Introduction

The minimally invasive plate osteosynthesis (MIPO) technique has been introduced recently. The extensive comminuted fractures of the distal radial metaphysis with diaphyseal involvement are probably good indications for MIPO technique because of less extensive dissection and soft-tissue stripping. The purpose of this retrospective study was to compare the clinical results of MIPO technique to those of conventional open reduction in extensive metadiaphyseal fractures of distal radius.

Materials and methods

Of 34 patients treated for comminuted metadiaphyseal fractures of the distal radius between June 2006 and May 2012, all the patients had extra-articular fractures. Twenty-one patients underwent MIPO technique and 13 underwent conventional open reduction with long periarticular locking plates system (Zimmer). Six patients in the MIPO group and three in the conventional group who had concomitant distal ulnar fractures or distal radioulnar joint (DRUJ) injury underwent plate osteosynthesis or Kirschner-wire fixation before radial fixation. Perioperative parameters and union time were recorded. Radiologic assessment, Mayo Wrist Score, and satisfaction scale were evaluated at the final follow-up.

Results

All fractures united without secondary procedures. Radiologic assessment, Mayo wrist score, and time to union showed no significant difference between the two groups, but the MIPO group had significantly smaller incision wound, higher satisfaction scale, and shorter operative time than did the conventional group.

Conclusions

MIPO is capable of achieving functional results as good as those of conventional open reduction, with a higher satisfaction scale, smaller incision, and shorter operative time. When MIPO intervention is planned, concurrent distal ulnar fracture or DRUJ injury should be repaired first, thus facilitating subsequent indirect reduction. For treating intra-articular fractures, anatomical reduction of the articular surface is more important, and the MIPO technique described here is not recommended.
Literatur
1.
Zurück zum Zitat Chung KC, Watt AJ, Kotsis SV, Margaliot Z, Haase SC, Kim HM (2006) Treatment of unstable distal radial fractures with the volar locking plating system. J Bone Joint Surg Am 88:2687–2694CrossRefPubMed Chung KC, Watt AJ, Kotsis SV, Margaliot Z, Haase SC, Kim HM (2006) Treatment of unstable distal radial fractures with the volar locking plating system. J Bone Joint Surg Am 88:2687–2694CrossRefPubMed
2.
Zurück zum Zitat Oshige T, Sakai A, Zenke Y, Moritani S, Nakamura T (2007) A comparative study for clinical and radiological outcomes of dorsally displaced, unstable distal radius fractures: intrafocal pinning versus volar locking plating. J Hand Surg Am 32:1382–1392CrossRef Oshige T, Sakai A, Zenke Y, Moritani S, Nakamura T (2007) A comparative study for clinical and radiological outcomes of dorsally displaced, unstable distal radius fractures: intrafocal pinning versus volar locking plating. J Hand Surg Am 32:1382–1392CrossRef
3.
Zurück zum Zitat Jupiter JP, Marent-Huber M, LCP Study Group et al (2009) Operative management of distal radial fractures with 2.4-millimeter locking plates. A multicenter prospective case series. J Bone Joint Surg Am 91:55–65CrossRef Jupiter JP, Marent-Huber M, LCP Study Group et al (2009) Operative management of distal radial fractures with 2.4-millimeter locking plates. A multicenter prospective case series. J Bone Joint Surg Am 91:55–65CrossRef
4.
Zurück zum Zitat Perren SM (2002) Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg Br 84:1093–1110CrossRefPubMed Perren SM (2002) Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg Br 84:1093–1110CrossRefPubMed
5.
Zurück zum Zitat Bolhofner BR, Carmen B, Clifford P (1996) The results of open reduction and Internal fixation of distal femur fractures using a biologic (indirect) reduction technique. J Orthop Trauma 10:372–377CrossRefPubMed Bolhofner BR, Carmen B, Clifford P (1996) The results of open reduction and Internal fixation of distal femur fractures using a biologic (indirect) reduction technique. J Orthop Trauma 10:372–377CrossRefPubMed
6.
Zurück zum Zitat Krettek C, Schandelmaier P, Miclau T, Tscherne H (1997) Minimally invasive percutaneous plate osteosynthesis (MIPPO) using the DCS in proximal and distal femoral fractures. Injury 28:A20–A30CrossRefPubMed Krettek C, Schandelmaier P, Miclau T, Tscherne H (1997) Minimally invasive percutaneous plate osteosynthesis (MIPPO) using the DCS in proximal and distal femoral fractures. Injury 28:A20–A30CrossRefPubMed
7.
Zurück zum Zitat Ji F, Tong D, Tang H, Cai X, Zhang Q, Li J et al (2009) Minimally invasive percutaneous plate osteosynthesis (MIPPO) technique applied in the treatment of humeral shaft distal fractures through a lateral approach. Int Orthop 33:543–547CrossRefPubMedCentralPubMed Ji F, Tong D, Tang H, Cai X, Zhang Q, Li J et al (2009) Minimally invasive percutaneous plate osteosynthesis (MIPPO) technique applied in the treatment of humeral shaft distal fractures through a lateral approach. Int Orthop 33:543–547CrossRefPubMedCentralPubMed
8.
Zurück zum Zitat Rancan M, Dietrich M, Lamdark T, Can U, Platz A (2010) Minimal invasive long PHILOS-plate osteosynthesis in metadiaphyseal fractures of the proximal humerus. Injury 41:1277–1283CrossRefPubMed Rancan M, Dietrich M, Lamdark T, Can U, Platz A (2010) Minimal invasive long PHILOS-plate osteosynthesis in metadiaphyseal fractures of the proximal humerus. Injury 41:1277–1283CrossRefPubMed
9.
Zurück zum Zitat Zhou ZB, Gao YS, Tang MJ, Sun YQ, Zhang CQ (2012) Minimally invasive percutaneous osteosynthesis for proximal humeral shaft fractures with the PHILOS through the deltopectoral approach. Int Orthop 36:2341–2345CrossRefPubMedCentralPubMed Zhou ZB, Gao YS, Tang MJ, Sun YQ, Zhang CQ (2012) Minimally invasive percutaneous osteosynthesis for proximal humeral shaft fractures with the PHILOS through the deltopectoral approach. Int Orthop 36:2341–2345CrossRefPubMedCentralPubMed
10.
Zurück zum Zitat Imatani J, Noda T, Morito Y, Sato T, Hashizume H, Inoue H (2005) Minimally invasive plate osteosynthesis for comminuted fractures of the metaphysis of the radius. J Hand Surg Br 30:220–225CrossRefPubMed Imatani J, Noda T, Morito Y, Sato T, Hashizume H, Inoue H (2005) Minimally invasive plate osteosynthesis for comminuted fractures of the metaphysis of the radius. J Hand Surg Br 30:220–225CrossRefPubMed
11.
Zurück zum Zitat Orbay JL, Touhami A, Orbay C (2005) Fixed angle fixation of distal radius fractures through a minimal invasive approach. Tech Hand Up Extrem Surg 9:142–148CrossRefPubMed Orbay JL, Touhami A, Orbay C (2005) Fixed angle fixation of distal radius fractures through a minimal invasive approach. Tech Hand Up Extrem Surg 9:142–148CrossRefPubMed
12.
Zurück zum Zitat Sen MK, Strauss N, Harvey EJ (2008) Minimally invasive plate osteosynthesis of distal radius fractures using a pronator sparing approach. Tech Hand Up Extrem Surg 12:2–6CrossRefPubMed Sen MK, Strauss N, Harvey EJ (2008) Minimally invasive plate osteosynthesis of distal radius fractures using a pronator sparing approach. Tech Hand Up Extrem Surg 12:2–6CrossRefPubMed
13.
Zurück zum Zitat Dos Remedios C, Nebout J, Benlarbi H, Caremier E, Sam-Wing JF, Beya R (2009) Pronator quadratus preservation for distal radius fractures with locking palmar plate osteosynthesis. Surgical technique. Chir Main 28:224–229CrossRefPubMed Dos Remedios C, Nebout J, Benlarbi H, Caremier E, Sam-Wing JF, Beya R (2009) Pronator quadratus preservation for distal radius fractures with locking palmar plate osteosynthesis. Surgical technique. Chir Main 28:224–229CrossRefPubMed
14.
Zurück zum Zitat Zenke Y, Sakai A, Oshige T, Moritani S, Fuse Y, Maehara T et al (2011) Clinical results of volar locking plate for distal radius fractures: conventional versus minimally invasive plate osteosynthesis. J Orthop Trauma 25:425–431CrossRefPubMed Zenke Y, Sakai A, Oshige T, Moritani S, Fuse Y, Maehara T et al (2011) Clinical results of volar locking plate for distal radius fractures: conventional versus minimally invasive plate osteosynthesis. J Orthop Trauma 25:425–431CrossRefPubMed
15.
Zurück zum Zitat Amadio PC, Berquist TH, Smith DK, Ilstrup DM, Cooney WP 3rd, Linscheid RL (1989) Scaphoid malunion. J Hand Surg Am 14:679–687CrossRefPubMed Amadio PC, Berquist TH, Smith DK, Ilstrup DM, Cooney WP 3rd, Linscheid RL (1989) Scaphoid malunion. J Hand Surg Am 14:679–687CrossRefPubMed
16.
Zurück zum Zitat Orbay JL, Touhami A (2006) Current concepts in volar fixed-angle fixation of unstable distal radius fractures. Clin Orthop Relat Res 445:58–67PubMed Orbay JL, Touhami A (2006) Current concepts in volar fixed-angle fixation of unstable distal radius fractures. Clin Orthop Relat Res 445:58–67PubMed
17.
Zurück zum Zitat Hershman SH, Immerman I, Bechtel C, Lekic N, Paksima N, Egol KA (2013) The effects of pronator quadratus repair on outcomes after volar plating of distal radius fractures. J Orthop Trauma 27:130–133CrossRefPubMed Hershman SH, Immerman I, Bechtel C, Lekic N, Paksima N, Egol KA (2013) The effects of pronator quadratus repair on outcomes after volar plating of distal radius fractures. J Orthop Trauma 27:130–133CrossRefPubMed
18.
Zurück zum Zitat Varitimidis SE, Basdekis GK, Dailiana ZH, Hantes ME, Bargiotas K, Malizos K (2008) Treatment of intraarticular fractures of the distal radius: fluoroscopic or arthroscopic reduction? J Bone Joint Surg Br 90:778–785CrossRefPubMed Varitimidis SE, Basdekis GK, Dailiana ZH, Hantes ME, Bargiotas K, Malizos K (2008) Treatment of intraarticular fractures of the distal radius: fluoroscopic or arthroscopic reduction? J Bone Joint Surg Br 90:778–785CrossRefPubMed
19.
Zurück zum Zitat Haerle M, Schaller HE, Mathoulin C (2003) Vascular anatomy of the palmar surfaces of the distal radius and ulna: its relevance to pedicled bone grafts at the distal palmar forearm. J Hand Surg Br 28:131–136CrossRefPubMed Haerle M, Schaller HE, Mathoulin C (2003) Vascular anatomy of the palmar surfaces of the distal radius and ulna: its relevance to pedicled bone grafts at the distal palmar forearm. J Hand Surg Br 28:131–136CrossRefPubMed
20.
Zurück zum Zitat Rampoldi M, Palombi D, Tagliente D (2011) Distal radius fractures with diaphyseal involvement: fixation with fixed angle volar plate. J Orthop Traumatol 12:137–143CrossRefPubMedCentralPubMed Rampoldi M, Palombi D, Tagliente D (2011) Distal radius fractures with diaphyseal involvement: fixation with fixed angle volar plate. J Orthop Traumatol 12:137–143CrossRefPubMedCentralPubMed
Metadaten
Titel
Clinical results of using minimally invasive long plate osteosynthesis versus conventional approach for extensive comminuted metadiaphyseal fractures of the radius
verfasst von
Chun-Yu Chen
Kai-Cheng Lin
Shan-Wei Yang
Jenn-Huei Renn
Yih-Wen Tarng
Publikationsdatum
01.03.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 3/2015
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-015-2162-5

Weitere Artikel der Ausgabe 3/2015

Archives of Orthopaedic and Trauma Surgery 3/2015 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.