Skip to main content
Erschienen in: European Journal of Applied Physiology 1/2004

01.01.2004 | Original Article

Reliability and validity of the Biodex system 3 pro isokinetic dynamometer velocity, torque and position measurements

verfasst von: Joshua M. Drouin, Tamara C. Valovich-mcLeod, Sandra J. Shultz, Bruce M. Gansneder, David H. Perrin

Erschienen in: European Journal of Applied Physiology | Ausgabe 1/2004

Einloggen, um Zugang zu erhalten

Abstract

This study quantitatively assessed the mechanical reliability and validity of position, torque and velocity measurements of the Biodex System 3 isokinetic dynamometer. Trial-to-trial and day-to-day reliability were assessed during three trials on two separate days. To assess instrument validity, measurement of each variable using the Biodex System 3 dynamometer was compared to a criterion measure of position, torque and velocity. Position was assessed at 5° increments across the available range of motion of the dynamometer. Torque measures were assessed isometrically by hanging six different calibrated weights from the lever arm. Velocity was assessed (30°/s to 500°/s) across a 70° arc of motion by manually accelerating the weighted lever arm. With the exception of a systematic decrease in velocity at speeds of 300°/s and higher, the Biodex System 3 performed with acceptable mechanical reliability and validity on all variables tested.
Literatur
Zurück zum Zitat Bemben MG, Grump KJ, Massey BH (1988) Assessment of technical accuracy of the Cybex II isokinetic dynamometer and analog recording system. J Orthop Sports Phys Ther 10:12–17 Bemben MG, Grump KJ, Massey BH (1988) Assessment of technical accuracy of the Cybex II isokinetic dynamometer and analog recording system. J Orthop Sports Phys Ther 10:12–17
Zurück zum Zitat Brown LE, Whitehurst M, Bryant JR, Buchalter DN (1993) Reliability of the Biodex System 2 isokinetic dynamometer concentric mode. Isokin Exerc Sci 3:106–163 Brown LE, Whitehurst M, Bryant JR, Buchalter DN (1993) Reliability of the Biodex System 2 isokinetic dynamometer concentric mode. Isokin Exerc Sci 3:106–163
Zurück zum Zitat Denegar CR, Ball DW (1993) Assessing reliability and precision of measurement: an introduction to intraclass correlation and standard error of measurement. J Sport Rehabil 2:35–42 Denegar CR, Ball DW (1993) Assessing reliability and precision of measurement: an introduction to intraclass correlation and standard error of measurement. J Sport Rehabil 2:35–42
Zurück zum Zitat Farrell M, Richards JG (1986) Analysis of the reliability and validity of the kinetic communicator exercise device. Med Sci Sports Exerc 18:44–49PubMed Farrell M, Richards JG (1986) Analysis of the reliability and validity of the kinetic communicator exercise device. Med Sci Sports Exerc 18:44–49PubMed
Zurück zum Zitat Feiring DC, Ellenbecker TS, Dersheid GL (1990) Test-retest reliability of the Biodex isokinetic dynamometer. J Orthop Sports Phys Ther 11:298–300 Feiring DC, Ellenbecker TS, Dersheid GL (1990) Test-retest reliability of the Biodex isokinetic dynamometer. J Orthop Sports Phys Ther 11:298–300
Zurück zum Zitat Gleeson NP, Mercer TH (1996) The utility of isokinetic dynamometry in the assessment of human muscle function. Sports Med 21:18–34PubMed Gleeson NP, Mercer TH (1996) The utility of isokinetic dynamometry in the assessment of human muscle function. Sports Med 21:18–34PubMed
Zurück zum Zitat Handel M, Dickhuth HH, Mayer F, Gulch RW (1996) Prerequisites and limitations to isokinetic measurements in humans: Investigations on a servomotor-controlled dynamometer. Eur J Appl Physiol 73:225–230 Handel M, Dickhuth HH, Mayer F, Gulch RW (1996) Prerequisites and limitations to isokinetic measurements in humans: Investigations on a servomotor-controlled dynamometer. Eur J Appl Physiol 73:225–230
Zurück zum Zitat Iossifidou AN, Baltzopoulos V (2000) Inertial effects on moment development during isokinetic concentric knee extension testing. J Orthop Sports Phys Ther 30:317–327PubMed Iossifidou AN, Baltzopoulos V (2000) Inertial effects on moment development during isokinetic concentric knee extension testing. J Orthop Sports Phys Ther 30:317–327PubMed
Zurück zum Zitat Murray DA, Harrison E (1986) Constant velocity dynamometer: an appraisal using mechanical loading. Med Sci Sports Exerc 18:612–624PubMed Murray DA, Harrison E (1986) Constant velocity dynamometer: an appraisal using mechanical loading. Med Sci Sports Exerc 18:612–624PubMed
Zurück zum Zitat Patterson LA, Spivey WE (1992) Validity and reliability of the LIDO active isokinetic system. J Orthop Sports Phys Ther 15:32–36 Patterson LA, Spivey WE (1992) Validity and reliability of the LIDO active isokinetic system. J Orthop Sports Phys Ther 15:32–36
Zurück zum Zitat Portney LG, Watkins MP (2000) Statistical measures of reliability. In: Foundations of clinical research: applications to practice, 2nd edn. Prentice Hall, New Jersey, pp 557–584 Portney LG, Watkins MP (2000) Statistical measures of reliability. In: Foundations of clinical research: applications to practice, 2nd edn. Prentice Hall, New Jersey, pp 557–584
Zurück zum Zitat Sapega AA, Nicholas JA, Sokolow D, Saraniti A (1982) The nature of torque "overshoot" in Cybex isokinetic dynamometry. Med Sci Sports Exerc 14:368–375PubMed Sapega AA, Nicholas JA, Sokolow D, Saraniti A (1982) The nature of torque "overshoot" in Cybex isokinetic dynamometry. Med Sci Sports Exerc 14:368–375PubMed
Zurück zum Zitat Shrout PE, Fleiss JL (1979) Intraclass correlations: uses in assessing rater reliability. Psychol Bull 86:420–428CrossRef Shrout PE, Fleiss JL (1979) Intraclass correlations: uses in assessing rater reliability. Psychol Bull 86:420–428CrossRef
Zurück zum Zitat Taylor NAS, Sanders RH, Howick EI, Stanley SN (1991) Static and dynamic assessment of the Biodex dynamometer. Eur J Appl Physiol 62:180–188 Taylor NAS, Sanders RH, Howick EI, Stanley SN (1991) Static and dynamic assessment of the Biodex dynamometer. Eur J Appl Physiol 62:180–188
Zurück zum Zitat Timm KE, Gennrich P, Burns R, Fyke D (1992) The mechanical and physiological performance reliability of selected isokinetic dynamometers. Isokin Exerc Sci 2:182–190 Timm KE, Gennrich P, Burns R, Fyke D (1992) The mechanical and physiological performance reliability of selected isokinetic dynamometers. Isokin Exerc Sci 2:182–190
Metadaten
Titel
Reliability and validity of the Biodex system 3 pro isokinetic dynamometer velocity, torque and position measurements
verfasst von
Joshua M. Drouin
Tamara C. Valovich-mcLeod
Sandra J. Shultz
Bruce M. Gansneder
David H. Perrin
Publikationsdatum
01.01.2004
Verlag
Springer-Verlag
Erschienen in
European Journal of Applied Physiology / Ausgabe 1/2004
Print ISSN: 1439-6319
Elektronische ISSN: 1439-6327
DOI
https://doi.org/10.1007/s00421-003-0933-0

Weitere Artikel der Ausgabe 1/2004

European Journal of Applied Physiology 1/2004 Zur Ausgabe