Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 11/2011

01.11.2011 | Knee Revision Surgery

Implant survival and outcome after rotating-hinge total knee revision arthroplasty: a minimum 6-year follow-up

verfasst von: Asgeir Gudnason, Jan Milbrink, Nils P. Hailer

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 11/2011

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Data on long-time survival and clinical function of rotating hinge knee prostheses used in revision total knee arthroplasty (TKA) are scarce.

Method

We evaluate the outcome of 42 revision TKA in 38 patients using the Endo-model rotating hinge total knee prosthesis after a minimum of 6 years, with 10-year implant survival as our primary outcome measure. Only revision TKAs performed due to aseptic loosening were included, and the Swedish Knee Arthroplasty Register was consulted in order to ensure that patients unavailable for clinical follow-up had not been revised elsewhere. Mean follow-up was after 8.8 (6–18) years, mean age at revision surgery was 72 (55–88) years, and most patients had severe medical comorbidities (n = 31).

Results

At follow-up, four knees had been re-revised due to aseptic loosening, and five further knees underwent re-revision due to other reasons. With implant revision due to aseptic loosening as the endpoint, 10-year survival was 89.2%, and with implant revision due to any reason 10-year survival was 65.1%. 11 patients (13 knees) eligible for clinical follow-up were evaluated according to the Hospital for Special Surgery score (HSSS), the Knee Society scores (KSS), and by plain radiography. Mean HSSS was 67 (36–90), mean KSS-knee was 85 (73–96), and mean KSS-function was 29 (0–100). Radiography showed that no implant was in need of revision.

Conclusion

Our results indicate that revision arthroplasty of the knee with this rotating hinge prosthesis can be performed with satisfactory or good results in an elderly population with severe comorbidities.
Literatur
1.
Zurück zum Zitat Ayers DC, Dennis DA, Johanson NA, Pellegrini VD (1997) Common complications of total knee arthroplasty. J Bone Joint Surg Am 79A(2):278–311 Ayers DC, Dennis DA, Johanson NA, Pellegrini VD (1997) Common complications of total knee arthroplasty. J Bone Joint Surg Am 79A(2):278–311
2.
Zurück zum Zitat Bae DK, Song SJ, Yoon KH, Noh JH (2009) Long-term outcome of total knee arthroplasty in charcot joint. J Arthroplast 24(8):1152–1156CrossRef Bae DK, Song SJ, Yoon KH, Noh JH (2009) Long-term outcome of total knee arthroplasty in charcot joint. J Arthroplast 24(8):1152–1156CrossRef
3.
Zurück zum Zitat Barrack RL (2001) Evolution of the rotating hinge for complex total knee arthroplasty. Clin Orthop Relat Res 392:292–299 Barrack RL (2001) Evolution of the rotating hinge for complex total knee arthroplasty. Clin Orthop Relat Res 392:292–299
4.
Zurück zum Zitat Barrack RL (2002) Rise of the rotating hinge in revision total knee arthroplasty. Orthopedics 25(10):1020–1058PubMed Barrack RL (2002) Rise of the rotating hinge in revision total knee arthroplasty. Orthopedics 25(10):1020–1058PubMed
5.
Zurück zum Zitat Barrack RL, Lyons TR, Ingraham RQ, Johnson JC (2000) The use of a modular rotating hinge component in salvage revision total knee arthroplasty. J Arthroplast 15(7):858–866CrossRef Barrack RL, Lyons TR, Ingraham RQ, Johnson JC (2000) The use of a modular rotating hinge component in salvage revision total knee arthroplasty. J Arthroplast 15(7):858–866CrossRef
6.
Zurück zum Zitat Biau DJ, Latouche A, Porcher R (2007) Competing events influence estimated survival probability: When is Kaplan-Meier analysis appropriate? Clin Orthop Relat Res 462:229–233PubMedCrossRef Biau DJ, Latouche A, Porcher R (2007) Competing events influence estimated survival probability: When is Kaplan-Meier analysis appropriate? Clin Orthop Relat Res 462:229–233PubMedCrossRef
7.
Zurück zum Zitat Crova M, Cenna E, Olivero C (2000) Rotating knee prosthesis. Surface or hinge replacement? Orthopäde 29(Suppl 1):S43–S44PubMedCrossRef Crova M, Cenna E, Olivero C (2000) Rotating knee prosthesis. Surface or hinge replacement? Orthopäde 29(Suppl 1):S43–S44PubMedCrossRef
8.
Zurück zum Zitat David HG, Bishay M, James ET (1998) Problems with the rotaflex: a 10 year review of a rotating hinge prosthesis. J Arthroplast 13(4):402–408CrossRef David HG, Bishay M, James ET (1998) Problems with the rotaflex: a 10 year review of a rotating hinge prosthesis. J Arthroplast 13(4):402–408CrossRef
9.
Zurück zum Zitat Garvin KL, Scuderi G, Insall JN (1995) Evolution of the quadriceps snip. Clin Orthop Relat Res 321:131–137 Garvin KL, Scuderi G, Insall JN (1995) Evolution of the quadriceps snip. Clin Orthop Relat Res 321:131–137
10.
Zurück zum Zitat Guenoun B, Latargez L, Freslon M, Defossez G, Salas N, Gayet LE (2009) Complications following rotating hinge endo-modell (link) knee arthroplasty. Orthop Traumatol Surg Res 95(7):529–536PubMedCrossRef Guenoun B, Latargez L, Freslon M, Defossez G, Salas N, Gayet LE (2009) Complications following rotating hinge endo-modell (link) knee arthroplasty. Orthop Traumatol Surg Res 95(7):529–536PubMedCrossRef
11.
Zurück zum Zitat Hossain F, Haddad FS (2010) Midterm assessment of causes and results of revision total knee arthroplasty. Clin Orthop Relat Res 468:1221–1228PubMedCrossRef Hossain F, Haddad FS (2010) Midterm assessment of causes and results of revision total knee arthroplasty. Clin Orthop Relat Res 468:1221–1228PubMedCrossRef
12.
Zurück zum Zitat Hwang SC, Kong JY, Nam DC, Kim DH, Park HB, Jeong ST, Cho SH (2010) Revision total knee arthroplasty with a cemented posterior stabilized, condylar constrained or fully constrained prosthesis: a minimum 2-year follow-up analysis. Clinics Orthop Surg 2(2):112–120CrossRef Hwang SC, Kong JY, Nam DC, Kim DH, Park HB, Jeong ST, Cho SH (2010) Revision total knee arthroplasty with a cemented posterior stabilized, condylar constrained or fully constrained prosthesis: a minimum 2-year follow-up analysis. Clinics Orthop Surg 2(2):112–120CrossRef
13.
Zurück zum Zitat Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the knee society clinical rating system. Clin Orthop Relat Res 248:13–14 Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the knee society clinical rating system. Clin Orthop Relat Res 248:13–14
14.
Zurück zum Zitat Insall JN, Ranawat CS, Aglietti P, Shine J (1976) A comparison of four models of total knee-replacement prostheses. J Bone Joint Surg Am 58(6):754–765PubMed Insall JN, Ranawat CS, Aglietti P, Shine J (1976) A comparison of four models of total knee-replacement prostheses. J Bone Joint Surg Am 58(6):754–765PubMed
15.
Zurück zum Zitat Joshi N, Navarro-Quilis A (2008) Is there a place for rotating-hinge arthroplasty in knee revision surgery for aseptic loosening? J Arthroplast 23(8):1204–1211CrossRef Joshi N, Navarro-Quilis A (2008) Is there a place for rotating-hinge arthroplasty in knee revision surgery for aseptic loosening? J Arthroplast 23(8):1204–1211CrossRef
16.
Zurück zum Zitat Karachalios T, Sarangi PP, Newman JH (1994) Severe varus and valgus deformities treated by total knee arthroplasty. J Bone Joint Surg Br 76(6):938–942PubMed Karachalios T, Sarangi PP, Newman JH (1994) Severe varus and valgus deformities treated by total knee arthroplasty. J Bone Joint Surg Br 76(6):938–942PubMed
17.
Zurück zum Zitat Kurtz S, Mowat F, Ong K, Chan N, Lau E, Halpern M (2005) Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002. J Bone Joint Surg Am 87(7):1487–1497PubMedCrossRef Kurtz S, Mowat F, Ong K, Chan N, Lau E, Halpern M (2005) Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002. J Bone Joint Surg Am 87(7):1487–1497PubMedCrossRef
18.
Zurück zum Zitat Linhardt O, Anders S, Grifka J, Lerch K (2005) Treatment of mechanical damage of the rotating endo-model knee prosthesis. Orthopäde 34(2):167–170PubMedCrossRef Linhardt O, Anders S, Grifka J, Lerch K (2005) Treatment of mechanical damage of the rotating endo-model knee prosthesis. Orthopäde 34(2):167–170PubMedCrossRef
19.
Zurück zum Zitat Lombardi AV Jr, Mallory TH, Eberle RW, Adams JB (1997) Rotating hinge prosthesis in revision total knee arthroplasty: Indications and results. Surg Technol Int 6:379–382PubMed Lombardi AV Jr, Mallory TH, Eberle RW, Adams JB (1997) Rotating hinge prosthesis in revision total knee arthroplasty: Indications and results. Surg Technol Int 6:379–382PubMed
20.
Zurück zum Zitat Ostermeier S, Friesecke C, Fricke S, Hurschler C, Stukenborg-Colsman C (2008) Quadriceps force during knee extension after non-hinged and hinged tka: an in vitro study. Acta Orthop 79(1):34–38PubMedCrossRef Ostermeier S, Friesecke C, Fricke S, Hurschler C, Stukenborg-Colsman C (2008) Quadriceps force during knee extension after non-hinged and hinged tka: an in vitro study. Acta Orthop 79(1):34–38PubMedCrossRef
21.
Zurück zum Zitat Pacha-Vicente D, Malik A, Castellet-Feliu E, Nardi-Vilardaga J (2008) Dislocation of rotating-hinge knee prostheses with antidislocation mechanism. J Arthroplast 23(2):299–303CrossRef Pacha-Vicente D, Malik A, Castellet-Feliu E, Nardi-Vilardaga J (2008) Dislocation of rotating-hinge knee prostheses with antidislocation mechanism. J Arthroplast 23(2):299–303CrossRef
22.
Zurück zum Zitat Petrou G, Petrou H, Tilkeridis C, Stavrakis T, Kapetsis T, Kremmidas N, Gavras M (2004) Medium-term results with a primary cemented rotating-hinge total knee replacement. A 7- to 15-year follow-up. J Bone Joint Surg Br 86(6):813–817PubMedCrossRef Petrou G, Petrou H, Tilkeridis C, Stavrakis T, Kapetsis T, Kremmidas N, Gavras M (2004) Medium-term results with a primary cemented rotating-hinge total knee replacement. A 7- to 15-year follow-up. J Bone Joint Surg Br 86(6):813–817PubMedCrossRef
23.
Zurück zum Zitat Pietsch M, Hofmann S (2007) From tibiofemoral instability to dislocation in total knee arthroplasty. Orthopäde 36(10):917–927PubMedCrossRef Pietsch M, Hofmann S (2007) From tibiofemoral instability to dislocation in total knee arthroplasty. Orthopäde 36(10):917–927PubMedCrossRef
24.
Zurück zum Zitat Pradhan NR, Bale L, Kay P, Porter ML (2004) Salvage revision total knee replacement using the endo-model rotating hinge prosthesis. Knee 11(6):469–473PubMedCrossRef Pradhan NR, Bale L, Kay P, Porter ML (2004) Salvage revision total knee replacement using the endo-model rotating hinge prosthesis. Knee 11(6):469–473PubMedCrossRef
25.
Zurück zum Zitat Radmer S, Andresen R, Sparmann M (2007) Knee arthroplasty using the rotating hinge knee prothesis in patients with rheumatoid arthritis. Aktuelle Rheumatologie 32(1):34–39CrossRef Radmer S, Andresen R, Sparmann M (2007) Knee arthroplasty using the rotating hinge knee prothesis in patients with rheumatoid arthritis. Aktuelle Rheumatologie 32(1):34–39CrossRef
26.
Zurück zum Zitat Ranawat CS, Luessenhop CP, Rodriguez JA (1997) The press-fit condylar modular total knee system. Four-to-six-year results with a posterior-cruciate-substituting design. J Bone Joint Surg Am 79(3):342–348PubMed Ranawat CS, Luessenhop CP, Rodriguez JA (1997) The press-fit condylar modular total knee system. Four-to-six-year results with a posterior-cruciate-substituting design. J Bone Joint Surg Am 79(3):342–348PubMed
27.
Zurück zum Zitat Rand JA, Chao EY, Stauffer RN (1987) Kinematic rotating-hinge total knee arthroplasty. J Bone Joint Surg Am 69(4):489–497PubMed Rand JA, Chao EY, Stauffer RN (1987) Kinematic rotating-hinge total knee arthroplasty. J Bone Joint Surg Am 69(4):489–497PubMed
28.
Zurück zum Zitat Rinta-Kiikka I, Alberty A, Savilahti S, Pajamaki J, Tallroth K, Lindholm TS (1997) The clinical and radiological outcome of the rotating hinged knee prostheses in the long term. Ann Chir Gynaecol 86(4):349–356PubMed Rinta-Kiikka I, Alberty A, Savilahti S, Pajamaki J, Tallroth K, Lindholm TS (1997) The clinical and radiological outcome of the rotating hinged knee prostheses in the long term. Ann Chir Gynaecol 86(4):349–356PubMed
29.
Zurück zum Zitat Robertsson O, Knutson K, Lewold S, Lidgren L (2001) The swedish knee arthroplasty register 1975–1997: an update with special emphasis on 41, 223 knees operated on in 1988–1997. Acta Orthop Scand 72(5):503–513PubMedCrossRef Robertsson O, Knutson K, Lewold S, Lidgren L (2001) The swedish knee arthroplasty register 1975–1997: an update with special emphasis on 41, 223 knees operated on in 1988–1997. Acta Orthop Scand 72(5):503–513PubMedCrossRef
30.
Zurück zum Zitat Sambatakakis A, Wilton TJ, Newton G (1991) Radiographic sign of persistent soft-tissue imbalance after knee replacement. J Bone Joint Surg-Br 73(5):751–756PubMed Sambatakakis A, Wilton TJ, Newton G (1991) Radiographic sign of persistent soft-tissue imbalance after knee replacement. J Bone Joint Surg-Br 73(5):751–756PubMed
31.
Zurück zum Zitat Springer BD, Hanssen AD, Sim FH, Lewallen DG (2001) The kinematic rotating hinge prosthesis for complex knee arthroplasty. Clin Orthop Relat Res 392:283–291 Springer BD, Hanssen AD, Sim FH, Lewallen DG (2001) The kinematic rotating hinge prosthesis for complex knee arthroplasty. Clin Orthop Relat Res 392:283–291
32.
Zurück zum Zitat Steens W, Loehr JF, Wodtke J, Katzer A (2008) Morselized bone grafting in revision arthroplasty of the knee—a retrospective analysis of 34 reconstructions after 2–9 years. Acta Orthopaedica 79(5):683–688PubMedCrossRef Steens W, Loehr JF, Wodtke J, Katzer A (2008) Morselized bone grafting in revision arthroplasty of the knee—a retrospective analysis of 34 reconstructions after 2–9 years. Acta Orthopaedica 79(5):683–688PubMedCrossRef
33.
Zurück zum Zitat Stern SH, Moeckel BH, Insall JN (1991) Total knee arthroplasty in valgus knees. Clin Orthop Relat Res 273:5–8 Stern SH, Moeckel BH, Insall JN (1991) Total knee arthroplasty in valgus knees. Clin Orthop Relat Res 273:5–8
35.
Zurück zum Zitat Walker PS, Manktelow AR (2001) Comparison between a constrained condylar and a rotating hinge in revision knee surgery. Knee 8(4):269–279PubMedCrossRef Walker PS, Manktelow AR (2001) Comparison between a constrained condylar and a rotating hinge in revision knee surgery. Knee 8(4):269–279PubMedCrossRef
36.
Zurück zum Zitat Walldius B (1960) Arthroplasty of the knee using an endoprosthesis. 8 years experience. Acta Orthop Scand 30:137–148PubMed Walldius B (1960) Arthroplasty of the knee using an endoprosthesis. 8 years experience. Acta Orthop Scand 30:137–148PubMed
37.
Zurück zum Zitat Wang CJ, Wang HE (2000) Early catastrophic failure of rotating hinge total knee prosthesis. J Arthroplast 15(3):387–391CrossRef Wang CJ, Wang HE (2000) Early catastrophic failure of rotating hinge total knee prosthesis. J Arthroplast 15(3):387–391CrossRef
38.
Zurück zum Zitat Ward WG, Haight D, Ritchie P, Gordon S, Eckardt JJ (2005) Dislocation of rotating hinge knee prostheses. A report of four cases. J Bone Joint Surg Am 87(5):1108–1112PubMedCrossRef Ward WG, Haight D, Ritchie P, Gordon S, Eckardt JJ (2005) Dislocation of rotating hinge knee prostheses. A report of four cases. J Bone Joint Surg Am 87(5):1108–1112PubMedCrossRef
39.
Zurück zum Zitat Westrich GH, Mollano AV, Sculco TP, Buly RL, Laskin RS, Windsor R (2000) Rotating hinge total knee arthroplasty in severly affected knees. Clin Orthop Relat Res 379:195–208 Westrich GH, Mollano AV, Sculco TP, Buly RL, Laskin RS, Windsor R (2000) Rotating hinge total knee arthroplasty in severly affected knees. Clin Orthop Relat Res 379:195–208
Metadaten
Titel
Implant survival and outcome after rotating-hinge total knee revision arthroplasty: a minimum 6-year follow-up
verfasst von
Asgeir Gudnason
Jan Milbrink
Nils P. Hailer
Publikationsdatum
01.11.2011
Verlag
Springer-Verlag
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 11/2011
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-011-1330-5

Weitere Artikel der Ausgabe 11/2011

Archives of Orthopaedic and Trauma Surgery 11/2011 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.