Skip to main content
Erschienen in: Archives of Dermatological Research 1/2016

Open Access 01.01.2016 | Original Paper

In vivo assessment of optical properties of melanocytic skin lesions and differentiation of melanoma from non-malignant lesions by high-definition optical coherence tomography

verfasst von: M. A. L. M. Boone, M. Suppa, F. Dhaenens, M. Miyamoto, A. Marneffe, G. B. E. Jemec, V. Del Marmol, R. Nebosis

Erschienen in: Archives of Dermatological Research | Ausgabe 1/2016

Abstract

One of the most challenging problems in clinical dermatology is the early detection of melanoma. Reflectance confocal microscopy (RCM) is an added tool to dermoscopy improving considerably diagnostic accuracy. However, diagnosis strongly depends on the experience of physicians. High-definition optical coherence tomography (HD-OCT) appears to offer additional structural and cellular information on melanocytic lesions complementary to that of RCM. However, the diagnostic potential of HD-OCT seems to be not high enough for ruling out the diagnosis of melanoma if based on morphology analysis. The aim of this paper is first to quantify in vivo optical properties such as light attenuation in melanocytic lesions by HD-OCT. The second objective is to determine the best critical value of these optical properties for melanoma diagnosis. The technique of semi-log plot whereby an exponential function becomes a straight line has been implemented on HD-OCT signals coming from four successive skin layers (epidermis, upper papillary dermis, deeper papillary dermis and superficial reticular dermis). This permitted the HD-OCT in vivo measurement of skin entrance signal (SES), relative attenuation factor normalized for the skin entrance signal (µ raf1) and half value layer (z 1/2). The diagnostic accuracy of HD-OCT for melanoma detection based on the optical properties, µ raf1 , SES and z 1/2 was high (95.6, 82.2 and 88.9 %, respectively). High negative predictive values could be found for these optical properties (96.7, 89.3 and 96.3 %, respectively) compared to morphologic assessment alone (89.9 %), reducing the risk of mistreating a malignant lesion to a more acceptable level (3.3 % instead of 11.1 %). HD-OCT seems to enable the combination of in vivo morphological analysis of cellular and 3-D micro-architectural structures with in vivo analysis of optical properties of tissue scatterers in melanocytic lesions. In vivo HD-OCT analysis of optical properties permits melanoma diagnosis with higher accuracy than in vivo HD-OCT analysis of morphology alone.

Introduction

One of the most challenging problems in clinical dermatology is the early detection of melanoma [4, 42, 46]. Since clinical diagnosis may be difficult, non-invasive imaging techniques have been developed to enhance early diagnosis in challenging cases [10, 17]. Dermoscopy and reflectance confocal microscopy (RCM) are both able to considerably improve the diagnostic accuracy for melanoma, especially when used synergistically [11, 32, 33, 48]. However, diagnosis strongly depends on the experience of physicians [2, 31].
New diagnostic tools providing automated classification of pigmented skin lesions usable by non-experts have been proposed [23]. Spectral methods fall into this class of emerging new techniques holding the promise to provide quantitative criteria for melanoma diagnosis and to improve early diagnosis [37]. Multispectral information can be assessed both in the spatial domain (multispectral digital dermoscopy [22]) or in the frequency domain (spectroscopic methods such as diffuse-reflectance spectroscopy [21, 41, 54], Raman spectroscopy [36, 52] and fluorescence spectroscopy [15, 34]).
These methods evaluate the colour of a lesion by measuring its reflectance as a function of the wavelength. A comprehensive analysis of pigmented lesions under both ultraviolet and infrared radiations has previously been described in 1976 [37]. It was stated that infrared photographs tends to discriminate the different types of melanocytic lesions, with melanoma showing a relatively high degree of correlation with low infrared reflectance [37].
RCM and optical coherence tomography (OCT) are both technologies operating in the near-infrared (NIR) optical window. Conventional OCT enables the non-invasive imaging of structures with a non-cellular resolution (7.5–15 µm) up to a depth of about 1 mm, while high-definition OCT (HD-OCT) provides cellular (3 µm) resolution up to a depth of 570 µm [3, 5, 6, 8, 18, 19, 25, 44]. Conventional OCT has been used for non-invasive tumour thickness measurement in melanocytic skin lesions. A variable correlation with histopathology could be observed depending on OCT technology used [24, 38]. HD-OCT offers additional structural and cellular information on melanocytic lesions complementary to that of RCM [9]. However, the diagnostic potential of HD-OCT seems to be not high enough for ruling out the diagnosis of melanoma if based on morphology analysis [20].
In a recent study, it was demonstrated that HD-OCT permits to quantify the reflectance of NIR light in a volume of skin as function of depth [7]. Therefore, the aim of this paper was to quantify in vivo optical properties such as light attenuation in melanocytic lesions by HD-OCT. An additional objective was to determine the best critical value of these optical properties for melanoma diagnosis.

Methods

Study sample

The cases for this retrospective pilot study were retrieved from patient files collected at first author’s private practice between 2012 and 2015. The cases contain melanocytic lesions including benign nevi (BN), dysplastic nevi (DN) and melanomas (MM). The inclusion criteria were: (i) selection of clinically suspected melanocytic lesions for full excision based on dermoscopic or combined dermoscopic/RCM evaluation and subsequent histopathologic diagnosis and (ii) availability of relevant (see procedure) HD-OCT images taken prior to excision.
Approval from local ethical committee was obtained (P2015/301). All patients provided informed consent for imaging their lesion by HD-OCT (Skintell®, Agfa Healthcare, Mortsel, Belgium). We conformed to the Helsinki Declaration with respect to human subjects in biomedical research. All international rules governing clinical investigation of human subjects were strictly followed. This study affected neither the routine diagnosis nor the treatment of the lesions presented by the included subjects.

Histopathology

Histopathologic analysis was carried out by two board-certified histopathologists who classified each lesion according to histopathological criteria for melanocytic lesions described elsewhere [1214].

High-definition optical coherence tomography

Instruments and acquisition methods and technical details have been previously described [5, 9]. For the purpose of this study we will remind what follows.
HD-OCT has four basic design principles: (i) a time domain OCT providing depth information by the position of the reference mirror, (ii) full-field illumination by a light source enabling very low lateral coherence and permitting a high-speed 3-D sharp image acquisition, (iii) high-power tungsten lamp with Gaussian filter and ultrahigh bandwidth (1300 ± 100 nm). This permits high-depth resolution of 3 µm and (iv) full-field domain OCT system with dynamic focus tracking: the focal plane is continuously moved through the skin sample. This ensures a high lateral resolution over the entire depth of 3 µm. HD-OCT offers a constant homogeneous resolution of 3 µm in all three dimensions. The system is capable of capturing a cross-sectional and en face image in real time, as well as of fast real time 3-D acquisition. A sharp image at all depth is guaranteed up to a theoretical depth of 570 µm. The field of view is 1.8 × 1.5 mm. The total light power at the tissue is <3.5 mW.

HD-OCT focus tracking

Skin is a highly turbid medium. Light which propagates through skin is scattered and absorbed resulting in attenuation of this light. In contradiction to a “normal” light detector HD-OCT is only detecting photons which reach the detector on an almost straight path—the ballistic portion of the photons or photons which were only forward scattered a few times [49].
The resulting attenuation coefficient was estimated by Jacques et al. [2729]. Since absorption is much smaller than scattering for tissues in the near-infrared spectrum, absorption can be neglected [29]. HD-OCT operates in the second diagnostic window of the NIR spectrum [47] and hence the main attenuation mechanism for HD-OCT is scattering. Measuring tissue optical properties in vivo is only applicable to OCT when operating focus tracking mode which is the case for HD-OCT [27]. Table 1 provides definitions and abbreviations of optical properties adapted from the literature [27, 29, 30, 35, 49, 50].
Table 1
Definition of optical properties adapted from the literature [33, 35, 36, 3840]
Optical properties
Dimension
Definition
Lambert–Beer expression
Dimensionless
\(\frac{I(z)}{{I_{\text{o}} }} = e^{ - \mu z}\)
Light intensity I(z) after a path length z in medium with homogenous absorber without scattering. Permits calculation of attenuation coefficient
OCT signal
Dimensionless
Light intensity which is leaving the skin. First light penetrates into the skin and is attenuated on the path down—than light is backscattered/reflected at objects and travels back up to the surface (on the way up it is again attenuated). Finally the light leaves the skin. OCT is only detecting photons which reach the detector on an almost straight path—the ballistic portion of the photons
Jacques expression
Dimensionless
\(R\left( z \right) = \rho e^{ - \mu z}\)
Intensity of an OCT signal depends on the attenuation µ of light while penetrating and leaving the skin and on the backscatter strength ρ of the imaged object
Anisotropy of scatter g (0–1)
Dimensionless
Characterizes tissue scattering in terms of the relative forward versus backward direction of scatter. It determines the effectiveness of scattering after a single scattering event. Hence, it represents a measure of the amount of forward direction retained after a single scattering event
a(g)
if g 0.8 → 1, then an important (85 %) reduction in scattering is noticed.
Dimensionless
Describes the influence of anisotropy of scatter on light attenuation. Drops from 1 to 0 as g increases from 0 to 1. The factor a(g) has only a significant influence on attenuation for g values >0.8 which are typical for skin. The larger the scattering structures the larger g and the lower the tissue attenuation
G(g,NA)
Dimensionless
Optical geometrical factor. Equals 1.1 for HD-OCT and describes the average photon path length
Depends on the numerical aperture (NA) of the lens and the anisotropy of scatter g (see further)
Local backscatter strength ρ
if g 0.8 → 1, then only a small reduction (8 %) in backscattering is observed.
Dimensionless
\(\rho = \mu s Lf b(g,NA)\)
Whereby Lf corresponds to the coherence length of the OCT and is for HD-OCT 3 µm; b(g,NA) is the fraction (1 to 0) of scattered light that backscatters into the lens for detection. The higher the anisotropy of scatter g the lower b(g,NA)
Total attenuation coefficient
µm−1
µ = (µ s a(g) + µ a) 2 G(g,NA) if light source ≪1300 nm
µ = µ s a(g) 2 G(g,NA) if µ a ≪ µ s at 1300 nm
Absorption coefficient µ a
µm−1
The cross-sectional area (cm2) for absorption per unit of volume of medium (cm3) containing a uniform distribution of identical absorbers
Scattering coefficient µ s
µm−1
Describes the number of scattering events per µm in a medium containing a uniform distribution of identical scatterers at a concentration defined as a volume density νs
Reduced scattering coefficient µs
µm−1
Is related to the scattering coefficient as follows: µs = µ s (1 − g). This is the pertinent term for describing light transport when multiple scattering occurs as the anisotropy of scatter is taken into account
Mean free path mfp
µm
The inverse of scattering coefficient.
In the diffusion (scattering) process, the photons moving through the skin do so in a series of steps of random length and direction (i.e. random walk). Each step begins with a scattering event and is equally likely to be taken in any direction and ends with a next scattering event
Reduced mean free path mfp
 
The inverse of the reduced scattering coefficient. Distance between two isotropic scattering events
Tissue half value thickness z 1/2
µm
Depth value under the skin surface corresponding with half of the backscattering intensity measured at stratum corneum
Rayleigh scattering (Rayleigh limit)
 
Scattering due to tissue structures that are considerably smaller than the light wavelength.
This type of scattering occurs in all directions (isotropic scattering) but is peaked equally in the forward and backward directions.
This scattering is also wavelength dependent (varies as the inverse fourth power of the wavelength)
Mie scattering (Mie regime)
 
Scattering due to larger spherical particles with diameters on the order of light wavelengths or larger. The scattering takes place mainly in the forward direction (anisotropic scattering)
This scattering is less wavelength dependent (varies as 1/λ b with b ≥ 1)

Procedure (Figs. 1, 2, 3)

The selection of spots in melanocytic lesions imaged by HD-OCT was based on dermoscopic or combined dermoscopic/RCM evaluation. Subsequently the selected spots were marked with a plastic ring of 2 mm diameter. A 3-D HD-OCT DICOM (digital imaging and communication in medicine) image taken at the centre of this ring was selected. This DICOM file was then opened using ImageJ® software. A single square region of interest (ROI) in the en face view (green square) was selected in each melanocytic lesion based on the presence of relevant morphologic features as described in previous papers [9, 20]. To exclude obvious “artefacts” such as air bubbles or skin furrows, a square ROI was carefully chosen. The size of the ROI was set at least to 300 × 300 µm.
The obtained graph displayed the reflectance and attenuation of the ballistic photons [OCT signal: measured on the y-axis with arbitral units (AU)] versus imaging depth which was indicated on the x-axis (from 0 to 200 axial position of depth). In a next step, the offset corresponding to the mean signal within gel was removed from each OCT signal. The first peak corresponded to the skin entrance signal (SES). All the HD-OCT values will be divided by SES to normalize them to the SES. The natural logarithm ln(x) of those values will be taken. The slice numbers needed to be multiplied by factor 3 to correspond to the real depth in micron (from 0 to 600 µm).
The decay with imaging depth of reflectance (backscattered intensity) of ballistic photons is a process that can be well modelled by an exponential relationship [26, 29].
When operating in the NIR diagnostic window, absorption becomes negligible and the slope of the exponential attenuation is proportional to the reduced scattering coefficient µs. Analysis by semi-log plot (an exponential function becomes a straight line given by y = ax + b) of the exponential profile of light attenuation, can provide information on tissue scattering properties [26, 29].
Four successive layers (epidermis, upper papillary dermis, deeper papillary dermis and superficial reticular dermis) with clear exponential decay were identified and plotted. A straight line was fitted in each of the four layers (i = 1–4) resulting in equation of the type y i  = ax i  + b whereby a was proportional to the attenuation coefficient for each of the four layers given by µ = a/2.
Three optical properties were measured:
  • Relative attenuation factor normalized to skin entrance signal for each of the four layers (µ raf1-4; µm−1)
  • Skin entrance signal (SES; arbitrary unit)
  • z value under the skin surface at which the OCT signal equals half of the SES, half value layer (z 1/2; µm)

Statistical analysis

One-way analysis of variance (ANOVA) was used to compare means of three samples (BN,DN and MM) using the F distribution. Prior to the Anova test, Levene’s Test for “Equality of Variances” was performed. If the Levene’s test was positive (p < 0.05) then the variances in the different groups were different (the groups are not homogeneous) and a logarithmic transformation to the data has been performed. Moreover, Scheffé test was used for all pairwise comparisons.
The best critical value of all HD-OCT assessed optical properties was determined by applying the receiver operating characteristic curves (ROC curves). This is a graph displaying the relationship between the true-positive rate (on the vertical axis) and the false-positive rate (on the horizontal axis) (Table 2).
Table 2
In vivo HD-OCT measured values of optical properties of melanocytic lesions according to thee subgroups
Subject #
Relative attenuation factor µ raf1
Skin entrance signal SES
Half value layer z 1/2
Benign nevi
1
0.0437
406
7.07
2
0.0664
817
2.79
3
0.0248
505
8.18
4
0.0780
818
1.89
5
0.0593
847
1.84
6
0.0388
1101
3.03
7
0.0152
683
5.22
8
0.0766
1066
2.02
9
0.0520
935
6.86
10
0.0220
760
5.42
11
0.0502
889
3.31
12
0.0454
731
7.88
13
0.0254
515
6.21
14
0.0388
678
6.64
15
0.0438
723
3.39
Dysplastic nevi
1
0.0160
475
4.84
2
0.0357
721
3.16
3
0.0407
716
4.80
4
0.0158
549
6.05
5
0.0166
731
6.24
6
0.0168
955
6.10
7
0.0161
1116
4.92
8
0.0067
733
12.43
9
0.0076
723
9.28
10
0.0214
258
7.11
11
0.0186
227
7.7
12
0.0237
678
4.73
13
0.0249
309
6.73
14
0.0076
234
10.31
15
0.0101
474
9.21
Melanoma
1
0.0164
562
7.16
2
0.0021
490
9.4
3
0.0067
432
11.62
4
0.0033
154
22.98
5
0.0008
286
11.22
6
−0.0012*
228
18.12
7
0.0002
570
28.05
8
0.0047
362
24.39
9
−0.0032
421
8.8
10
0.0007
351
12.79
11
−0.0050
400
12.52
12
0.0004
457
9.69
13
0.0002
196
10.72
14
−0.0024
285
14.71
15
−0.0025
253
14.4
* Negative values means increasing back scatter strength with increasing depth
Based on these critical values absolute and relative frequencies were calculated for the three groups. Chi-squared (χ2) test was employed to compare each melanocytic group versus the other melanocytic groups. The phi (φ) coefficient, employed to weight diagnostic power of each significant parameter, is a measure of association of two binary variables and is related to the Chi-squared (χ2) statistic by the formula: φ 2 = χ2/n, where n equals the total number of observations.
Calculations were made using MedCalc® statistical software version 14.12.0.

Results

Subjects

We included in this retrospective study 45 cases. These cases were retrieved from 2249 patient files collected between 2012 and 2015. Based on dermoscopic or dermoscopic/RCM assessment, 321 cases underwent full excision for histopathologic diagnosis. Forty-nine of these cases have been imaged by HD-OCT whereof 45 cases were retained based on the presence of relevant morphologic features of melanocytic lesions as described previously [9, 20]. The cases comprise 15 BN, 15 DN and 15 melanomas. All melanomas were histopathologically classified as superficial spreading melanomas with a Breslow-index varying between 0.31 and 0.72. The lesions belonged to 25 females and 20 males with skin type I–III and ages ranging from 25 to 70 years (median 51 years).

Quantitative in vivo evaluation (Table 3)

Table 3
Quantitative evaluation of optical properties of melanocytic lesions
Optical properties
Malignant melanoma
Dysplastic nevus
Benign nevus
Relative attenuation factor of first layer µ 1 (µm−1)
0.0014 [±0.0026] (p < 0.001)*
0.0186 [±0.005] (p < 0.001)
0.04541 [±0.0097] (p < 0.001)
Skin entrance signal (arbitrary units)
363 [±65] (p < 0.001)
593 [±134]
765 [±99]
Half value layer (z 1/2) (µm)
13.36 [±3.15] (p < 0.001)
6.50 [±1.26] (p < 0.001)
4.22 [±1.15] (p < 0.001)
p values are mentioned whenever appropriate; for details see “Results” section
1.
µ raf1: a significant difference (p < 0.001) could be observed between the three subgroups in the upper layer. µ raf1 decreased progressively from benign to malignant lesions. No significant differences could be demonstrated between the three groups for the other layers µ raf2-4. (Fig. 4).
 
2.
SES: a significant (p < 0.001) reduction in skin entrance signal could be observed in the melanoma group compared to the two other groups.
 
3.
z 1/2: a significant difference (p < 0.001) could be observed between the three subgroups. This value increased progressively with malignancy.
 

Best critical value of optical properties

Critical values permitting differentiation by HD-OCT of the three subgroups could be defined by applying the receiver operating characteristic curves (ROC curves) and are displayed in Table 4.
Table 4
Selection of best critical value of optical properties of melanocytic lesions by applying receiver operating characteristic curves
Optical properties of melanocytic lesions
Critical value
Area under ROC curve
Sensitivity (%)
Specificity
Accuracy
Positive likelihood ratio
Differentiating malignant melanoma
 Relative attenuation coefficient first layer
<0.0067/µm
0.981
93.3
96.7
95.60
28
 Skin entrance signal
<475
0.86
80.0
83.3
82.2
4.8
 Tissue half value thickness
>8.18 µm
0.960
93.33
86.67
88.9
7
Differentiating benign nevi
 Relative attenuation coefficient first layer
>0.0248/µm
0.847
80.0
90.0
88.89
8
 Skin entrance signal
>678
0.832
80.0
76.6
77.78
3.14
 Half value layer
<6.64 µm
0.847
73.3
73.3
73.33
2.75

Absolute and relative frequencies of optical properties (Table 5)

Table 5
Absolute and relative frequencies of optical properties of melanocytic lesions in relation to critical values as assessed in vivo by high-definition optical coherence tomography
 
Malignant melanoma (N = 15)
Dysplastic nevi (N = 15)
Benign nevi (N = 15)
Differentiating melanoma
 Relative attenuation coefficient at first layer µ < 0.0067/µm
14 (93.3 %) (p < 0.001)*
1 (6.6 %)
0 (0.0 %)
 Skin entrance signal <475 a.u.
12 (80.0 %) (p < 0.001)
4 (26.6 %)
1 (6.6 %)
 Half value layer z 1/2 > 8.18 µm
14 (93.3 %) (p < 0.001)
4 (26.6 %)
0 (0.00 %)
Differentiating benign nevi
 Relative attenuation coefficient at first layer µ > 0.0248/µm
0 (0.0 %)
3 (20.0 %)
13 (86.6 %) (p < 0.001)
 Skin entrance signal > 678 a.u.
0 (0.0 %)
7 (46.6 %)
12 (80.0 %) (p > 0.01)
 Half value layer z 1/2 < 6.64 µm
0 (0.0 %)
8 (33.3 %)
10 (66.6 %) (p < 0.01)
p values have been added whenever appropriate; for details see “Results” section
1.
Differentiation of MM from non-malignant lesions:
  • µ raf1 < 0.0067/µm was a high sensitive (SS) and specific (SP) feature of MM group (93.3 and 96.7 %, respectively; ϕ = 0.90 and χ 2 = 36.45, p < 0.001). Moreover, the negative predictive value (NPV) was 96.7 % and the positive predictive value (PPV) was 93.3 %. The diagnostic accuracy was 95.6 %.
  • SES < 475 a.u. was a sensitive and specific feature of MM group (80.0 and 83.3 %, respectively, NPV = 89.3 %, PPV = 70.6 %, ϕ = 0.62 and χ 2 = 17.06, p < 0.001).
  • z 1/2 > 8.18 µm was a high sensitive and specific feature of MM group (93.3 and 86.7 %, respectively, NPV = 96.3 %, PPV = 77.8 %, ϕ = 0.77 and χ 2 = 26.67, p < 0.001).
 
2.
Differentiation of benign nevi from non-benign nevi (DN and MM)
  • µ raf1 > 0.0248/µm was a sensitive and high specific feature of the BN group (80.0 and 90.0 %, respectively, NPV = 93.0 %, PPV = 81.0 %, ϕ = 0.60, χ 2 = 16.25, p < 0.001). Values higher than this cutoff value were absent in all lesions of the MM group.
  • SES > 678 a.u. was moderate sensitive and specific for the BN group (80.0 and 76.7 %, respectively, NPV = 88.0 % and PPV = 63.0 %, ϕ = 0.54, χ 2 = 13.16, p < 0.01). In MM no value higher than 678 a.u. could be observed.
  • z 1/2 < 6.64 µm was a moderate sensitive and specific feature of the BN group (both 73.3 %, NPV = 85.0 % and PPV = 58.0 %, ϕ = 0.45 and χ 2 = 8.93, p < 0.01). Values lower than this cutoff value were absent in all lesions of the MMgroup.
 

Discussion

Non-invasive imaging techniques have been introduced to improve the early detection of melanoma which can be often challenging with the naked eye alone [10, 17]. Dermoscopy and RCM were shown to improve diagnostic accuracy in this field [11, 32, 33, 48]. In a recent study, almost no melanomas were misclassified and consequently undertreated when both techniques were used in combination: sensitivity 97.82 %, specificity 92.44 %, PPV 87.37 % and NPV 98.75 % [1]. Moreover, a significant reduction in numbers needed to excise could be determined by combining both devices [1, 43]. The problem with dermoscopy and RCM, however, is that their diagnostic performances varies with the user’s experience and would be consequently poor for non-expert physicians [2, 31]. A user-independent, automated classification of pigmented skin lesions based on their optical properties could be achieved by other techniques, such as spectrophotometric technologies [23]. The diagnostic potential of HD-OCT is traditionally thought to be insufficient for ruling out the diagnosis of melanoma, due to limitations of its cellular resolution, as compared to RCM [20]. However, it was shown that HD-OCT allows quantifying the skin reflectance as function of depth [7]. The present study is—to our knowledge—the first one describing the optical properties of benign and malignant melanocytic skin lesions assessed in vivo by means of HD-OCT. We assessed the scattering properties of 45 melanocytic lesions, including 15 benign nevi, 15 dysplastic nevi and 15 melanomas.
Only ballistic photons backscattered to the detection system of the HD-OCT contribute to the image; the decay with depth of focus of reflectance of ballistic photons is a process that can be well modelled by an exponential relationship [26, 29]. The technique of semi-log plot whereby an exponential function becomes a straight line given by y = ax + b has been implemented on HD-OCT signals coming from four successive skin layers (epidermis, upper papillary dermis, deeper papillary dermis and superficial reticular dermis). This permitted the HD-OCT in vivo measurement of skin entrance signal (SES), relative attenuation factor normalized for the skin entrance signal (µ raf1) and half value layer (z 1/2).
A highly significant difference between each melanocytic group could be observed with regard to the measured optical properties. A reduction in µ raf1 and SES and increase of z 1/2 could be noticed with increasing malignancy. Spectrophotometric studies provided evidence of decreased reflectance with increased malignancy of melanocytic lesions [37]. From a clinical point of view, it is more disastrous if MM is misdiagnosed as BN then if a DN is mistaken for a MM. Hence, decision criteria minimizing the false-negative rate deserve priority. Therefore, critical values could be determined for these optical properties permitting differentiation of malignant melanoma from non-malignant melanocytic lesions with high area under the roc curve (AUC) values (0.98, 0.86 and 0.96, respectively) and high positive likelihood ratio’s (28, 4.8 and 7, respectively).
The diagnostic performance of HD-OCT in discriminating MM from non-melanoma based on 3-D cellular and micro-architectural morphological features has been found to be moderate with an NPV (Negative Predictive Value) of 89.7 % [20]. High false-negative rates were observed in very thin MM and high false-positive rates in DN [20]. The present study dealt with superficial spreading melanomas and provided evidence that the diagnostic accuracy of HD-OCT based on the optical properties, µ raf1 , SES and z 1/2 scored much better (95.6, 82.2 and 88.9 %, respectively). High NPV could be found for these optical properties (96.7, 89.3 and 96.3 %, respectively) reducing the risk of mistreating a malignant lesion to a more acceptable level (3.3–7.3 % instead of 11.3 %). The role of spectrophotometry (SPT) in early diagnosis of melanoma in 10 studies has been compared [2]. The authors concluded that low diagnostic accuracy with moderate NPV represented the main hamper for the introduction of SPT technology in clinical practice. HD-OCT enables the rather unique combination of in vivo morphological analysis of cellular and micro-architectural structures with in vivo analysis of optical properties of tissue scatterers.
Optical property measurements sensitive for scattering and anisotropy factor g offer the best means of characterizing the micro-architecture of cells and tissues in general and melanocytic lesions more specifically [27, 45, 47, 49, 55]. Although a lot of variation in data exists, in general there appears to be a trend toward increasing g and decreasing reduced scattering coefficient µs as the wavelength increases. In normal skin with photo type I-III, at 1300 nm (second NIR optical window) the mean value for reduced scattering coefficient µs is 0.001 (±0.0005) [53]. This value is proportional to the measured µ raf measured by HD-OCT. In the upper layer of normal skin at inner site of upper arm significant differences in µ raf1 according to intrinsic ageing could be measured by HD-OCT (unpublished data). In pre-menopausal and post-menopausal females the relative attenuation factor was found to be 0.0114/µm (±0.0012/µm) and 0.0375/µm (±0.0037/µm), respectively. It also appeared that µ raf4 at superficial reticular dermis was significantly higher in pre-menopausal women compared to post-menopausal women; 0.016/µm (±0.0012/µm) and 0.0094/µm (0.0005/µm), respectively (unpublished data). This suggested an intrinsic ageing-related decrease in anisotropy of scattering in upper layers and increase in anisotropy of scattering in lower layers.
In the epidermis, a significant difference (p < 0.001) in relative attenuation factor normalized to skin entrance signal could be observed among the three melanocytic subgroups. This factor is proportional to the µs when a light source of 1300 nm is used [26, 29]. A strong reduction of g and consequently a robust increase in µs could be noticed in BN compared to normal values [29]. Hence, a reduction of factor µ raf1 with increasing malignancy which could be observed in our study implied an important difference in anisotropy factor g among the three melanocytic subgroups. Lower g values (less than 0.8) corresponding with more isotropic scattering seemed to be characteristic for BN. In BN the µs of the upper layer was approximately 3 times higher compared to normal skin. High g values (higher than 0.9) corresponding with strong anisotropic scattering seemed to be characteristic for melanoma. Forward scattering became more likely. In melanoma the upper layer µs seemed to be 10 times lower than normal skin. Hence, the epidermis became much more translucent compared to BN and DN. As a consequence NIR light penetrated much deeper in melanoma than in DN or BN. This probably explains the observed differences in dermoscopic imaging.
Cellular and micro-architectural risk parameters used for diagnosing MM have been determined for HD-OCT such as large roundish pagetoid cells, atypical cell clusters at dermo-epidermal junction, totally disarranged epidermal/dermal pattern and large vertical icicle-shaped structures [9, 20]. With regard to the impact of scattering, alterations of distribution, size, density and orientation of scatterers with malignancy probably are of higher importance than the content of pigment itself because scattering is dependent on the refractive index mismatch between cellular components, extracellular matrix fibres and the extracellular fluid [51]. Dysplastic nevi are characterized by nuclear enlargement, slight irregularity and hyperchromasia, with clumping of chromatin and sometimes with prominent nucleoli. In melanoma besides nuclear atypia, nests and single melanocytes of variable sizes, shapes are present in the epidermis in a pagetoid pattern [16]. A decline of the relative attenuation factor demonstrated in our study suggesting an increase of g value is in line with former observations stating that the average scatterer size in melanoma is significantly larger than those of DN and BN [21, 39, 40].
Some important limitations need to be addressed. This study is a retrospective pilot study. However, this type of study is essential to gather information to design an appropriate (e.g. adequate sample size) prospective study. A second issue is the selected region of interest for optical analysis. This selection needs some experience with morphology analysis of HD-OCT images of melanocytic lesions. This fact questions to some extent the accuracy of HD-OCT optical analysis in the hands of non-experts. Last but not least, the effect of age and gender on optical properties was not taken into account.
In conclusion, HD-OCT seems to enable the rather unique combination of in vivo morphological analysis of cellular and 3-D micro-architectural structures with in vivo analysis of optical properties of tissue scatterers in melanocytic lesions. In vivo HD-OCT analysis of optical properties permits melanoma diagnosis with higher accuracy than in vivo HD-OCT analysis of morphology alone. The diagnostic performance of HD-OCT in MM should be further assessed in other clinical settings combining both types of analysis.

Acknowledgments

The authors are grateful to Marc Weber (Dsc at the research department of Agfa HealthCare) for revising the paper.

Compliance with ethical standards

Conflict of interest

M. Boone, M. Suppa, G. Jemec, V. Del Marmol: none declared. F. Dhaenens (MD), R. Nebosis (Dsc): Research Department Agfa HealthCare.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Dermatologie

Kombi-Abonnement

Mit e.Med Dermatologie erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes Dermatologie, den Premium-Inhalten der dermatologischen Fachzeitschriften, inklusive einer gedruckten dermatologischen Zeitschrift Ihrer Wahl.

Literatur
1.
Zurück zum Zitat Alarcon I, Carrera C, Palou J, Alos L, Malvehy J, Puig S (2014) Impact of in vivo reflectance confocal microscopy on the number needed to treat melanoma in doubtful lesions. Br J Dermatol 170:802–808PubMedPubMedCentralCrossRef Alarcon I, Carrera C, Palou J, Alos L, Malvehy J, Puig S (2014) Impact of in vivo reflectance confocal microscopy on the number needed to treat melanoma in doubtful lesions. Br J Dermatol 170:802–808PubMedPubMedCentralCrossRef
2.
Zurück zum Zitat Ascierto PA, Palla M, Ayala F, De Michele I, Caraco C, Daponte A, Simeone E, Mori S, Del Giudice M, Satriano RA, Vozza A, Palmieri G, Mozzillo N (2010) The role of spectrophotometry in the diagnosis of melanoma. BMC Dermatol 10:5PubMedPubMedCentralCrossRef Ascierto PA, Palla M, Ayala F, De Michele I, Caraco C, Daponte A, Simeone E, Mori S, Del Giudice M, Satriano RA, Vozza A, Palmieri G, Mozzillo N (2010) The role of spectrophotometry in the diagnosis of melanoma. BMC Dermatol 10:5PubMedPubMedCentralCrossRef
3.
Zurück zum Zitat Babalola O, Mamalis A, Lev-Tov H, Jagdeo J (2014) Optical coherence tomography (OCT) of collagen in normal skin and skin fibrosis. Arch Dermatol Res 306:1–9PubMedPubMedCentralCrossRef Babalola O, Mamalis A, Lev-Tov H, Jagdeo J (2014) Optical coherence tomography (OCT) of collagen in normal skin and skin fibrosis. Arch Dermatol Res 306:1–9PubMedPubMedCentralCrossRef
4.
Zurück zum Zitat Balch CM, Gershenwald JE, Soong SJ, Thompson JF, Atkins MB, Byrd DR, Buzaid AC, Cochran AJ, Coit DG, Ding S, Eggermont AM, Flaherty KT, Gimotty PA, Kirkwood JM, McMasters KM, Mihm MC Jr, Morton DL, Ross MI, Sober AJ, Sondak VK (2009) Final version of 2009 AJCC melanoma staging and classification. J Clin Oncol 27:6199–6206PubMedPubMedCentralCrossRef Balch CM, Gershenwald JE, Soong SJ, Thompson JF, Atkins MB, Byrd DR, Buzaid AC, Cochran AJ, Coit DG, Ding S, Eggermont AM, Flaherty KT, Gimotty PA, Kirkwood JM, McMasters KM, Mihm MC Jr, Morton DL, Ross MI, Sober AJ, Sondak VK (2009) Final version of 2009 AJCC melanoma staging and classification. J Clin Oncol 27:6199–6206PubMedPubMedCentralCrossRef
5.
Zurück zum Zitat Boone M, Jemec GB, Del Marmol V (2012) High-definition optical coherence tomography enables visualization of individual cells in healthy skin: comparison to reflectance confocal microscopy. Exp Dermatol 21:740–744PubMed Boone M, Jemec GB, Del Marmol V (2012) High-definition optical coherence tomography enables visualization of individual cells in healthy skin: comparison to reflectance confocal microscopy. Exp Dermatol 21:740–744PubMed
6.
Zurück zum Zitat Boone M, Norrenberg S, Jemec G, Del Marmol V (2013) High-definition optical coherence tomography: adapted algorithmic method for pattern analysis of inflammatory skin diseases: a pilot study. Arch Dermatol Res 305:283–297PubMedPubMedCentralCrossRef Boone M, Norrenberg S, Jemec G, Del Marmol V (2013) High-definition optical coherence tomography: adapted algorithmic method for pattern analysis of inflammatory skin diseases: a pilot study. Arch Dermatol Res 305:283–297PubMedPubMedCentralCrossRef
7.
Zurück zum Zitat Boone M, Suppa M, Marneffe A, Miyamoto M, Jemec G, del Marmol V (2015) High-definition optical coherence tomography: intrinsic skin ageing assessment in women, a pilot study. Arch Dermatol Res 307:705–720PubMedPubMedCentralCrossRef Boone M, Suppa M, Marneffe A, Miyamoto M, Jemec G, del Marmol V (2015) High-definition optical coherence tomography: intrinsic skin ageing assessment in women, a pilot study. Arch Dermatol Res 307:705–720PubMedPubMedCentralCrossRef
8.
Zurück zum Zitat Boone MA, Jemec GB, Del Marmol V (2015) Differentiating allergic and irritant contact dermatitis by high-definition optical coherence tomography: a pilot study. Arch Dermatol Res 307:11–22PubMedPubMedCentralCrossRef Boone MA, Jemec GB, Del Marmol V (2015) Differentiating allergic and irritant contact dermatitis by high-definition optical coherence tomography: a pilot study. Arch Dermatol Res 307:11–22PubMedPubMedCentralCrossRef
9.
Zurück zum Zitat Boone MA, Norrenberg S, Jemec GB, Del Marmol V (2014) High-definition optical coherence tomography imaging of melanocytic lesions: a pilot study. Arch Dermatol Res 306:11–26PubMedPubMedCentralCrossRef Boone MA, Norrenberg S, Jemec GB, Del Marmol V (2014) High-definition optical coherence tomography imaging of melanocytic lesions: a pilot study. Arch Dermatol Res 306:11–26PubMedPubMedCentralCrossRef
10.
Zurück zum Zitat Brehmer F, Ulrich M, Haenssle HA (2012) Strategies for early recognition of cutaneous melanoma-present and future. Dermatol Pract Concept 2(3):203a206 Brehmer F, Ulrich M, Haenssle HA (2012) Strategies for early recognition of cutaneous melanoma-present and future. Dermatol Pract Concept 2(3):203a206
11.
Zurück zum Zitat Carli P, De Giorgi V, Soyer HP, Stante M, Mannone F, Giannotti B (2000) Dermatoscopy in the diagnosis of pigmented skin lesions: a new semiology for the dermatologist. J Eur Acad Dermatol Venereol 14:353–369PubMedCrossRef Carli P, De Giorgi V, Soyer HP, Stante M, Mannone F, Giannotti B (2000) Dermatoscopy in the diagnosis of pigmented skin lesions: a new semiology for the dermatologist. J Eur Acad Dermatol Venereol 14:353–369PubMedCrossRef
12.
Zurück zum Zitat Clemente C, Cochran AJ, Elder DE, Levene A, MacKie RM, Mihm MC, Rilke F, Cascinelli N, Fitzpatrick TB, Sober AJ (1991) Histopathologic diagnosis of dysplastic nevi: concordance among pathologists convened by the World Health Organization Melanoma Programme. Hum Pathol 22:313–319PubMedCrossRef Clemente C, Cochran AJ, Elder DE, Levene A, MacKie RM, Mihm MC, Rilke F, Cascinelli N, Fitzpatrick TB, Sober AJ (1991) Histopathologic diagnosis of dysplastic nevi: concordance among pathologists convened by the World Health Organization Melanoma Programme. Hum Pathol 22:313–319PubMedCrossRef
13.
Zurück zum Zitat Duffy K, Grossman D (2012) The dysplastic nevus: from historical perspective to management in the modern era: part I. Historical, histologic, and clinical aspects. J Am Acad Dermatol 67:1.e1–16 (quiz 17–18) Duffy K, Grossman D (2012) The dysplastic nevus: from historical perspective to management in the modern era: part I. Historical, histologic, and clinical aspects. J Am Acad Dermatol 67:1.e1–16 (quiz 17–18)
14.
Zurück zum Zitat Duffy K, Grossman D (2012) The dysplastic nevus: from historical perspective to management in the modern era: part II. Molecular aspects and clinical management. J Am Acad Dermatol 67:19.e11–12 (quiz 31–12) Duffy K, Grossman D (2012) The dysplastic nevus: from historical perspective to management in the modern era: part II. Molecular aspects and clinical management. J Am Acad Dermatol 67:19.e11–12 (quiz 31–12)
15.
Zurück zum Zitat Eichhorn R, Wessler G, Scholz M, Leupold D, Stankovic G, Buder S, Stucker M, Hoffmann K (2009) Early diagnosis of melanotic melanoma based on laser-induced melanin fluorescence. J Biomed Opt 14:034033PubMedCrossRef Eichhorn R, Wessler G, Scholz M, Leupold D, Stankovic G, Buder S, Stucker M, Hoffmann K (2009) Early diagnosis of melanotic melanoma based on laser-induced melanin fluorescence. J Biomed Opt 14:034033PubMedCrossRef
16.
Zurück zum Zitat Elder DE (2006) Precursors to melanoma and their mimics: nevi of special sites. Mod Pathol 19(Suppl 2):S4–S20PubMedCrossRef Elder DE (2006) Precursors to melanoma and their mimics: nevi of special sites. Mod Pathol 19(Suppl 2):S4–S20PubMedCrossRef
18.
Zurück zum Zitat Gambichler T, Boms S, Stucker M, Moussa G, Kreuter A, Sand M, Sand D, Altmeyer P, Hoffmann K (2005) Acute skin alterations following ultraviolet radiation investigated by optical coherence tomography and histology. Arch Dermatol Res 297:218–225PubMedCrossRef Gambichler T, Boms S, Stucker M, Moussa G, Kreuter A, Sand M, Sand D, Altmeyer P, Hoffmann K (2005) Acute skin alterations following ultraviolet radiation investigated by optical coherence tomography and histology. Arch Dermatol Res 297:218–225PubMedCrossRef
19.
Zurück zum Zitat Gambichler T, Jaedicke V, Terras S (2011) Optical coherence tomography in dermatology: technical and clinical aspects. Arch Dermatol Res 303:457–473PubMedCrossRef Gambichler T, Jaedicke V, Terras S (2011) Optical coherence tomography in dermatology: technical and clinical aspects. Arch Dermatol Res 303:457–473PubMedCrossRef
20.
Zurück zum Zitat Gambichler T, Schmid-Wendtner MH, Plura I, Kampilafkos P, Stucker M, Berking C, Maier T (2015) A multicentre pilot study investigating high-definition optical coherence tomography in the differentiation of cutaneous melanoma and melanocytic naevi. J Eur Acad Dermatol Venereol 29:537–541PubMedCrossRef Gambichler T, Schmid-Wendtner MH, Plura I, Kampilafkos P, Stucker M, Berking C, Maier T (2015) A multicentre pilot study investigating high-definition optical coherence tomography in the differentiation of cutaneous melanoma and melanocytic naevi. J Eur Acad Dermatol Venereol 29:537–541PubMedCrossRef
21.
Zurück zum Zitat Garcia-Uribe A, Smith EB, Zou J, Duvic M, Prieto V, Wang LV (2011) In-vivo characterization of optical properties of pigmented skin lesions including melanoma using oblique incidence diffuse reflectance spectrometry. J Biomed Opt 16:020501PubMedPubMedCentralCrossRef Garcia-Uribe A, Smith EB, Zou J, Duvic M, Prieto V, Wang LV (2011) In-vivo characterization of optical properties of pigmented skin lesions including melanoma using oblique incidence diffuse reflectance spectrometry. J Biomed Opt 16:020501PubMedPubMedCentralCrossRef
22.
Zurück zum Zitat Gutkowicz-Krusin D, Elbaum M, Jacobs A, Keem S, Kopf AW, Kamino H, Wang S, Rubin P, Rabinovitz H, Oliviero M (2000) Precision of automatic measurements of pigmented skin lesion parameters with a MelaFind(TM) multispectral digital dermoscope. Melanoma Res 10:563–570PubMedCrossRef Gutkowicz-Krusin D, Elbaum M, Jacobs A, Keem S, Kopf AW, Kamino H, Wang S, Rubin P, Rabinovitz H, Oliviero M (2000) Precision of automatic measurements of pigmented skin lesion parameters with a MelaFind(TM) multispectral digital dermoscope. Melanoma Res 10:563–570PubMedCrossRef
23.
24.
Zurück zum Zitat Hinz T, Ehler LK, Voth H, Fortmeier I, Hoeller T, Hornung T, Schmid-Wendtner MH (2011) Assessment of tumor thickness in melanocytic skin lesions: comparison of optical coherence tomography, 20-MHz ultrasound and histopathology. Dermatology 223:161–168PubMedCrossRef Hinz T, Ehler LK, Voth H, Fortmeier I, Hoeller T, Hornung T, Schmid-Wendtner MH (2011) Assessment of tumor thickness in melanocytic skin lesions: comparison of optical coherence tomography, 20-MHz ultrasound and histopathology. Dermatology 223:161–168PubMedCrossRef
25.
Zurück zum Zitat Hussain AA, Themstrup L, Jemec GB (2015) Optical coherence tomography in the diagnosis of basal cell carcinoma. Arch Dermatol Res 307:1–10PubMedCrossRef Hussain AA, Themstrup L, Jemec GB (2015) Optical coherence tomography in the diagnosis of basal cell carcinoma. Arch Dermatol Res 307:1–10PubMedCrossRef
26.
Zurück zum Zitat Ivanov AP, Makarevich SA, Khairulina AY (1988) Propagation of radiation in tissues and liquids with densely packed scatterers. J Appl Spectrosc 47:7 Ivanov AP, Makarevich SA, Khairulina AY (1988) Propagation of radiation in tissues and liquids with densely packed scatterers. J Appl Spectrosc 47:7
27.
Zurück zum Zitat Jacques S, Samatham R, Choudhury N, Fu Y, Levitz D (2008) Measuring tissue optical properties in vivo using reflectance-mode confocal microscopy and optical coherence tomography. In: Wax A, Backman W (eds) Biomedical applications of light scattering II, Proc. SPIE 6864, 686410. doi:10.1117/12.761803 Jacques S, Samatham R, Choudhury N, Fu Y, Levitz D (2008) Measuring tissue optical properties in vivo using reflectance-mode confocal microscopy and optical coherence tomography. In: Wax A, Backman W (eds) Biomedical applications of light scattering II, Proc. SPIE 6864, 686410. doi:10.​1117/​12.​761803
29.
Zurück zum Zitat Jacques SL (2013) Optical properties of biological tissues: a review. Phys Med Biol 58:R37–R61PubMedCrossRef Jacques SL (2013) Optical properties of biological tissues: a review. Phys Med Biol 58:R37–R61PubMedCrossRef
30.
32.
Zurück zum Zitat Kittler H, Pehamberger H, Wolff K, Binder M (2002) Diagnostic accuracy of dermoscopy. Lancet Oncol 3:159–165PubMedCrossRef Kittler H, Pehamberger H, Wolff K, Binder M (2002) Diagnostic accuracy of dermoscopy. Lancet Oncol 3:159–165PubMedCrossRef
33.
Zurück zum Zitat Langley RG, Walsh N, Sutherland AE, Propperova I, Delaney L, Morris SF, Gallant C (2007) The diagnostic accuracy of in vivo confocal scanning laser microscopy compared to dermoscopy of benign and malignant melanocytic lesions: a prospective study. Dermatology 215:365–372PubMedCrossRef Langley RG, Walsh N, Sutherland AE, Propperova I, Delaney L, Morris SF, Gallant C (2007) The diagnostic accuracy of in vivo confocal scanning laser microscopy compared to dermoscopy of benign and malignant melanocytic lesions: a prospective study. Dermatology 215:365–372PubMedCrossRef
34.
Zurück zum Zitat Leupold D, Scholz M, Stankovic G, Reda J, Buder S, Eichhorn R, Wessler G, Stucker M, Hoffmann K, Bauer J, Garbe C (2011) The stepwise two-photon excited melanin fluorescence is a unique diagnostic tool for the detection of malignant transformation in melanocytes. Pigment Cell Melanoma Res 24:438–445PubMedCrossRef Leupold D, Scholz M, Stankovic G, Reda J, Buder S, Eichhorn R, Wessler G, Stucker M, Hoffmann K, Bauer J, Garbe C (2011) The stepwise two-photon excited melanin fluorescence is a unique diagnostic tool for the detection of malignant transformation in melanocytes. Pigment Cell Melanoma Res 24:438–445PubMedCrossRef
35.
Zurück zum Zitat Lister T, Wright PA, Chappell PH (2012) Optical properties of human skin. J Biomed Opt 17:90901PubMed Lister T, Wright PA, Chappell PH (2012) Optical properties of human skin. J Biomed Opt 17:90901PubMed
36.
Zurück zum Zitat Lui H, Zhao J, McLean D, Zeng H (2012) Real-time Raman spectroscopy for in vivo skin cancer diagnosis. Cancer Res 72:2491–2500PubMedCrossRef Lui H, Zhao J, McLean D, Zeng H (2012) Real-time Raman spectroscopy for in vivo skin cancer diagnosis. Cancer Res 72:2491–2500PubMedCrossRef
37.
Zurück zum Zitat Marshall RJ (1976) Infrared and ultraviolet photography in a study of the selective absorption of radiation by pigmented lesions of skin. Med Biol Illus 26:71–84PubMed Marshall RJ (1976) Infrared and ultraviolet photography in a study of the selective absorption of radiation by pigmented lesions of skin. Med Biol Illus 26:71–84PubMed
38.
Zurück zum Zitat Meyer N, Lauwers-Cances V, Lourari S, Laurent J, Konstantinou MP, Lagarde JM, Krief B, Batatia H, Lamant L, Paul C (2014) High-frequency ultrasonography but not 930-nm optical coherence tomography reliably evaluates melanoma thickness in vivo: a prospective validation study. Br J Dermatol 171:799–805PubMedCrossRef Meyer N, Lauwers-Cances V, Lourari S, Laurent J, Konstantinou MP, Lagarde JM, Krief B, Batatia H, Lamant L, Paul C (2014) High-frequency ultrasonography but not 930-nm optical coherence tomography reliably evaluates melanoma thickness in vivo: a prospective validation study. Br J Dermatol 171:799–805PubMedCrossRef
39.
Zurück zum Zitat Mourant JR, Canpolat M, Brocker C, Esponda-Ramos O, Johnson TM, Matanock A, Stetter K, Freyer JP (2000) Light scattering from cells: the contribution of the nucleus and the effects of proliferative status. J Biomed Opt 5:131–137PubMedCrossRef Mourant JR, Canpolat M, Brocker C, Esponda-Ramos O, Johnson TM, Matanock A, Stetter K, Freyer JP (2000) Light scattering from cells: the contribution of the nucleus and the effects of proliferative status. J Biomed Opt 5:131–137PubMedCrossRef
40.
Zurück zum Zitat Mourant JR, Freyer JP, Hielscher AH, Eick AA, Shen D, Johnson TM (1998) Mechanisms of light scattering from biological cells relevant to noninvasive optical-tissue diagnostics. Appl Opt 37:3586–3593PubMedCrossRef Mourant JR, Freyer JP, Hielscher AH, Eick AA, Shen D, Johnson TM (1998) Mechanisms of light scattering from biological cells relevant to noninvasive optical-tissue diagnostics. Appl Opt 37:3586–3593PubMedCrossRef
41.
Zurück zum Zitat Murphy BW, Webster RJ, Turlach BA, Quirk CJ, Clay CD, Heenan PJ, Sampson DD (2005) Toward the discrimination of early melanoma from common and dysplastic nevus using fiber optic diffuse reflectance spectroscopy. J Biomed Opt 10:064020PubMedCrossRef Murphy BW, Webster RJ, Turlach BA, Quirk CJ, Clay CD, Heenan PJ, Sampson DD (2005) Toward the discrimination of early melanoma from common and dysplastic nevus using fiber optic diffuse reflectance spectroscopy. J Biomed Opt 10:064020PubMedCrossRef
42.
Zurück zum Zitat Nikolaou V, Stratigos AJ (2014) Emerging trends in the epidemiology of melanoma. Br J Dermatol 170:11–19PubMedCrossRef Nikolaou V, Stratigos AJ (2014) Emerging trends in the epidemiology of melanoma. Br J Dermatol 170:11–19PubMedCrossRef
43.
Zurück zum Zitat Pellacani G, Pepe P, Casari A, Longo C (2014) Reflectance confocal microscopy as a second-level examination in skin oncology improves diagnostic accuracy and saves unnecessary excisions: a longitudinal prospective study. Br J Dermatol 171:1044–1051PubMedCrossRef Pellacani G, Pepe P, Casari A, Longo C (2014) Reflectance confocal microscopy as a second-level examination in skin oncology improves diagnostic accuracy and saves unnecessary excisions: a longitudinal prospective study. Br J Dermatol 171:1044–1051PubMedCrossRef
44.
Zurück zum Zitat Ring HC, Mogensen M, Banzhaf C, Themstrup L, Jemec GB (2013) Optical coherence tomography imaging of telangiectasias during intense pulsed light treatment: a potential tool for rapid outcome assessment. Arch Dermatol Res 305:299–303PubMedCrossRef Ring HC, Mogensen M, Banzhaf C, Themstrup L, Jemec GB (2013) Optical coherence tomography imaging of telangiectasias during intense pulsed light treatment: a potential tool for rapid outcome assessment. Arch Dermatol Res 305:299–303PubMedCrossRef
45.
Zurück zum Zitat Shlivko IL, Kirillin MY, Donchenko EV, Ellinsky DO, Garanina OE, Neznakhina MS, Agrba PD, Kamensky VA (2015) Identification of layers in optical coherence tomography of skin: comparative analysis of experimental and Monte Carlo simulated images. Skin Res Technol. doi:10.1111/srt.12209 PubMed Shlivko IL, Kirillin MY, Donchenko EV, Ellinsky DO, Garanina OE, Neznakhina MS, Agrba PD, Kamensky VA (2015) Identification of layers in optical coherence tomography of skin: comparative analysis of experimental and Monte Carlo simulated images. Skin Res Technol. doi:10.​1111/​srt.​12209 PubMed
46.
Zurück zum Zitat Soong SJ, Ding S, Coit D, Balch CM, Gershenwald JE, Thompson JF, Gimotty P, Force AMT (2010) Predicting survival outcome of localized melanoma: an electronic prediction tool based on the AJCC Melanoma Database. Ann Surg Oncol 17:2006–2014PubMedCrossRef Soong SJ, Ding S, Coit D, Balch CM, Gershenwald JE, Thompson JF, Gimotty P, Force AMT (2010) Predicting survival outcome of localized melanoma: an electronic prediction tool based on the AJCC Melanoma Database. Ann Surg Oncol 17:2006–2014PubMedCrossRef
47.
Zurück zum Zitat Sordillo LA, Pu Y, Pratavieira S, Budansky Y, Alfano RR (2014) Deep optical imaging of tissue using the second and third near-infrared spectral windows. J Biomed Opt 19:056004PubMedCrossRef Sordillo LA, Pu Y, Pratavieira S, Budansky Y, Alfano RR (2014) Deep optical imaging of tissue using the second and third near-infrared spectral windows. J Biomed Opt 19:056004PubMedCrossRef
48.
Zurück zum Zitat Stevenson AD, Mickan S, Mallett S, Ayya M (2013) Systematic review of diagnostic accuracy of reflectance confocal microscopy for melanoma diagnosis in patients with clinically equivocal skin lesions. Dermatol Pract Concept 3:19–27PubMedPubMedCentralCrossRef Stevenson AD, Mickan S, Mallett S, Ayya M (2013) Systematic review of diagnostic accuracy of reflectance confocal microscopy for melanoma diagnosis in patients with clinically equivocal skin lesions. Dermatol Pract Concept 3:19–27PubMedPubMedCentralCrossRef
49.
Zurück zum Zitat Tuchin VV (2006) Tissue and blood optical immersion by exogenous chemical agents. In: Tuchin VV (ed) Optical clearing of tissues and blood. SPIE—The international Society for Optical Engineering, Washington, pp 1–19 Tuchin VV (2006) Tissue and blood optical immersion by exogenous chemical agents. In: Tuchin VV (ed) Optical clearing of tissues and blood. SPIE—The international Society for Optical Engineering, Washington, pp 1–19
50.
Zurück zum Zitat Tuchin VV, Maksimova IL, Zimnyakov DA, Kon IL, Mavlyutov AH, Mishin AA (1997) Light propagation in tissues with controlled optical properties. J Biomed Opt 2:401–417PubMedCrossRef Tuchin VV, Maksimova IL, Zimnyakov DA, Kon IL, Mavlyutov AH, Mishin AA (1997) Light propagation in tissues with controlled optical properties. J Biomed Opt 2:401–417PubMedCrossRef
51.
Zurück zum Zitat Yi J, Backman V (2012) Imaging a full set of optical scattering properties of biological tissue by inverse spectroscopic optical coherence tomography. Opt Lett 37:4443–4445PubMedPubMedCentralCrossRef Yi J, Backman V (2012) Imaging a full set of optical scattering properties of biological tissue by inverse spectroscopic optical coherence tomography. Opt Lett 37:4443–4445PubMedPubMedCentralCrossRef
52.
Zurück zum Zitat Zhao J, Lui H, McLean DI, Zeng H (2008) Real-time Raman spectroscopy for non-invasive skin cancer detection—preliminary results. Conf Proc IEEE Eng Med Biol Soc 2008:3107–3109PubMed Zhao J, Lui H, McLean DI, Zeng H (2008) Real-time Raman spectroscopy for non-invasive skin cancer detection—preliminary results. Conf Proc IEEE Eng Med Biol Soc 2008:3107–3109PubMed
53.
Zurück zum Zitat Zonios G, Dimou A (2009) Light scattering spectroscopy of human skin in vivo. Opt Express 17:1256–1267PubMedCrossRef Zonios G, Dimou A (2009) Light scattering spectroscopy of human skin in vivo. Opt Express 17:1256–1267PubMedCrossRef
54.
Zurück zum Zitat Zonios G, Dimou A, Bassukas I, Galaris D, Tsolakidis A, Kaxiras E (2008) Melanin absorption spectroscopy: new method for noninvasive skin investigation and melanoma detection. J Biomed Opt 13:014017PubMedCrossRef Zonios G, Dimou A, Bassukas I, Galaris D, Tsolakidis A, Kaxiras E (2008) Melanin absorption spectroscopy: new method for noninvasive skin investigation and melanoma detection. J Biomed Opt 13:014017PubMedCrossRef
55.
Zurück zum Zitat Zonios G, Dimou A, Carrara M, Marchesini R (2010) In vivo optical properties of melanocytic skin lesions: common nevi, dysplastic nevi and malignant melanoma. Photochem Photobiol 86:236–240PubMedCrossRef Zonios G, Dimou A, Carrara M, Marchesini R (2010) In vivo optical properties of melanocytic skin lesions: common nevi, dysplastic nevi and malignant melanoma. Photochem Photobiol 86:236–240PubMedCrossRef
Metadaten
Titel
In vivo assessment of optical properties of melanocytic skin lesions and differentiation of melanoma from non-malignant lesions by high-definition optical coherence tomography
verfasst von
M. A. L. M. Boone
M. Suppa
F. Dhaenens
M. Miyamoto
A. Marneffe
G. B. E. Jemec
V. Del Marmol
R. Nebosis
Publikationsdatum
01.01.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Archives of Dermatological Research / Ausgabe 1/2016
Print ISSN: 0340-3696
Elektronische ISSN: 1432-069X
DOI
https://doi.org/10.1007/s00403-015-1608-5

Weitere Artikel der Ausgabe 1/2016

Archives of Dermatological Research 1/2016 Zur Ausgabe

Leitlinien kompakt für die Dermatologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Dermatologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.