Abstract

The Carina© system (Cochlear Ltd, Sydney, Australia) is a totally implantable prosthesis designed to meet the needs of acoustic amplification in adults with moderate-to-severe sensorineural or mixed hearing loss. It mechanically stimulates the ossicles or labyrinthine windows. The object of this study was to update surgical and functional results obtained in a consistent sample of Carina© recipients. The data sheets of 26 patients who underwent Carina© surgery at two ENT units [i.e., ENT Audiology and Phoniatrics Unit of the University Hospital of Pisa (Pisa, Italy) and ENT Unit of “Guglielmo da Saliceto” Hospital of Piacenza (Piacenza, Italy)] were evaluated for the surgical and audiological outcomes. Twenty patients received a unilateral device, whereas six patients were bilaterally implanted (simultaneously in one patient and sequentially in the remaining five patients). The total number of ears implanted in this study was 32. Most implanted patients expressed a high degree of satisfaction with the prosthesis, which highlights the improvement in hearing in different environmental conditions, the cosmetic advantages, and greater freedom in performing common activities in daily living. Audiological examination demonstrated valid functional gain and significant improvement in speech perception in quiet. Based on this experience, the Carina© is a valid alternative to hearing aids. Moreover, a bilateral implantation, even a simultaneous implantation, is a viable option for selected motivated patients because the intervention is generally well tolerated and the surgery time is relatively fast.
Literatur
1.
Zurück zum Zitat Barbara M, Manni V, Monini S (2008) Totally implantable middle ear device for rehabilitation of sensorineural hearing loss: preliminary experience with the Esteem®, Envoy. Acta Otolaryngol 31:1–4 Barbara M, Manni V, Monini S (2008) Totally implantable middle ear device for rehabilitation of sensorineural hearing loss: preliminary experience with the Esteem®, Envoy. Acta Otolaryngol 31:1–4
2.
Zurück zum Zitat Bruschini L, Forli F, Giannarelli M, Bruschini P, Berrettini S (2009) Exclusive transcanal surgical approach for vibrant soundbridge implantation: surgical and functional results. Otol Neurotol 30:950–955CrossRefPubMed Bruschini L, Forli F, Giannarelli M, Bruschini P, Berrettini S (2009) Exclusive transcanal surgical approach for vibrant soundbridge implantation: surgical and functional results. Otol Neurotol 30:950–955CrossRefPubMed
3.
Zurück zum Zitat Bruschini L, Forli F, Passetti S, Bruschini P, Berrettini S (2010) Fully implantable Otologics MET Carina™ device for the treatment of sensorineural and mixed hearing loss: audio-otological results. Acta Otolaryngol 130:1147–1153CrossRefPubMed Bruschini L, Forli F, Passetti S, Bruschini P, Berrettini S (2010) Fully implantable Otologics MET Carina™ device for the treatment of sensorineural and mixed hearing loss: audio-otological results. Acta Otolaryngol 130:1147–1153CrossRefPubMed
4.
Zurück zum Zitat Bruschini L, Forli F, Santoro A, Bruschini P, Berrettini S (2009) Fully implantable Otologics MET Carina device for the treatment of sensorineural hearing loss. Preliminary surgical and clinical results. Acta Otorhinolaryngol Ital 29:79–85PubMedPubMedCentral Bruschini L, Forli F, Santoro A, Bruschini P, Berrettini S (2009) Fully implantable Otologics MET Carina device for the treatment of sensorineural hearing loss. Preliminary surgical and clinical results. Acta Otorhinolaryngol Ital 29:79–85PubMedPubMedCentral
5.
Zurück zum Zitat Fisch U, Cremers CW, Lenarz T, Weber B, Babighian G, Uziel AS et al (2001) Clinical experience with the vibrant sound-bridge implant device. Otol Neurotol 22:962–972CrossRefPubMed Fisch U, Cremers CW, Lenarz T, Weber B, Babighian G, Uziel AS et al (2001) Clinical experience with the vibrant sound-bridge implant device. Otol Neurotol 22:962–972CrossRefPubMed
6.
Zurück zum Zitat Jenkins HA, Niparko JK, Slattery WH, Neely JG, Fredrickson JM (2004) Otologics middle ear transducer ossicular stimulator: performance results with varying degrees of sensorineural hearing loss. Acta Otolaryngol 124:391–394CrossRefPubMed Jenkins HA, Niparko JK, Slattery WH, Neely JG, Fredrickson JM (2004) Otologics middle ear transducer ossicular stimulator: performance results with varying degrees of sensorineural hearing loss. Acta Otolaryngol 124:391–394CrossRefPubMed
7.
Zurück zum Zitat Kasic JF, Fredrickson JM (2001) The Otologics MET ossicular stimulator. Otolaryngol Clin N Am 34:501–513CrossRef Kasic JF, Fredrickson JM (2001) The Otologics MET ossicular stimulator. Otolaryngol Clin N Am 34:501–513CrossRef
8.
Zurück zum Zitat Venail F, Lavieille JP, Meller R, Deveze A, Tardivet L, Magnan J (2007) New perspectives for middle ear implants: first results in otosclerosis with mixed hearing loss. Laryngoscope 117:552–555CrossRefPubMed Venail F, Lavieille JP, Meller R, Deveze A, Tardivet L, Magnan J (2007) New perspectives for middle ear implants: first results in otosclerosis with mixed hearing loss. Laryngoscope 117:552–555CrossRefPubMed
9.
Zurück zum Zitat Jenkins HA, Atkins JS, Horlbeck D, Hoffer ME, Balough B, Arigo JV et al (2007) Phase 1 preliminary results of use of the Otologics MET fully implantable ossicular stimulator. Otolaryngol Head Neck Surg 137:206–212CrossRefPubMed Jenkins HA, Atkins JS, Horlbeck D, Hoffer ME, Balough B, Arigo JV et al (2007) Phase 1 preliminary results of use of the Otologics MET fully implantable ossicular stimulator. Otolaryngol Head Neck Surg 137:206–212CrossRefPubMed
10.
Zurück zum Zitat Jenkins HA, Pergola N, Kasic J (2007) Intra-operative ossicular loading with the Otologics fully implantable hearing device. Acta Otolaryngol 127:360–364CrossRefPubMed Jenkins HA, Pergola N, Kasic J (2007) Intra-operative ossicular loading with the Otologics fully implantable hearing device. Acta Otolaryngol 127:360–364CrossRefPubMed
11.
Zurück zum Zitat Lefebvre PP, Martin C, Dubreuil C, Decat M, Yazbeck A, Kasic J et al (2009) A pilot study of the safety and performance of the Otologics fully implantable hearing device: transducing sounds via the round window membrane to the inner ear. Audiol Neurootol 14:172–180CrossRefPubMed Lefebvre PP, Martin C, Dubreuil C, Decat M, Yazbeck A, Kasic J et al (2009) A pilot study of the safety and performance of the Otologics fully implantable hearing device: transducing sounds via the round window membrane to the inner ear. Audiol Neurootol 14:172–180CrossRefPubMed
12.
Zurück zum Zitat Martin C, Deveze A, Richard C, Lefebvre PP, Decat M, Ibañez LG, Truy E, Mom T (2009) European results with totally implantable carina placed on the round window: 2-year follow-up. Otol Neurotol 30(8):1196–1203CrossRefPubMed Martin C, Deveze A, Richard C, Lefebvre PP, Decat M, Ibañez LG, Truy E, Mom T (2009) European results with totally implantable carina placed on the round window: 2-year follow-up. Otol Neurotol 30(8):1196–1203CrossRefPubMed
13.
Zurück zum Zitat Siegert R, Mattheis S, Kasic J (2007) Fully implantable hearing aids in patients with congenital auricolar atresia. Laryngoscope 117:336–340CrossRefPubMed Siegert R, Mattheis S, Kasic J (2007) Fully implantable hearing aids in patients with congenital auricolar atresia. Laryngoscope 117:336–340CrossRefPubMed
14.
Zurück zum Zitat Tringali S, Pergola N, Berger P, Dubreuil C (2009) Fully implantable hearing device with transducer on the round window as a treatment of mixed hearing loss. Auris Nasus Larynx 36:353–358CrossRefPubMed Tringali S, Pergola N, Berger P, Dubreuil C (2009) Fully implantable hearing device with transducer on the round window as a treatment of mixed hearing loss. Auris Nasus Larynx 36:353–358CrossRefPubMed
15.
Zurück zum Zitat Tringali S, Pergola N, Ferber-Viart F, Truy E, Berger P, Dubreuil C (2008) Fully implantable hearing device as a new treatment of conductive hearing loss in Franceschetti syndrome. Int J Pediatr Otorhinolaryngol 72:513–517CrossRefPubMed Tringali S, Pergola N, Ferber-Viart F, Truy E, Berger P, Dubreuil C (2008) Fully implantable hearing device as a new treatment of conductive hearing loss in Franceschetti syndrome. Int J Pediatr Otorhinolaryngol 72:513–517CrossRefPubMed
16.
Zurück zum Zitat Debeaupte M, Decullier E, Tringali S, Deveze A, Mom T, Darrouzet V, Truy E (2015) Evolution of the reliability PF the fully implantable middle ear transducer over successive generations. Otol Neurotol 36:625–630CrossRefPubMed Debeaupte M, Decullier E, Tringali S, Deveze A, Mom T, Darrouzet V, Truy E (2015) Evolution of the reliability PF the fully implantable middle ear transducer over successive generations. Otol Neurotol 36:625–630CrossRefPubMed
17.
Zurück zum Zitat Turrini M, Cutugno F, Maturi P, Prosser S, Leoni FA, Arslan E (1993) Bisyllabic words for speech audiometry: a new Italian material. Acta Otorhinolaryngol Ital 13:63–77PubMed Turrini M, Cutugno F, Maturi P, Prosser S, Leoni FA, Arslan E (1993) Bisyllabic words for speech audiometry: a new Italian material. Acta Otorhinolaryngol Ital 13:63–77PubMed
18.
Zurück zum Zitat Anonymous (1995) Committee on hearing and equilibrium guidelines for the evaluation of results of treatment of conductive hearing loss. American Academy of Otolaryngology-Head and Neck Surgery Foundation, Inc. Otolaryngol Head Neck Surg 113:186–187CrossRef Anonymous (1995) Committee on hearing and equilibrium guidelines for the evaluation of results of treatment of conductive hearing loss. American Academy of Otolaryngology-Head and Neck Surgery Foundation, Inc. Otolaryngol Head Neck Surg 113:186–187CrossRef
19.
Zurück zum Zitat Cox RM, Alexander GC, Gray GA (2003) Audiometric correlates of the unaided APHAB. J Am Acad Audiol 14:361–371PubMed Cox RM, Alexander GC, Gray GA (2003) Audiometric correlates of the unaided APHAB. J Am Acad Audiol 14:361–371PubMed
20.
Zurück zum Zitat Kontorinis G, Lenarz T, Schwab B (2010) Anatomic limitations in implantation of middle ear transducer and carina middle ear implants. Laryngoscope 120(11):2289–2293CrossRefPubMed Kontorinis G, Lenarz T, Schwab B (2010) Anatomic limitations in implantation of middle ear transducer and carina middle ear implants. Laryngoscope 120(11):2289–2293CrossRefPubMed
21.
Zurück zum Zitat Klein K, Nardelli A, Stafinski T (2012) A systematic review of the safety and effectiveness of fully implantable middle ear hearing devices: the Carina and Esteem systems. Otol Neurotol 33(6):916–921PubMed Klein K, Nardelli A, Stafinski T (2012) A systematic review of the safety and effectiveness of fully implantable middle ear hearing devices: the Carina and Esteem systems. Otol Neurotol 33(6):916–921PubMed
22.
Zurück zum Zitat Lachowska M, Niemczyk K, Yazbeck A, Morawski K, Bruzgielewicz A (2012) First bilateral simultaneous implantation with fully implantable middle ear. Hearing device. Arch Med Sci 8:736–742CrossRefPubMedPubMedCentral Lachowska M, Niemczyk K, Yazbeck A, Morawski K, Bruzgielewicz A (2012) First bilateral simultaneous implantation with fully implantable middle ear. Hearing device. Arch Med Sci 8:736–742CrossRefPubMedPubMedCentral
23.
Zurück zum Zitat Zenner HP, Rodriguez JJ (2010) Totally implantable active middle ear implants. Ten years’ experience at the University of Tübingen. Adv Otorhinolaryngol 69:72–84PubMed Zenner HP, Rodriguez JJ (2010) Totally implantable active middle ear implants. Ten years’ experience at the University of Tübingen. Adv Otorhinolaryngol 69:72–84PubMed
24.
Zurück zum Zitat Deveze A, Rameh C, Sanjuan M, Lavieille JP, Magnan J (2010) A middle ear implant with a titanium canal wall prosthesis for a case of an open mastoid cavity. Auris Nasus Larynx 37:631–635CrossRefPubMed Deveze A, Rameh C, Sanjuan M, Lavieille JP, Magnan J (2010) A middle ear implant with a titanium canal wall prosthesis for a case of an open mastoid cavity. Auris Nasus Larynx 37:631–635CrossRefPubMed
25.
Zurück zum Zitat Kam AC, Sung JK, Yu JK, Tong MC (2012) Clinical evaluation of a fully implantable hearing device in six patients with mixed and sensorineural hearing loss: our experience. Clin Otolaryngol 37:240–244CrossRefPubMed Kam AC, Sung JK, Yu JK, Tong MC (2012) Clinical evaluation of a fully implantable hearing device in six patients with mixed and sensorineural hearing loss: our experience. Clin Otolaryngol 37:240–244CrossRefPubMed
26.
Zurück zum Zitat Otologics (2011) Fully implantable ossicular stimulator MET D109629 Rev B. In: Surgical training manual European Union. Otologics LLC, Boulder Otologics (2011) Fully implantable ossicular stimulator MET D109629 Rev B. In: Surgical training manual European Union. Otologics LLC, Boulder
Metadaten
Titel
The Carina© middle ear implant: surgical and functional outcomes
verfasst von
Luca Bruschini
Stefano Berrettini
Francesca Forli
Alessandra Murri
Domenico Cuda
Publikationsdatum
23.03.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
European Archives of Oto-Rhino-Laryngology / Ausgabe 11/2016
Print ISSN: 0937-4477
Elektronische ISSN: 1434-4726
DOI
https://doi.org/10.1007/s00405-016-3998-1

Weitere Artikel der Ausgabe 11/2016

European Archives of Oto-Rhino-Laryngology 11/2016 Zur Ausgabe

Update HNO

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.