIEN aortic valve. Thorac Cardiovasc Surg 63(6):479–486CrossRefPubMed Hartrumpf M, Erb M, Zytowski M, Kuehnel R-U, Aigner S, Butter C et al (2015) Radiation exposure and contrast volume differ between transapical and transfemoral aortic valve implantation with the Edwards SAPIEN aortic valve. Thorac Cardiovasc Surg 63(6):479–486CrossRefPubMed
44.
Zurück zum Zitat Yamamoto M, Hayashida K, Mouillet G, Chevalier B, Meguro K, Watanabe Y et al (2013) Renal function–based contrast dosing predicts acute kidney injury following transcatheter aortic valve implantation. JACC Cardiovasc Interv 6(5):479–486CrossRefPubMed Yamamoto M, Hayashida K, Mouillet G, Chevalier B, Meguro K, Watanabe Y et al (2013) Renal function–based contrast dosing predicts acute kidney injury following transcatheter aortic valve implantation. JACC Cardiovasc Interv 6(5):479–486CrossRefPubMed
Metadaten
Titel
Patient-specific registration of 3D CT angiography (CTA) with X-ray fluoroscopy for image fusion during transcatheter aortic valve implantation (TAVI) increases performance of the procedure
verfasst von
I. Vernikouskaya
W. Rottbauer
J. Seeger
B. Gonska
V. Rasche
Jochen Wöhrle
Publikationsdatum
16.02.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Research in Cardiology / Ausgabe 6/2018
Print ISSN: 1861-0684
Elektronische ISSN: 1861-0692
DOI
https://doi.org/10.1007/s00392-018-1212-8

Weitere Artikel der Ausgabe 6/2018

Clinical Research in Cardiology 6/2018 Zur Ausgabe

Update Kardiologie