Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 9/2013

01.09.2013 | Arthroscopy and Sports Medicine

Impact of tendon suturing on the interference fixation strength of quadrupled hamstring tendon grafts

verfasst von: Jürgen Höher, Christoph Offerhaus, Eric Steenlage, Andreas Weiler, Sven Scheffler

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 9/2013

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Interference screw fixation of soft tissue grafts has been a widely used fixation technique for cruciate ligament reconstruction. Suturing of the graft construct prior to graft fixation has been proposed to increase fixation strength; however, the effect on mechanical properties has not been well characterized. The goal of this study was to determine whether uniform suturing of the tendon graft affects (1) ultimate fixation strength of the hamstring tendon graft and (2) motion of the tendon in the bone tunnel during cyclic loading when comparing sutured grafts vs. unsutured grafts.

Method

Eight pairs of matched mature porcine tibias (age <2 years) and eight paired fresh-frozen human quadrupled hamstring tendon grafts were used. One quadrupled graft from each pair was placed into one of two groups. In the group A a single cerclage suture 3 cm from the doubled end of the graft was placed to join the four tendon strands. In group B a heavy suture was used to tightly unite the four strands of tendon graft to provide a better grip for the interference screw during fixation. The grafts were placed in tibial bone tunnels that matched the graft’s diameter and fixed with an interference screw. The looped end of the graft and the attached tibia were rigidly fixed in a material testing machine. The graft constructs were subjected to 100 cycles of 20–250 N load, followed by a load-to-failure test. In addition, a motion analysis system was used during cyclic testing to better determine the amount of elongation at the graft–tunnel interface. Statistical analysis of the failure load and stiffness and the overall elongation following cyclical loading was performed using the Wilcoxon rank sum test. Level of significance was set at p < 0.05.

Results

Elongation at the tendon–bone interface during sub-maximal cyclic loading was 2.4 ± 1.4 mm (unsutured) vs. 2.0 ± 0.7 mm (sutured) (p > 0.05). Failure load of the grafts without sutures (634 ± 86 N) was significantly lower than with the sutures (837 ± 183 N). Ultimate stiffness of group A (283 ± 34 N/mm) was lower than that of group B (331 ± 51 N/mm); however, this was not statistically significant (p = 0.051).

Conclusion

This study confirms that suturing of the graft construct before interference screw fixation may increase ultimate failure load. However, an improvement of structural properties in response to cyclic loading with sub-maximal loads could not be confirmed. Clinicians using interference screw fixation may suture the graft to improve fixation strength; however, suturing does not appear to allow a more aggressive rehabilitation after surgery.
Literatur
1.
Zurück zum Zitat Beynnon BD, Fleming BC, Johnson RJ et al (1995) Anterior cruciate ligament strain behavior during rehabilitation exercises in vivo. Am J Sports Med 23:24–34PubMedCrossRef Beynnon BD, Fleming BC, Johnson RJ et al (1995) Anterior cruciate ligament strain behavior during rehabilitation exercises in vivo. Am J Sports Med 23:24–34PubMedCrossRef
2.
Zurück zum Zitat Beynnon BD, Johnson RJ, Abate JA et al (2005) Treatment of anterior cruciate ligament injuries, part I. Am J Sports Med 33:1579–1602PubMedCrossRef Beynnon BD, Johnson RJ, Abate JA et al (2005) Treatment of anterior cruciate ligament injuries, part I. Am J Sports Med 33:1579–1602PubMedCrossRef
3.
Zurück zum Zitat Brand J Jr, Weiler A, Caborn DN et al (2000) Graft fixation in cruciate ligament reconstruction. Am J Sports Med 28:761–774PubMed Brand J Jr, Weiler A, Caborn DN et al (2000) Graft fixation in cruciate ligament reconstruction. Am J Sports Med 28:761–774PubMed
4.
Zurück zum Zitat Bravman J, Ishak C, Gelber J et al (2006) The interaction between the whipstitch sutures of multi-strand ACL grafts and interference screw fixation. Bull Hosp Jt Dis 63:156–157PubMed Bravman J, Ishak C, Gelber J et al (2006) The interaction between the whipstitch sutures of multi-strand ACL grafts and interference screw fixation. Bull Hosp Jt Dis 63:156–157PubMed
5.
Zurück zum Zitat Brown CH Jr, Wilson DR, Hecker AT et al (2004) Graft-bone motion and tensile properties of hamstring and patellar tendon anterior cruciate ligament femoral graft fixation under cyclic loading. Arthroscopy 20:922–935PubMed Brown CH Jr, Wilson DR, Hecker AT et al (2004) Graft-bone motion and tensile properties of hamstring and patellar tendon anterior cruciate ligament femoral graft fixation under cyclic loading. Arthroscopy 20:922–935PubMed
6.
Zurück zum Zitat Charlick DA, Caborn DN (2000) Technical note: alternative soft-tissue graft preparation technique for cruciate ligament reconstruction. Arthroscopy 16:E20PubMedCrossRef Charlick DA, Caborn DN (2000) Technical note: alternative soft-tissue graft preparation technique for cruciate ligament reconstruction. Arthroscopy 16:E20PubMedCrossRef
7.
Zurück zum Zitat Flanigan DC, Kanneganti P, Quinn DP et al (2011) Comparison of ACL fixation devices using cadaveric grafts. J Knee Surg 24:175–180PubMedCrossRef Flanigan DC, Kanneganti P, Quinn DP et al (2011) Comparison of ACL fixation devices using cadaveric grafts. J Knee Surg 24:175–180PubMedCrossRef
8.
Zurück zum Zitat Genuario JW, Faucett SC, Boublik M et al (2012) A cost-effectiveness analysis comparing 3 anterior cruciate ligament graft types: bone-patellar tendon-bone autograft, hamstring autograft, and allograft. Am J Sports Med 40:307–314PubMedCrossRef Genuario JW, Faucett SC, Boublik M et al (2012) A cost-effectiveness analysis comparing 3 anterior cruciate ligament graft types: bone-patellar tendon-bone autograft, hamstring autograft, and allograft. Am J Sports Med 40:307–314PubMedCrossRef
9.
Zurück zum Zitat Herrera A, Martinez F, Iglesias D et al (2010) Fixation strength of biocomposite wedge interference screw in ACL reconstruction: effect of screw length and tunnel/screw ratio. A controlled laboratory study. BMC Musculoskelet Disord 11:139PubMedCrossRef Herrera A, Martinez F, Iglesias D et al (2010) Fixation strength of biocomposite wedge interference screw in ACL reconstruction: effect of screw length and tunnel/screw ratio. A controlled laboratory study. BMC Musculoskelet Disord 11:139PubMedCrossRef
10.
Zurück zum Zitat Hoher J, Livesay GA, Ma CB et al (1999) Hamstring graft motion in the femoral bone tunnel when using titanium button/polyester tape fixation. Knee Surg Sports Traumatol Arthrosc 7:215–219PubMedCrossRef Hoher J, Livesay GA, Ma CB et al (1999) Hamstring graft motion in the femoral bone tunnel when using titanium button/polyester tape fixation. Knee Surg Sports Traumatol Arthrosc 7:215–219PubMedCrossRef
11.
Zurück zum Zitat Hoher J, Scheffler S, Weiler A (2003) Graft choice and graft fixation in PCL reconstruction. Knee Surg Sports Traumatol Arthrosc 11:297–306PubMedCrossRef Hoher J, Scheffler S, Weiler A (2003) Graft choice and graft fixation in PCL reconstruction. Knee Surg Sports Traumatol Arthrosc 11:297–306PubMedCrossRef
12.
Zurück zum Zitat Hoher J, Scheffler SU, Withrow JD et al (2000) Mechanical behavior of two hamstring graft constructs for reconstruction of the anterior cruciate ligament. J Orthop Res 18:456–461PubMedCrossRef Hoher J, Scheffler SU, Withrow JD et al (2000) Mechanical behavior of two hamstring graft constructs for reconstruction of the anterior cruciate ligament. J Orthop Res 18:456–461PubMedCrossRef
13.
Zurück zum Zitat Ishibashi Y, Rudy TW, Livesay GA et al (1997) The effect of anterior cruciate ligament graft fixation site at the tibia on knee stability: evaluation using a robotic testing system. Arthroscopy 13:177–182PubMedCrossRef Ishibashi Y, Rudy TW, Livesay GA et al (1997) The effect of anterior cruciate ligament graft fixation site at the tibia on knee stability: evaluation using a robotic testing system. Arthroscopy 13:177–182PubMedCrossRef
14.
Zurück zum Zitat Kousa P, Jarvinen TL, Vihavainen M et al (2003) The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction. Part I: femoral site. Am J Sports Med 31:174–181PubMed Kousa P, Jarvinen TL, Vihavainen M et al (2003) The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction. Part I: femoral site. Am J Sports Med 31:174–181PubMed
15.
Zurück zum Zitat Krappinger D, Kralinger FS, El Attal R et al (2007) Modified Prusik knot vs. whipstitch technique for soft tissue fixation in anterior cruciate ligament reconstruction: a biomechanical analysis. Knee Surg Sports Traumatol Arthrosc 15:418–423PubMedCrossRef Krappinger D, Kralinger FS, El Attal R et al (2007) Modified Prusik knot vs. whipstitch technique for soft tissue fixation in anterior cruciate ligament reconstruction: a biomechanical analysis. Knee Surg Sports Traumatol Arthrosc 15:418–423PubMedCrossRef
16.
Zurück zum Zitat Lee MC, Jo H, Bae TS et al (2003) Analysis of initial fixation strength of press-fit fixation technique in anterior cruciate ligament reconstruction. A comparative study with titanium and bioabsorbable interference screw using porcine lower limb. Knee Surg Sports Traumatol Arthrosc 11:91–98PubMed Lee MC, Jo H, Bae TS et al (2003) Analysis of initial fixation strength of press-fit fixation technique in anterior cruciate ligament reconstruction. A comparative study with titanium and bioabsorbable interference screw using porcine lower limb. Knee Surg Sports Traumatol Arthrosc 11:91–98PubMed
17.
Zurück zum Zitat Lenschow S, Herbort M, Strasser A et al (2011) Structural properties of a new device for graft fixation in cruciate ligament reconstruction: the shim technique. Arch Orthop Trauma Surg 131:1067–1072PubMedCrossRef Lenschow S, Herbort M, Strasser A et al (2011) Structural properties of a new device for graft fixation in cruciate ligament reconstruction: the shim technique. Arch Orthop Trauma Surg 131:1067–1072PubMedCrossRef
18.
Zurück zum Zitat Prado M, Martin-Castilla B, Espejo-Reina A et al (2012) Close-looped graft suturing improves mechanical properties of interference screw fixation in ACL reconstruction. Knee Surg Sports Traumatol Arthrosc 21:476–484PubMedCrossRef Prado M, Martin-Castilla B, Espejo-Reina A et al (2012) Close-looped graft suturing improves mechanical properties of interference screw fixation in ACL reconstruction. Knee Surg Sports Traumatol Arthrosc 21:476–484PubMedCrossRef
19.
Zurück zum Zitat Scheffler SU, Sudkamp NP, Gockenjan A et al (2002) Biomechanical comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniques: the impact of fixation level and fixation method under cyclic loading. Arthroscopy 18:304–315PubMedCrossRef Scheffler SU, Sudkamp NP, Gockenjan A et al (2002) Biomechanical comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniques: the impact of fixation level and fixation method under cyclic loading. Arthroscopy 18:304–315PubMedCrossRef
20.
Zurück zum Zitat Sorensen OG, Larsen K, Jakobsen BW et al (2011) Serial dilation reduces graft slippage compared to extraction drilling in anterior cruciate ligament reconstruction: a randomized controlled trial using radiostereometric analysis. Knee Surg Sports Traumatol Arthrosc 19:347–354PubMedCrossRef Sorensen OG, Larsen K, Jakobsen BW et al (2011) Serial dilation reduces graft slippage compared to extraction drilling in anterior cruciate ligament reconstruction: a randomized controlled trial using radiostereometric analysis. Knee Surg Sports Traumatol Arthrosc 19:347–354PubMedCrossRef
21.
Zurück zum Zitat Stalder M, Farshad M, Snedeker JG et al (2012) Interference screws should be shorter than the hamstring tendon graft in the bone tunnel for best fixation. Knee Surg Sports Traumatol Arthrosc Stalder M, Farshad M, Snedeker JG et al (2012) Interference screws should be shorter than the hamstring tendon graft in the bone tunnel for best fixation. Knee Surg Sports Traumatol Arthrosc
22.
Zurück zum Zitat Weiler A, Hoffmann RF, Siepe CJ et al (2000) The influence of screw geometry on hamstring tendon interference fit fixation. Am J Sports Med 28:356–359PubMed Weiler A, Hoffmann RF, Siepe CJ et al (2000) The influence of screw geometry on hamstring tendon interference fit fixation. Am J Sports Med 28:356–359PubMed
23.
Zurück zum Zitat Weiler A, Hoffmann RF, Stahelin AC et al (1998) Hamstring tendon fixation using interference screws: a biomechanical study in calf tibial bone. Arthroscopy 14:29–37PubMedCrossRef Weiler A, Hoffmann RF, Stahelin AC et al (1998) Hamstring tendon fixation using interference screws: a biomechanical study in calf tibial bone. Arthroscopy 14:29–37PubMedCrossRef
24.
Zurück zum Zitat Weiler A, Windhagen HJ, Raschke MJ et al (1998) Biodegradable interference screw fixation exhibits pull-out force and stiffness similar to titanium screws. Am J Sports Med 26:119–126PubMedCrossRef Weiler A, Windhagen HJ, Raschke MJ et al (1998) Biodegradable interference screw fixation exhibits pull-out force and stiffness similar to titanium screws. Am J Sports Med 26:119–126PubMedCrossRef
Metadaten
Titel
Impact of tendon suturing on the interference fixation strength of quadrupled hamstring tendon grafts
verfasst von
Jürgen Höher
Christoph Offerhaus
Eric Steenlage
Andreas Weiler
Sven Scheffler
Publikationsdatum
01.09.2013
Verlag
Springer Berlin Heidelberg
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 9/2013
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-013-1749-y

Weitere Artikel der Ausgabe 9/2013

Archives of Orthopaedic and Trauma Surgery 9/2013 Zur Ausgabe

Orthopaedic Surgery

Osteomyelitis

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.