Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 10/2016

30.07.2016 | Handsurgery

Evaluation of biomechanical properties: are porcine flexor tendons and bovine extensor tendons eligible surrogates for human tendons in in vitro studies?

verfasst von: C. Domnick, B. Wieskötter, M. J. Raschke, M. Schulze, D. Kronenberg, M. Wefelmeier, M. F. Langer, M. Herbort

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 10/2016

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Porcine flexor tendons, bovine extensor tendons, and human (semitendinosus) tendons are frequently used as substitutes for human ACL grafts in biomechanical in vitro studies. This study compares the biomechanical properties and structural differences of these tendons.

Materials and methods

In this biomechanical study, fresh-frozen porcine flexor tendons, bovine extensor tendons, and human semitendinosus tendons were used (n = 36). The tendons were mounted in a uniaxial testing machine (Zwick/Roell) with cryo-clamps, leaving a 60 mm tendon part free between the two clamps. Specimens have been loaded to failure to evaluate the biomechanical parameters stiffness, yield load, and maximum load. A Total Collagen Assay Kit was used to detect differences in the total collagen type I concentration (n = 30). A one-way ANOVA was performed to detect differences in the means. The significance level was set at p < 0.05.

Results

There were no significant differences in the stiffness between the groups (bovine 194 ± 43 N/mm, porcine 211 ± 63 N/mm, and human cadaveric 208 ± 58 N/mm). The yield and maximum loads were high (>1000 N) in all groups, but they were significantly increased in both animal specimens (means of 1681–1795 N) compared with human cadaveric specimen (means of 1289–1406 N; p < 0.01). No difference in the collagen type I concentration was detected (N.S.).

Conclusion

Porcine flexor and bovine extensor tendons are eligible substitutes with similar stiffness and high failure loads compared with human cadaveric semitendinosus tendons in in vitro studies.
Literatur
1.
Zurück zum Zitat Magen HE, Howell SM, Hull ML (1999) Structural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts. Am J Sports Med 27:35–43PubMed Magen HE, Howell SM, Hull ML (1999) Structural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts. Am J Sports Med 27:35–43PubMed
2.
4.
Zurück zum Zitat Omar M, Petri M, Dratzidis A, El Nehmer S (2014) Biomechanical comparison of fixation techniques for medial collateral ligament anatomical augmented repair. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-014-3326-5 PubMed Omar M, Petri M, Dratzidis A, El Nehmer S (2014) Biomechanical comparison of fixation techniques for medial collateral ligament anatomical augmented repair. Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-014-3326-5 PubMed
5.
6.
Zurück zum Zitat Shin S-J, Campbell S, Scott J et al (2014) Simultaneous anatomic reconstruction of the acromioclavicular and coracoclavicular ligaments using a single tendon graft. Knee Surg Sports Traumatol Arthrosc 22:2216–2222. doi:10.1007/s00167-013-2569-x CrossRefPubMed Shin S-J, Campbell S, Scott J et al (2014) Simultaneous anatomic reconstruction of the acromioclavicular and coracoclavicular ligaments using a single tendon graft. Knee Surg Sports Traumatol Arthrosc 22:2216–2222. doi:10.​1007/​s00167-013-2569-x CrossRefPubMed
7.
Zurück zum Zitat Lorbach O, Kieb M, Domnick C et al (2014) Biomechanical evaluation of knee kinematics after anatomic single- and anatomic double-bundle ACL reconstructions with medial meniscal repair. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-014-3071-9 Lorbach O, Kieb M, Domnick C et al (2014) Biomechanical evaluation of knee kinematics after anatomic single- and anatomic double-bundle ACL reconstructions with medial meniscal repair. Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-014-3071-9
8.
Zurück zum Zitat Miyata K, Yasuda K, Kondo E et al (2000) Biomechanical comparisons of anterior cruciate ligament: reconstruction procedures with flexor tendon graft. J Orthop Sci 5:585–592CrossRefPubMed Miyata K, Yasuda K, Kondo E et al (2000) Biomechanical comparisons of anterior cruciate ligament: reconstruction procedures with flexor tendon graft. J Orthop Sci 5:585–592CrossRefPubMed
10.
11.
Zurück zum Zitat Nurmi JT, Sievänen H, Kannus P et al (2004) Porcine tibia is a poor substitute for human cadaver tibia for evaluating interference screw fixation. Am J Sports Med 32:765–771CrossRefPubMed Nurmi JT, Sievänen H, Kannus P et al (2004) Porcine tibia is a poor substitute for human cadaver tibia for evaluating interference screw fixation. Am J Sports Med 32:765–771CrossRefPubMed
13.
Zurück zum Zitat Janjic N, Ninkovic S, Harhaji V et al (2013) Biomechanical Properties of Porcine Tendon. The PSU-UNS International Conference on Engineering and Technology ICET Janjic N, Ninkovic S, Harhaji V et al (2013) Biomechanical Properties of Porcine Tendon. The PSU-UNS International Conference on Engineering and Technology ICET
15.
Zurück zum Zitat Omar M, Dratzidis A, Klintschar M et al (2016) Are porcine flexor digitorum profundus tendons suitable graft substitutes for human hamstring tendons in biomechanical in vitro-studies? Arch Orthop Trauma Surg 136:681–686. doi:10.1007/s00402-016-2425-9 CrossRefPubMed Omar M, Dratzidis A, Klintschar M et al (2016) Are porcine flexor digitorum profundus tendons suitable graft substitutes for human hamstring tendons in biomechanical in vitro-studies? Arch Orthop Trauma Surg 136:681–686. doi:10.​1007/​s00402-016-2425-9 CrossRefPubMed
16.
Zurück zum Zitat Donahue TL, Gregersen C, Hull ML, Howell SM (2001) Comparison of viscoelastic, structural, and material properties of double-looped anterior cruciate ligament grafts made from bovine digital extensor and human hamstring tendons. J Biomech Eng 123:162–169CrossRefPubMed Donahue TL, Gregersen C, Hull ML, Howell SM (2001) Comparison of viscoelastic, structural, and material properties of double-looped anterior cruciate ligament grafts made from bovine digital extensor and human hamstring tendons. J Biomech Eng 123:162–169CrossRefPubMed
17.
Zurück zum Zitat Pichler W, Tesch NP, Schwantzer G et al (2008) Differences in length and cross-section of semitendinosus and gracilis tendons and their effect on anterior cruciate ligament reconstruction: a cadaver study. J Bone Joint Surg Br 90:516–519. doi:10.1302/0301-620X.90B4.19994 CrossRefPubMed Pichler W, Tesch NP, Schwantzer G et al (2008) Differences in length and cross-section of semitendinosus and gracilis tendons and their effect on anterior cruciate ligament reconstruction: a cadaver study. J Bone Joint Surg Br 90:516–519. doi:10.​1302/​0301-620X.​90B4.​19994 CrossRefPubMed
18.
Zurück zum Zitat Herbort M, Hoser C, Domnick C et al (2014) MPFL reconstruction using a quadriceps tendon graft: part 1: biomechanical properties of quadriceps tendon MPFL reconstruction in comparison to the Intact MPFL. A human cadaveric study. Knee 21:1169–1174. doi:10.1016/j.knee.2014.07.026 CrossRefPubMed Herbort M, Hoser C, Domnick C et al (2014) MPFL reconstruction using a quadriceps tendon graft: part 1: biomechanical properties of quadriceps tendon MPFL reconstruction in comparison to the Intact MPFL. A human cadaveric study. Knee 21:1169–1174. doi:10.​1016/​j.​knee.​2014.​07.​026 CrossRefPubMed
19.
20.
Zurück zum Zitat Domnick C, Herbort M, Raschke MJ et al (2015) Converting round tendons to flat tendon constructs: does the preparation process have an influence on the structural properties? Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-015-3749-7 Domnick C, Herbort M, Raschke MJ et al (2015) Converting round tendons to flat tendon constructs: does the preparation process have an influence on the structural properties? Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-015-3749-7
23.
Zurück zum Zitat Faul F, Erdfelder E, Lang A-G, Buchner A (2007) G*Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods 39:175–191CrossRefPubMed Faul F, Erdfelder E, Lang A-G, Buchner A (2007) G*Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods 39:175–191CrossRefPubMed
25.
Zurück zum Zitat Gan Y, Xu D, Ding J, Xu Y (2012) Tension band wire fixation for anterior cruciate ligament avulsion fracture: biomechanical comparison of four fixation techniques. Knee Surg Sports Traumatol Arthrosc 20:909–915. doi:10.1007/s00167-011-1649-z CrossRefPubMed Gan Y, Xu D, Ding J, Xu Y (2012) Tension band wire fixation for anterior cruciate ligament avulsion fracture: biomechanical comparison of four fixation techniques. Knee Surg Sports Traumatol Arthrosc 20:909–915. doi:10.​1007/​s00167-011-1649-z CrossRefPubMed
26.
Zurück zum Zitat Hamner DL, Brown CH, Steiner ME et al (1999) Hamstring tendon grafts for reconstruction of the anterior cruciate ligament: biomechanical evaluation of the use of multiple strands and tensioning techniques. J Bone Joint Surg 81:549–557. doi:10.4103/2277-9175.98566 PubMed Hamner DL, Brown CH, Steiner ME et al (1999) Hamstring tendon grafts for reconstruction of the anterior cruciate ligament: biomechanical evaluation of the use of multiple strands and tensioning techniques. J Bone Joint Surg 81:549–557. doi:10.​4103/​2277-9175.​98566 PubMed
27.
Zurück zum Zitat Woo SL, Hollis JM, Adams DJ et al (1991) Tensile properties of the human femur-anterior cruciate ligament-tibia complex. The effects of specimen age and orientation. Am J Sports Med 19:217–225CrossRefPubMed Woo SL, Hollis JM, Adams DJ et al (1991) Tensile properties of the human femur-anterior cruciate ligament-tibia complex. The effects of specimen age and orientation. Am J Sports Med 19:217–225CrossRefPubMed
28.
Zurück zum Zitat Brand JJ, Weiler A, Caborn DN et al (2000) Graft fixation in cruciate ligament reconstruction. Am J Sports Med 28:761–774PubMed Brand JJ, Weiler A, Caborn DN et al (2000) Graft fixation in cruciate ligament reconstruction. Am J Sports Med 28:761–774PubMed
29.
Zurück zum Zitat Kousa P, Järvinen TL, Kannus P, Jarvinen M (2001) Initial fixation strength of bioabsorbable and titanium interference screws in anterior cruciate ligament reconstruction. Biomechanical evaluation by single cycle and cyclic loading. Am J Sports Med 29:420–425PubMed Kousa P, Järvinen TL, Kannus P, Jarvinen M (2001) Initial fixation strength of bioabsorbable and titanium interference screws in anterior cruciate ligament reconstruction. Biomechanical evaluation by single cycle and cyclic loading. Am J Sports Med 29:420–425PubMed
30.
Zurück zum Zitat Kousa P, Järvinen TLN, Vihavainen M et al (2003) The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction. Part I: femoral site. Am J Sports Med 31:174–181PubMed Kousa P, Järvinen TLN, Vihavainen M et al (2003) The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction. Part I: femoral site. Am J Sports Med 31:174–181PubMed
31.
Zurück zum Zitat Herbort M, Tecklenburg K, Zantop T et al (2013) Single-bundle anterior cruciate ligament reconstruction: a biomechanical cadaveric study of a rectangular quadriceps and bone–patellar tendon–bone graft configuration versus a round hamstring graft. Arthroscopy 29:1981–1990. doi:10.1016/j.arthro.2013.08.030 CrossRefPubMed Herbort M, Tecklenburg K, Zantop T et al (2013) Single-bundle anterior cruciate ligament reconstruction: a biomechanical cadaveric study of a rectangular quadriceps and bone–patellar tendon–bone graft configuration versus a round hamstring graft. Arthroscopy 29:1981–1990. doi:10.​1016/​j.​arthro.​2013.​08.​030 CrossRefPubMed
32.
Zurück zum Zitat Aerssens J, Boonen S, Lowet G, Dequeker J (1998) Interspecies differences in bone composition, density, and quality: potential implications for in vivo bone research. Endocrinology 139:663–670. doi:10.1210/endo.139.2.5751 PubMed Aerssens J, Boonen S, Lowet G, Dequeker J (1998) Interspecies differences in bone composition, density, and quality: potential implications for in vivo bone research. Endocrinology 139:663–670. doi:10.​1210/​endo.​139.​2.​5751 PubMed
34.
Zurück zum Zitat Fujii K, Yamagishi T, Nagafuchi T et al (1994) Biochemical properties of collagen from ligaments and periarticular tendons of the human knee. Knee Surg Sports Traumatol Arthrosc 2:229–233. doi:10.1007/BF01845593 CrossRefPubMed Fujii K, Yamagishi T, Nagafuchi T et al (1994) Biochemical properties of collagen from ligaments and periarticular tendons of the human knee. Knee Surg Sports Traumatol Arthrosc 2:229–233. doi:10.​1007/​BF01845593 CrossRefPubMed
Metadaten
Titel
Evaluation of biomechanical properties: are porcine flexor tendons and bovine extensor tendons eligible surrogates for human tendons in in vitro studies?
verfasst von
C. Domnick
B. Wieskötter
M. J. Raschke
M. Schulze
D. Kronenberg
M. Wefelmeier
M. F. Langer
M. Herbort
Publikationsdatum
30.07.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 10/2016
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-016-2529-2

Weitere Artikel der Ausgabe 10/2016

Archives of Orthopaedic and Trauma Surgery 10/2016 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.