Abstract

Purpose

To assess the impact of iterative reconstruction and filtered back projection (FBP) on image quality in computed tomography (CT)-based forensic age estimation of the medial clavicular epiphysis.

Methods and materials

CT of the clavicle was performed in 19 patients due to forensic reasons (70 mAs/140 kVp). Raw data were reconstructed with FBP and with an iterative algorithm at level 4 and 6. Clavicular ossification stage was determined by two radiologists in consensus, firstly on FBP reconstructed images and secondly after reviewing all reconstructions including iDose 4 and 6. In addition, the 3 reconstructions were compared regarding artefacts and delineation of the meta-/epiphyseal interface. Quantitative image noise was measured.

Results

Quantitative noise was lower in iDose 6 reconstructed images than in FBP (P < 0.042), but not significantly lower between iDose 4 and FBP (P = 0.127). Side by side comparison revealed lesser qualitative image noise on both iDose reconstructed images than for FBP. The meta-/epiphyseal interface delineation was rated better on both iDose levels than with FBP. In 3 of 19 patients, the clavicular ossification stage was reclassified after iterative reconstructions had been additionally reviewed.

Conclusion

Using iterative CT reconstruction algorithms, a reduction of image noise and an enhancement of image quality regarding the meta-/epiphyseal clavicular interface can be achieved. The study highlights the importance of image standardization as variation of reconstruction technique has impact on forensic age estimation.
Literatur
1.
Zurück zum Zitat Wittschieber D, Schulz R, Pfeiffer H, Schmeling A, Schmidt S (2017) Systematic procedure for identifying the five main ossification stages of the medial clavicular epiphysis using computed tomography: a practical proposal for forensic age diagnostics. Int J Legal Med 131(1):217–224. https://doi.org/10.1007/s00414-016-1444-y CrossRefPubMed Wittschieber D, Schulz R, Pfeiffer H, Schmeling A, Schmidt S (2017) Systematic procedure for identifying the five main ossification stages of the medial clavicular epiphysis using computed tomography: a practical proposal for forensic age diagnostics. Int J Legal Med 131(1):217–224. https://​doi.​org/​10.​1007/​s00414-016-1444-y CrossRefPubMed
2.
Zurück zum Zitat Wittschieber D, Schulz R, Vieth V, Kuppers M, Bajanowski T, Ramsthaler F, Puschel K, Pfeiffer H, Schmidt S, Schmeling A (2014) The value of sub-stages and thin slices for the assessment of the medial clavicular epiphysis: a prospective multi-center CT study. Forensic sci, med, pathol 10(2):163–169. https://doi.org/10.1007/s12024-013-9511-x CrossRef Wittschieber D, Schulz R, Vieth V, Kuppers M, Bajanowski T, Ramsthaler F, Puschel K, Pfeiffer H, Schmidt S, Schmeling A (2014) The value of sub-stages and thin slices for the assessment of the medial clavicular epiphysis: a prospective multi-center CT study. Forensic sci, med, pathol 10(2):163–169. https://​doi.​org/​10.​1007/​s12024-013-9511-x CrossRef
12.
Zurück zum Zitat (BfS) FOfRP (2016) Reference levels value in diagnostic and interventional radiology (Bekanntmachung der aktualisierten diagnostischen Referenzwerte für diagnostische und interventionelle Röntgenanwendungen). Information Provided by the Federal Government (BfS) FOfRP (2016) Reference levels value in diagnostic and interventional radiology (Bekanntmachung der aktualisierten diagnostischen Referenzwerte für diagnostische und interventionelle Röntgenanwendungen). Information Provided by the Federal Government
13.
Zurück zum Zitat (ICRP) ICoRP (2007) Radiological Protection in Medicine. ICRP Publication105 (AnnICRP) 37 (6) (ICRP) ICoRP (2007) Radiological Protection in Medicine. ICRP Publication105 (AnnICRP) 37 (6)
20.
Zurück zum Zitat Namasivayam S, Kalra MK, Pottala KM, Waldrop SM, Hudgins PA (2006) Optimization of Z-axis automatic exposure control for multidetector row CT evaluation of neck and comparison with fixed tube current technique for image quality and radiation dose. AJNR Am J Neuroradiol 27(10):2221–2225PubMed Namasivayam S, Kalra MK, Pottala KM, Waldrop SM, Hudgins PA (2006) Optimization of Z-axis automatic exposure control for multidetector row CT evaluation of neck and comparison with fixed tube current technique for image quality and radiation dose. AJNR Am J Neuroradiol 27(10):2221–2225PubMed
25.
Zurück zum Zitat Tozakidou M, Reisinger C, Harder D, Lieb J, Szucs-Farkas Z, Muller-Gerbl M, Studler U, Schindera S, Hirschmann A (2018) Systematic radiation dose reduction in cervical spine CT of human cadaveric specimens: how low can we go? AJNR Am J Neuroradiol 39(2):385–391. https://doi.org/10.3174/ajnr.A5490 CrossRefPubMed Tozakidou M, Reisinger C, Harder D, Lieb J, Szucs-Farkas Z, Muller-Gerbl M, Studler U, Schindera S, Hirschmann A (2018) Systematic radiation dose reduction in cervical spine CT of human cadaveric specimens: how low can we go? AJNR Am J Neuroradiol 39(2):385–391. https://​doi.​org/​10.​3174/​ajnr.​A5490 CrossRefPubMed
27.
30.
Zurück zum Zitat Veldhoen S, Laqmani A, Derlin T, Karul M, Hammerle D, Buhk JH, Sehner S, Nagel HD, Chun F, Adam G, Regier M (2014) 256-MDCT for evaluation of urolithiasis: iterative reconstruction allows for a significant reduction of the applied radiation dose while maintaining high subjective and objective image quality. Journal of medical imaging and radiation oncology 58(3):283–290. https://doi.org/10.1111/1754-9485.12159 CrossRefPubMed Veldhoen S, Laqmani A, Derlin T, Karul M, Hammerle D, Buhk JH, Sehner S, Nagel HD, Chun F, Adam G, Regier M (2014) 256-MDCT for evaluation of urolithiasis: iterative reconstruction allows for a significant reduction of the applied radiation dose while maintaining high subjective and objective image quality. Journal of medical imaging and radiation oncology 58(3):283–290. https://​doi.​org/​10.​1111/​1754-9485.​12159 CrossRefPubMed
36.
Zurück zum Zitat Jurik AG, Jensen LC, Hansen J (1996) Radiation dose by spiral CT and conventional tomography of the sternoclavicular joints and the manubrium sterni. Skelet Radiol 25(5):467–470CrossRef Jurik AG, Jensen LC, Hansen J (1996) Radiation dose by spiral CT and conventional tomography of the sternoclavicular joints and the manubrium sterni. Skelet Radiol 25(5):467–470CrossRef
Metadaten
Titel
Comparison of different iterative CT reconstruction techniques and filtered back projection for assessment of the medial clavicular epiphysis in forensic age estimation
verfasst von
Magdalini Tozakidou
Ilze Apine
Kay U. Petersen
Julius Matthias Weinrich
Sebastian Schindera
Eilin Jopp-van Well
Klaus Püschel
Jochen Herrmann
Publikationsdatum
27.11.2019
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Legal Medicine / Ausgabe 1/2020
Print ISSN: 0937-9827
Elektronische ISSN: 1437-1596
DOI
https://doi.org/10.1007/s00414-019-02214-x

Weitere Artikel der Ausgabe 1/2020

International Journal of Legal Medicine 1/2020 Zur Ausgabe

Neu im Fachgebiet Rechtsmedizin