Joint gap measurement in total knee arthroplasty using a tensor device with the same articulating surface as the prosthesis

verfasst von: Yoshio Matsui, Shigeru Nakagawa, Yukihide Minoda, Shigekazu Mizokawa, Yoshio Tokuhara, Yoshinori Kadoya

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 5/2014

Einloggen, um Zugang zu erhalten

Abstract

Background

We developed a new tensor to measure the joint gap throughout knee flexion during total knee arthroplasty (TKA). This tensor has the same articular shape as that of the tibial liner, including the post structure and the curvature of femorotibial articular surface, to measure the gap intraoperatively under the same conditions as after TKA. The present study aimed to examine the precision of the new tensor for gap measurement after implantation.

Methods

We performed TKA using the modified gap technique in four cadaveric knees and measured the gaps using the new tensor. The intra-observer and inter-observer error of the tensor was analyzed using 168 measurements of the gaps as determined at least twice by two surgeons. In addition, the gaps in rotating-platform posterior-stabilized TKA were measured at seven positions with the knee bending from extension to full flexion.

Results

The inter-observer and intra-observer errors were 0.8 and 0.3 mm, respectively, indicating precise and reproducible gap measurement. The gaps before implantation in reduced patellar position were 12.1 mm at extension and 12.5 mm at 90° flexion. The gaps after implantation were 9.1, 12.9, 13.1, 13.5, 13.8, 13.3, and 10.1 mm at 0°, 30°, 45°, 60°, 90°, 120°, and full flexion, respectively.

Conclusions

The new tensor provides precise and reproducible measurements. Although the joint gap before implantation was parallel and equal at extension and 90° flexion, the joint gap after implantation was variable throughout knee flexion. This feature of the gap should be considered during the operation.
Literatur
1.
Zurück zum Zitat Insall JN, Scott WN (eds) (2001) Surgery of the knee, 3rd edn. Churchill Livingstone, New York, pp 1553–1620 Insall JN, Scott WN (eds) (2001) Surgery of the knee, 3rd edn. Churchill Livingstone, New York, pp 1553–1620
2.
Zurück zum Zitat Griffin FM, Insall JN, Scuderi GR (2000) Accuracy of soft tissue balancing in total knee arthroplasty. J Arthroplasty 15:970–973PubMedCrossRef Griffin FM, Insall JN, Scuderi GR (2000) Accuracy of soft tissue balancing in total knee arthroplasty. J Arthroplasty 15:970–973PubMedCrossRef
3.
Zurück zum Zitat Mihalko WM, Whiteside LA, Krackow KA (2003) Comparison of ligament-balancing techniques during total knee arthroplasty. J Bone Joint Surg Am 85:132PubMed Mihalko WM, Whiteside LA, Krackow KA (2003) Comparison of ligament-balancing techniques during total knee arthroplasty. J Bone Joint Surg Am 85:132PubMed
4.
Zurück zum Zitat Unitt L, Sambatakakis A, Johnstone D, Briggs TW (2008) Short-term outcome in total knee replacement after soft-tissue release and balancing. J Bone Joint Surg Br 90-B:159–165CrossRef Unitt L, Sambatakakis A, Johnstone D, Briggs TW (2008) Short-term outcome in total knee replacement after soft-tissue release and balancing. J Bone Joint Surg Br 90-B:159–165CrossRef
5.
Zurück zum Zitat Winemaker MJ (2002) Perfect balance in total knee arthroplasty: the elusive compromise. J Arthroplasty 17:2–10PubMedCrossRef Winemaker MJ (2002) Perfect balance in total knee arthroplasty: the elusive compromise. J Arthroplasty 17:2–10PubMedCrossRef
6.
Zurück zum Zitat Kadoya Y, Kobayashi A, Komatsu T, Nakagawa S, Yamano Y (2001) Effects of posterior cruciate ligament resection on tibiofemoral joint gap. Clin Orthop 391:210–217PubMedCrossRef Kadoya Y, Kobayashi A, Komatsu T, Nakagawa S, Yamano Y (2001) Effects of posterior cruciate ligament resection on tibiofemoral joint gap. Clin Orthop 391:210–217PubMedCrossRef
7.
Zurück zum Zitat Matsumoto T, Muratsu H, Tsumura N, Mizuno K, Kuroda R, Yoshiya S, Kurosaka M (2006) Joint gap kinematics in posterior-stabilized total knee arthroplasty measured by a new tensor with the navigation system. J Biomed Eng 128:867–871 Matsumoto T, Muratsu H, Tsumura N, Mizuno K, Kuroda R, Yoshiya S, Kurosaka M (2006) Joint gap kinematics in posterior-stabilized total knee arthroplasty measured by a new tensor with the navigation system. J Biomed Eng 128:867–871
8.
Zurück zum Zitat Matsumoto T, Kuroda R, Kubo S, Muratsu H, Mizuno K, Kurosaka M (2009) The intra-operative joint gap in cruciate-retaining compared with posterior-stabilised total knee replacement. J Bone Joint Surg Br 91-B:475–480CrossRef Matsumoto T, Kuroda R, Kubo S, Muratsu H, Mizuno K, Kurosaka M (2009) The intra-operative joint gap in cruciate-retaining compared with posterior-stabilised total knee replacement. J Bone Joint Surg Br 91-B:475–480CrossRef
9.
Zurück zum Zitat Gejo R, Morita Y, Matsushita I, Sugimori K, Kimura T (2008) Joint gap changes with patellar tendon strain and patellar position during TKA. Clin Orthop 466:946–951PubMedCentralPubMedCrossRef Gejo R, Morita Y, Matsushita I, Sugimori K, Kimura T (2008) Joint gap changes with patellar tendon strain and patellar position during TKA. Clin Orthop 466:946–951PubMedCentralPubMedCrossRef
10.
Zurück zum Zitat Jeffcote B, Nicholls R, Schirm A, Kuster MS (2007) The variation in medial and lateral collateral ligament strain and tibiofemoral forces following changes in the flexion and extension gaps in total knee replacement. J Bone Joint Surg Br 89-B:1528–1533CrossRef Jeffcote B, Nicholls R, Schirm A, Kuster MS (2007) The variation in medial and lateral collateral ligament strain and tibiofemoral forces following changes in the flexion and extension gaps in total knee replacement. J Bone Joint Surg Br 89-B:1528–1533CrossRef
11.
Zurück zum Zitat Mitsuyasu H, Matsuda S, Fukagawa S, Okazaki K, Tashiro Y, Kawahara S, Nakahara H, Iwamoto Y (2011) Enlarged post-operative posterior condyle tightens extension gap in total knee arthroplasty. J Bone Joint Surg Br 93-B:1210–1216CrossRef Mitsuyasu H, Matsuda S, Fukagawa S, Okazaki K, Tashiro Y, Kawahara S, Nakahara H, Iwamoto Y (2011) Enlarged post-operative posterior condyle tightens extension gap in total knee arthroplasty. J Bone Joint Surg Br 93-B:1210–1216CrossRef
12.
Zurück zum Zitat Ender J, Korhan O, Koray U, Mahir M, Engin E, Omer T (2008) Lateral dislocation of the knee joint after total knee arthroplasty: a report. Cases J. 1(1):75 Ender J, Korhan O, Koray U, Mahir M, Engin E, Omer T (2008) Lateral dislocation of the knee joint after total knee arthroplasty: a report. Cases J. 1(1):75
13.
Zurück zum Zitat Hagedorn J, Levine BR (2012) Revision surgery for a dislocated constrained total knee arthroplasty. Orthopedics 35(7):e1099–e1103PubMedCrossRef Hagedorn J, Levine BR (2012) Revision surgery for a dislocated constrained total knee arthroplasty. Orthopedics 35(7):e1099–e1103PubMedCrossRef
14.
Zurück zum Zitat Xiaojun S, Bin S, Pengde K, Jing Y, Zongke Z, Fuxing P The effect of posterior tibial slope on knee flexion in posterior-stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. Published online: 02 June 2012 Xiaojun S, Bin S, Pengde K, Jing Y, Zongke Z, Fuxing P The effect of posterior tibial slope on knee flexion in posterior-stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. Published online: 02 June 2012
15.
Zurück zum Zitat Fujimoto E, Ssashige Y, Masuda Y, Hisatome T, Eguchi A, Masuda T, Sawa M, Nagata Y. Significant effect of the posterior tibial slope and medial/lateral ligament balance on knee flexion in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. Published online: 30 May 2012 Fujimoto E, Ssashige Y, Masuda Y, Hisatome T, Eguchi A, Masuda T, Sawa M, Nagata Y. Significant effect of the posterior tibial slope and medial/lateral ligament balance on knee flexion in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. Published online: 30 May 2012
16.
Zurück zum Zitat Bellemans J, Robijns F, Duerinckx J, Banks S, Vandenneucker H (2005) The influence of tibial slope on maximal flexion after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 13:193–196PubMedCrossRef Bellemans J, Robijns F, Duerinckx J, Banks S, Vandenneucker H (2005) The influence of tibial slope on maximal flexion after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 13:193–196PubMedCrossRef
17.
Zurück zum Zitat Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomized study. J Bone Joint Surg Br 85-B:830–835 Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomized study. J Bone Joint Surg Br 85-B:830–835
18.
Zurück zum Zitat Stulberg SD, Loan P, Sarin V (2002) Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg Am 84-A:90–98PubMed Stulberg SD, Loan P, Sarin V (2002) Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg Am 84-A:90–98PubMed
Metadaten
Titel
Joint gap measurement in total knee arthroplasty using a tensor device with the same articulating surface as the prosthesis
verfasst von
Yoshio Matsui
Shigeru Nakagawa
Yukihide Minoda
Shigekazu Mizokawa
Yoshio Tokuhara
Yoshinori Kadoya
Publikationsdatum
01.05.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 5/2014
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-014-1945-4

Weitere Artikel der Ausgabe 5/2014

Archives of Orthopaedic and Trauma Surgery 5/2014 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.