Skip to main content
Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology 11/2003

01.11.2003 | Clinical Investigation

Characteristics of spontaneous eyeblink activity during video display terminal use in healthy volunteers

verfasst von: Nora Freudenthaler, Hartmut Neuf, Gregor Kadner, Torsten Schlote

Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology | Ausgabe 11/2003

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To analyse the spontaneous eyeblink rate (SEBR) and inter-eyeblink intervals (IEBI) of normal volunteers before and during video display terminal (VDT) use.

Methods

The SEBR of 51 normal volunteers was measured by counting the absence of the corneal reflex using a computer-based video analysis system. Only complete eyeblinks were recorded within 10 min under three different conditions: during a conversation, during VDT use without corneal anaesthesia, and during VDT use with corneal anaesthesia. The IEBI (in seconds) were determined to study individual time-dependent changes of SEBR.

Results

In comparison with SEBR during conversation (mean 15.54 eyeblinks/min, standard deviation ±13.74 eyeblinks/min) the SEBR decreased significantly during VDT use without corneal anaesthesia (5.34 ± 4.53 eyeblinks/min). Corneal anaesthesia further significantly reduced SEBR (2.78 ± 2.77 eyeblinks/min). The SEBR was characterized by marked interindividual variability, ranging between 11 and 664 eyeblinks/10 min during conversation, between 4 and 189 eyeblinks during VDT use without corneal anaesthesia and between 1 and 119 eyeblinks at VDT use with corneal anaesthesia. No significant correlation between SEBR (during conversation or during VDT use) and quality (break-up time) or quantity (Schirmer I test, Jones test) of the tear film could be detected. Evaluation of the IEBI revealed three different types of eyeblink pattern during VDT use without corneal anaesthesia. Type 1 was characterized by a very low SEBR (0–2 eyeblinks/min) and relatively homogeneous distribution of eyeblinks, type 2 showed a moderate SEBR (1.2–8.5 eyeblinks/min) including three further subtypes. Type 3 was characterized by a high SEBR (6.8–18.9 eyeblinks/min) of regular or irregular pattern.

Conclusions

VDT use is associated with a profound decrease of the SEBR in healthy subjects. There are marked interindividual differences in SEBR and no correlation between the SEBR and ocular tear film parameters in normal eyes. The SEBR is further reduced by corneal anaesthesia. The presence of different patterns of eyeblinking may be related to various exogenous and endogenous factors and may lead to a better understanding of ocular reactions during VDT use.
Literatur
1.
Zurück zum Zitat Acosta MC, Gallar J, Belmonte C (1999) The influence of eye solutions on blinking and ocular comfort at rest and during work at video display terminals. Exp Eye Res 68:663–669CrossRefPubMed Acosta MC, Gallar J, Belmonte C (1999) The influence of eye solutions on blinking and ocular comfort at rest and during work at video display terminals. Exp Eye Res 68:663–669CrossRefPubMed
2.
Zurück zum Zitat Al-Abdulmunem M (1999) Relation between tear breakup time and spontaneous blink rate. ICLC 26:117–120PubMed Al-Abdulmunem M (1999) Relation between tear breakup time and spontaneous blink rate. ICLC 26:117–120PubMed
3.
Zurück zum Zitat Carney LG, Hill RM (1982) The nature of normal blinking patterns. Acta Ophthalmol 60:427–433 Carney LG, Hill RM (1982) The nature of normal blinking patterns. Acta Ophthalmol 60:427–433
4.
Zurück zum Zitat Dain SJ, McCarthy AK, Chan-Ling T (1988) Symptoms in VDU operators. Am J Optom Physiol Opt 65:162–167PubMed Dain SJ, McCarthy AK, Chan-Ling T (1988) Symptoms in VDU operators. Am J Optom Physiol Opt 65:162–167PubMed
5.
Zurück zum Zitat Doughty MJ (2001) Consideration of three types of spontaneous eyeblink activity in normal humans: during reading and video display terminal use, in primary gaze, and while in conversation. Optom Vis Sci 78:712–725PubMed Doughty MJ (2001) Consideration of three types of spontaneous eyeblink activity in normal humans: during reading and video display terminal use, in primary gaze, and while in conversation. Optom Vis Sci 78:712–725PubMed
6.
Zurück zum Zitat Hikichi T, Yoshida A, Fukui Y, Hamano T, Ri M, Araki K, Horimotot K, Takamura E, Kitagawa K, Oyama M (1995) Prevalence of dry eye in Japanese eye centers. Graefes Arch Clin Exp Ophthalmol 233:555–558PubMed Hikichi T, Yoshida A, Fukui Y, Hamano T, Ri M, Araki K, Horimotot K, Takamura E, Kitagawa K, Oyama M (1995) Prevalence of dry eye in Japanese eye centers. Graefes Arch Clin Exp Ophthalmol 233:555–558PubMed
7.
Zurück zum Zitat Jones LT (1966) The lacrimal secretory system and its treatment. Am J Ophthalmol 62:47–60PubMed Jones LT (1966) The lacrimal secretory system and its treatment. Am J Ophthalmol 62:47–60PubMed
8.
Zurück zum Zitat Karson CN, Berman KF, Donnelly EF, Mendelson WB, Kleinman JE, Wyatt RJ (1981) Speaking, thinking and blinking. Psychiatry Res 5:243–246CrossRefPubMed Karson CN, Berman KF, Donnelly EF, Mendelson WB, Kleinman JE, Wyatt RJ (1981) Speaking, thinking and blinking. Psychiatry Res 5:243–246CrossRefPubMed
9.
Zurück zum Zitat Nakamori K, Odawara BS, Nakajimia T, Mizutani T, Tsubota K (1997) Blinking is controlled primarily by ocular surface conditions. Am J Ophthalmol 124:24–30PubMed Nakamori K, Odawara BS, Nakajimia T, Mizutani T, Tsubota K (1997) Blinking is controlled primarily by ocular surface conditions. Am J Ophthalmol 124:24–30PubMed
10.
Zurück zum Zitat Patel S, Henderson R, Bradley L, Galloway B (1991) Effect of visual display unit use on blink rate and tear stability. Optom Vis Sci 68:888–892PubMed Patel S, Henderson R, Bradley L, Galloway B (1991) Effect of visual display unit use on blink rate and tear stability. Optom Vis Sci 68:888–892PubMed
11.
Zurück zum Zitat Prause JU, Norn M (1987) Relation between blink frequency and break-up time. Acta Ophthalmol 65:19–22 Prause JU, Norn M (1987) Relation between blink frequency and break-up time. Acta Ophthalmol 65:19–22
12.
Zurück zum Zitat Salibello C, Nilsen E (1995) Is there a typical VDT patient? A demographic analysis. J Am Optom Assoc 66(8): 479–483PubMed Salibello C, Nilsen E (1995) Is there a typical VDT patient? A demographic analysis. J Am Optom Assoc 66(8): 479–483PubMed
13.
Zurück zum Zitat Schirmer O (1903) Studien zur Physiologie und Pathologie der Tränenabsonderung und Tränenabfuhr. Albrecht v Graefes Arch Ophthalmol 56:197–291 Schirmer O (1903) Studien zur Physiologie und Pathologie der Tränenabsonderung und Tränenabfuhr. Albrecht v Graefes Arch Ophthalmol 56:197–291
14.
Zurück zum Zitat Shimmura S, Shimazaki J, Tsubota K (1999) Results of a population-based questionnaire on the symptoms and lifestyles associated with dry eye. Cornea 18:408–411PubMed Shimmura S, Shimazaki J, Tsubota K (1999) Results of a population-based questionnaire on the symptoms and lifestyles associated with dry eye. Cornea 18:408–411PubMed
15.
Zurück zum Zitat Stern JA (1994) Blink rate: a possible measure of fatigue. Human factors 36:285–297PubMed Stern JA (1994) Blink rate: a possible measure of fatigue. Human factors 36:285–297PubMed
16.
Zurück zum Zitat Thomson WD (1998) Eye problems and visual display terminals—the facts and the fallacies. Ophthalmic Physiol Opt 18 (2): 111–119PubMed Thomson WD (1998) Eye problems and visual display terminals—the facts and the fallacies. Ophthalmic Physiol Opt 18 (2): 111–119PubMed
17.
Zurück zum Zitat Toda I, Fujishima H, Tsubota K (1993) Ocular fatigue is the major symptom of dry eye. Acta Ophthalmol 71:347–352 Toda I, Fujishima H, Tsubota K (1993) Ocular fatigue is the major symptom of dry eye. Acta Ophthalmol 71:347–352
18.
Zurück zum Zitat Tsubota K, Nakamori K (1993) Dry eyes and video display terminals. N Engl J Med 328:584CrossRef Tsubota K, Nakamori K (1993) Dry eyes and video display terminals. N Engl J Med 328:584CrossRef
19.
Zurück zum Zitat Tsubota K, Nakamori K (1995) Effects of ocular surface area and blink rate on tear dynamics. Arch Ophthalmol 113:155–158PubMed Tsubota K, Nakamori K (1995) Effects of ocular surface area and blink rate on tear dynamics. Arch Ophthalmol 113:155–158PubMed
20.
Zurück zum Zitat Tsubota K, Hata S, Okusawa Y, Egami F, Ohtsuki T, Nakamori K (1996) Quantitative videographic analysis of blinking in normal subjects and patients with dry eye. Arch Ophthalmol 114:715–720PubMed Tsubota K, Hata S, Okusawa Y, Egami F, Ohtsuki T, Nakamori K (1996) Quantitative videographic analysis of blinking in normal subjects and patients with dry eye. Arch Ophthalmol 114:715–720PubMed
21.
Zurück zum Zitat Yap M (1991) Tear-break-up time is related to blink frequency. Acta Ophthalmol 69:92–94 Yap M (1991) Tear-break-up time is related to blink frequency. Acta Ophthalmol 69:92–94
22.
Zurück zum Zitat Zaman ML, Doughty MJ, Button NF (1998) The exposed ocular surface and its relationship to spontaneous eyeblink rate in elderly caucasians. Exp Eye Res 67:681–686CrossRefPubMed Zaman ML, Doughty MJ, Button NF (1998) The exposed ocular surface and its relationship to spontaneous eyeblink rate in elderly caucasians. Exp Eye Res 67:681–686CrossRefPubMed
Metadaten
Titel
Characteristics of spontaneous eyeblink activity during video display terminal use in healthy volunteers
verfasst von
Nora Freudenthaler
Hartmut Neuf
Gregor Kadner
Torsten Schlote
Publikationsdatum
01.11.2003
Verlag
Springer-Verlag
Erschienen in
Graefe's Archive for Clinical and Experimental Ophthalmology / Ausgabe 11/2003
Print ISSN: 0721-832X
Elektronische ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-003-0786-6

Weitere Artikel der Ausgabe 11/2003

Graefe's Archive for Clinical and Experimental Ophthalmology 11/2003 Zur Ausgabe

Laboratory Investigation

Cathepsin B in the rat eye

Neu im Fachgebiet Augenheilkunde

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.