Skip to main content
Erschienen in: Archives of Gynecology and Obstetrics 4/2016

11.03.2016 | Maternal-Fetal Medicine

Correlation of fetal scalp blood sampling pH with neonatal outcome umbilical artery pH value

verfasst von: E. Kuehnle, S. Herms, F. Kohls, S. Kundu, P. Hillemanns, Ismini Staboulidou

Erschienen in: Archives of Gynecology and Obstetrics | Ausgabe 4/2016

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Fetal scalp blood sampling is considered as a complimentary tool in addition to cardiotocography to assess fetal well-being. This blood sampling is important as the obstetrician has to judge and make decisions regarding the further management of the delivery based on this pH result. The aim of this study was to analyze the correlation between fetal scalp blood pH and the umbilical artery pH after birth. Furthermore, it was investigated whether tocolysis, a performed episiotomy or cord encirclement have an influence on the umbilical artery pH.

Methods

This retrospective study over a period of 11 years included all singleton pregnancies without fetal anomalies, which were monitored by fetal scalp blood sampling during labor.

Results

844 out of 1502 deliveries were included for analysis. The analysis demonstrates a good correlation between fetal scalp pH value and outcome pH value. Subgroup analysis with fetal scalp blood pH <7.20 showed a difference in 40 of 82 cases, with an outcome pH value ≥7.20, but this difference was statistically insignificant. Neither did tocolysis, episiotomy or the presence of cord encirclement show an overall effect, nor did they have an impact on the subgroup.

Conclusion

Obstetricians must consider that the values of fetal scalp blood are not always reliable and can be false. However, on the basis of CTG and fetal scalp blood pH, decisions are made regarding delivery interventions. Therefore, we would encourage the consideration of taking two samples routinely at every attempt of fetal blood sampling.
Literatur
1.
Zurück zum Zitat Jorgensen JS, Weber T (2014) Fetal scalp blood sampling in labor: a review. Acta Obstet Gynecol Scand 93:548–555CrossRefPubMed Jorgensen JS, Weber T (2014) Fetal scalp blood sampling in labor: a review. Acta Obstet Gynecol Scand 93:548–555CrossRefPubMed
2.
Zurück zum Zitat East CE, Leader LR, Sheehan P, Henshall NE, Colditz PB, Lau R (2015) Intrapartum fetal scalp lactate sampling for fetal assessment in the presence of a non-reassuring fetal heart rate trace. Cochrane Database Syst Rev 1:5 East CE, Leader LR, Sheehan P, Henshall NE, Colditz PB, Lau R (2015) Intrapartum fetal scalp lactate sampling for fetal assessment in the presence of a non-reassuring fetal heart rate trace. Cochrane Database Syst Rev 1:5
3.
Zurück zum Zitat Wiberg-Itzel E, Lipponer C, Norman M, Herbst A, Prebensen D, Hansson A et al (2008) Determination of pH or lactate in fetal scalp blood in management of intrapartum fetal distress: randomised controlled multicentre trial. BMJ 336:1284–1287CrossRefPubMedPubMedCentral Wiberg-Itzel E, Lipponer C, Norman M, Herbst A, Prebensen D, Hansson A et al (2008) Determination of pH or lactate in fetal scalp blood in management of intrapartum fetal distress: randomised controlled multicentre trial. BMJ 336:1284–1287CrossRefPubMedPubMedCentral
4.
Zurück zum Zitat Westerhuis ME, van Horen E, Kwee A, van der Tweel I, Visser GH, Moons KG (2009) Inter- and intra-observer agreement of intrapartum ST analysis of the fetal electrocardiogram in women monitored by STAN. BJOG 116:545–551CrossRefPubMed Westerhuis ME, van Horen E, Kwee A, van der Tweel I, Visser GH, Moons KG (2009) Inter- and intra-observer agreement of intrapartum ST analysis of the fetal electrocardiogram in women monitored by STAN. BJOG 116:545–551CrossRefPubMed
5.
Zurück zum Zitat Devane D, Lalor J (2005) Midwives’ visual interpretation of intrapartum cardiotocographs: intra- and inter-observer agreement. J Adv Nurs 52:133–141CrossRefPubMed Devane D, Lalor J (2005) Midwives’ visual interpretation of intrapartum cardiotocographs: intra- and inter-observer agreement. J Adv Nurs 52:133–141CrossRefPubMed
6.
Zurück zum Zitat Epstein AJ, Twogood S, Lee RH, Opper N, Beavis A, Miller DA (2013) Interobserver reliability of fetal heart rate pattern interpretation using NICHD definitions. Am J Perinatol 30:463–468PubMed Epstein AJ, Twogood S, Lee RH, Opper N, Beavis A, Miller DA (2013) Interobserver reliability of fetal heart rate pattern interpretation using NICHD definitions. Am J Perinatol 30:463–468PubMed
7.
Zurück zum Zitat Ayres-de-Campos D, Bernardes J, Costa-Pereira A, Pereira-Leite L (1999) Inconsistencies in classification by experts of cardiotocograms and subsequent clinical decision. Br J Obstet Gynaecol 106:1307–1310CrossRefPubMed Ayres-de-Campos D, Bernardes J, Costa-Pereira A, Pereira-Leite L (1999) Inconsistencies in classification by experts of cardiotocograms and subsequent clinical decision. Br J Obstet Gynaecol 106:1307–1310CrossRefPubMed
8.
Zurück zum Zitat Rhöse S, Heinis AMF, Vandenbussche F, van Drongelen J, van Dillen J (2014) Inter- and intra-observer agreement of nonreassuring cardiotocography analysis and subsequent clinical management. Acta Obstet Gynecol Scand 93:596–602CrossRefPubMed Rhöse S, Heinis AMF, Vandenbussche F, van Drongelen J, van Dillen J (2014) Inter- and intra-observer agreement of nonreassuring cardiotocography analysis and subsequent clinical management. Acta Obstet Gynecol Scand 93:596–602CrossRefPubMed
9.
Zurück zum Zitat Haverkamp AD, Orleans M, Langendoerfer S, McFee J, Murphy J, Thompson HE (1979) A controlled trial of the differential effect of intrapartum fetal monitoring. Am J Obstet Gynecol 134:399–409PubMed Haverkamp AD, Orleans M, Langendoerfer S, McFee J, Murphy J, Thompson HE (1979) A controlled trial of the differential effect of intrapartum fetal monitoring. Am J Obstet Gynecol 134:399–409PubMed
10.
11.
Zurück zum Zitat Weber T (1982) CTG supplemented with continuous fetal pH monitoring during labour. Acta Obstet Gynecol Scand 61:351–355PubMed Weber T (1982) CTG supplemented with continuous fetal pH monitoring during labour. Acta Obstet Gynecol Scand 61:351–355PubMed
12.
Zurück zum Zitat East CE, Leader LR, Sheehan P, Henshall NE, Colditz PB (2010) Intrapartum fetal scalp lactate sampling for fetal assessment in the presence of a non-reassuring fetal heart rate trace. Cochrane Database Syst Rev 3:CD006174PubMed East CE, Leader LR, Sheehan P, Henshall NE, Colditz PB (2010) Intrapartum fetal scalp lactate sampling for fetal assessment in the presence of a non-reassuring fetal heart rate trace. Cochrane Database Syst Rev 3:CD006174PubMed
13.
Zurück zum Zitat Sherman DJ, Arieli S, Raziel A, Bukovsky I (1994) The effect of sampling technique on measurement of fetal blood pH and gases: an in vitro system. Am J Obstet Gynecol 171:1125–1128CrossRefPubMed Sherman DJ, Arieli S, Raziel A, Bukovsky I (1994) The effect of sampling technique on measurement of fetal blood pH and gases: an in vitro system. Am J Obstet Gynecol 171:1125–1128CrossRefPubMed
14.
Zurück zum Zitat Morgan BLG, Chao CR, Iyer V, Ross MG (2002) Correlation between fetal scalp blood samples and intravascular blood pH, pO2 and oxygen saturation measurements. J Matern Fetal Neonatal Med 11:325–328CrossRefPubMed Morgan BLG, Chao CR, Iyer V, Ross MG (2002) Correlation between fetal scalp blood samples and intravascular blood pH, pO2 and oxygen saturation measurements. J Matern Fetal Neonatal Med 11:325–328CrossRefPubMed
15.
Zurück zum Zitat Parer JT (1980) The current role of intrapartum fetal blood sampling. Clin Obstet Gynecol 23:565–582CrossRefPubMed Parer JT (1980) The current role of intrapartum fetal blood sampling. Clin Obstet Gynecol 23:565–582CrossRefPubMed
16.
Zurück zum Zitat Mahendru AA, Lees CC (2011) Is intrapartum fetal blood sampling a gold standard diagnostic tool for fetal distress? Eur J Obstet Gynecol Reprod Biol 156:137–139CrossRefPubMed Mahendru AA, Lees CC (2011) Is intrapartum fetal blood sampling a gold standard diagnostic tool for fetal distress? Eur J Obstet Gynecol Reprod Biol 156:137–139CrossRefPubMed
17.
Zurück zum Zitat O’Brian YM, Murphy DJ (2013) The reliability of fetal blood sampling as a test of fetal acidosis in labour. Eur J Obstet Gynecol Reprod Biol 167:142–145CrossRef O’Brian YM, Murphy DJ (2013) The reliability of fetal blood sampling as a test of fetal acidosis in labour. Eur J Obstet Gynecol Reprod Biol 167:142–145CrossRef
18.
Zurück zum Zitat Liljestrom L, Wikstrom AK, Hanson U, Akerud H, Jonsson M (2011) Evaluation of the discrepancy between pH and lactate in combined fetal scalp blood sampling. Acta Obstet Gynecol Scand 90:1088–1093CrossRefPubMed Liljestrom L, Wikstrom AK, Hanson U, Akerud H, Jonsson M (2011) Evaluation of the discrepancy between pH and lactate in combined fetal scalp blood sampling. Acta Obstet Gynecol Scand 90:1088–1093CrossRefPubMed
19.
Zurück zum Zitat Chandraharan E, Wiberg N (2014) Fetal scalp blood sampling during labor: an appraisal of the physiological basis and scientific evidence. Acta Obstet Gynecol Scand 93:544–547CrossRefPubMed Chandraharan E, Wiberg N (2014) Fetal scalp blood sampling during labor: an appraisal of the physiological basis and scientific evidence. Acta Obstet Gynecol Scand 93:544–547CrossRefPubMed
20.
Zurück zum Zitat Funk A, Heyl W, Rother R, Winkler M, Rath W (1995) Subpartale Diagnose von Nabelschnurumschlingungen mittels farbcodierter Dopplersonographie und Korrelation zu kardiotokographischen Veränderungen während des Geburtsverlaufes. Geburtsh u Frauenheilk 55:623–627CrossRef Funk A, Heyl W, Rother R, Winkler M, Rath W (1995) Subpartale Diagnose von Nabelschnurumschlingungen mittels farbcodierter Dopplersonographie und Korrelation zu kardiotokographischen Veränderungen während des Geburtsverlaufes. Geburtsh u Frauenheilk 55:623–627CrossRef
21.
Zurück zum Zitat Bogdan C, Meyer C, Rϋttgers H, Kubli F (1971) Die Azidosegefährdung des Fetus bei Nabelschnurumschlingung. Schweiz Z Gynäk Geburtsh 2:441–444 Bogdan C, Meyer C, Rϋttgers H, Kubli F (1971) Die Azidosegefährdung des Fetus bei Nabelschnurumschlingung. Schweiz Z Gynäk Geburtsh 2:441–444
22.
Zurück zum Zitat Bruce S, James SL, Bowe E, Rey H, Shamsi H (1978) Umbilical cord complications as a cause of perinatal morbidity and mortality. J Perinat Med 6:89–94CrossRefPubMed Bruce S, James SL, Bowe E, Rey H, Shamsi H (1978) Umbilical cord complications as a cause of perinatal morbidity and mortality. J Perinat Med 6:89–94CrossRefPubMed
23.
Zurück zum Zitat Spellacy WN, Gravem H, Fisch RO (1966) The umbilical cord complications of true knots, nuchal coils, and cords around the body. Report from the collaborative study of cerebral palsy. Am J Obset Gynecol 94:1136–1142CrossRef Spellacy WN, Gravem H, Fisch RO (1966) The umbilical cord complications of true knots, nuchal coils, and cords around the body. Report from the collaborative study of cerebral palsy. Am J Obset Gynecol 94:1136–1142CrossRef
24.
Zurück zum Zitat Larson LD, Rayburn WF, Crosby S, Thurnau GR (1995) Multiple nuchal cord entanglements and intrapartum complications. Am J Obstet Gynecol 173:1228–1231CrossRefPubMed Larson LD, Rayburn WF, Crosby S, Thurnau GR (1995) Multiple nuchal cord entanglements and intrapartum complications. Am J Obstet Gynecol 173:1228–1231CrossRefPubMed
25.
Zurück zum Zitat Jauniaux E, Ramsay B, Peellaerts C, Scholler Y (1995) Perinatal features of pregnancies complicated by nuchal cord. Am J Perinatol 12:255–258CrossRefPubMed Jauniaux E, Ramsay B, Peellaerts C, Scholler Y (1995) Perinatal features of pregnancies complicated by nuchal cord. Am J Perinatol 12:255–258CrossRefPubMed
26.
Zurück zum Zitat Ertan AK, Schmidt W (1994) Nabelschnurumschlingung und farbcodierte Doppler-Sonographie. Geburtsh u Frauenheilk 54:196–203CrossRef Ertan AK, Schmidt W (1994) Nabelschnurumschlingung und farbcodierte Doppler-Sonographie. Geburtsh u Frauenheilk 54:196–203CrossRef
27.
Zurück zum Zitat Sornes T (1995) Umbilical cord encirclements and fetal growth restriction. Obstet Gynecol 86:725–728CrossRefPubMed Sornes T (1995) Umbilical cord encirclements and fetal growth restriction. Obstet Gynecol 86:725–728CrossRefPubMed
28.
Zurück zum Zitat Osak R, Webster KM, Bocking AD, Campbell MK, Richardson BS (1997) Nuchal cord evident at birth impacts on fetal size relative to that of the placenta. Early Hum Dev 49:193–202CrossRefPubMed Osak R, Webster KM, Bocking AD, Campbell MK, Richardson BS (1997) Nuchal cord evident at birth impacts on fetal size relative to that of the placenta. Early Hum Dev 49:193–202CrossRefPubMed
29.
Zurück zum Zitat Clapp JF 3rd, Stepanchak W, Hashimoto K, Ehrenberg H, Lopez B (2003) The natural history of antenatal nuchal cords. Am J Obstet Gyencol 189:488–493CrossRef Clapp JF 3rd, Stepanchak W, Hashimoto K, Ehrenberg H, Lopez B (2003) The natural history of antenatal nuchal cords. Am J Obstet Gyencol 189:488–493CrossRef
30.
Zurück zum Zitat Schäffer L, Burkhardt T, Zimmermann R, Kurmanavicius J (2005) Nuchal cords in term and postterm deliveries- do we need to know? Obstet Gyencol 106:23–28CrossRef Schäffer L, Burkhardt T, Zimmermann R, Kurmanavicius J (2005) Nuchal cords in term and postterm deliveries- do we need to know? Obstet Gyencol 106:23–28CrossRef
31.
Zurück zum Zitat Martin GC, Green RS, Holzman IR (2005) Acidosis in newborns with nuchal cords and normal APGAR scores. J Perinatol 25:162–165CrossRefPubMed Martin GC, Green RS, Holzman IR (2005) Acidosis in newborns with nuchal cords and normal APGAR scores. J Perinatol 25:162–165CrossRefPubMed
32.
Zurück zum Zitat Önderogly LS, Dursun P, Durukan T (2008) Perinatal features and umbilical cord blood gases in newborns complicated with nuchal cord. Turk J Pediatr 50:466–470 Önderogly LS, Dursun P, Durukan T (2008) Perinatal features and umbilical cord blood gases in newborns complicated with nuchal cord. Turk J Pediatr 50:466–470
33.
Zurück zum Zitat Sadan O, Fleischfarb Z, Everon S, Golan A, Lurie S (2007) Cord around the neck: should it be severed at delivery? A randomized controlled study. Am J Perinatol 24:61–64CrossRefPubMed Sadan O, Fleischfarb Z, Everon S, Golan A, Lurie S (2007) Cord around the neck: should it be severed at delivery? A randomized controlled study. Am J Perinatol 24:61–64CrossRefPubMed
34.
Zurück zum Zitat Yeomans ER, Hauth JC, Gilstrap EC, Strickland DM (1985) Umbilical cord pH, pCO2 and bicarbonate following uncomplicated term vaginal deliveries. Am J Obstet Gynecol 151:798–800CrossRefPubMed Yeomans ER, Hauth JC, Gilstrap EC, Strickland DM (1985) Umbilical cord pH, pCO2 and bicarbonate following uncomplicated term vaginal deliveries. Am J Obstet Gynecol 151:798–800CrossRefPubMed
35.
Zurück zum Zitat Carey JC, Rayburn WF (2003) Nuchal cord encirclements and birth weight. J Reprod Med 48:460–462PubMed Carey JC, Rayburn WF (2003) Nuchal cord encirclements and birth weight. J Reprod Med 48:460–462PubMed
36.
Zurück zum Zitat Yeh P, Emary K, Impey L (2012) The relationship between umbilical cord arterial pH and serious adverse neonatal outcome: analysis of 51519 consecutive validated samples. BJOG 119:824–831CrossRefPubMed Yeh P, Emary K, Impey L (2012) The relationship between umbilical cord arterial pH and serious adverse neonatal outcome: analysis of 51519 consecutive validated samples. BJOG 119:824–831CrossRefPubMed
37.
Zurück zum Zitat Chandraharan E (2014) Fetal scalp blodd sampling during labour: is it a useful diagnostic test or a historical test that no longer has a place in modern clinical obstetrics? BJOG 121:1056–1062CrossRefPubMed Chandraharan E (2014) Fetal scalp blodd sampling during labour: is it a useful diagnostic test or a historical test that no longer has a place in modern clinical obstetrics? BJOG 121:1056–1062CrossRefPubMed
Metadaten
Titel
Correlation of fetal scalp blood sampling pH with neonatal outcome umbilical artery pH value
verfasst von
E. Kuehnle
S. Herms
F. Kohls
S. Kundu
P. Hillemanns
Ismini Staboulidou
Publikationsdatum
11.03.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Archives of Gynecology and Obstetrics / Ausgabe 4/2016
Print ISSN: 0932-0067
Elektronische ISSN: 1432-0711
DOI
https://doi.org/10.1007/s00404-016-4053-6

Weitere Artikel der Ausgabe 4/2016

Archives of Gynecology and Obstetrics 4/2016 Zur Ausgabe

Update Gynäkologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.