Skip to main content
Erschienen in: Herzschrittmachertherapie + Elektrophysiologie 2/2020

30.04.2020 | Schwerpunkt

Programming and follow-up of patients with His bundle pacing

verfasst von: Elise Bakelants, MD, Alwin Zweerink, MD, Prof. Haran Burri, MD

Erschienen in: Herzschrittmachertherapie + Elektrophysiologie | Ausgabe 2/2020

Einloggen, um Zugang zu erhalten

Abstract

His bundle pacing (HBP) is being increasingly adopted worldwide, with the aim of providing more physiological stimulation of the heart as opposed to right ventricular pacing or as an alternative to cardiac resynchronization therapy (CRT). Current devices are not specifically designed for HBP, which gives rise to programming challenges. This article aims to provide practical recommendations for HBP programming and follow-up.
Literatur
1.
Zurück zum Zitat Burri H, Keene D, Whinnett Z, Zanon F, Vijayaraman P (2019) Device programming for his bundle pacing. Circ Arrhythm Electrophysiol 12(2):e6816CrossRefPubMedPubMedCentral Burri H, Keene D, Whinnett Z, Zanon F, Vijayaraman P (2019) Device programming for his bundle pacing. Circ Arrhythm Electrophysiol 12(2):e6816CrossRefPubMedPubMedCentral
2.
Zurück zum Zitat Lustgarten DL, Sharma PS, Vijayaraman P (2019) Troubleshooting and programming considerations for his bundle pacing. Heart Rhythm 16(5):654–662CrossRefPubMed Lustgarten DL, Sharma PS, Vijayaraman P (2019) Troubleshooting and programming considerations for his bundle pacing. Heart Rhythm 16(5):654–662CrossRefPubMed
3.
Zurück zum Zitat Abdelrahman M, Subzposh FA, Beer D et al (2018) Clinical outcomes of his bundle pacing compared to right ventricular pacing. J Am Coll Cardiol 71(20):2319–2330CrossRefPubMed Abdelrahman M, Subzposh FA, Beer D et al (2018) Clinical outcomes of his bundle pacing compared to right ventricular pacing. J Am Coll Cardiol 71(20):2319–2330CrossRefPubMed
4.
Zurück zum Zitat Ajijola OA, Upadhyay GA, Macias C, Shivkumar K, Tung R (2017) Permanent his-bundle pacing for cardiac resynchronization therapy: initial feasibility study in lieu of left ventricular lead. Heart Rhythm 14(9):1353–1361CrossRefPubMed Ajijola OA, Upadhyay GA, Macias C, Shivkumar K, Tung R (2017) Permanent his-bundle pacing for cardiac resynchronization therapy: initial feasibility study in lieu of left ventricular lead. Heart Rhythm 14(9):1353–1361CrossRefPubMed
5.
Zurück zum Zitat Vijayaraman P, Herweg B, Ellenbogen KA, Gajek J (2019) His-optimized cardiac resynchronization therapy to maximize electrical resynchronization. Circ Arrhythm Electrophysiol 12(2):e6934CrossRefPubMed Vijayaraman P, Herweg B, Ellenbogen KA, Gajek J (2019) His-optimized cardiac resynchronization therapy to maximize electrical resynchronization. Circ Arrhythm Electrophysiol 12(2):e6934CrossRefPubMed
6.
Zurück zum Zitat Baranchuk A (2020) The ECG in his bundle pacing. Herzschr Elektrophys Baranchuk A (2020) The ECG in his bundle pacing. Herzschr Elektrophys
8.
Zurück zum Zitat Vijayaraman P, Naperkowski A, Subzposh FA et al (2018) Permanent his-bundle pacing: long-term lead performance and clinical outcomes. Heart Rhythm 15(5):696–702CrossRefPubMed Vijayaraman P, Naperkowski A, Subzposh FA et al (2018) Permanent his-bundle pacing: long-term lead performance and clinical outcomes. Heart Rhythm 15(5):696–702CrossRefPubMed
9.
Zurück zum Zitat Sharma PS, Dandamudi G, Herweg B et al (2018) Permanent his-bundle pacing as an alternative to biventricular pacing for cardiac resynchronization therapy: a multicenter experience. Heart Rhythm 15(3):413–420CrossRefPubMed Sharma PS, Dandamudi G, Herweg B et al (2018) Permanent his-bundle pacing as an alternative to biventricular pacing for cardiac resynchronization therapy: a multicenter experience. Heart Rhythm 15(3):413–420CrossRefPubMed
12.
Zurück zum Zitat Starr N, Dayal N, Domenichini G, Stettler C, Burri H (2019) Electrical parameters with his-bundle pacing: considerations for automated programming. Heart Rhythm 16(12):1817–1824CrossRefPubMed Starr N, Dayal N, Domenichini G, Stettler C, Burri H (2019) Electrical parameters with his-bundle pacing: considerations for automated programming. Heart Rhythm 16(12):1817–1824CrossRefPubMed
13.
Zurück zum Zitat Jastrzebski M, Moskal P, Bednarek A, Kielbasa G, Vijayaraman P, Czarnecka D (2019) His bundle has a shorter chronaxie than does the adjacent ventricular myocardium: implications for pacemaker programming. Heart Rhythm 16(12):1808–1816CrossRefPubMed Jastrzebski M, Moskal P, Bednarek A, Kielbasa G, Vijayaraman P, Czarnecka D (2019) His bundle has a shorter chronaxie than does the adjacent ventricular myocardium: implications for pacemaker programming. Heart Rhythm 16(12):1808–1816CrossRefPubMed
Metadaten
Titel
Programming and follow-up of patients with His bundle pacing
verfasst von
Elise Bakelants, MD
Alwin Zweerink, MD
Prof. Haran Burri, MD
Publikationsdatum
30.04.2020
Verlag
Springer Medizin
Erschienen in
Herzschrittmachertherapie + Elektrophysiologie / Ausgabe 2/2020
Print ISSN: 0938-7412
Elektronische ISSN: 1435-1544
DOI
https://doi.org/10.1007/s00399-020-00677-9

Weitere Artikel der Ausgabe 2/2020

Herzschrittmachertherapie + Elektrophysiologie 2/2020 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.