The optimal method for acetabular socket fixation remains controversial. We present a critical analysis of the current evidence from a systemic literature review of comparative studies, long-term case series, prior literature reviews, meta-analysis, and national arthroplasty registry data for cemented and uncemented acetabular components to determine the respective survivorship rates, overall risk of re-operation, dislocation rates, and wear-related complications. Using contemporary techniques, both cemented and uncemented sockets can yield good long-term results, but our evaluation suggests that the overall/all cause re-operation risk is lower for cemented fixation. Until and unless crosslinked polyethylene (PE) liners or alternative bearings can prove to yield superior outcome in the future, the cemented PE cup remains the gold standard, in all age groups, by which every acetabular component should be compared.
Literatur
1.
Zurück zum Zitat Aldinger PR, Jung AW, Breusch SJ, Ewerbeck V, Parsch D (2009) Survival of the cementless Spotorno stem in the second decade. Clin Orthop Relat Res 467(9):2297–2304PubMedCrossRef Aldinger PR, Jung AW, Breusch SJ, Ewerbeck V, Parsch D (2009) Survival of the cementless Spotorno stem in the second decade. Clin Orthop Relat Res 467(9):2297–2304PubMedCrossRef
2.
Zurück zum Zitat Aldinger PR, Jung AW, Pritsch M, Breusch S, Thomsen M, Ewerbeck V et al (2009) Uncemented grit-blasted straight tapered titanium stems in patients younger than fifty-five years of age. Fifteen to twenty-year results. J Bone Jt Surg Am 91(6):1432–1439CrossRef Aldinger PR, Jung AW, Pritsch M, Breusch S, Thomsen M, Ewerbeck V et al (2009) Uncemented grit-blasted straight tapered titanium stems in patients younger than fifty-five years of age. Fifteen to twenty-year results. J Bone Jt Surg Am 91(6):1432–1439CrossRef
3.
Zurück zum Zitat Aldinger PR, Thomsen M, Lukoschek M, Mau H, Ewerbeck V, Breusch SJ (2004) Long-term fate of uncemented, threaded acetabular components with smooth surface treatment: minimum 10 year follow-up of two different designs. Arch Orthop Trauma Surg 124(7):469–475PubMedCrossRef Aldinger PR, Thomsen M, Lukoschek M, Mau H, Ewerbeck V, Breusch SJ (2004) Long-term fate of uncemented, threaded acetabular components with smooth surface treatment: minimum 10 year follow-up of two different designs. Arch Orthop Trauma Surg 124(7):469–475PubMedCrossRef
4.
Zurück zum Zitat Anseth SD, Pulido PA, Adelson WS, Patil S, Sandwell JC, Colwell CW Jr (2010) Fifteen-year to twenty-year results of cementless Harris-Galante porous femoral and Harris-Galante porous I and II acetabular components. J Arthroplasty 25(5):687–691PubMedCrossRef Anseth SD, Pulido PA, Adelson WS, Patil S, Sandwell JC, Colwell CW Jr (2010) Fifteen-year to twenty-year results of cementless Harris-Galante porous femoral and Harris-Galante porous I and II acetabular components. J Arthroplasty 25(5):687–691PubMedCrossRef
5.
Zurück zum Zitat Atwood SA, Van Citters DW, Patten EW, Furmanski J, Ries MD, Pruitt LA (2011) Tradeoffs amongst fatigue, wear, and oxidation resistance of cross-linked ultra-high molecular weight polyethylene. J Mech Behav Biomed Mater 4(7):1033–1045PubMedCrossRef Atwood SA, Van Citters DW, Patten EW, Furmanski J, Ries MD, Pruitt LA (2011) Tradeoffs amongst fatigue, wear, and oxidation resistance of cross-linked ultra-high molecular weight polyethylene. J Mech Behav Biomed Mater 4(7):1033–1045PubMedCrossRef
6.
Zurück zum Zitat Baker PN, McMurty IA, Chuter G, Port A, Anderson J (2010) THA with the ABG I prosthesis at 15 years. Clin Orthop Relat Res 468:1855–1861PubMedCrossRef Baker PN, McMurty IA, Chuter G, Port A, Anderson J (2010) THA with the ABG I prosthesis at 15 years. Clin Orthop Relat Res 468:1855–1861PubMedCrossRef
7.
Zurück zum Zitat Belmont PJ Jr, Powers CC, Beykirch SE, Hopper RH Jr, Engh CA Jr, Engh CA (2008) Results of the anatomic medullary locking total hip arthroplasty at a minimum of twenty years. A concise follow-up of previous reports. J Bone Jt Surg Am 90(7):1524–1530CrossRef Belmont PJ Jr, Powers CC, Beykirch SE, Hopper RH Jr, Engh CA Jr, Engh CA (2008) Results of the anatomic medullary locking total hip arthroplasty at a minimum of twenty years. A concise follow-up of previous reports. J Bone Jt Surg Am 90(7):1524–1530CrossRef
8.
Zurück zum Zitat Berli BJ, Ping G, Dick W, Morscher EW (2007) Nonmodular flexible press-fit cup in primary total hip arthroplasty: 15 year followup. Clin Orthop Relat Res 461:114–121PubMed Berli BJ, Ping G, Dick W, Morscher EW (2007) Nonmodular flexible press-fit cup in primary total hip arthroplasty: 15 year followup. Clin Orthop Relat Res 461:114–121PubMed
9.
Zurück zum Zitat Berry DJ, Halasy M (2002) Uncemented acetabular components for arthritis after acetabular fracture. Clin Orthop Relat Res (405):164–167 Berry DJ, Halasy M (2002) Uncemented acetabular components for arthritis after acetabular fracture. Clin Orthop Relat Res (405):164–167
10.
Zurück zum Zitat Biedermann R, Tonin A, Krismer M, Rachbauer F, Eibl G, Stockl B (2005) Reducing the risk of dislocation after total hip arthroplasty: the effect of orientation of the acetabular component. J Bone Jt Surg Br 87(6):762–769CrossRef Biedermann R, Tonin A, Krismer M, Rachbauer F, Eibl G, Stockl B (2005) Reducing the risk of dislocation after total hip arthroplasty: the effect of orientation of the acetabular component. J Bone Jt Surg Br 87(6):762–769CrossRef
11.
Zurück zum Zitat Bjerkholt H, Hovik O, Reikeras O (2010) Direct comparison of polyethylene wear in cemented and uncemented acetabular cups. J Orthop Traumatol 11(3):155–158PubMedCrossRef Bjerkholt H, Hovik O, Reikeras O (2010) Direct comparison of polyethylene wear in cemented and uncemented acetabular cups. J Orthop Traumatol 11(3):155–158PubMedCrossRef
12.
Zurück zum Zitat Bjorgul K, Novicoff WM, Andersen ST, Brevig K, Thu F, Wiig M et al (2010) No differences in outcomes between cemented and uncemented acetabular components after 12–14 years: results from a randomized controlled trial comparing Duraloc with Charnley cups. J Orthop Traumatol 11(1):37–45PubMedCrossRef Bjorgul K, Novicoff WM, Andersen ST, Brevig K, Thu F, Wiig M et al (2010) No differences in outcomes between cemented and uncemented acetabular components after 12–14 years: results from a randomized controlled trial comparing Duraloc with Charnley cups. J Orthop Traumatol 11(1):37–45PubMedCrossRef
13.
Zurück zum Zitat Breusch SJ, Malchau H (2005) The well cemented total hip arthroplasty. Springer, Heidelberg Breusch SJ, Malchau H (2005) The well cemented total hip arthroplasty. Springer, Heidelberg
14.
Zurück zum Zitat Buckwalter AE, Callaghan JJ, Liu SS, Pedersen DR, Goetz DD, Sullivan PM et al (2006) Results of Charnley total hip arthroplasty with use of improved femoral cementing techniques a concise follow-up, at a minimum of twenty-five years, of a previous report. J Bone Jt Surg Am 88(7):1481–1485CrossRef Buckwalter AE, Callaghan JJ, Liu SS, Pedersen DR, Goetz DD, Sullivan PM et al (2006) Results of Charnley total hip arthroplasty with use of improved femoral cementing techniques a concise follow-up, at a minimum of twenty-five years, of a previous report. J Bone Jt Surg Am 88(7):1481–1485CrossRef
15.
Zurück zum Zitat Callaghan JJ, Dysart SH, Savory CG (1988) The uncemented porous-coated anatomic total hip prosthesis. Two-year results of a prospective consecutive series. J Bone Jt Surg Am 70(3):337–346 Callaghan JJ, Dysart SH, Savory CG (1988) The uncemented porous-coated anatomic total hip prosthesis. Two-year results of a prospective consecutive series. J Bone Jt Surg Am 70(3):337–346
16.
Zurück zum Zitat Callaghan JJ, Liu SS, Firestone DE, Yehyawi TM, Goetz DD, Sullivan J et al (2008) Total hip arthroplasty with cement and use of a collared matte-finish femoral component: nineteen to twenty-year follow-up. J Bone Jt Surg Am 90(2):299–306CrossRef Callaghan JJ, Liu SS, Firestone DE, Yehyawi TM, Goetz DD, Sullivan J et al (2008) Total hip arthroplasty with cement and use of a collared matte-finish femoral component: nineteen to twenty-year follow-up. J Bone Jt Surg Am 90(2):299–306CrossRef
17.
Zurück zum Zitat Callanan MC, Jarrett B, Bragdon CR, Zurakowski D, Rubash HE, Freiberg AA et al (2011) The John Charnley Award: risk factors for cup malpositioning: quality improvement through a joint registry at a tertiary hospital. Clin Orthop Relat Res 469(2):319–329PubMedCrossRef Callanan MC, Jarrett B, Bragdon CR, Zurakowski D, Rubash HE, Freiberg AA et al (2011) The John Charnley Award: risk factors for cup malpositioning: quality improvement through a joint registry at a tertiary hospital. Clin Orthop Relat Res 469(2):319–329PubMedCrossRef
18.
Zurück zum Zitat Campbell AC, Rorabeck CH, Bourne RB, Chess D, Nott L (1992) Thigh pain after cementless hip arthroplasty. Annoyance or ill omen. J Bone Jt Surg Br 74(1):63–66 Campbell AC, Rorabeck CH, Bourne RB, Chess D, Nott L (1992) Thigh pain after cementless hip arthroplasty. Annoyance or ill omen. J Bone Jt Surg Br 74(1):63–66
19.
Zurück zum Zitat Chawda M, Hucker P, Whitehouse SL, Crawford RW, English H, Donnelly WJ (2009) Comparison of cemented vs uncemented acetabular component positioning using an imageless navigation system. J Arthroplasty 24(8):1170–1173PubMedCrossRef Chawda M, Hucker P, Whitehouse SL, Crawford RW, English H, Donnelly WJ (2009) Comparison of cemented vs uncemented acetabular component positioning using an imageless navigation system. J Arthroplasty 24(8):1170–1173PubMedCrossRef
20.
Zurück zum Zitat Chen FS, Di Cesare PE, Kale AA, Lee JF, Frankel VH, Stuchin SA et al (1998) Results of cemented metal-backed acetabular components: a 10 year-average follow-up study. J Arthroplasty 13(8):867–873PubMedCrossRef Chen FS, Di Cesare PE, Kale AA, Lee JF, Frankel VH, Stuchin SA et al (1998) Results of cemented metal-backed acetabular components: a 10 year-average follow-up study. J Arthroplasty 13(8):867–873PubMedCrossRef
21.
Zurück zum Zitat Chen PC, Mead EH, Pinto JG, Colwell CW Jr. (1995) Polyethylene wear debris in modular acetabular prostheses. Clin Orthop Relat Res (317):44–56 Chen PC, Mead EH, Pinto JG, Colwell CW Jr. (1995) Polyethylene wear debris in modular acetabular prostheses. Clin Orthop Relat Res (317):44–56
22.
Zurück zum Zitat Chmell MJ, Scott RD, Thomas WH, Sledge CB (1997) Total hip arthroplasty with cement for juvenile rheumatoid arthritis. Results at a minimum of ten years in patients less than thirty years old. J Bone Jt Surg Am 79(1):44–52 Chmell MJ, Scott RD, Thomas WH, Sledge CB (1997) Total hip arthroplasty with cement for juvenile rheumatoid arthritis. Results at a minimum of ten years in patients less than thirty years old. J Bone Jt Surg Am 79(1):44–52
23.
Zurück zum Zitat Chougle A, Hemmady MV, Hodgkinson JP (2005) Severity of hip dysplasia and loosening of the socket in cemented total hip replacement. A long-term follow-up. J Bone Jt Surg Br 87(1):16–20 Chougle A, Hemmady MV, Hodgkinson JP (2005) Severity of hip dysplasia and loosening of the socket in cemented total hip replacement. A long-term follow-up. J Bone Jt Surg Br 87(1):16–20
24.
Zurück zum Zitat Clohisy JC, Harris WH (2001) Matched-pair analysis of cemented and cementless acetabular reconstruction in primary total hip arthroplasty. J Arthroplasty 16(6):697–705PubMedCrossRef Clohisy JC, Harris WH (2001) Matched-pair analysis of cemented and cementless acetabular reconstruction in primary total hip arthroplasty. J Arthroplasty 16(6):697–705PubMedCrossRef
25.
Zurück zum Zitat Cogan A, Nizard R, Sedel L (2011) Occurrence of noise in alumina-on-alumina total hip arthroplasty. A survey on 284 consecutive hips. Orthop Traumatol Surg Res 97:206–210 Cogan A, Nizard R, Sedel L (2011) Occurrence of noise in alumina-on-alumina total hip arthroplasty. A survey on 284 consecutive hips. Orthop Traumatol Surg Res 97:206–210
26.
Zurück zum Zitat Collis DK (1984) Cemented total hip replacement in patients who are less than fifty years old. J Bone Jt Surg Am 66(3):353–359 Collis DK (1984) Cemented total hip replacement in patients who are less than fifty years old. J Bone Jt Surg Am 66(3):353–359
27.
Zurück zum Zitat Conroy JL, Whitehouse SL, Graves SE, Pratt NL, Ryan P, Crawford RW (2008) Risk factors for revision for early dislocation in total hip arthroplasty. J Arthroplasty 23(6):867–872PubMedCrossRef Conroy JL, Whitehouse SL, Graves SE, Pratt NL, Ryan P, Crawford RW (2008) Risk factors for revision for early dislocation in total hip arthroplasty. J Arthroplasty 23(6):867–872PubMedCrossRef
28.
Zurück zum Zitat Corten K, Au K, Bourne RB (2009) Acetabular options: notes from the other side. Orthopedics 32(9):664 Corten K, Au K, Bourne RB (2009) Acetabular options: notes from the other side. Orthopedics 32(9):664
29.
Zurück zum Zitat Corten K, Bourne RB, Charron KD, Au K, Rorabeck CH (2011) What works best, a cemented or cementless primary total hip arthroplasty?: minimum 17 year followup of a randomized controlled trial. Clin Orthop Relat Res 469(1):209–217PubMedCrossRef Corten K, Bourne RB, Charron KD, Au K, Rorabeck CH (2011) What works best, a cemented or cementless primary total hip arthroplasty?: minimum 17 year followup of a randomized controlled trial. Clin Orthop Relat Res 469(1):209–217PubMedCrossRef
30.
Zurück zum Zitat Della Valle CJ, Berger RA, Shott S, Rosenberg AG, Jacobs JJ, Quigley L, Galante JO (2004) Primary total hip arthroplasty with a porous-coated acetabular component. A concise follow-up of a previous report. J Bone Jt Surg Am 86-A(6):1217–1222 Della Valle CJ, Berger RA, Shott S, Rosenberg AG, Jacobs JJ, Quigley L, Galante JO (2004) Primary total hip arthroplasty with a porous-coated acetabular component. A concise follow-up of a previous report. J Bone Jt Surg Am 86-A(6):1217–1222
31.
Zurück zum Zitat Digas G, Kärrholm J, Thanner J, Malchau H, Herberts P (2004) The Otto Aufranc Award. Highly cross-linked polyethylene in total hip arthroplasty: randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis. Clin Orthop Relat Res (429):6–16 Digas G, Kärrholm J, Thanner J, Malchau H, Herberts P (2004) The Otto Aufranc Award. Highly cross-linked polyethylene in total hip arthroplasty: randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis. Clin Orthop Relat Res (429):6–16
32.
Zurück zum Zitat Dodge BM, Fitzrandolph R, Collins DN (1991) Noncemented porous-coated anatomic total hip arthroplasty. Clin Orthop Relat Res (269):16–24 Dodge BM, Fitzrandolph R, Collins DN (1991) Noncemented porous-coated anatomic total hip arthroplasty. Clin Orthop Relat Res (269):16–24
33.
Zurück zum Zitat Dorr LD, Takei GK, Conaty JP (1983) Total hip arthroplastis in patients less than forty-five years old. J Bone Jt Surg Am 65:474–479 Dorr LD, Takei GK, Conaty JP (1983) Total hip arthroplastis in patients less than forty-five years old. J Bone Jt Surg Am 65:474–479
34.
Zurück zum Zitat Duffy GP, Prpa B, Rowland CM, Berry DJ (2004) Primary uncemented Harris-Galante acetabular components in patients 50 years old or younger: results at 10–12 years. Clin Orthop Relat Res (427):157–61 Duffy GP, Prpa B, Rowland CM, Berry DJ (2004) Primary uncemented Harris-Galante acetabular components in patients 50 years old or younger: results at 10–12 years. Clin Orthop Relat Res (427):157–61
35.
Zurück zum Zitat Eskelinen A, Remes V, Helenius I, Pulkkinen P, Nevalainen J, Paavolainen P (2006) Uncemented total hip arthroplasty for primary osteoarthritis in young patients: a mid-to long-term follow-up study from the Finnish Arthroplasty Register. Acta Orthop 77(1):57–70PubMedCrossRef Eskelinen A, Remes V, Helenius I, Pulkkinen P, Nevalainen J, Paavolainen P (2006) Uncemented total hip arthroplasty for primary osteoarthritis in young patients: a mid-to long-term follow-up study from the Finnish Arthroplasty Register. Acta Orthop 77(1):57–70PubMedCrossRef
36.
Zurück zum Zitat Espehaug B, Havelin LI, Engesaeter LB, Vollset SE (1999) The effect of hospital type and operating volume on the survival of hip replacements. A review of 39,505 primary total replacements reported to the Norwegian Arthroplasty Register, 1988–1996. Acta Orthop Scand 70(1):12–18PubMedCrossRef Espehaug B, Havelin LI, Engesaeter LB, Vollset SE (1999) The effect of hospital type and operating volume on the survival of hip replacements. A review of 39,505 primary total replacements reported to the Norwegian Arthroplasty Register, 1988–1996. Acta Orthop Scand 70(1):12–18PubMedCrossRef
37.
Zurück zum Zitat Fehring TK, Smith SE, Braun ER, Mobley C, Wang PL, Griffin WL (1999) Motion at the modular acetabular shell and liner interface. A comparative study. Clin Orthop Relat Res (367):306–314 Fehring TK, Smith SE, Braun ER, Mobley C, Wang PL, Griffin WL (1999) Motion at the modular acetabular shell and liner interface. A comparative study. Clin Orthop Relat Res (367):306–314
38.
Zurück zum Zitat Fevang BT, Lie SA, Havelin LI, Engesaeter LB, Furnes O (2010) Improved results of primary total hip replacement. Acta Orthop 81(6):649–659PubMedCrossRef Fevang BT, Lie SA, Havelin LI, Engesaeter LB, Furnes O (2010) Improved results of primary total hip replacement. Acta Orthop 81(6):649–659PubMedCrossRef
39.
Zurück zum Zitat Flivik G, Sanfridsson J, Onnerfalt R, Kesteris U, Ryd L (2005) Migration of the acetabular component: effect of cement pressurization and significance of early radiolucency: a randomized 5 year using radiostereometry. Acta Orthop 76(2):159–168PubMedCrossRef Flivik G, Sanfridsson J, Onnerfalt R, Kesteris U, Ryd L (2005) Migration of the acetabular component: effect of cement pressurization and significance of early radiolucency: a randomized 5 year using radiostereometry. Acta Orthop 76(2):159–168PubMedCrossRef
40.
Zurück zum Zitat Fowler JL, Gie GA, Lee AJ (1988) Experience with the Exeter total hip replacement since 1970. Orthop Clin North Am 19:477–481PubMed Fowler JL, Gie GA, Lee AJ (1988) Experience with the Exeter total hip replacement since 1970. Orthop Clin North Am 19:477–481PubMed
41.
Zurück zum Zitat Furmanski J, Kraay MJ, Rimnac CM (2011) Crack initiation in retrieved cross-linked highly cross-linked ultrahigh-molecular-weight polyethylene acetabular liners an investigation of 9 cases. J Arthroplasty 26(5):796–801PubMedCrossRef Furmanski J, Kraay MJ, Rimnac CM (2011) Crack initiation in retrieved cross-linked highly cross-linked ultrahigh-molecular-weight polyethylene acetabular liners an investigation of 9 cases. J Arthroplasty 26(5):796–801PubMedCrossRef
42.
Zurück zum Zitat Gaffey JL, Callaghan JJ, Pedersen DR, Goetz DD, Sullivan PM, Johnston RC (2004) Cementless acetabular fixation at fifteen years. A comparison with the same surgeon’s results following acetabular fixation with cement. J Bone Jt Surg Am 86-A(2):257–261 Gaffey JL, Callaghan JJ, Pedersen DR, Goetz DD, Sullivan PM, Johnston RC (2004) Cementless acetabular fixation at fifteen years. A comparison with the same surgeon’s results following acetabular fixation with cement. J Bone Jt Surg Am 86-A(2):257–261
43.
Zurück zum Zitat Garcia-Cimbrelo E, Cruz-Pardos A, Madero R, Ortega-Andreu M (2003) Total hip arthroplasty with use of the cementless Zweymuller Alloclassic system. A ten to thirteen-year follow-up study. J Bone Jt Surg Am 85-A(2):296–303 Garcia-Cimbrelo E, Cruz-Pardos A, Madero R, Ortega-Andreu M (2003) Total hip arthroplasty with use of the cementless Zweymuller Alloclassic system. A ten to thirteen-year follow-up study. J Bone Jt Surg Am 85-A(2):296–303
44.
Zurück zum Zitat Garvin KL, Bowen MK, Salvati EA, Ranawat CS (1991) Long-term results of total hip arthroplasty in congenital dislocation and dysplasia of the hip. A follow-up note. J Bone Jt Surg Am 73(9):1348–1354 Garvin KL, Bowen MK, Salvati EA, Ranawat CS (1991) Long-term results of total hip arthroplasty in congenital dislocation and dysplasia of the hip. A follow-up note. J Bone Jt Surg Am 73(9):1348–1354
45.
Zurück zum Zitat Glyn-Jones S, Isaac S, Hauptfleisch J, Lardy-Smith P, Murray DW, Gill HS (2008) Does highly cross-linked polyethylene wear less than conventional polyethylene in total hip arthroplasty? A double-blind, randomized, and controlled trial using roentgen stereophotogrammetric analysis. J Arthroplasty 23(3):337–343PubMedCrossRef Glyn-Jones S, Isaac S, Hauptfleisch J, Lardy-Smith P, Murray DW, Gill HS (2008) Does highly cross-linked polyethylene wear less than conventional polyethylene in total hip arthroplasty? A double-blind, randomized, and controlled trial using roentgen stereophotogrammetric analysis. J Arthroplasty 23(3):337–343PubMedCrossRef
46.
47.
Zurück zum Zitat Grant P, Grogaard B, Nordsletten L (2004) Ultralok uncemented femoral prostheses: 12–15 year follow-up evaluation. J Arthroplasty 19(3):274–280PubMedCrossRef Grant P, Grogaard B, Nordsletten L (2004) Ultralok uncemented femoral prostheses: 12–15 year follow-up evaluation. J Arthroplasty 19(3):274–280PubMedCrossRef
48.
Zurück zum Zitat Grubl A, Chiari C, Gruber M, Kaider A, Gottsauner-Wolf F (2002) Cementless total hip arthroplasty with a tapered, rectangular titanium stem and a threaded cup: a minimum ten-year follow-up. J Bone Jt Surg Am 84-A(3):425–431 Grubl A, Chiari C, Gruber M, Kaider A, Gottsauner-Wolf F (2002) Cementless total hip arthroplasty with a tapered, rectangular titanium stem and a threaded cup: a minimum ten-year follow-up. J Bone Jt Surg Am 84-A(3):425–431
49.
Zurück zum Zitat Ha YC, Kim SY, Kim HJ, Yoo JJ, Koo KH (2007) Ceramic liner fracture after cementless alumina-on-alumina total hip arthroplasty. Clin Orthop Relat Res 458:106–110PubMed Ha YC, Kim SY, Kim HJ, Yoo JJ, Koo KH (2007) Ceramic liner fracture after cementless alumina-on-alumina total hip arthroplasty. Clin Orthop Relat Res 458:106–110PubMed
50.
Zurück zum Zitat Hailer NP, Garellick G, Karrholm J (2010) Uncemented and cemented primary total hip arthroplasty in the Swedish Hip Arthroplasty Register. Acta Orthop 81(1):34–41PubMedCrossRef Hailer NP, Garellick G, Karrholm J (2010) Uncemented and cemented primary total hip arthroplasty in the Swedish Hip Arthroplasty Register. Acta Orthop 81(1):34–41PubMedCrossRef
51.
Zurück zum Zitat Hallan G, Dybvik E, Furnes O, Havelin LI (2010) Metal-backed acetabular components with conventional polyethylene: a review of 9,113 primary components with a follow-up of 20 years. J Bone Jt Surg Br 92(2):196–201CrossRef Hallan G, Dybvik E, Furnes O, Havelin LI (2010) Metal-backed acetabular components with conventional polyethylene: a review of 9,113 primary components with a follow-up of 20 years. J Bone Jt Surg Br 92(2):196–201CrossRef
52.
Zurück zum Zitat Hallan G, Lie SA, Havelin LI (2006) High wear rates and extensive osteolysis in 3 types of uncemented total hip arthroplasty: a review of the PCA, the Harris Galante and the Profile/Tri-Lock Plus arthroplasties with a minimum of 12 years median follow-up in 96 hips. Acta Orthop 77(4):575–584PubMedCrossRef Hallan G, Lie SA, Havelin LI (2006) High wear rates and extensive osteolysis in 3 types of uncemented total hip arthroplasty: a review of the PCA, the Harris Galante and the Profile/Tri-Lock Plus arthroplasties with a minimum of 12 years median follow-up in 96 hips. Acta Orthop 77(4):575–584PubMedCrossRef
53.
Zurück zum Zitat Hannouche D, Zaoui A, Zadegan F, Sedel L, Nizard R (2011) Thirty years of experience with alumina-on-alumina bearings in total hip arthroplasty. Int Orthop 35(2):207–213PubMedCrossRef Hannouche D, Zaoui A, Zadegan F, Sedel L, Nizard R (2011) Thirty years of experience with alumina-on-alumina bearings in total hip arthroplasty. Int Orthop 35(2):207–213PubMedCrossRef
54.
Zurück zum Zitat Hartofilakidis G, Georgiades G, Babis GC (2009) A comparison of the outcome of cemented all-polyethylene and cementless metal-backed acetabular sockets in primary total hip arthroplasty. J Arthroplasty 24(2):217–225PubMedCrossRef Hartofilakidis G, Georgiades G, Babis GC (2009) A comparison of the outcome of cemented all-polyethylene and cementless metal-backed acetabular sockets in primary total hip arthroplasty. J Arthroplasty 24(2):217–225PubMedCrossRef
55.
Zurück zum Zitat Hasegawa M, Sudo A, Uchida A (2006) Cobalt-chromium head wear following revision hip arthroplasty performed after ceramic fracture—a case report. Acta Orthop 77(5):833–835PubMedCrossRef Hasegawa M, Sudo A, Uchida A (2006) Cobalt-chromium head wear following revision hip arthroplasty performed after ceramic fracture—a case report. Acta Orthop 77(5):833–835PubMedCrossRef
56.
Zurück zum Zitat Havelin LI, Engesaeter LB, Espehaug B, Furnes O, Lie SA, Vollset SE (2000) The Norwegian Arthroplasty Register: 11 years and 73,000 arthroplasties. Acta Orthop Scand 71(4):337–353PubMedCrossRef Havelin LI, Engesaeter LB, Espehaug B, Furnes O, Lie SA, Vollset SE (2000) The Norwegian Arthroplasty Register: 11 years and 73,000 arthroplasties. Acta Orthop Scand 71(4):337–353PubMedCrossRef
57.
Zurück zum Zitat Havelin LI, Espehaug B, Engesaeter LB (2002) The performance of two hydroxyapatite-coated acetabular cups compared with Charnley cups. From the Norwegian Arthroplasty Register. J Bone Jt Surg Br 84(6):839–845CrossRef Havelin LI, Espehaug B, Engesaeter LB (2002) The performance of two hydroxyapatite-coated acetabular cups compared with Charnley cups. From the Norwegian Arthroplasty Register. J Bone Jt Surg Br 84(6):839–845CrossRef
58.
Zurück zum Zitat Havelin LI, Espehaug B, Vollset SE, Engesaeter LB (1994) Early failures among 14,009 cemented and 1,326 uncemented prostheses for primary coxarthrosis. The Norwegian Arthroplasty Register, 1987–1992. Acta Orthop Scand 65(1):1–6PubMedCrossRef Havelin LI, Espehaug B, Vollset SE, Engesaeter LB (1994) Early failures among 14,009 cemented and 1,326 uncemented prostheses for primary coxarthrosis. The Norwegian Arthroplasty Register, 1987–1992. Acta Orthop Scand 65(1):1–6PubMedCrossRef
59.
Zurück zum Zitat Havelin LI, Fenstad AM, Salomonsson R, Mehnert F, Furnes O, Overgaard S et al (2009) The Nordic Arthroplasty Register Association: a unique collaboration between 3 national hip arthroplasty registries with 280,201 THRs. Acta Orthop 80(4):393–401PubMedCrossRef Havelin LI, Fenstad AM, Salomonsson R, Mehnert F, Furnes O, Overgaard S et al (2009) The Nordic Arthroplasty Register Association: a unique collaboration between 3 national hip arthroplasty registries with 280,201 THRs. Acta Orthop 80(4):393–401PubMedCrossRef
60.
Zurück zum Zitat Hearn SL, Bicalho PS, Eng K, Booth RE Jr, Hozack WJ, Rothman RH (1995) Comparison of cemented and cementless total hip arthroplasty in patients with bilateral hip arthroplasties. J Arthroplasty 10(5):603–608PubMedCrossRef Hearn SL, Bicalho PS, Eng K, Booth RE Jr, Hozack WJ, Rothman RH (1995) Comparison of cemented and cementless total hip arthroplasty in patients with bilateral hip arthroplasties. J Arthroplasty 10(5):603–608PubMedCrossRef
61.
Zurück zum Zitat Hernandez JR, Keating EM, Faris PM, Meding JB, Ritter MA (1994) Polyethylene wear in uncemented acetabular components. J Bone Jt Surg Br 76(2):263–266 Hernandez JR, Keating EM, Faris PM, Meding JB, Ritter MA (1994) Polyethylene wear in uncemented acetabular components. J Bone Jt Surg Br 76(2):263–266
62.
Zurück zum Zitat Hooper GJ, Rothwell AG, Stringer M, Frampton C (2009) Revision following cemented and uncemented primary total hip replacement: a seven-year analysis from the New Zealand Joint Registry. J Bone Jt Surg Br 91(4):451–458CrossRef Hooper GJ, Rothwell AG, Stringer M, Frampton C (2009) Revision following cemented and uncemented primary total hip replacement: a seven-year analysis from the New Zealand Joint Registry. J Bone Jt Surg Br 91(4):451–458CrossRef
63.
Zurück zum Zitat Hozack WJ, Rothman RH, Eng K, Mesa J (1996) Primary cementless hip arthroplasty with a titanium plasma sprayed prosthesis. Clin Orthop Relat Res (333):217–225 Hozack WJ, Rothman RH, Eng K, Mesa J (1996) Primary cementless hip arthroplasty with a titanium plasma sprayed prosthesis. Clin Orthop Relat Res (333):217–225
64.
Zurück zum Zitat Huk OL, Bansal M, Betts F, Rimnac CM, Lieberman JR, Huo MH et al (1994) Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components. J Bone Jt Surg Br 76(4):568–574 Huk OL, Bansal M, Betts F, Rimnac CM, Lieberman JR, Huo MH et al (1994) Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components. J Bone Jt Surg Br 76(4):568–574
65.
Zurück zum Zitat Huo MH, Osier CJ (2008) Is cement still a fixation option for total hip arthroplasty? J Arthroplasty 23(7):51–54PubMedCrossRef Huo MH, Osier CJ (2008) Is cement still a fixation option for total hip arthroplasty? J Arthroplasty 23(7):51–54PubMedCrossRef
66.
Zurück zum Zitat Ingram JH, Stone M, Fisher J, Ingham E (2004) The influence of molecular weight, crosslinking and counterface roughness on TNF-alpha production by macrophages in response to ultra high molecular weight polyethylene particles. Biomaterials 25(17):3511–3522PubMedCrossRef Ingram JH, Stone M, Fisher J, Ingham E (2004) The influence of molecular weight, crosslinking and counterface roughness on TNF-alpha production by macrophages in response to ultra high molecular weight polyethylene particles. Biomaterials 25(17):3511–3522PubMedCrossRef
67.
Zurück zum Zitat Kadar T, Hallan G, Aamodt A, Indrekvam K, Badawy M, Skredderstuen A et al (2011) Wear and migration of highly cross-linked and conventional cemented polyethylene cups with cobalt chrome or Oxinium femoral heads: a randomized radiostereometric study of 150 patients. J Orthop Res 29(8):1222–1229PubMedCrossRef Kadar T, Hallan G, Aamodt A, Indrekvam K, Badawy M, Skredderstuen A et al (2011) Wear and migration of highly cross-linked and conventional cemented polyethylene cups with cobalt chrome or Oxinium femoral heads: a randomized radiostereometric study of 150 patients. J Orthop Res 29(8):1222–1229PubMedCrossRef
68.
Zurück zum Zitat Kavanagh BF, Dewitz MA, Ilstrup DM, Stauffer RN, Coventry MB (1989) Charnley total hip arthroplasty with cement. Fifteen-year results. J Bone Jt Surg Am 71(10):1496–1503 Kavanagh BF, Dewitz MA, Ilstrup DM, Stauffer RN, Coventry MB (1989) Charnley total hip arthroplasty with cement. Fifteen-year results. J Bone Jt Surg Am 71(10):1496–1503
69.
Zurück zum Zitat Kawamura H, Dunbar MJ, Murray P, Bourne RB, Rorabeck CH (2001) The porous coated anatomic total hip replacement. A ten to fourteen-year follow-up study of a cementless total hip arthroplasty. J Bone Jt Surg Am 83A(9):1333–1338 Kawamura H, Dunbar MJ, Murray P, Bourne RB, Rorabeck CH (2001) The porous coated anatomic total hip replacement. A ten to fourteen-year follow-up study of a cementless total hip arthroplasty. J Bone Jt Surg Am 83A(9):1333–1338
70.
Zurück zum Zitat Kim YH, Kim JS, Cho SH (1999) Primary total hip arthroplasty with a cementless porous-coated anatomic total hip prosthesis: 10–12 year results of prospective and consecutive series. J Arthroplasty 14(5):538–548PubMedCrossRef Kim YH, Kim JS, Cho SH (1999) Primary total hip arthroplasty with a cementless porous-coated anatomic total hip prosthesis: 10–12 year results of prospective and consecutive series. J Arthroplasty 14(5):538–548PubMedCrossRef
71.
Zurück zum Zitat Kim YH, Kook HK, Kim JS (2002) Total hip replacement with a cementless acetabular component and a cemented femoral component in patients younger than fifty years of age. J Bone Jt Surg Am 84-A(5):770–774 Kim YH, Kook HK, Kim JS (2002) Total hip replacement with a cementless acetabular component and a cemented femoral component in patients younger than fifty years of age. J Bone Jt Surg Am 84-A(5):770–774
72.
Zurück zum Zitat Kim YH, Oh SH, Kim JS, Koo KH (2003) Contemporary total hip arthroplasty with and without cement in patients with osteonecrosis of the femoral head. J Bone Jt Surg Am 85-A(4):675–681 Kim YH, Oh SH, Kim JS, Koo KH (2003) Contemporary total hip arthroplasty with and without cement in patients with osteonecrosis of the femoral head. J Bone Jt Surg Am 85-A(4):675–681
73.
Zurück zum Zitat Kobayashi S, Terayama K (1993) Factors influencing survival of the socket after primary low-friction arthroplasty of the hip. Arch Orthop Trauma Surg 112(2):56–60PubMedCrossRef Kobayashi S, Terayama K (1993) Factors influencing survival of the socket after primary low-friction arthroplasty of the hip. Arch Orthop Trauma Surg 112(2):56–60PubMedCrossRef
74.
Zurück zum Zitat Kotwal RS, Ganapathi M, John A, Maheson M, Jones SA (2009) Outcome of treatment for dislocation after primary total hip replacement. J Bone Jt Surg Br 91(3):321–326CrossRef Kotwal RS, Ganapathi M, John A, Maheson M, Jones SA (2009) Outcome of treatment for dislocation after primary total hip replacement. J Bone Jt Surg Br 91(3):321–326CrossRef
75.
Zurück zum Zitat Krismer M, Fischer M, Klestil T, Frischhut B (1991) Uncoated polyethylene RM acetabular component versus Muller cemented acetabular component. A 4–8 year follow-up study. Arch Orthop Trauma Surg 110(4):195–199PubMedCrossRef Krismer M, Fischer M, Klestil T, Frischhut B (1991) Uncoated polyethylene RM acetabular component versus Muller cemented acetabular component. A 4–8 year follow-up study. Arch Orthop Trauma Surg 110(4):195–199PubMedCrossRef
76.
Zurück zum Zitat Kubo T, Inoue S, Maeda T, Arai Y, Hirakawa K, Wu Y et al (2001) Cementless Lord total hip arthroplasty: cup loosening common after minimum 10 year follow-up of 103 hips. Acta Orthop Scand 72(6):585–590PubMedCrossRef Kubo T, Inoue S, Maeda T, Arai Y, Hirakawa K, Wu Y et al (2001) Cementless Lord total hip arthroplasty: cup loosening common after minimum 10 year follow-up of 103 hips. Acta Orthop Scand 72(6):585–590PubMedCrossRef
77.
Zurück zum Zitat Kurtz SM, Gawel HA, Patel JD (2011) History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene. Clin Orthop Relat Res 469(8):2262–2277PubMedCrossRef Kurtz SM, Gawel HA, Patel JD (2011) History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene. Clin Orthop Relat Res 469(8):2262–2277PubMedCrossRef
78.
Zurück zum Zitat Kurtz SM, Ochoa JA, White CV, Srivastav S, Cournoyer J (1998) Backside nonconformity and locking restraints affect liner/shell load transfer mechanisms and relative motion in modular acetabular components for total hip replacement. J Biomech 31(5):431–437PubMedCrossRef Kurtz SM, Ochoa JA, White CV, Srivastav S, Cournoyer J (1998) Backside nonconformity and locking restraints affect liner/shell load transfer mechanisms and relative motion in modular acetabular components for total hip replacement. J Biomech 31(5):431–437PubMedCrossRef
79.
Zurück zum Zitat la Valle CJ, Berger RA, Shott S, Rosenberg AG, Jacobs JJ, Quigley L et al (2004) Primary total hip arthroplasty with a porous-coated acetabular component. A concise follow-up of a previous report. J Bone Jt Surg Am 86-A(6):1217–1222 la Valle CJ, Berger RA, Shott S, Rosenberg AG, Jacobs JJ, Quigley L et al (2004) Primary total hip arthroplasty with a porous-coated acetabular component. A concise follow-up of a previous report. J Bone Jt Surg Am 86-A(6):1217–1222
80.
Zurück zum Zitat Labek G, Thaler M, Janda W, Agreiter M, Stockl B (2011) Revision rates after total joint replacement: cumulative results from worldwide joint register datasets. J Bone Jt Surg Br 93(3):293–297CrossRef Labek G, Thaler M, Janda W, Agreiter M, Stockl B (2011) Revision rates after total joint replacement: cumulative results from worldwide joint register datasets. J Bone Jt Surg Br 93(3):293–297CrossRef
81.
Zurück zum Zitat Lachiewicz PF, Heckman DS, Soileau ES, Mangla J, Martell JM (2009) Femoral head size and wear of highly cross-linked polyethylene at 5–8 years. Clin Orthop Relat Res 467(12):3290–3296PubMedCrossRef Lachiewicz PF, Heckman DS, Soileau ES, Mangla J, Martell JM (2009) Femoral head size and wear of highly cross-linked polyethylene at 5–8 years. Clin Orthop Relat Res 467(12):3290–3296PubMedCrossRef
82.
Zurück zum Zitat Laupacis A, Bourne R, Rorabeck C, Feeny D, Tugwell P, Wong C (2002) Comparison of total hip arthroplasty performed with and without cement: a randomized trial. J Bone Jt Surg Am 84A(10):1823–1828 Laupacis A, Bourne R, Rorabeck C, Feeny D, Tugwell P, Wong C (2002) Comparison of total hip arthroplasty performed with and without cement: a randomized trial. J Bone Jt Surg Am 84A(10):1823–1828
83.
Zurück zum Zitat Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR (1978) Dislocations after total hip-replacement arthroplasties. J Bone Jt Surg Am 60(2):217–220 Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR (1978) Dislocations after total hip-replacement arthroplasties. J Bone Jt Surg Am 60(2):217–220
84.
Zurück zum Zitat Lie SA, Hallan G, Furnes O, Havelin LI, Engesaeter LB (2007) Isolated acetabular liner exchange compared with complete acetabular component revision in revision of primary uncemented acetabular components: a study of 1649 revisions from the Norwegian Arthroplasty Register. J Bone Jt Surg Br 89(5):591–594CrossRef Lie SA, Hallan G, Furnes O, Havelin LI, Engesaeter LB (2007) Isolated acetabular liner exchange compared with complete acetabular component revision in revision of primary uncemented acetabular components: a study of 1649 revisions from the Norwegian Arthroplasty Register. J Bone Jt Surg Br 89(5):591–594CrossRef
85.
86.
Zurück zum Zitat MacKenzie JR, Kelley SS, Johnston RC (1996) Total hip replacement for coxarthrosis secondary to congenital dysplasia and dislocation of the hip. Long-term results. J Bone Jt Surg Am 78(1):55–61 MacKenzie JR, Kelley SS, Johnston RC (1996) Total hip replacement for coxarthrosis secondary to congenital dysplasia and dislocation of the hip. Long-term results. J Bone Jt Surg Am 78(1):55–61
87.
Zurück zum Zitat Mai K, Verioti C, Ezzet KA, Copp SN, Walker RH, Colwell CW Jr (2010) Incidence of ‘squeaking’ after ceramic-on-ceramic total hip arthroplasty. Clin Orthop Relat Res 468(2):413–417PubMedCrossRef Mai K, Verioti C, Ezzet KA, Copp SN, Walker RH, Colwell CW Jr (2010) Incidence of ‘squeaking’ after ceramic-on-ceramic total hip arthroplasty. Clin Orthop Relat Res 468(2):413–417PubMedCrossRef
88.
Zurück zum Zitat Makela KT, Eskelinen A, Pulkkinen P, Paavolainen P, Remes V (2008) Total hip arthroplasty for primary osteoarthritis in patients fifty-five years of age or older. An analysis of the Finnish arthroplasty registry. J Bone Jt Surg Am 90(10):2160–2170CrossRef Makela KT, Eskelinen A, Pulkkinen P, Paavolainen P, Remes V (2008) Total hip arthroplasty for primary osteoarthritis in patients fifty-five years of age or older. An analysis of the Finnish arthroplasty registry. J Bone Jt Surg Am 90(10):2160–2170CrossRef
89.
Zurück zum Zitat Makela KT, Eskelinen A, Pulkkinen P, Virolainen P, Paavolainen P, Remes V (2011) Cemented versus cementless total hip replacements in patients fifty-five years of age or older with rheumatoid arthritis. J Bone Jt Surg Am 93(2):178–186CrossRef Makela KT, Eskelinen A, Pulkkinen P, Virolainen P, Paavolainen P, Remes V (2011) Cemented versus cementless total hip replacements in patients fifty-five years of age or older with rheumatoid arthritis. J Bone Jt Surg Am 93(2):178–186CrossRef
90.
Zurück zum Zitat Mall NA, Nunley RM, Zhu JJ, Maloney WJ, Barrack RL, Clohisy JC (2011) The incidence of acetabular osteolysis in young patients with conventional versus highly crosslinked polyethylene. Clin Orthop Relat Res 469(2):372–381PubMedCrossRef Mall NA, Nunley RM, Zhu JJ, Maloney WJ, Barrack RL, Clohisy JC (2011) The incidence of acetabular osteolysis in young patients with conventional versus highly crosslinked polyethylene. Clin Orthop Relat Res 469(2):372–381PubMedCrossRef
91.
Zurück zum Zitat Mallory TH, Lombardi AV Jr, Leith JR, Fujita H, Hartman JF, Capps SG et al (2001) Minimal 10 year results of a tapered cementless femoral component in total hip arthroplasty. J Arthroplasty 16(8 Suppl 1):49–54PubMedCrossRef Mallory TH, Lombardi AV Jr, Leith JR, Fujita H, Hartman JF, Capps SG et al (2001) Minimal 10 year results of a tapered cementless femoral component in total hip arthroplasty. J Arthroplasty 16(8 Suppl 1):49–54PubMedCrossRef
92.
Zurück zum Zitat McCalden RW, MacDonald SJ, Rorabeck CH, Bourne RB, Chess DG, Charron KD (2009) Wear rate of highly cross-linked polyethylene in total hip arthroplasty. A randomized controlled trial. J Bone Jt Surg Am 91(4):773–782CrossRef McCalden RW, MacDonald SJ, Rorabeck CH, Bourne RB, Chess DG, Charron KD (2009) Wear rate of highly cross-linked polyethylene in total hip arthroplasty. A randomized controlled trial. J Bone Jt Surg Am 91(4):773–782CrossRef
93.
Zurück zum Zitat McCombe P, Williams SA (2004) A comparison of polyethylene wear rates between cemented and cementless cups. A prospective, randomised trial. J Bone Jt Surg Br 86(3):344–349CrossRef McCombe P, Williams SA (2004) A comparison of polyethylene wear rates between cemented and cementless cups. A prospective, randomised trial. J Bone Jt Surg Br 86(3):344–349CrossRef
94.
Zurück zum Zitat McCoy TH, Salvati EA, Ranawat CS, Wilson PD Jr (1988) A fifteen-year follow-up study of one hundred Charnley low-friction arthroplasties. Orthop Clin North Am 19(3):467–476PubMed McCoy TH, Salvati EA, Ranawat CS, Wilson PD Jr (1988) A fifteen-year follow-up study of one hundred Charnley low-friction arthroplasties. Orthop Clin North Am 19(3):467–476PubMed
95.
Zurück zum Zitat McCullough CJ, Remedios D, Tytherleigh-Strong G, Hua J, Walker PS (2006) The use of hydroxyapatite-coated CAD-CAM femoral components in adolescents and young adults with inflammatory polyarthropathy: ten-year results. J Bone Jt Surg Br 88(7):860–864CrossRef McCullough CJ, Remedios D, Tytherleigh-Strong G, Hua J, Walker PS (2006) The use of hydroxyapatite-coated CAD-CAM femoral components in adolescents and young adults with inflammatory polyarthropathy: ten-year results. J Bone Jt Surg Br 88(7):860–864CrossRef
96.
Zurück zum Zitat McLaughlin JR, Lee KR (2008) Total hip arthroplasty with an uncemented tapered femoral component. J Bone Jt Surg Am 90(6):1290–1296CrossRef McLaughlin JR, Lee KR (2008) Total hip arthroplasty with an uncemented tapered femoral component. J Bone Jt Surg Am 90(6):1290–1296CrossRef
97.
Zurück zum Zitat Mesko JW, D’Antonio JA, Capello WN, Bierbaum BE, Naughton M (2011) Ceramic-on-ceramic hip outcome at a 5–10 year interval: has it lived up to its expectations? J Arthroplasty 26(2):172–177PubMedCrossRef Mesko JW, D’Antonio JA, Capello WN, Bierbaum BE, Naughton M (2011) Ceramic-on-ceramic hip outcome at a 5–10 year interval: has it lived up to its expectations? J Arthroplasty 26(2):172–177PubMedCrossRef
98.
Zurück zum Zitat Mjoberg B, Brismar J, Hansson LI, Pettersson H, Selvik G, Onnerfalt R (1985) Definition of endoprosthetic loosening. Comparison of arthrography, scintigraphy and roentgen stereophotogrammetry in prosthetic hips. Acta Orthop Scand 56(6):469–473PubMedCrossRef Mjoberg B, Brismar J, Hansson LI, Pettersson H, Selvik G, Onnerfalt R (1985) Definition of endoprosthetic loosening. Comparison of arthrography, scintigraphy and roentgen stereophotogrammetry in prosthetic hips. Acta Orthop Scand 56(6):469–473PubMedCrossRef
99.
Zurück zum Zitat Moher D, Cook DJ, Eastwood S, Olkin I, Rennie D, Stroup DF (1999) Improving the quality of reports of meta-analyses of randomised controlled trials: the QUOROM statement. Quality of reporting of meta-analyses. Lancet 354(9193):1896–1900PubMedCrossRef Moher D, Cook DJ, Eastwood S, Olkin I, Rennie D, Stroup DF (1999) Improving the quality of reports of meta-analyses of randomised controlled trials: the QUOROM statement. Quality of reporting of meta-analyses. Lancet 354(9193):1896–1900PubMedCrossRef
100.
Zurück zum Zitat Morshed S, Bozic KJ, Ries MD, Malchau H, Colford JM Jr (2007) Comparison of cemented and uncemented fixation in total hip replacement: a meta-analysis. Acta Orthop 78(3):315–326PubMedCrossRef Morshed S, Bozic KJ, Ries MD, Malchau H, Colford JM Jr (2007) Comparison of cemented and uncemented fixation in total hip replacement: a meta-analysis. Acta Orthop 78(3):315–326PubMedCrossRef
101.
Zurück zum Zitat Mulliken BD, Rorabeck CH, Bourne RB (1996) Uncemented revision total hip arthroplasty: a 4–6 year review. Clin Orthop Relat Res (325):156–162 Mulliken BD, Rorabeck CH, Bourne RB (1996) Uncemented revision total hip arthroplasty: a 4–6 year review. Clin Orthop Relat Res (325):156–162
102.
Zurück zum Zitat Mutimer J, Devane PA, Adams K, Horne JG (2010) Highly crosslinked polyethylene reduces wear in total hip arthroplasty at 5 years. Clin Orthop Relat Res 468(12):3228–3233PubMedCrossRef Mutimer J, Devane PA, Adams K, Horne JG (2010) Highly crosslinked polyethylene reduces wear in total hip arthroplasty at 5 years. Clin Orthop Relat Res 468(12):3228–3233PubMedCrossRef
103.
Zurück zum Zitat Nashed RS, Becker DA, Gustilo RB (1995) Are cementless acetabular components the cause of excess wear and osteolysis in total hip arthroplasty? Clin Orthop Relat Res (317):19–28 Nashed RS, Becker DA, Gustilo RB (1995) Are cementless acetabular components the cause of excess wear and osteolysis in total hip arthroplasty? Clin Orthop Relat Res (317):19–28
104.
Zurück zum Zitat Nercessian O, Martin G, Joshi RP, Su BW, Eftekhar NS (2005) A 15–25 year follow-up study of primary Charnley low-friction arthroplasty. J Arthroplasty 20(2):162–167PubMedCrossRef Nercessian O, Martin G, Joshi RP, Su BW, Eftekhar NS (2005) A 15–25 year follow-up study of primary Charnley low-friction arthroplasty. J Arthroplasty 20(2):162–167PubMedCrossRef
108.
Zurück zum Zitat Onsten I, Carlsson AS, Besjakov J (1998) Wear in uncemented porous and cemented polyethylene sockets: a randomised, radiostereometric study. J Bone Jt Surg Br 80(2):345–350CrossRef Onsten I, Carlsson AS, Besjakov J (1998) Wear in uncemented porous and cemented polyethylene sockets: a randomised, radiostereometric study. J Bone Jt Surg Br 80(2):345–350CrossRef
109.
Zurück zum Zitat Paavilainen T, Hoikka V, Paavolainen P (1993) Cementless total hip arthroplasty for congenitally dislocated or dysplastic hips. Technique for replacement with a straight femoral component. Clin Orthop Relat Res (297):71–81 Paavilainen T, Hoikka V, Paavolainen P (1993) Cementless total hip arthroplasty for congenitally dislocated or dysplastic hips. Technique for replacement with a straight femoral component. Clin Orthop Relat Res (297):71–81
110.
Zurück zum Zitat Pakvis D, van Hellemondt G, de Visser E, Jacobs W, Spruit M (2011) Is there evidence for a superior method of socket fixation in hip arthroplasty? A systematic review. Int Orthop 35(8):1109–1118 Pakvis D, van Hellemondt G, de Visser E, Jacobs W, Spruit M (2011) Is there evidence for a superior method of socket fixation in hip arthroplasty? A systematic review. Int Orthop 35(8):1109–1118
111.
Zurück zum Zitat Petsatodis GE, Papadopoulos PP, Papavasiliou KA, Hatzokos IG, Agathangelidis FG, Christodoulou AG (2010) Primary cementless total hip arthroplasty with an alumina ceramic-on-ceramic bearing: results after a minimum of twenty years of follow-up. J Bone Jt Surg Am 92(3):639–644CrossRef Petsatodis GE, Papadopoulos PP, Papavasiliou KA, Hatzokos IG, Agathangelidis FG, Christodoulou AG (2010) Primary cementless total hip arthroplasty with an alumina ceramic-on-ceramic bearing: results after a minimum of twenty years of follow-up. J Bone Jt Surg Am 92(3):639–644CrossRef
112.
Zurück zum Zitat Philippot R, Adam P, Reckhaus M, Delangle F, Verdot FX, Curvale G et al (2009) Prevention of dislocation in total hip revision surgery using a dual mobility design. Orthop Traumatol Surg Res 95(6):407–413PubMedCrossRef Philippot R, Adam P, Reckhaus M, Delangle F, Verdot FX, Curvale G et al (2009) Prevention of dislocation in total hip revision surgery using a dual mobility design. Orthop Traumatol Surg Res 95(6):407–413PubMedCrossRef
113.
Zurück zum Zitat Pospischill M, Knahr K (2005) Cementless total hip arthroplasty using a threaded cup and a rectangular tapered stem: follow-up for ten to 17 years. J Bone Jt Surg Br 87-B:1210–1215CrossRef Pospischill M, Knahr K (2005) Cementless total hip arthroplasty using a threaded cup and a rectangular tapered stem: follow-up for ten to 17 years. J Bone Jt Surg Br 87-B:1210–1215CrossRef
114.
Zurück zum Zitat Pospula W, Abu Noor T, Roshdy T, Al Mukaimi A (2008) Cemented and cementless total hip replacement. Critical analysis and comparison of clinical and radiological results of 182 cases operated in Al Razi Hospital, Kuwait. Med Princ Pract 17(3):239–243 Pospula W, Abu Noor T, Roshdy T, Al Mukaimi A (2008) Cemented and cementless total hip replacement. Critical analysis and comparison of clinical and radiological results of 182 cases operated in Al Razi Hospital, Kuwait. Med Princ Pract 17(3):239–243
115.
Zurück zum Zitat Powers CC, Ho H, Beykirch SE, Huynh C, Hopper RH Jr, Engh CA Jr et al (2010) A comparison of a second- and a third-generation modular cup design: is new improved? J Arthroplasty 25(4):514–521PubMedCrossRef Powers CC, Ho H, Beykirch SE, Huynh C, Hopper RH Jr, Engh CA Jr et al (2010) A comparison of a second- and a third-generation modular cup design: is new improved? J Arthroplasty 25(4):514–521PubMedCrossRef
116.
Zurück zum Zitat Ranawat CS, Rawlins BA, Harju VT (1988) Effect of modern cement technique on acetabular fixation total hip arthroplasty. A retrospective study in matched pairs. Orthop Clin North Am 19(3):599–603PubMed Ranawat CS, Rawlins BA, Harju VT (1988) Effect of modern cement technique on acetabular fixation total hip arthroplasty. A retrospective study in matched pairs. Orthop Clin North Am 19(3):599–603PubMed
117.
Zurück zum Zitat Reigstad O, Siewers P, Rokkum M, Espehaug B (2008) Excellent long-term survival of an uncemented press-fit stem and screw cup in young patients: follow-up of 75 hips for 15–18 years. Acta Orthop 79(2):194–202PubMedCrossRef Reigstad O, Siewers P, Rokkum M, Espehaug B (2008) Excellent long-term survival of an uncemented press-fit stem and screw cup in young patients: follow-up of 75 hips for 15–18 years. Acta Orthop 79(2):194–202PubMedCrossRef
119.
Zurück zum Zitat Riska EB (1993) Ceramic endoprosthesis in total hip arthroplasty. Clin Orthop Relat Res (297):87–94 Riska EB (1993) Ceramic endoprosthesis in total hip arthroplasty. Clin Orthop Relat Res (297):87–94
120.
Zurück zum Zitat Ritter MA, Thong AE (2004) The role of cemented sockets in 2004: is there one? J Arthroplasty 19(4 Suppl 1):92–94PubMedCrossRef Ritter MA, Thong AE (2004) The role of cemented sockets in 2004: is there one? J Arthroplasty 19(4 Suppl 1):92–94PubMedCrossRef
121.
Zurück zum Zitat Rorabeck CH, Bourne RB, Mulliken BD, Nayak N, Laupacis A, Tugwell P, et al (1996) The Nicolas Andry award: comparative results of cemented and cementless total hip arthroplasty. Clin Orthop Relat Res (325):330–344 Rorabeck CH, Bourne RB, Mulliken BD, Nayak N, Laupacis A, Tugwell P, et al (1996) The Nicolas Andry award: comparative results of cemented and cementless total hip arthroplasty. Clin Orthop Relat Res (325):330–344
122.
Zurück zum Zitat Rothman RH, Cohn JC (1990) Cemented versus cementless total hip arthroplasty. A critical review. Clin Orthop Relat Res (254):153–169 Rothman RH, Cohn JC (1990) Cemented versus cementless total hip arthroplasty. A critical review. Clin Orthop Relat Res (254):153–169
123.
Zurück zum Zitat Saito S, Ishii T, Mori S, Hosaka K, Nemoto N, Tokuhashi Y (2011) Long-term results of bulk femoral head autograft in cementless THA for developmental hip dysplasia. Orthopedics 34(2):88PubMed Saito S, Ishii T, Mori S, Hosaka K, Nemoto N, Tokuhashi Y (2011) Long-term results of bulk femoral head autograft in cementless THA for developmental hip dysplasia. Orthopedics 34(2):88PubMed
124.
Zurück zum Zitat Schmalzried TP, Shepherd EF, Dorey FJ (2000) Wear is a function of use not time. Clin Orthop Relat Res 381:36–46PubMedCrossRef Schmalzried TP, Shepherd EF, Dorey FJ (2000) Wear is a function of use not time. Clin Orthop Relat Res 381:36–46PubMedCrossRef
125.
Zurück zum Zitat Schroder DT, Kelly NH, Wright TM, Parks ML (2011) Retrieved highly crosslinked UHMWPE acetabular liners have similar wear damage as conventional UHMWPE. Clin Orthop Relat Res 469(2):387–394PubMedCrossRef Schroder DT, Kelly NH, Wright TM, Parks ML (2011) Retrieved highly crosslinked UHMWPE acetabular liners have similar wear damage as conventional UHMWPE. Clin Orthop Relat Res 469(2):387–394PubMedCrossRef
126.
Zurück zum Zitat Sinha RK, Dungy DS, Yeon HB (2004) Primary total hip arthroplasty with a proximally porous-coated femoral stem. J Bone Jt Surg Am 86-A(6):1254–1261 Sinha RK, Dungy DS, Yeon HB (2004) Primary total hip arthroplasty with a proximally porous-coated femoral stem. J Bone Jt Surg Am 86-A(6):1254–1261
127.
Zurück zum Zitat Skutek M, Bourne RB, Rorabeck CH, Burns A, Kearns S, Krishna G (2007) The twenty to twenty-five-year outcomes of the Harris design-2 matte-finished cemented total hip replacement. A concise follow-up of a previous report. J Bone Jt Surg Am 89(4):814–818CrossRef Skutek M, Bourne RB, Rorabeck CH, Burns A, Kearns S, Krishna G (2007) The twenty to twenty-five-year outcomes of the Harris design-2 matte-finished cemented total hip replacement. A concise follow-up of a previous report. J Bone Jt Surg Am 89(4):814–818CrossRef
128.
Zurück zum Zitat Sochart DH, Porter ML (1997) The long-term results of Charnley low-friction arthroplasty in young patients who have congenital dislocation, degenerative osteoarthrosis, or rheumatoid arthritis. J Bone Jt Surg Am 79(11):1599–1617 Sochart DH, Porter ML (1997) The long-term results of Charnley low-friction arthroplasty in young patients who have congenital dislocation, degenerative osteoarthrosis, or rheumatoid arthritis. J Bone Jt Surg Am 79(11):1599–1617
129.
Zurück zum Zitat Sochart DH, Porter ML (1998) Long-term results of cemented Charnley low-friction arthroplasty in patients aged less than 30 years. J Arthroplasty 13(2):123–131PubMedCrossRef Sochart DH, Porter ML (1998) Long-term results of cemented Charnley low-friction arthroplasty in patients aged less than 30 years. J Arthroplasty 13(2):123–131PubMedCrossRef
130.
Zurück zum Zitat Stanat SJ, Capozzi JD (2011) Squeaking in Third- and fourth-generation ceramic-on-ceramic total hip arthroplasty meta-analysis and systematic review. J Arthroplasty [Epub ahead of print] Stanat SJ, Capozzi JD (2011) Squeaking in Third- and fourth-generation ceramic-on-ceramic total hip arthroplasty meta-analysis and systematic review. J Arthroplasty [Epub ahead of print]
131.
Zurück zum Zitat Suckel A, Geiger F, Kinzl L, Wulker N, Garbrecht M (2009) Long-term results for the uncemented Zweymuller/Alloclassic hip endoprosthesis. A 15 year minimum follow-up of 320 hip operations. J Arthroplasty 24(6):846–853PubMedCrossRef Suckel A, Geiger F, Kinzl L, Wulker N, Garbrecht M (2009) Long-term results for the uncemented Zweymuller/Alloclassic hip endoprosthesis. A 15 year minimum follow-up of 320 hip operations. J Arthroplasty 24(6):846–853PubMedCrossRef
132.
Zurück zum Zitat Sutherland CJ, Wilde AH, Borden LS, Marks KE (1982) A ten-year follow-up of one hundred consecutive Muller curved-stem total hip replacement arthroplasties. J Bone Jt Surg Am 64:970–982 Sutherland CJ, Wilde AH, Borden LS, Marks KE (1982) A ten-year follow-up of one hundred consecutive Muller curved-stem total hip replacement arthroplasties. J Bone Jt Surg Am 64:970–982
133.
Zurück zum Zitat Torchia ME, Klassen RA, Bianco AJ (1996) Total hip arthroplasty with cement in patients less than twenty years old. Long-term results. J Bone Jt Surg Am 78(7):995–1003 Torchia ME, Klassen RA, Bianco AJ (1996) Total hip arthroplasty with cement in patients less than twenty years old. Long-term results. J Bone Jt Surg Am 78(7):995–1003
134.
Zurück zum Zitat Tower SS, Currier JH, Currier BH, Lyford KA, Van Citters DW, Mayor MB (2007) Rim cracking of the cross-linked longevity polyethylene acetabular liner after total hip arthroplasty. J Bone Jt Surg Am 89(10):2212–2217CrossRef Tower SS, Currier JH, Currier BH, Lyford KA, Van Citters DW, Mayor MB (2007) Rim cracking of the cross-linked longevity polyethylene acetabular liner after total hip arthroplasty. J Bone Jt Surg Am 89(10):2212–2217CrossRef
135.
Zurück zum Zitat Udomkiat P, Dorr LD, Wan Z (2002) Cementless hemispheric porous-coated sockets implanted with press-fit technique without screws: average ten-year follow-up. J Bone Jt Surg Am 84-A(7):1195–1200 Udomkiat P, Dorr LD, Wan Z (2002) Cementless hemispheric porous-coated sockets implanted with press-fit technique without screws: average ten-year follow-up. J Bone Jt Surg Am 84-A(7):1195–1200
136.
Zurück zum Zitat Utting MR, Raghuvanshi M, Amirfeyz R, Blom AW, Learmonth ID, Bannister GC (2008) The Harris-Galante porous-coated, hemispherical, polyethylene-lined acetabular component in patients under 50 years of age: a 12–16 year review. J Bone Jt Surg Br 90(11):1422–1427CrossRef Utting MR, Raghuvanshi M, Amirfeyz R, Blom AW, Learmonth ID, Bannister GC (2008) The Harris-Galante porous-coated, hemispherical, polyethylene-lined acetabular component in patients under 50 years of age: a 12–16 year review. J Bone Jt Surg Br 90(11):1422–1427CrossRef
137.
Zurück zum Zitat Veitch SW, Whitehouse SL, Howell JR, Hubble MJ, Gie GA, Timperley AJ (2010) The concentric all-polyethylene Exeter acetabular component in primary total hip replacement. J Bone Jt Surg Br 92(10):1351–1355CrossRef Veitch SW, Whitehouse SL, Howell JR, Hubble MJ, Gie GA, Timperley AJ (2010) The concentric all-polyethylene Exeter acetabular component in primary total hip replacement. J Bone Jt Surg Br 92(10):1351–1355CrossRef
138.
Zurück zum Zitat Volkmann R, Schneider MA, Bretschneider C, Weise K (1999) More failures of uncemented acetabular screw-rings than of cemented polyethylene cups in total hip arthroplasties. Int Orthop 23(3):138–139PubMedCrossRef Volkmann R, Schneider MA, Bretschneider C, Weise K (1999) More failures of uncemented acetabular screw-rings than of cemented polyethylene cups in total hip arthroplasties. Int Orthop 23(3):138–139PubMedCrossRef
139.
Zurück zum Zitat Wangen H, Lereim P, Holm I, Gunderson R, Reikeras O (2008) Hip arthroplasty in patients younger than 30 years: excellent ten to 16 year follow-up results with a HA-coated stem. Int Orthop 32(2):203–208PubMedCrossRef Wangen H, Lereim P, Holm I, Gunderson R, Reikeras O (2008) Hip arthroplasty in patients younger than 30 years: excellent ten to 16 year follow-up results with a HA-coated stem. Int Orthop 32(2):203–208PubMedCrossRef
140.
Zurück zum Zitat Weber M, Berry DJ, Harmsen WS (1998) Total hip arthroplasty after operative treatment of an acetabular fracture. J Bone Jt Surg Am 80(9):1295–1305 Weber M, Berry DJ, Harmsen WS (1998) Total hip arthroplasty after operative treatment of an acetabular fracture. J Bone Jt Surg Am 80(9):1295–1305
141.
Zurück zum Zitat Zicat B, Engh CA, Gokcen E (1995) Patterns of osteolysis around total hip components inserted with and without cement. J Bone Jt Surg Am 77(3):432–439 Zicat B, Engh CA, Gokcen E (1995) Patterns of osteolysis around total hip components inserted with and without cement. J Bone Jt Surg Am 77(3):432–439
Metadaten
Titel
Total hip arthroplasty: to cement or not to cement the acetabular socket? A critical review of the literature
verfasst von
N. D. Clement
L. C. Biant
S. J. Breusch
Publikationsdatum
01.03.2012
Verlag
Springer-Verlag
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 3/2012
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-011-1422-2

Weitere Artikel der Ausgabe 3/2012

Archives of Orthopaedic and Trauma Surgery 3/2012 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.