Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 5/2015

01.05.2015 | Hip Arthroplasty

No difference in clinical outcome, bone density and polyethylene wear 5–7 years after standard navigated vs. conventional cementfree total hip arthroplasty

verfasst von: Armin Keshmiri, Christoph Schröter, Markus Weber, Benjamin Craiovan, Joachim Grifka, Tobias Renkawitz

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 5/2015

Einloggen, um Zugang zu erhalten

Abstract

Introduction

The purpose of this investigation was to compare clinical outcome, component loosening, polyethylene cup wear and periprosthetic bone mineral density between “cup first” navigated and conventional cementless total hip arthroplasty (THA) 5–7 years after surgery.

Materials and methods

Fifty patients who received THA with (n = 25) or without (n = 25) the use of an image-free navigation system by a single surgeon were investigated after a mean follow-up of 6.4 (4.8–7.4) years. The Hip Osteoarthritis Outcome Score (HOOS) and the Harris Hip Score (HHS) were obtained; range-of-motion (ROM) was evaluated by a blinded examiner. Radiographic cup inclination, signs of radiographic loosening and polyethylene wear were analysed with the help of digital analysis software on anterio-posterior radiographs by a blinded examiner. Acetabular and femoral periprosthetic bone density was evaluated with the help of dual-energy X-ray absorptiometry.

Results

We were unable to find any statistical significant or clinically relevant difference for the HOOS, HHS, ROM and polyethylene wear between the navigated and the conventional THA group 5–7 years after surgery. Cup inclination was more precise in the navigated THA group in relation to the target value of 45°.

Conclusions

Standard “cup first” THA navigation does not improve mid-term functional outcome, bony ingrowth and/or polyethylene wear. New concepts in computer-assisted THA, considering cup and stem as coupled biomechanical partners are needed to justify the effort of navigation in routine operations.
Literatur
1.
Zurück zum Zitat Anderson Engh C, Sychters C, Charles E (1999) Factors affecting femoral bone remodeling after cementless total hip arthroplasty. J Arthroplasty 14:637–644CrossRef Anderson Engh C, Sychters C, Charles E (1999) Factors affecting femoral bone remodeling after cementless total hip arthroplasty. J Arthroplasty 14:637–644CrossRef
2.
Zurück zum Zitat Brown ML, Reed JD, Drinkwater CJ (2014) Imageless computer-assisted versus conventional total hip arthroplasty: one surgeon’s initial experience. J Arthroplasty 29:1015–1020CrossRefPubMed Brown ML, Reed JD, Drinkwater CJ (2014) Imageless computer-assisted versus conventional total hip arthroplasty: one surgeon’s initial experience. J Arthroplasty 29:1015–1020CrossRefPubMed
4.
Zurück zum Zitat DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop 121:20–32PubMed DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop 121:20–32PubMed
5.
Zurück zum Zitat Dorr LD, Malik A, Wan Z, Long WT, Harris M (2007) Precision and bias of imageless computer navigation and surgeon estimates for acetabular component position. Clin Orthop 465:92–99PubMed Dorr LD, Malik A, Wan Z, Long WT, Harris M (2007) Precision and bias of imageless computer navigation and surgeon estimates for acetabular component position. Clin Orthop 465:92–99PubMed
6.
Zurück zum Zitat Dorr LD, Wan Z, Malik A, Zhu J, Dastane M, Deshmane P (2009) A comparison of surgeon estimation and computed tomographic measurement of femoral component anteversion in cementless total hip arthroplasty. J Bone Joint Surg Am 91:2598–2604CrossRefPubMed Dorr LD, Wan Z, Malik A, Zhu J, Dastane M, Deshmane P (2009) A comparison of surgeon estimation and computed tomographic measurement of femoral component anteversion in cementless total hip arthroplasty. J Bone Joint Surg Am 91:2598–2604CrossRefPubMed
7.
Zurück zum Zitat Engh C, Bobyn J, Glassman A (1987) Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg Br 69-B:45–55 Engh C, Bobyn J, Glassman A (1987) Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg Br 69-B:45–55
8.
Zurück zum Zitat Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 141:17–27PubMed Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 141:17–27PubMed
9.
Zurück zum Zitat Hallan G, Lie SA, Furnes O, Engesaeter LB, Vollset SE, Havelin LI (2007) Medium- and long-term performance of 11 516 uncemented primary femoral stems from the Norwegian arthroplasty register. J Bone Joint Surg Br 89-B:1574–1580CrossRef Hallan G, Lie SA, Furnes O, Engesaeter LB, Vollset SE, Havelin LI (2007) Medium- and long-term performance of 11 516 uncemented primary femoral stems from the Norwegian arthroplasty register. J Bone Joint Surg Br 89-B:1574–1580CrossRef
10.
Zurück zum Zitat Harris WH (1969) Traumatic Arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty an end—result study using a new method of result evaluation. J Bone Joint Surg 51:737–755PubMed Harris WH (1969) Traumatic Arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty an end—result study using a new method of result evaluation. J Bone Joint Surg 51:737–755PubMed
11.
Zurück zum Zitat Hayaishi Y, Miki H, Nishii T, Hananouchi T, Yoshikawa H, Sugano N (2007) Proximal femoral bone mineral density after resurfacing total hip arthroplasty and after standard stem-type cementless total hip arthroplasty, both having similar neck preservation and the same articulation type. J Arthroplasty 22:1208–1213CrossRefPubMed Hayaishi Y, Miki H, Nishii T, Hananouchi T, Yoshikawa H, Sugano N (2007) Proximal femoral bone mineral density after resurfacing total hip arthroplasty and after standard stem-type cementless total hip arthroplasty, both having similar neck preservation and the same articulation type. J Arthroplasty 22:1208–1213CrossRefPubMed
12.
Zurück zum Zitat Hodgkinson JP, Shelley P, Wroblewski BM (1988) The correlation between the roentgenographic appearance and operative findings at the bone-cement junction of the socket in Charnley low friction arthroplasties. Clin Orthop 228:105PubMed Hodgkinson JP, Shelley P, Wroblewski BM (1988) The correlation between the roentgenographic appearance and operative findings at the bone-cement junction of the socket in Charnley low friction arthroplasties. Clin Orthop 228:105PubMed
13.
Zurück zum Zitat Hui AJ, McCalden RW, Martell JM, MacDonald SJ, Bourne RB, Rorabeck CH (2003) Validation of two and three-dimensional radiographic techniques for measuring polyethylene wear after total hip arthroplasty. J Bone Joint Surg 85:505–511PubMed Hui AJ, McCalden RW, Martell JM, MacDonald SJ, Bourne RB, Rorabeck CH (2003) Validation of two and three-dimensional radiographic techniques for measuring polyethylene wear after total hip arthroplasty. J Bone Joint Surg 85:505–511PubMed
14.
Zurück zum Zitat Karachalios T, Tsatsaronis C, Efraimis G, Papadelis P, Lyritis G, Diakoumopoulos G (2004) The long-term clinical relevance of calcar atrophy caused by stress shielding in total hip arthroplasty: a 10-year, prospective, randomized study. J Arthroplasty 19:469–475 (No benefits or funds were received in support of this study)CrossRefPubMed Karachalios T, Tsatsaronis C, Efraimis G, Papadelis P, Lyritis G, Diakoumopoulos G (2004) The long-term clinical relevance of calcar atrophy caused by stress shielding in total hip arthroplasty: a 10-year, prospective, randomized study. J Arthroplasty 19:469–475 (No benefits or funds were received in support of this study)CrossRefPubMed
15.
Zurück zum Zitat Lass R, Kubista B, Olischar B, Frantal S, Windhager R, Giurea A (2014) Total hip arthroplasty using imageless computer-assisted hip navigation: a prospective randomized study. J Arthroplasty 29:786–791CrossRefPubMed Lass R, Kubista B, Olischar B, Frantal S, Windhager R, Giurea A (2014) Total hip arthroplasty using imageless computer-assisted hip navigation: a prospective randomized study. J Arthroplasty 29:786–791CrossRefPubMed
16.
Zurück zum Zitat Lecerf G, Fessy MH, Philippot R, Massin P, Giraud F, Flecher X, Girard J, Mertl P, Marchetti E, Stindel E (2009) Femoral offset: anatomical concept, definition, assessment, implications for preoperative templating and hip arthroplasty. Orthop Traumatol Surg Res 95:210–219CrossRefPubMed Lecerf G, Fessy MH, Philippot R, Massin P, Giraud F, Flecher X, Girard J, Mertl P, Marchetti E, Stindel E (2009) Femoral offset: anatomical concept, definition, assessment, implications for preoperative templating and hip arthroplasty. Orthop Traumatol Surg Res 95:210–219CrossRefPubMed
17.
Zurück zum Zitat Lewinnek G, Lewis J, Tarr R, Compere C, Zimmerman J (1978) Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg 60:217–220PubMed Lewinnek G, Lewis J, Tarr R, Compere C, Zimmerman J (1978) Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg 60:217–220PubMed
18.
Zurück zum Zitat Licini DJ, Burnikel DJ, Meneghini RM, Ochsner JL (2013) Comparison of limb-length discrepancy after THA: with and without computer navigation. Orthopedics 36:e543–e547CrossRefPubMed Licini DJ, Burnikel DJ, Meneghini RM, Ochsner JL (2013) Comparison of limb-length discrepancy after THA: with and without computer navigation. Orthopedics 36:e543–e547CrossRefPubMed
19.
Zurück zum Zitat Malik A, Maheshwari A, Dorr LD (2007) Impingement with total hip replacement. J Bone Joint Surg 89:1832–1842CrossRefPubMed Malik A, Maheshwari A, Dorr LD (2007) Impingement with total hip replacement. J Bone Joint Surg 89:1832–1842CrossRefPubMed
20.
Zurück zum Zitat Marchetti P, Binazzi R, Vaccari V, Girolami M, Morici F, Impallomeni C, Commessatti M, Silvello L (2005) Long-term results with cementless fitek (or fitmore) cups. J Arthroplasty 20:730–737CrossRefPubMed Marchetti P, Binazzi R, Vaccari V, Girolami M, Morici F, Impallomeni C, Commessatti M, Silvello L (2005) Long-term results with cementless fitek (or fitmore) cups. J Arthroplasty 20:730–737CrossRefPubMed
21.
Zurück zum Zitat Martell JM, Berdia S (1997) Determination of polyethylene wear in total hip replacements with use of digital radiographs. JBone Joint Surg 79:1635–1641 Martell JM, Berdia S (1997) Determination of polyethylene wear in total hip replacements with use of digital radiographs. JBone Joint Surg 79:1635–1641
22.
Zurück zum Zitat Moskal JT, Capps SG (2011) Acetabular component positioning in total hip arthroplasty: an evidence-based analysis. J Arthroplasty 26:1432–1437CrossRefPubMed Moskal JT, Capps SG (2011) Acetabular component positioning in total hip arthroplasty: an evidence-based analysis. J Arthroplasty 26:1432–1437CrossRefPubMed
23.
Zurück zum Zitat Murray D (1993) The definition and measurement of acetabular orientation. J. Bone Joint Surg Br 75-B:228–232 Murray D (1993) The definition and measurement of acetabular orientation. J. Bone Joint Surg Br 75-B:228–232
24.
Zurück zum Zitat Nilsdotter A, Lohmander LS, Klassbo M, Roos E (2003) Hip disability and osteoarthritis outcome score (HOOS)—validity and responsiveness in total hip replacement. BMC Musculoskelet Disord 4:10CrossRefPubMedCentralPubMed Nilsdotter A, Lohmander LS, Klassbo M, Roos E (2003) Hip disability and osteoarthritis outcome score (HOOS)—validity and responsiveness in total hip replacement. BMC Musculoskelet Disord 4:10CrossRefPubMedCentralPubMed
25.
Zurück zum Zitat Okano T, Hagino H, Otsuka T, Teshima R, Yamamoto K, Hirano Y, Nakamura K (2002) Measurement of periprosthetic bone mineral density by dual-energy X-ray absorptiometry is useful for estimating fixation between the bone and the prosthesis in an early stage. J Arthroplasty 17:49–55CrossRefPubMed Okano T, Hagino H, Otsuka T, Teshima R, Yamamoto K, Hirano Y, Nakamura K (2002) Measurement of periprosthetic bone mineral density by dual-energy X-ray absorptiometry is useful for estimating fixation between the bone and the prosthesis in an early stage. J Arthroplasty 17:49–55CrossRefPubMed
26.
Zurück zum Zitat Penny JO, Brixen K, Varmarken JE, Ovesen O, Overgaard S (2012) Changes in bone mineral density of the acetabulum, femoral neck and femoral shaft, after hip resurfacing and total hip replacement: 2-year results from a randomised study. J. Bone Joint Surg. Br. 94-B:1036–1044CrossRef Penny JO, Brixen K, Varmarken JE, Ovesen O, Overgaard S (2012) Changes in bone mineral density of the acetabulum, femoral neck and femoral shaft, after hip resurfacing and total hip replacement: 2-year results from a randomised study. J. Bone Joint Surg. Br. 94-B:1036–1044CrossRef
27.
Zurück zum Zitat Rahmy AIA, Gosens T, Blake GM, Tonino A, Fogelman I (2004) Periprosthetic bone remodelling of two types of uncemented femoral implant with proximal hydroxyapatite coating: a 3-year follow-up study addressing the influence of prosthesis design and preoperative bone density on periprosthetic bone loss. Osteoporos Int 15:281–289CrossRefPubMed Rahmy AIA, Gosens T, Blake GM, Tonino A, Fogelman I (2004) Periprosthetic bone remodelling of two types of uncemented femoral implant with proximal hydroxyapatite coating: a 3-year follow-up study addressing the influence of prosthesis design and preoperative bone density on periprosthetic bone loss. Osteoporos Int 15:281–289CrossRefPubMed
28.
Zurück zum Zitat Renkawitz T, Tingart M, Grifka J, Sendtner E, Kalteis T (2009) Computer-assisted total hip arthroplasty: coding the next generation of navigation systems for orthopedic surgery. Expert Rev Med Devices 6:507–514CrossRefPubMed Renkawitz T, Tingart M, Grifka J, Sendtner E, Kalteis T (2009) Computer-assisted total hip arthroplasty: coding the next generation of navigation systems for orthopedic surgery. Expert Rev Med Devices 6:507–514CrossRefPubMed
29.
Zurück zum Zitat Rubin P, Leyvraz P, Aubaniac J, Argenson J, Esteve P, De Roguin B (1992) The morphology of the proximal femur. A three-dimensional radiographic analysis. J Bone Joint Surg Br 74:28–32PubMed Rubin P, Leyvraz P, Aubaniac J, Argenson J, Esteve P, De Roguin B (1992) The morphology of the proximal femur. A three-dimensional radiographic analysis. J Bone Joint Surg Br 74:28–32PubMed
30.
31.
Zurück zum Zitat Sabo D, Reiter A, Simank HG, Thomsen M, Lukoschek M, Ewerbeck V (1998) Periprosthetic mineralization around cementless total hip endoprosthesis: longitudinal study and cross-sectional study on titanium threaded acetabular cup and cementless spotorno stem with DEXA. Calcif Tissue Int 62:177–182CrossRefPubMed Sabo D, Reiter A, Simank HG, Thomsen M, Lukoschek M, Ewerbeck V (1998) Periprosthetic mineralization around cementless total hip endoprosthesis: longitudinal study and cross-sectional study on titanium threaded acetabular cup and cementless spotorno stem with DEXA. Calcif Tissue Int 62:177–182CrossRefPubMed
32.
Zurück zum Zitat Sato T, Nakashima Y, Akiyama M, Yamamoto T, Mawatari T, Itokawa T, Ohishi M, Motomura G, Hirata M, Iwamoto Y (2012) Wear resistant performance of highly cross-linked and annealed ultra-high molecular weight polyethylene against ceramic heads in total hip arthroplasty. J Orthop Res 30:2031–2037CrossRefPubMed Sato T, Nakashima Y, Akiyama M, Yamamoto T, Mawatari T, Itokawa T, Ohishi M, Motomura G, Hirata M, Iwamoto Y (2012) Wear resistant performance of highly cross-linked and annealed ultra-high molecular weight polyethylene against ceramic heads in total hip arthroplasty. J Orthop Res 30:2031–2037CrossRefPubMed
33.
Zurück zum Zitat Schröter S, Ihle C, Mueller J, Lobenhoffer P, Stöckle U, van Heerwaarden R (2013) Digital planning of high tibial osteotomy. Interrater reliability by using two different software. Knee Surg Sports Traumatol Arthrosc 21:189–196CrossRefPubMed Schröter S, Ihle C, Mueller J, Lobenhoffer P, Stöckle U, van Heerwaarden R (2013) Digital planning of high tibial osteotomy. Interrater reliability by using two different software. Knee Surg Sports Traumatol Arthrosc 21:189–196CrossRefPubMed
34.
Zurück zum Zitat Sendtner E, Müller M, Winkler R, Wörner M, Grifka J, Renkawitz T (2010) Femur first in hip arthroplasty–the concept of combined anteversion. Z Orthopadie Unfallchirurgie 148:185–190 Sendtner E, Müller M, Winkler R, Wörner M, Grifka J, Renkawitz T (2010) Femur first in hip arthroplasty–the concept of combined anteversion. Z Orthopadie Unfallchirurgie 148:185–190
35.
Zurück zum Zitat Sendtner E, Schuster T, Wörner M, Kalteis T, Grifka J, Renkawitz T (2011) Accuracy of acetabular cup placement in computer-assisted, minimally-invasive THR in a lateral decubitus position. Int Orthop 35:809–815CrossRefPubMedCentralPubMed Sendtner E, Schuster T, Wörner M, Kalteis T, Grifka J, Renkawitz T (2011) Accuracy of acetabular cup placement in computer-assisted, minimally-invasive THR in a lateral decubitus position. Int Orthop 35:809–815CrossRefPubMedCentralPubMed
36.
37.
Zurück zum Zitat Sugano N, Nishii T, Miki H, Yoshikawa H, Sato Y, Tamura S (2007) Mid-term results of cementless total hip replacement using a ceramic-on-ceramic bearing with and without computer navigation. J Bone Joint Surg Br 89-B:455–460CrossRef Sugano N, Nishii T, Miki H, Yoshikawa H, Sato Y, Tamura S (2007) Mid-term results of cementless total hip replacement using a ceramic-on-ceramic bearing with and without computer navigation. J Bone Joint Surg Br 89-B:455–460CrossRef
38.
Zurück zum Zitat Trevisan C, Bigoni M, Cherubini R, Steiger P, Randelli G, Ortolani S (1993) Dual X-ray absorptiometry for the evaluation of bone density from the proximal femur after total hip arthroplasty: analysis protocols and reproducibility. Calcif Tissue Int 53:158–161CrossRefPubMed Trevisan C, Bigoni M, Cherubini R, Steiger P, Randelli G, Ortolani S (1993) Dual X-ray absorptiometry for the evaluation of bone density from the proximal femur after total hip arthroplasty: analysis protocols and reproducibility. Calcif Tissue Int 53:158–161CrossRefPubMed
39.
Zurück zum Zitat Varghese B, Muthukumar N, Balasubramaniam M (2011) Reliability of measurements with digital radiographs—a myth. Acta Orthop Belg 77:622PubMed Varghese B, Muthukumar N, Balasubramaniam M (2011) Reliability of measurements with digital radiographs—a myth. Acta Orthop Belg 77:622PubMed
40.
Zurück zum Zitat Venesmaa PK, Kröger HPJ, Miettinen HJA, Jurvelin JS, Suomalainen OT, Alhava EM (2001) Monitoring of periprosthetic BMD after uncemented total hip arthroplasty with dual-energy X-ray absorptiometry—a 3-year follow-up study. J Bone Miner Res 16:1056–1061CrossRefPubMed Venesmaa PK, Kröger HPJ, Miettinen HJA, Jurvelin JS, Suomalainen OT, Alhava EM (2001) Monitoring of periprosthetic BMD after uncemented total hip arthroplasty with dual-energy X-ray absorptiometry—a 3-year follow-up study. J Bone Miner Res 16:1056–1061CrossRefPubMed
41.
Zurück zum Zitat Westacott DJ, McArthur J, King RJ, Foguet P (2013) Assessment of cup orientation in hip resurfacing: a comparison of TraumaCad and computed tomography. J Orthop Surg Res 8:8CrossRefPubMedCentralPubMed Westacott DJ, McArthur J, King RJ, Foguet P (2013) Assessment of cup orientation in hip resurfacing: a comparison of TraumaCad and computed tomography. J Orthop Surg Res 8:8CrossRefPubMedCentralPubMed
Metadaten
Titel
No difference in clinical outcome, bone density and polyethylene wear 5–7 years after standard navigated vs. conventional cementfree total hip arthroplasty
verfasst von
Armin Keshmiri
Christoph Schröter
Markus Weber
Benjamin Craiovan
Joachim Grifka
Tobias Renkawitz
Publikationsdatum
01.05.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 5/2015
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-015-2201-2

Weitere Artikel der Ausgabe 5/2015

Archives of Orthopaedic and Trauma Surgery 5/2015 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.