Skip to main content
Erschienen in: European Archives of Oto-Rhino-Laryngology 3/2011

01.03.2011 | Otology

“One-shot” CO2 versus Er:YAG laser stapedotomy: is the outcome the same?

verfasst von: Maria Raffaella Marchese, Alessandro Scorpecci, Francesca Cianfrone, Gaetano Paludetti

Erschienen in: European Archives of Oto-Rhino-Laryngology | Ausgabe 3/2011

Einloggen, um Zugang zu erhalten

Abstract

To assess and compare the functional results obtained by means of multiple-shot Erbium: yttrium–aluminum–garnet (Er:YAG) laser to those obtained using “one-shot” CO2 laser stapedotomy in patients affected by otosclerosis. A retrospective case review was performed. Of the total number of 123 patients (114 ears) who underwent primary small-fenestra stapedotomy from January 2006 to September 2008, seven patients who received multiple-shot laser CO2 stapedotomy were excluded from the study. The remaining 116 patients (104 ears) were sorted, and “one-shot” CO2 laser stapedotomy (group A) was performed in 35/104 and Er:YAG laser stapedotomy (group B) in 69/104. After surgery, air conduction-pure tone average (AC-PTA) and air-bone gap (ABG) improved significantly in both groups, whereas sensorineural hearing loss (SNHL) and bone conduction (BC)-PTA did not change in both the groups. In group A, the postoperative ABG was significantly better (12.63 vs. 14.86 dB). Moreover, after “one-shot” stapedotomy, the AC-PTA significantly improved in all tested frequencies. On the contrary, in group B the AC-PTA improved significantly only in two frequencies (0.5 and 1 kHz). Consistent with previous reports, our findings confirm that laser stapedotomy is a safe and effective surgery, regardless of the technique. Based on our functional results, the “one-shot” CO2 laser technique seems to be associated with a significantly better postoperative ABG if compared to Er:YAG laser stapedotomy.
Literatur
1.
Zurück zum Zitat McGee TM (1981) Comparison of small fenestra and total stapedectomy. Ann Otol Rhinol Laryngol 90:633–636PubMed McGee TM (1981) Comparison of small fenestra and total stapedectomy. Ann Otol Rhinol Laryngol 90:633–636PubMed
2.
Zurück zum Zitat Marquet J (1985) Stapedotomy technique and results. Am J Otol 6:63PubMed Marquet J (1985) Stapedotomy technique and results. Am J Otol 6:63PubMed
3.
Zurück zum Zitat McGee TM (1983) The argon laser in surgery for chronic ear disease and otosclerosis. Laryngoscope 93:1177–1182CrossRefPubMed McGee TM (1983) The argon laser in surgery for chronic ear disease and otosclerosis. Laryngoscope 93:1177–1182CrossRefPubMed
4.
Zurück zum Zitat Horn KL, Gherini S, Griffin GM (1990) Argon laser stapedectomy using an Endo-Otoprobe system. Otolaryngol Head Neck Surg 102:193–198PubMed Horn KL, Gherini S, Griffin GM (1990) Argon laser stapedectomy using an Endo-Otoprobe system. Otolaryngol Head Neck Surg 102:193–198PubMed
5.
Zurück zum Zitat Lesinski SG (1989) Lasers for otosclerosis. Laryngoscope 99(Suppl. 46):1–24PubMed Lesinski SG (1989) Lasers for otosclerosis. Laryngoscope 99(Suppl. 46):1–24PubMed
6.
Zurück zum Zitat Lesinski SG (1990) Lasers for otosclerosis—which one if any and why. Lasers Surg Med 10:448–457CrossRefPubMed Lesinski SG (1990) Lasers for otosclerosis—which one if any and why. Lasers Surg Med 10:448–457CrossRefPubMed
7.
Zurück zum Zitat Vernick DM (1996) A comparison of the results of KTP and CO2 laser stapedotomy. Am J Otol 17:221–224PubMed Vernick DM (1996) A comparison of the results of KTP and CO2 laser stapedotomy. Am J Otol 17:221–224PubMed
8.
9.
Zurück zum Zitat Buchman CA, Fucci MJ, Roberson JB Jr, De La Cruz A (2000) Comparison of argon and CO2 laser stapedotomy in primary otosclerosis surgery. Am J Otolaryngol 21:227–230CrossRefPubMed Buchman CA, Fucci MJ, Roberson JB Jr, De La Cruz A (2000) Comparison of argon and CO2 laser stapedotomy in primary otosclerosis surgery. Am J Otolaryngol 21:227–230CrossRefPubMed
10.
Zurück zum Zitat Jovanovic S, Schönfeld U, Prapavat V et al (1996) Effects of continuous wave laser systems on stapes footplate. Lasers Surg Med 19:424–432CrossRefPubMed Jovanovic S, Schönfeld U, Prapavat V et al (1996) Effects of continuous wave laser systems on stapes footplate. Lasers Surg Med 19:424–432CrossRefPubMed
11.
Zurück zum Zitat Jovanovic S, Schonfeld U, Prapavat V, Berghaus A, Fischer R, Scherer H, Muller GJ (1997) Effects of pulsed laser systems on stapes footplate. Lasers Surg Med 21(4):341–350CrossRefPubMed Jovanovic S, Schonfeld U, Prapavat V, Berghaus A, Fischer R, Scherer H, Muller GJ (1997) Effects of pulsed laser systems on stapes footplate. Lasers Surg Med 21(4):341–350CrossRefPubMed
12.
Zurück zum Zitat Jovanovic S, Schonfeld U, Berghaus A et al. (1993) CO2 laser in stapes surgery. In: Shapshay SM, Anderson RR, White JV, White RA, Bass LS (eds) Lasers in otolaryngology, dermatology, and tissue welding. Proc SPIE 1876:17–27 Jovanovic S, Schonfeld U, Berghaus A et al. (1993) CO2 laser in stapes surgery. In: Shapshay SM, Anderson RR, White JV, White RA, Bass LS (eds) Lasers in otolaryngology, dermatology, and tissue welding. Proc SPIE 1876:17–27
13.
Zurück zum Zitat Lesinski SG, Palmer A (1989) CO2 laser for otosclerosis: safe energy parameter. Laryngoscope 99(Suppl 46):9–12PubMed Lesinski SG, Palmer A (1989) CO2 laser for otosclerosis: safe energy parameter. Laryngoscope 99(Suppl 46):9–12PubMed
14.
Zurück zum Zitat Jovanovic S, Jamali Y, Anft D, Schonfeld U, Scherer H, Muller G (2000) Influence of pulsed laser irradiation on the morphology and function of the guinea pig cochlea. Hear Res 144:97–108CrossRefPubMed Jovanovic S, Jamali Y, Anft D, Schonfeld U, Scherer H, Muller G (2000) Influence of pulsed laser irradiation on the morphology and function of the guinea pig cochlea. Hear Res 144:97–108CrossRefPubMed
15.
Zurück zum Zitat Jovanovic S, Shonfeld U, Sherer H (2004) CO2 laser stapedotomy with the “one-shot” technique: clinical results. Otolaryngol Head Neck Surg 131:750CrossRefPubMed Jovanovic S, Shonfeld U, Sherer H (2004) CO2 laser stapedotomy with the “one-shot” technique: clinical results. Otolaryngol Head Neck Surg 131:750CrossRefPubMed
16.
Zurück zum Zitat Jovanovic S (1996) Der Einsatz neuer Lasersysteme in der Stapeschirurgie. In: Müller GJ, Berlien HP (eds) Fortschritte der Lasermedizin 14. Ecomed, Landsberg, pp 1–236 Jovanovic S (1996) Der Einsatz neuer Lasersysteme in der Stapeschirurgie. In: Müller GJ, Berlien HP (eds) Fortschritte der Lasermedizin 14. Ecomed, Landsberg, pp 1–236
17.
Zurück zum Zitat Jovanovic S, Anft D, Schönfeld U et al (1999) Influence of CO2 laser application of the guinea-pig cochlea on compound action potentials. Am J Otol 20:166–173CrossRefPubMed Jovanovic S, Anft D, Schönfeld U et al (1999) Influence of CO2 laser application of the guinea-pig cochlea on compound action potentials. Am J Otol 20:166–173CrossRefPubMed
18.
Zurück zum Zitat Committee on Hearing and Equilibrium (1995) Guidelines for the evaluation of results of treatment of conductive hearing loss. Otolaryngol Head Neck Surg 113:186–187CrossRef Committee on Hearing and Equilibrium (1995) Guidelines for the evaluation of results of treatment of conductive hearing loss. Otolaryngol Head Neck Surg 113:186–187CrossRef
19.
Zurück zum Zitat Hibst R (1992) Mechanical effects of erbium: YAG laser bone ablation. Lasers Surg Med 12:125–130CrossRefPubMed Hibst R (1992) Mechanical effects of erbium: YAG laser bone ablation. Lasers Surg Med 12:125–130CrossRefPubMed
21.
Zurück zum Zitat Antonelli PJ, Gianoli GJ, Lundy LB et al (1998) Early post-laser stapedotomy hearing thresholds. Am J Otol 19:443–446PubMed Antonelli PJ, Gianoli GJ, Lundy LB et al (1998) Early post-laser stapedotomy hearing thresholds. Am J Otol 19:443–446PubMed
22.
Zurück zum Zitat Pratisto H, Frenz M, Ith M et al (1996) Temperature and pressure effects during erbium laser stapedotomy. Lasers Surg Med 18:100–108CrossRefPubMed Pratisto H, Frenz M, Ith M et al (1996) Temperature and pressure effects during erbium laser stapedotomy. Lasers Surg Med 18:100–108CrossRefPubMed
23.
Zurück zum Zitat Galli J, Parrilla C, Fiorita A, Marchese MR, Paludetti G (2005) Erbium: yttrium–aluminum–garnet laser application in stapedotomy. Otolaryngol Head Neck Surg 133:923–928CrossRefPubMed Galli J, Parrilla C, Fiorita A, Marchese MR, Paludetti G (2005) Erbium: yttrium–aluminum–garnet laser application in stapedotomy. Otolaryngol Head Neck Surg 133:923–928CrossRefPubMed
24.
Zurück zum Zitat Huber A, Linder T, Fisch U (2001) Is the Er:YAG laser damaging to inner ear function? Otol Neurotol 22:311–315CrossRefPubMed Huber A, Linder T, Fisch U (2001) Is the Er:YAG laser damaging to inner ear function? Otol Neurotol 22:311–315CrossRefPubMed
25.
Zurück zum Zitat Keck T, Wiebe M, Rettinger G et al (2002) Safety of the erbium:yttrium–aluminum–garnet laser in stapes surgery in otosclerosis. Otol Neurotol 23:21–24CrossRefPubMed Keck T, Wiebe M, Rettinger G et al (2002) Safety of the erbium:yttrium–aluminum–garnet laser in stapes surgery in otosclerosis. Otol Neurotol 23:21–24CrossRefPubMed
26.
Zurück zum Zitat Lippert BM, Gottschlich S, Kulkens C et al (2001) Experimental and clinical results of Er:YAG laser stapedotomy. Lasers Surg Med 28:11–17CrossRefPubMed Lippert BM, Gottschlich S, Kulkens C et al (2001) Experimental and clinical results of Er:YAG laser stapedotomy. Lasers Surg Med 28:11–17CrossRefPubMed
27.
Zurück zum Zitat Parrilla C, Galli J, Fetoni AR, Rigante M, Paludetti G (2008) Erbium: yttrium–aluminium–garnet laser stapedotomy: a safe technique. Otolaryngol Head Neck Surg 138:507–512CrossRefPubMed Parrilla C, Galli J, Fetoni AR, Rigante M, Paludetti G (2008) Erbium: yttrium–aluminium–garnet laser stapedotomy: a safe technique. Otolaryngol Head Neck Surg 138:507–512CrossRefPubMed
28.
Zurück zum Zitat Rosowski JJ, Merchant SN (1995) Mechanical and acoustic analysis of middle ear reconstruction. Am J Otol 16:486–497PubMed Rosowski JJ, Merchant SN (1995) Mechanical and acoustic analysis of middle ear reconstruction. Am J Otol 16:486–497PubMed
29.
Zurück zum Zitat Marchese MR, Cianfrone F, Passali GC, Paludetti G (2007) Hearing results after stapedotomy: role of the prosthesis diameter. Audiol Neurootol 12:221–225CrossRefPubMed Marchese MR, Cianfrone F, Passali GC, Paludetti G (2007) Hearing results after stapedotomy: role of the prosthesis diameter. Audiol Neurootol 12:221–225CrossRefPubMed
Metadaten
Titel
“One-shot” CO2 versus Er:YAG laser stapedotomy: is the outcome the same?
verfasst von
Maria Raffaella Marchese
Alessandro Scorpecci
Francesca Cianfrone
Gaetano Paludetti
Publikationsdatum
01.03.2011
Verlag
Springer-Verlag
Erschienen in
European Archives of Oto-Rhino-Laryngology / Ausgabe 3/2011
Print ISSN: 0937-4477
Elektronische ISSN: 1434-4726
DOI
https://doi.org/10.1007/s00405-010-1399-4

Weitere Artikel der Ausgabe 3/2011

European Archives of Oto-Rhino-Laryngology 3/2011 Zur Ausgabe

Update HNO

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.