Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 2/2012

01.02.2012 | Knee Arthroplasty

Navigation in minimally invasive unicompartmental knee arthroplasty has no advantage in comparison to a conventional minimally invasive implantation

verfasst von: Patrick Weber, Sandra Utzschneider, Patrick Sadoghi, Matthias F. Pietschmann, Andreas Ficklscherer, Volkmar Jansson, Peter E. Müller

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 2/2012

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Minimally invasive implantation of unicompartmental knee prostheses can shorten rehabilitation time and lead to better functional results than conventional implantation. Exact positioning of the implant should be achieved, as this is a factor for the long-term survival of the prosthesis, although malpositioning can result due to the poor intraoperative view when using the minimally invasive approach. Navigation of the unicompartmental prosthesis could lead to a better implant positioning without losing the advantages of a minimally invasive approach.

Materials and methods

The same unicondylar knee prosthesis was implanted in a total of 40 patients, of whom 20 were implanted using navigation (kinematic navigation) and 20 using a conventional technique. The operating time was assessed in both groups. The orientation of the tibial and femoral implants was assessed radiologically postoperatively. We analysed these results according to the optimal positioning range proposed by the manufacturer. Furthermore, we examined the clinical results with the knee society score (KSS).

Results

A good positioning of the prosthesis was observed in both techniques with only 11% of the radiologic measurements out of the proposed optimal range in each group. The operating time was significantly longer in the navigation group (17 min). The KSS did not differ between both groups at a follow-up of 16 resp. 18 months (navigated group: 184 points, conventional group: 178 points).

Conclusions

Navigation did not lead to a better positioning of the prosthesis than the conventional method and the operating time was longer. The clinical results were similar in both groups. The navigation may be a useful help for surgeons performing less unicompartmental knee arthroplasty using a minimally invasive approach.
Literatur
2.
Zurück zum Zitat Pandit H, Jenkins C, Barker K, Dodd CA, Murray DW (2006) The Oxford medial unicompartmental knee replacement using a minimally-invasive approach. J Bone Joint Surg Br 88:54–60PubMedCrossRef Pandit H, Jenkins C, Barker K, Dodd CA, Murray DW (2006) The Oxford medial unicompartmental knee replacement using a minimally-invasive approach. J Bone Joint Surg Br 88:54–60PubMedCrossRef
3.
Zurück zum Zitat Repicci JA, Eberle RW (1999) Minimally invasive surgical technique for unicondylar knee arthroplasty. J South Orthop Assoc 8:20–27 Repicci JA, Eberle RW (1999) Minimally invasive surgical technique for unicondylar knee arthroplasty. J South Orthop Assoc 8:20–27
4.
Zurück zum Zitat Müller PE, Pellengahr C, Witt M, Kircher J, Refior HJ, Jansson V (2004) Influence of minimally invasive surgery on implant positioning and the functional outcome for medial unicompartmental knee arthroplasty. J Arthroplasty 19:296–301PubMedCrossRef Müller PE, Pellengahr C, Witt M, Kircher J, Refior HJ, Jansson V (2004) Influence of minimally invasive surgery on implant positioning and the functional outcome for medial unicompartmental knee arthroplasty. J Arthroplasty 19:296–301PubMedCrossRef
5.
Zurück zum Zitat Price AJ, Webb J, Topf H, Dodd CA, Goodfellow JW, Murray DW (2001) Rapid recovery after oxford unicompartmental arthroplasty through a short incision. J Arthroplasty 16:970–976PubMedCrossRef Price AJ, Webb J, Topf H, Dodd CA, Goodfellow JW, Murray DW (2001) Rapid recovery after oxford unicompartmental arthroplasty through a short incision. J Arthroplasty 16:970–976PubMedCrossRef
6.
Zurück zum Zitat Heyse TJ, Efe T, Rumpf S, Schofer MD, Fuchs-Winkelmann S, Schmitt J, Hauk C (2011) Minimally invasive versus conventional unicompartmental knee arthroplasty. Arch Orthop Trauma Surg (Epub ahead of print) Heyse TJ, Efe T, Rumpf S, Schofer MD, Fuchs-Winkelmann S, Schmitt J, Hauk C (2011) Minimally invasive versus conventional unicompartmental knee arthroplasty. Arch Orthop Trauma Surg (Epub ahead of print)
7.
Zurück zum Zitat Fisher DA, Watts M, Davis KE (2003) Implant position in knee surgery: a comparison of minimally invasive, open unicompartmental, and total knee arthroplasty. J Arthroplasty 18:2–8PubMedCrossRef Fisher DA, Watts M, Davis KE (2003) Implant position in knee surgery: a comparison of minimally invasive, open unicompartmental, and total knee arthroplasty. J Arthroplasty 18:2–8PubMedCrossRef
8.
Zurück zum Zitat Jenny JY, Boeri C (2003) Unicompartmental knee prosthesis implantation with a non-image-based navigation system: rationale, technique, case-control comparative study with a conventional instrumented implantation. Knee Surg Sports Traumatol Arthrosc 11:40–45PubMed Jenny JY, Boeri C (2003) Unicompartmental knee prosthesis implantation with a non-image-based navigation system: rationale, technique, case-control comparative study with a conventional instrumented implantation. Knee Surg Sports Traumatol Arthrosc 11:40–45PubMed
9.
Zurück zum Zitat Voss F, Sheinkop MB, Galante JO, Barden RM, Rosenberg AG (1995) Miller-Galante unicompartmental knee arthroplasty at 2- to 5-year follow-up evaluations. J Arthroplasty 10:764–771PubMedCrossRef Voss F, Sheinkop MB, Galante JO, Barden RM, Rosenberg AG (1995) Miller-Galante unicompartmental knee arthroplasty at 2- to 5-year follow-up evaluations. J Arthroplasty 10:764–771PubMedCrossRef
10.
Zurück zum Zitat Cartier P, Sanouiller JL, Grelsamer RP (1996) Unicompartmental knee arthroplasty surgery. 10-year minimum follow-up period. J Arthroplasty 11:782–788PubMedCrossRef Cartier P, Sanouiller JL, Grelsamer RP (1996) Unicompartmental knee arthroplasty surgery. 10-year minimum follow-up period. J Arthroplasty 11:782–788PubMedCrossRef
11.
Zurück zum Zitat Hernigou P, Deschamps G (2004) Posterior slope of the tibial implant and the outcome of unicompartmental knee arthroplasty. J Bone Joint Surg Am 86-A:506–511PubMed Hernigou P, Deschamps G (2004) Posterior slope of the tibial implant and the outcome of unicompartmental knee arthroplasty. J Bone Joint Surg Am 86-A:506–511PubMed
12.
Zurück zum Zitat Decking R, Markmann Y, Fuchs J, Puhl W, Scharf HP (2005) Leg axis after computer-navigated total knee arthroplasty: a prospective randomized trial comparing computer-navigated and manual implantation. J Arthroplasty 20:282–288PubMedCrossRef Decking R, Markmann Y, Fuchs J, Puhl W, Scharf HP (2005) Leg axis after computer-navigated total knee arthroplasty: a prospective randomized trial comparing computer-navigated and manual implantation. J Arthroplasty 20:282–288PubMedCrossRef
13.
Zurück zum Zitat Jenny JY, Clemens U, Kohler S, Kiefer H, Konermann W, Miehlke RK (2005) Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: a case-control study of 235 cases compared with 235 conventionally implanted prostheses. J Arthroplasty 20(2005):832–839PubMedCrossRef Jenny JY, Clemens U, Kohler S, Kiefer H, Konermann W, Miehlke RK (2005) Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: a case-control study of 235 cases compared with 235 conventionally implanted prostheses. J Arthroplasty 20(2005):832–839PubMedCrossRef
14.
Zurück zum Zitat Stockl B, Nogler M, Rosiek R, Fischer M, Krismer M, Kessler O (2004) Navigation improves accuracy of rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 426:180–186PubMedCrossRef Stockl B, Nogler M, Rosiek R, Fischer M, Krismer M, Kessler O (2004) Navigation improves accuracy of rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 426:180–186PubMedCrossRef
15.
Zurück zum Zitat Haaker RG, Wojciechowski M, Patzer P, Willburger RE, Senkal M, Engelhardt M (2006) Minimally invasive unicondylar knee replacement with computer navigation. Orthopade 35:1073–1079PubMedCrossRef Haaker RG, Wojciechowski M, Patzer P, Willburger RE, Senkal M, Engelhardt M (2006) Minimally invasive unicondylar knee replacement with computer navigation. Orthopade 35:1073–1079PubMedCrossRef
16.
Zurück zum Zitat Jung KA, Kim SJ, Lee SC, Hwang SH, Ahn NK (2010) Accuracy of implantation during computer-assisted minimally invasive Oxford unicompartmental knee arthroplasty: a comparison with a conventional instrumented technique. Knee 17:387–391PubMedCrossRef Jung KA, Kim SJ, Lee SC, Hwang SH, Ahn NK (2010) Accuracy of implantation during computer-assisted minimally invasive Oxford unicompartmental knee arthroplasty: a comparison with a conventional instrumented technique. Knee 17:387–391PubMedCrossRef
17.
Zurück zum Zitat Lim MH, Tallay A, Bartlett J (2009) Comparative study of the use of computer assisted navigation system for axial correction in medial unicompartmental knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 17:341–346PubMedCrossRef Lim MH, Tallay A, Bartlett J (2009) Comparative study of the use of computer assisted navigation system for axial correction in medial unicompartmental knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 17:341–346PubMedCrossRef
18.
Zurück zum Zitat Lonner JH, John TK, Conditt MA (2010) Robotic arm-assisted UKA improves tibial component alignment: a pilot study. Clin Orthop Relat Res 468:141–146PubMedCrossRef Lonner JH, John TK, Conditt MA (2010) Robotic arm-assisted UKA improves tibial component alignment: a pilot study. Clin Orthop Relat Res 468:141–146PubMedCrossRef
19.
Zurück zum Zitat Perlick L, Bathis H, Tingart M, Perlick C, Luring C, Grifka J (2004) Minimally invasive unicompartmental knee replacement with a nonimage-based navigation system. Int Orthop 28:193–197PubMedCrossRef Perlick L, Bathis H, Tingart M, Perlick C, Luring C, Grifka J (2004) Minimally invasive unicompartmental knee replacement with a nonimage-based navigation system. Int Orthop 28:193–197PubMedCrossRef
20.
Zurück zum Zitat Rosenberger RE, Fink C, Quirbach S, Attal R, Tecklenburg K, Hoser C (2008) The immediate effect of navigation on implant accuracy in primary mini-invasive unicompartmental knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 16:1133–1140PubMedCrossRef Rosenberger RE, Fink C, Quirbach S, Attal R, Tecklenburg K, Hoser C (2008) The immediate effect of navigation on implant accuracy in primary mini-invasive unicompartmental knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 16:1133–1140PubMedCrossRef
21.
Zurück zum Zitat Seon JK, Song EK, Park SJ, Yoon TR, Lee KB, Jung ST (2009) Comparison of minimally invasive unicompartmental knee arthroplasty with or without a navigation system. J Arthroplasty 24:351–357PubMedCrossRef Seon JK, Song EK, Park SJ, Yoon TR, Lee KB, Jung ST (2009) Comparison of minimally invasive unicompartmental knee arthroplasty with or without a navigation system. J Arthroplasty 24:351–357PubMedCrossRef
22.
Zurück zum Zitat Jenny JY, Müller PE, Weyer R, John M, Weber P, Ciobanu E, Schmitz A, Bacher T, Neumann W, Jansson V (2006) Navigated minimally invasive unicompartmental knee arthroplasty. Orthopedics 29:S117–S121PubMed Jenny JY, Müller PE, Weyer R, John M, Weber P, Ciobanu E, Schmitz A, Bacher T, Neumann W, Jansson V (2006) Navigated minimally invasive unicompartmental knee arthroplasty. Orthopedics 29:S117–S121PubMed
23.
24.
Zurück zum Zitat Dupont WD, Plummer WD (1998) Power and sample size calculations for studies involving linear regression. Control Clin Trials 19:589–601PubMedCrossRef Dupont WD, Plummer WD (1998) Power and sample size calculations for studies involving linear regression. Control Clin Trials 19:589–601PubMedCrossRef
25.
Zurück zum Zitat Cossey AJ, Spriggins AJ (2005) The use of computer-assisted surgical navigation to prevent malalignment in unicompartmental knee arthroplasty. J Arthroplasty 20:29–34PubMedCrossRef Cossey AJ, Spriggins AJ (2005) The use of computer-assisted surgical navigation to prevent malalignment in unicompartmental knee arthroplasty. J Arthroplasty 20:29–34PubMedCrossRef
26.
Zurück zum Zitat Aldinger PR, Gill HS, Schlegel U, Schneider M, Clauss M, Goodfellow JW, Murray DW, Breusch SJ (2004) Is computer navigation a useful tool in unicompartmental knee arthroplasty? A pilot cadaver study. Orthopade 34:1094–1102CrossRef Aldinger PR, Gill HS, Schlegel U, Schneider M, Clauss M, Goodfellow JW, Murray DW, Breusch SJ (2004) Is computer navigation a useful tool in unicompartmental knee arthroplasty? A pilot cadaver study. Orthopade 34:1094–1102CrossRef
27.
Zurück zum Zitat Robertsson O, Knutson K, Lewold S, Lidgren L (2001) The routine of surgical management reduces failure after unicompartmental knee arthroplasty. J Bone Joint Surg Br 83:45–49PubMedCrossRef Robertsson O, Knutson K, Lewold S, Lidgren L (2001) The routine of surgical management reduces failure after unicompartmental knee arthroplasty. J Bone Joint Surg Br 83:45–49PubMedCrossRef
28.
Zurück zum Zitat Gulati A, Pandit H, Jenkins C, Chau R, Dodd CA, Murray DW (2009) The effect of leg alignment on the outcome of unicompartmental knee replacement. J Bone Joint Surg Br 91:469–474PubMedCrossRef Gulati A, Pandit H, Jenkins C, Chau R, Dodd CA, Murray DW (2009) The effect of leg alignment on the outcome of unicompartmental knee replacement. J Bone Joint Surg Br 91:469–474PubMedCrossRef
29.
Zurück zum Zitat Kennedy WR, White RP (1987) Unicompartmental arthroplasty of the knee. Postoperative alignment and its influence on overall results. Clin Orthop Relat Res 221:278–285PubMed Kennedy WR, White RP (1987) Unicompartmental arthroplasty of the knee. Postoperative alignment and its influence on overall results. Clin Orthop Relat Res 221:278–285PubMed
30.
Zurück zum Zitat Hernigou P, Deschamps G (2004) Alignment influences wear in the knee after medial unicompartmental arthroplasty. Clin Orthop Relat Res 423:161–165PubMedCrossRef Hernigou P, Deschamps G (2004) Alignment influences wear in the knee after medial unicompartmental arthroplasty. Clin Orthop Relat Res 423:161–165PubMedCrossRef
31.
Zurück zum Zitat Utzschneider S, Goettinger M, Weber P, Horng A, Glaser C, Jansson V, Müller PE (2011) Development and validation of a new method for the radiologic measurement of the tibial slope. Knee Surg Sports Traumatol Arthrosc (Epub ahead of print) Utzschneider S, Goettinger M, Weber P, Horng A, Glaser C, Jansson V, Müller PE (2011) Development and validation of a new method for the radiologic measurement of the tibial slope. Knee Surg Sports Traumatol Arthrosc (Epub ahead of print)
32.
Zurück zum Zitat Benjamin J (2006) Component alignment in total knee arthroplasty. Instr Course Lect 55:405–412PubMed Benjamin J (2006) Component alignment in total knee arthroplasty. Instr Course Lect 55:405–412PubMed
33.
Zurück zum Zitat Weber P, Schröder C, Utzschneider S, Jansson V, Müller PE (2011) A high tibial slope reduces wear in unicondylar knee arthroplasty [German]. In: Proceedings of the symposium for experimental orthopedics at the orthopedic clinic of the Ludwig–Maximilians University Munich. Unfallchirurg 114, p S13 Weber P, Schröder C, Utzschneider S, Jansson V, Müller PE (2011) A high tibial slope reduces wear in unicondylar knee arthroplasty [German]. In: Proceedings of the symposium for experimental orthopedics at the orthopedic clinic of the Ludwig–Maximilians University Munich. Unfallchirurg 114, p S13
34.
Zurück zum Zitat Diezi C, Wirth S, Meyer DC, Koch PP (2010) Effect of femoral to tibial varus mismatch on the contact area of unicondylar knee prostheses. Knee 17:350–355PubMedCrossRef Diezi C, Wirth S, Meyer DC, Koch PP (2010) Effect of femoral to tibial varus mismatch on the contact area of unicondylar knee prostheses. Knee 17:350–355PubMedCrossRef
35.
Zurück zum Zitat Clarius M, Hauck C, Seeger JB, Pritsch M, Merle C, Aldinger PR (2010) Correlation of positioning and clinical results in Oxford UKA. Int Orthop 34:1145–1151PubMedCrossRef Clarius M, Hauck C, Seeger JB, Pritsch M, Merle C, Aldinger PR (2010) Correlation of positioning and clinical results in Oxford UKA. Int Orthop 34:1145–1151PubMedCrossRef
36.
Zurück zum Zitat Hauptmann SM, Weber P, Glaser C, Birkenmaier C, Jansson V, Muller PE (2008) Free bone cement fragments after minimally invasive unicompartmental knee arthroplasty: an underappreciated problem. Knee Surg Sports Traumatol Arthrosc 16:770–775PubMedCrossRef Hauptmann SM, Weber P, Glaser C, Birkenmaier C, Jansson V, Muller PE (2008) Free bone cement fragments after minimally invasive unicompartmental knee arthroplasty: an underappreciated problem. Knee Surg Sports Traumatol Arthrosc 16:770–775PubMedCrossRef
37.
Zurück zum Zitat Seon JK, Song EK, Yoon TR, Seo HY, Cho SG (2007) Tibial plateau stress fracture after unicondylar knee arthroplasty using a navigation system: two case reports. Knee Surg Sports Traumatol Arthrosc 15:67–70PubMedCrossRef Seon JK, Song EK, Yoon TR, Seo HY, Cho SG (2007) Tibial plateau stress fracture after unicondylar knee arthroplasty using a navigation system: two case reports. Knee Surg Sports Traumatol Arthrosc 15:67–70PubMedCrossRef
38.
Zurück zum Zitat Song MH, Kim BH, Ahn SJ, Yoo SH, Lee MS (2009) Early complications after minimally invasive mobile-bearing medial unicompartmental knee arthroplasty. J Arthroplasty 24:1281–1284PubMedCrossRef Song MH, Kim BH, Ahn SJ, Yoo SH, Lee MS (2009) Early complications after minimally invasive mobile-bearing medial unicompartmental knee arthroplasty. J Arthroplasty 24:1281–1284PubMedCrossRef
39.
Zurück zum Zitat Lewold S, Goodman S, Knutson K, Robertsson O, Lidgren L (1995) Oxford meniscal bearing knee versus the Marmor knee in unicompartmental arthroplasty for arthrosis: a Swedish multicenter survival study. J Arthroplasty 10:722–731PubMedCrossRef Lewold S, Goodman S, Knutson K, Robertsson O, Lidgren L (1995) Oxford meniscal bearing knee versus the Marmor knee in unicompartmental arthroplasty for arthrosis: a Swedish multicenter survival study. J Arthroplasty 10:722–731PubMedCrossRef
40.
Zurück zum Zitat Hamilton WG, Collier MB, Tarabee E, McAuley JP, Engh CA Jr, Engh GA (2006) Incidence and reasons for reoperation after minimally invasive unicompartmental knee arthroplasty. J Arthroplasty 21:98–107PubMedCrossRef Hamilton WG, Collier MB, Tarabee E, McAuley JP, Engh CA Jr, Engh GA (2006) Incidence and reasons for reoperation after minimally invasive unicompartmental knee arthroplasty. J Arthroplasty 21:98–107PubMedCrossRef
41.
Zurück zum Zitat Cerha O, Kirschner S, Gunther KP, Lutzner J (2009) Cost analysis for navigation in knee endoprosthetics. Orthopade 38:1235–1240PubMedCrossRef Cerha O, Kirschner S, Gunther KP, Lutzner J (2009) Cost analysis for navigation in knee endoprosthetics. Orthopade 38:1235–1240PubMedCrossRef
Metadaten
Titel
Navigation in minimally invasive unicompartmental knee arthroplasty has no advantage in comparison to a conventional minimally invasive implantation
verfasst von
Patrick Weber
Sandra Utzschneider
Patrick Sadoghi
Matthias F. Pietschmann
Andreas Ficklscherer
Volkmar Jansson
Peter E. Müller
Publikationsdatum
01.02.2012
Verlag
Springer-Verlag
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 2/2012
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-011-1404-4

Weitere Artikel der Ausgabe 2/2012

Archives of Orthopaedic and Trauma Surgery 2/2012 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.