Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 1/2015

01.01.2015 | Knee Arthroplasty

High-flexion posterior-substituting versus cruciate-retaining prosthesis in total knee arthroplasty: functional outcome, range of motion and complication comparison

verfasst von: Zhenxiang Zhang, Wei Zhu, Wenjie Zhang

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 1/2015

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Currently, a high-flexion cruciate-retaining knee prosthesis has been designed to allow greater advantage after total knee arthroplasty (TKA). The present study was conducted to compare functional outcome, range of motion (ROM) as well as complications in subjects who underwent either a high-flexion cruciate-retaining (HFCR, Group I) or a high-flexion posterior-substituting (HFPS, Group II) prosthesis TKA.

Methods

Thirty-four subjects which had TKA with HFCR prosthesis and thirty-three subjects which had TKA with HFPS prosthesis were enrolled in our study and were assessed preoperatively and at 24 months postoperatively. For functional outcome comparison, Hospital for Special Surgery Score (HSSS), Knee Society Score (KSS, including the Mean Knee Score and the Mean Function Score) as well as SF12 Score (including Mental Health Score and Physical Health Score) were measured. For ROM comparison, the arcs of maximal non-weight-bearing passive flexion and weight-bearing flexion were detected, and the number of knees which allowed patients to kneel and sit cross-legged in comfort was determined. For complication comparison, wound necrosis/discharge, anterior knee pain, dislocation, radiolucent lines as well as osteolysis were investigated.

Results

At 24-month follow-up, no significant difference in functional outcome between the two groups was detected. The average maximal non-weight-bearing flexion was 136.2° for the knees in Group I and 135.1° for the knees in Group II (P > 0.05). The average weight-bearing flexion was 123.2° for the knees in Group I and 129.8° for the knees in Group II (P > 0.05). No significant difference, with regard to the number of knees that allowed kneeling and sitting cross-legged, was detected. Comparisons of postoperative complications between the two groups did not yield a significant difference.

Conclusions

Our study demonstrated no advantage of the high-flexion cruciate- retaining TKA over high-flexion posterior-substituting TKA with regard to functional outcome, range of motion as well as complications at short-term follow-up. However, longer follow-up is necessary to confirm whether these results are sustained.
Literatur
1.
Zurück zum Zitat Schroer WC, Stormont DM, Pietrzak WS (2014) Seven-year survivorship and functional outcomes of the high-flexion vanguard complete knee system. J Arthroplasty 29(1):61–65PubMedCrossRef Schroer WC, Stormont DM, Pietrzak WS (2014) Seven-year survivorship and functional outcomes of the high-flexion vanguard complete knee system. J Arthroplasty 29(1):61–65PubMedCrossRef
2.
Zurück zum Zitat Fischer M, von Eisenhart-Rothe R, Simank HG (2013) Comparable short-term results seen with standard and high-flexion knee arthroplasty designs in European patients. J Orthop 10(3):119–122PubMedCentralPubMedCrossRef Fischer M, von Eisenhart-Rothe R, Simank HG (2013) Comparable short-term results seen with standard and high-flexion knee arthroplasty designs in European patients. J Orthop 10(3):119–122PubMedCentralPubMedCrossRef
3.
Zurück zum Zitat van de Groes S, de Waal-Malefijt M, Verdonschot N (2014) Probability of mechanical loosening of the femoral component in high flexion total knee arthroplasty can be reduced by rather simple surgical techniques. Knee 21(1):209–215PubMedCrossRef van de Groes S, de Waal-Malefijt M, Verdonschot N (2014) Probability of mechanical loosening of the femoral component in high flexion total knee arthroplasty can be reduced by rather simple surgical techniques. Knee 21(1):209–215PubMedCrossRef
4.
Zurück zum Zitat Guild GN 3rd, Labib SA (2014) Clinical outcomes in high flexion total knee arthroplasty were not superior to standard posterior stabilized total knee arthroplasty. A multicenter, prospective, randomized study. J Arthroplasty 29(3):530–534PubMedCrossRef Guild GN 3rd, Labib SA (2014) Clinical outcomes in high flexion total knee arthroplasty were not superior to standard posterior stabilized total knee arthroplasty. A multicenter, prospective, randomized study. J Arthroplasty 29(3):530–534PubMedCrossRef
5.
Zurück zum Zitat Luo SX, Su W, Zhao JM, Sha K, Wei QJ, Li XF (2011) High-flexion vs conventional prostheses total knee arthroplasty: a meta-analysis. J Arthroplasty 26(6):847–854PubMedCrossRef Luo SX, Su W, Zhao JM, Sha K, Wei QJ, Li XF (2011) High-flexion vs conventional prostheses total knee arthroplasty: a meta-analysis. J Arthroplasty 26(6):847–854PubMedCrossRef
6.
7.
Zurück zum Zitat Luo SX, Zhao JM, Su W, Li XF, Dong GF (2012) Posterior cruciate substituting versus posterior cruciate retaining total knee arthroplasty prostheses: a meta-analysis. Knee 19(4):246–252PubMedCrossRef Luo SX, Zhao JM, Su W, Li XF, Dong GF (2012) Posterior cruciate substituting versus posterior cruciate retaining total knee arthroplasty prostheses: a meta-analysis. Knee 19(4):246–252PubMedCrossRef
8.
Zurück zum Zitat Most E, Zayontz S, Li G, Otterberg E, Sabbag K, Rubash HE (2003) Femoral rollback after cruciate-retaining and stabilizing total knee arthroplasty. Clin Orthop Relat Res 410:101–113PubMedCrossRef Most E, Zayontz S, Li G, Otterberg E, Sabbag K, Rubash HE (2003) Femoral rollback after cruciate-retaining and stabilizing total knee arthroplasty. Clin Orthop Relat Res 410:101–113PubMedCrossRef
9.
Zurück zum Zitat Sierra RJ, Berry DJ (2008) Surgical technique differences between posterior-substituting and cruciate-retaining total knee arthroplasty. J Arthroplasty 23(7):20–23PubMedCrossRef Sierra RJ, Berry DJ (2008) Surgical technique differences between posterior-substituting and cruciate-retaining total knee arthroplasty. J Arthroplasty 23(7):20–23PubMedCrossRef
10.
Zurück zum Zitat Incavo SJ, Mullins ER, Coughlin KM, Banks S, Banks A, Beynnon BD (2004) Tibiofemoral kinematic analysis of kneeling after total knee arthroplasty. J Arthroplasty 19(7):906–910PubMedCrossRef Incavo SJ, Mullins ER, Coughlin KM, Banks S, Banks A, Beynnon BD (2004) Tibiofemoral kinematic analysis of kneeling after total knee arthroplasty. J Arthroplasty 19(7):906–910PubMedCrossRef
11.
Zurück zum Zitat Song EK, Park SJ, Yoon TR, Park KS, Seo HY, Seon JK (2012) Hi-flexion and gender-specific designs fail to provide significant increases in range of motion during cruciate-retaining total knee arthroplasty. J Arthroplasty 27(6):1081–1084PubMedCrossRef Song EK, Park SJ, Yoon TR, Park KS, Seo HY, Seon JK (2012) Hi-flexion and gender-specific designs fail to provide significant increases in range of motion during cruciate-retaining total knee arthroplasty. J Arthroplasty 27(6):1081–1084PubMedCrossRef
12.
Zurück zum Zitat Minoda Y, Aihara M, Sakawa A, Fukuoka S, Hayakawa K, Ohzono K (2012) Range of motion of standard and high-flexion cruciate retaining total knee prostheses. J Arthroplasty 24(5):674–680CrossRef Minoda Y, Aihara M, Sakawa A, Fukuoka S, Hayakawa K, Ohzono K (2012) Range of motion of standard and high-flexion cruciate retaining total knee prostheses. J Arthroplasty 24(5):674–680CrossRef
13.
Zurück zum Zitat Yagishita K, Muneta T, Ju YJ, Morito T, Yamazaki J, Sekiya I (2012) High-flex posterior cruciate-retaining vs posterior cruciate-substituting designs in simultaneous bilateral total knee arthroplasty: a prospective, randomized study. J Arthroplasty 27(3):368–374PubMedCrossRef Yagishita K, Muneta T, Ju YJ, Morito T, Yamazaki J, Sekiya I (2012) High-flex posterior cruciate-retaining vs posterior cruciate-substituting designs in simultaneous bilateral total knee arthroplasty: a prospective, randomized study. J Arthroplasty 27(3):368–374PubMedCrossRef
14.
Zurück zum Zitat Cates HE, Komistek RD, Mahfouz MR, Schmidt MA, Anderle M (2008) In vivo comparison of knee kinematics for subjects having either a posterior stabilized or cruciate retaining high-flexion total knee arthroplasty. J Arthroplasty 23(7):1057–1067PubMedCrossRef Cates HE, Komistek RD, Mahfouz MR, Schmidt MA, Anderle M (2008) In vivo comparison of knee kinematics for subjects having either a posterior stabilized or cruciate retaining high-flexion total knee arthroplasty. J Arthroplasty 23(7):1057–1067PubMedCrossRef
15.
Zurück zum Zitat Seon JK, Park JK, Shin YJ, Seo HY, Lee KB, Song EK (2011) Comparisons of kinematics and range of motion in high-flexion total knee arthroplasty: cruciate retaining vs. substituting designs. Knee Surg Sports Traumatol Arthrosc 19(12):2016–2022PubMedCrossRef Seon JK, Park JK, Shin YJ, Seo HY, Lee KB, Song EK (2011) Comparisons of kinematics and range of motion in high-flexion total knee arthroplasty: cruciate retaining vs. substituting designs. Knee Surg Sports Traumatol Arthrosc 19(12):2016–2022PubMedCrossRef
16.
Zurück zum Zitat Seon JK, Park SJ, Lee KB, Yoon TR, Kozanek M, Song EK (2009) Range of motion in total knee arthroplasty: a prospective comparison of high-flexion and standard cruciate-retaining designs. J Bone Joint Surg Am 91(3):672–679PubMedCrossRef Seon JK, Park SJ, Lee KB, Yoon TR, Kozanek M, Song EK (2009) Range of motion in total knee arthroplasty: a prospective comparison of high-flexion and standard cruciate-retaining designs. J Bone Joint Surg Am 91(3):672–679PubMedCrossRef
17.
Zurück zum Zitat Thadani PJ, Vince KG, Ortaaslan SG, Blackburn DC, Cudiamat CV (2000) Ten- to 12-year followup of the Insall-Burstein I total knee prosthesis. Clin Orthop Relat Res 380:17–29PubMedCrossRef Thadani PJ, Vince KG, Ortaaslan SG, Blackburn DC, Cudiamat CV (2000) Ten- to 12-year followup of the Insall-Burstein I total knee prosthesis. Clin Orthop Relat Res 380:17–29PubMedCrossRef
18.
Zurück zum Zitat van Stralen RA, Anderson PG, Wymenga AB (2013) The self-aligning knee prosthesis: clinical and radiological outcome and survival analysis of a cruciate retaining meniscal bearing knee at 10-year follow-up. Knee Surg Sports Traumatol Arthrosc [Epub ahead of print] van Stralen RA, Anderson PG, Wymenga AB (2013) The self-aligning knee prosthesis: clinical and radiological outcome and survival analysis of a cruciate retaining meniscal bearing knee at 10-year follow-up. Knee Surg Sports Traumatol Arthrosc [Epub ahead of print]
19.
Zurück zum Zitat Peters CL, Mulkey P, Erickson J, Anderson MB, Pelt CE (2014) Comparison of total knee arthroplasty with highly congruent anterior-stabilized bearings versus a cruciate-retaining design. Clin Orthop Relat Res 472(1):175–180PubMedCrossRef Peters CL, Mulkey P, Erickson J, Anderson MB, Pelt CE (2014) Comparison of total knee arthroplasty with highly congruent anterior-stabilized bearings versus a cruciate-retaining design. Clin Orthop Relat Res 472(1):175–180PubMedCrossRef
20.
Zurück zum Zitat Cho SH, Ha YC, Song HR, Jeong ST, Park HB, Hwang SC, Kim JS (2004) High flex knee arthroplasty and range of motion. J Korean Orthop Assoc 39:662–667 Cho SH, Ha YC, Song HR, Jeong ST, Park HB, Hwang SC, Kim JS (2004) High flex knee arthroplasty and range of motion. J Korean Orthop Assoc 39:662–667
21.
Zurück zum Zitat Han HS, Kang SB, Yoon KS (2007) High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement. J Bone Joint Surg Br 89(11):1457–1461PubMedCrossRef Han HS, Kang SB, Yoon KS (2007) High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement. J Bone Joint Surg Br 89(11):1457–1461PubMedCrossRef
22.
Zurück zum Zitat Zelle J, Janssen D, Van Eijden J (2011) Does high-flexion total knee arthroplasty promote early loosening of the femoral component? J Orthop Res 29(7):976–983PubMedCrossRef Zelle J, Janssen D, Van Eijden J (2011) Does high-flexion total knee arthroplasty promote early loosening of the femoral component? J Orthop Res 29(7):976–983PubMedCrossRef
23.
Zurück zum Zitat Lee BS, Chung JW, Kim JM (2013) High-flexion prosthesis improves function of TKA in Asian patients without decreasing early survivorship. Clin Orthop Relat Res 471(5):1504–1511PubMedCentralPubMedCrossRef Lee BS, Chung JW, Kim JM (2013) High-flexion prosthesis improves function of TKA in Asian patients without decreasing early survivorship. Clin Orthop Relat Res 471(5):1504–1511PubMedCentralPubMedCrossRef
24.
Zurück zum Zitat Bin SI, Nam TS (2007) Early results of high-flex total knee arthroplasty: comparison study at 1 year after surgery. Knee Surg Sports Traumatol Arthrosc 15:350–355PubMedCrossRef Bin SI, Nam TS (2007) Early results of high-flex total knee arthroplasty: comparison study at 1 year after surgery. Knee Surg Sports Traumatol Arthrosc 15:350–355PubMedCrossRef
Metadaten
Titel
High-flexion posterior-substituting versus cruciate-retaining prosthesis in total knee arthroplasty: functional outcome, range of motion and complication comparison
verfasst von
Zhenxiang Zhang
Wei Zhu
Wenjie Zhang
Publikationsdatum
01.01.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 1/2015
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-014-2107-4

Weitere Artikel der Ausgabe 1/2015

Archives of Orthopaedic and Trauma Surgery 1/2015 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.