Abstract

Introduction

Anteroposterior pelvic radiographs are routinely used to monitor cup orientation in total hip arthroplasty (THA). Analysis of planar radiographs leads to a certain degree of measurement error for the cup anteversion (AV). With the current study, we wanted to clarify whether planar radiography can be used for accurate evaluation of the THA position.

Materials and methods

The postoperative orientation of pelvic implants in 42 patients was analyzed according to five documented mathematical algorithms using planar radiographs. Postoperative computed tomography (CT) pelvis scans were available for all patients. A CT-based navigation system was used to determine AV.

Results

The comparison showed that all five formulas presented substantial variations for the AV angle. Of these, Widmer’s algorithm presented the smallest difference compared to the CT. Misinterpretation of postoperative planar radiographs is a common problem in THA.

Conclusion

Planar radiographs are too imprecise for exact evaluation of the correct cup AV after THA. CT-based analysis may be necessary if exact values are required.
Literatur
1.
Zurück zum Zitat Ackland MK, Bourne WB, Uhthoff HK (1986) Anteversion of the acetabular cup: measurement of angle after total hip replacement. J Bone Joint Surg Br 68:409–413PubMed Ackland MK, Bourne WB, Uhthoff HK (1986) Anteversion of the acetabular cup: measurement of angle after total hip replacement. J Bone Joint Surg Br 68:409–413PubMed
2.
Zurück zum Zitat Bader R, Scholz R, Steinhauser E, Busch R, Mittelmeier W (2004) Method for the evaluation of factors influencing the dislocation stability of total hip endoprotheses [in German]. Biomed Tech (Berl) 49:137–144CrossRef Bader R, Scholz R, Steinhauser E, Busch R, Mittelmeier W (2004) Method for the evaluation of factors influencing the dislocation stability of total hip endoprotheses [in German]. Biomed Tech (Berl) 49:137–144CrossRef
3.
Zurück zum Zitat Bernsmann K, Langlotz U, Ansari B, Wiese M (2001) Computer-assisted navigated cup placement of different cup types in hip arthroplasty—a randomised controlled trial [in German]. Z Orthop Ihre Grenzgeb 139:512–517PubMedCrossRef Bernsmann K, Langlotz U, Ansari B, Wiese M (2001) Computer-assisted navigated cup placement of different cup types in hip arthroplasty—a randomised controlled trial [in German]. Z Orthop Ihre Grenzgeb 139:512–517PubMedCrossRef
4.
Zurück zum Zitat Coventry MB, Beckenbaugh RD, Nolan DR, Ilstrup DM (1974) 2,012 total hip arthroplasties: a study of postoperative course and early complications. J Bone Joint Surg Am 56:273–284PubMed Coventry MB, Beckenbaugh RD, Nolan DR, Ilstrup DM (1974) 2,012 total hip arthroplasties: a study of postoperative course and early complications. J Bone Joint Surg Am 56:273–284PubMed
5.
Zurück zum Zitat Der G, Everitt BS (2002) A handbook of statistical analyses using SAS. Chapman & Hall, Boca Raton Der G, Everitt BS (2002) A handbook of statistical analyses using SAS. Chapman & Hall, Boca Raton
6.
Zurück zum Zitat DiGioia AM, Jaramaz B, Blackwell M, Simon DA, Morgan F, Moody JE, Nikou C, Colgan BD, Aston CA, Labarca RS, Kischell E, Kanade T (1998) The Otto Aufranc award: image guided navigation system to measure intraoperatively acetabular implant alignment. Clin Orthop 355:8–22PubMedCrossRef DiGioia AM, Jaramaz B, Blackwell M, Simon DA, Morgan F, Moody JE, Nikou C, Colgan BD, Aston CA, Labarca RS, Kischell E, Kanade T (1998) The Otto Aufranc award: image guided navigation system to measure intraoperatively acetabular implant alignment. Clin Orthop 355:8–22PubMedCrossRef
7.
Zurück zum Zitat Fackler CD, Poss R (1980) Dislocation in total hip arthroplasties. Clin Orthop 151:169–178PubMed Fackler CD, Poss R (1980) Dislocation in total hip arthroplasties. Clin Orthop 151:169–178PubMed
8.
Zurück zum Zitat Ghelman B (1979) Radiographic localization of the acetabular component of a hip prosthesis. Radiology 130:540–542PubMed Ghelman B (1979) Radiographic localization of the acetabular component of a hip prosthesis. Radiology 130:540–542PubMed
9.
Zurück zum Zitat Grutzner PA, Zheng G, Langlotz U, von Recum J, Nolte LP, Wentzensen A, Widmer KH, Wendl K (2004) C-arm based navigation in total hip arthroplasty—background and clinical experience. Injury 35(Suppl 1):S5 Grutzner PA, Zheng G, Langlotz U, von Recum J, Nolte LP, Wentzensen A, Widmer KH, Wendl K (2004) C-arm based navigation in total hip arthroplasty—background and clinical experience. Injury 35(Suppl 1):S5
10.
Zurück zum Zitat Hassan DM, Johnston GH, Dust WN, Watson G, Dolovich AT (1998) Accuracy of intraoperative assessment of acetabular prosthesis placement. J Arthroplasty 13:80–84PubMedCrossRef Hassan DM, Johnston GH, Dust WN, Watson G, Dolovich AT (1998) Accuracy of intraoperative assessment of acetabular prosthesis placement. J Arthroplasty 13:80–84PubMedCrossRef
11.
Zurück zum Zitat Herrlin K, Pettersson H, Selvik G (1988) Comparison of two- and three-dimensional methods for assessment of orientation of the total hip prosthesis. Acta Radiol 29:357–361PubMedCrossRef Herrlin K, Pettersson H, Selvik G (1988) Comparison of two- and three-dimensional methods for assessment of orientation of the total hip prosthesis. Acta Radiol 29:357–361PubMedCrossRef
12.
Zurück zum Zitat Jaramaz B, DiGioia AM III, Blackwell M, Nikou C (1998) Computer assisted measurement of cup placement in total hip replacement. Clin Orthop 354:70–81PubMedCrossRef Jaramaz B, DiGioia AM III, Blackwell M, Nikou C (1998) Computer assisted measurement of cup placement in total hip replacement. Clin Orthop 354:70–81PubMedCrossRef
13.
Zurück zum Zitat Langlotz U, Lawrence J, Hu Q, Langlotz F, Nolte LP (1999) Image guided cup placement. In: Lemke HU, Vannier MW, Inamura K, Farman AG (eds) Computer assisted radiology and surgery. Elsevier, Amsterdam, pp 717–721 Langlotz U, Lawrence J, Hu Q, Langlotz F, Nolte LP (1999) Image guided cup placement. In: Lemke HU, Vannier MW, Inamura K, Farman AG (eds) Computer assisted radiology and surgery. Elsevier, Amsterdam, pp 717–721
14.
Zurück zum Zitat Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmermann JR (1978) Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am 60:217–220PubMed Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmermann JR (1978) Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am 60:217–220PubMed
15.
Zurück zum Zitat McCollum DE, Gray WJ (1990) Dislocation after total hip arthroplasty: causes and prevention. Clin Orthop 261:159–170PubMed McCollum DE, Gray WJ (1990) Dislocation after total hip arthroplasty: causes and prevention. Clin Orthop 261:159–170PubMed
16.
Zurück zum Zitat McLaren RH (1973) Prosthetic hip angulation. Radiology 107:705–706PubMed McLaren RH (1973) Prosthetic hip angulation. Radiology 107:705–706PubMed
17.
Zurück zum Zitat Müller ME (1974) Total hip prosthesis. Clin Orthop 72:46–68 Müller ME (1974) Total hip prosthesis. Clin Orthop 72:46–68
18.
Zurück zum Zitat Murray DW (1993) The definition and measurement of acetabular orientation. J Bone Joint Surg Br 75:228–232PubMed Murray DW (1993) The definition and measurement of acetabular orientation. J Bone Joint Surg Br 75:228–232PubMed
19.
Zurück zum Zitat Olivecrona H, Weidenhielm L, Olivecrona L, Beckman MO, Stark A, Noz ME, Maguire GQ Jr, Zeleznik MP, Svensson L, Jonson T (2004) A new CT method for measuring cup orientation after total hip arthroplasty: a study of 10 patients. Acta Orthop Scand 75:252–260PubMedCrossRef Olivecrona H, Weidenhielm L, Olivecrona L, Beckman MO, Stark A, Noz ME, Maguire GQ Jr, Zeleznik MP, Svensson L, Jonson T (2004) A new CT method for measuring cup orientation after total hip arthroplasty: a study of 10 patients. Acta Orthop Scand 75:252–260PubMedCrossRef
20.
Zurück zum Zitat Pierchon F, Pasquier G, Cotten A, Fontaine C, Clarisse J, Duquennoy A (1994) Causes of dislocation of total hip arthroplasty: CT study of component alignment. J Bone Joint Surg Br 76:45–48PubMed Pierchon F, Pasquier G, Cotten A, Fontaine C, Clarisse J, Duquennoy A (1994) Causes of dislocation of total hip arthroplasty: CT study of component alignment. J Bone Joint Surg Br 76:45–48PubMed
21.
Zurück zum Zitat Pradhan R (1999) Planar anteversion of the acetabular cup as determined from plain anteroposterior radiographs. J Bone Joint Surg Br 81:431–435PubMedCrossRef Pradhan R (1999) Planar anteversion of the acetabular cup as determined from plain anteroposterior radiographs. J Bone Joint Surg Br 81:431–435PubMedCrossRef
22.
Zurück zum Zitat Saxler G, Marx A, Vandevelde D, Langlotz U, Tannast M, Wiese M, Michaelis U, Kemper G, Grutzner PA, Steffen R, von Knoch M, Holland-Letz T, Bernsmann K (2004) The accuracy of free-hand cup positioning: a CT based measurement of cup placement in 105 total hip arthroplasties. Int Orthop 28:198–201PubMedCrossRef Saxler G, Marx A, Vandevelde D, Langlotz U, Tannast M, Wiese M, Michaelis U, Kemper G, Grutzner PA, Steffen R, von Knoch M, Holland-Letz T, Bernsmann K (2004) The accuracy of free-hand cup positioning: a CT based measurement of cup placement in 105 total hip arthroplasties. Int Orthop 28:198–201PubMedCrossRef
23.
Zurück zum Zitat Saxler G, Marx A, Vandevelde D, Langlotz U, Tannast M, Wiese M, Michaelis U, Kemper G, Grutzner PA, Steffen R, von Knoch M, Holland-Letz T, Bernsmann K (2004) Cup placement in hip replacement surgery: a comparison of free-hand and computer assisted cup placement in total hip arthroplasty—a multi-center study [in German]. Z Orthop Ihre Grenzgeb 142:286–291PubMedCrossRef Saxler G, Marx A, Vandevelde D, Langlotz U, Tannast M, Wiese M, Michaelis U, Kemper G, Grutzner PA, Steffen R, von Knoch M, Holland-Letz T, Bernsmann K (2004) Cup placement in hip replacement surgery: a comparison of free-hand and computer assisted cup placement in total hip arthroplasty—a multi-center study [in German]. Z Orthop Ihre Grenzgeb 142:286–291PubMedCrossRef
24.
Zurück zum Zitat Seradge H, Nagle KR, Miller RJ (1982) Analysis of version in the acetabular cup. Clin Orthop 166:152–157PubMed Seradge H, Nagle KR, Miller RJ (1982) Analysis of version in the acetabular cup. Clin Orthop 166:152–157PubMed
25.
Zurück zum Zitat Tannast M (2000) The measurement of anteversion and inclination with respect to the pelvic frontal plane [in German]. M.D. Thesis, University of Bern, Medical Faculty Tannast M (2000) The measurement of anteversion and inclination with respect to the pelvic frontal plane [in German]. M.D. Thesis, University of Bern, Medical Faculty
26.
Zurück zum Zitat Tannast M, Langlotz U, Siebenrock KA, Wiese M, Bernsmann K, Langlotz F (2005) Anatomic referencing of cup orientation in total hip arthroplasty. Clin Orthop 436:144–150PubMed Tannast M, Langlotz U, Siebenrock KA, Wiese M, Bernsmann K, Langlotz F (2005) Anatomic referencing of cup orientation in total hip arthroplasty. Clin Orthop 436:144–150PubMed
27.
Zurück zum Zitat Wentzensen A, Zheng G, Vock B, Langlotz U, Korber J, Nolte LP, Grutzner PA (2003) Image-based hip navigation. Int Orthop 27(Suppl 1):S43–S46PubMed Wentzensen A, Zheng G, Vock B, Langlotz U, Korber J, Nolte LP, Grutzner PA (2003) Image-based hip navigation. Int Orthop 27(Suppl 1):S43–S46PubMed
28.
Zurück zum Zitat Widmer KH (2004) A simplified method to determine acetabular cup anteversion from plain radiographs. J Arthroplasty 19:387–390PubMedCrossRef Widmer KH (2004) A simplified method to determine acetabular cup anteversion from plain radiographs. J Arthroplasty 19:387–390PubMedCrossRef
29.
Zurück zum Zitat Widmer KH, Zurfluh B (2004) Compliant positioning of total hip components for optimal range of motion. J Orthop Res 22:815–821PubMedCrossRef Widmer KH, Zurfluh B (2004) Compliant positioning of total hip components for optimal range of motion. J Orthop Res 22:815–821PubMedCrossRef
30.
Zurück zum Zitat Zheng G, Marx A, Langlotz U, Widmer KH, Buttaro M, Nolte LP (2002) A hybrid CT-free navigation system for total hip arthroplasty. Comput Aided Surg 7:129–145PubMed Zheng G, Marx A, Langlotz U, Widmer KH, Buttaro M, Nolte LP (2002) A hybrid CT-free navigation system for total hip arthroplasty. Comput Aided Surg 7:129–145PubMed
Metadaten
Titel
Misinterpretation of cup anteversion in total hip arthroplasty using planar radiography
verfasst von
Axel Marx
Marius von Knoch
Jörg Pförtner
Matthias Wiese
Guido Saxler
Publikationsdatum
01.09.2006
Verlag
Springer-Verlag
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 7/2006
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-006-0163-0

Weitere Artikel der Ausgabe 7/2006

Archives of Orthopaedic and Trauma Surgery 7/2006 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.