Comparison of three mobile devices for measuring R–R intervals and heart rate variability: Polar S810i, Suunto t6 and an ambulatory ECG system

verfasst von: Matthias Weippert, Mohit Kumar, Steffi Kreuzfeld, Dagmar Arndt, Annika Rieger, Regina Stoll

Erschienen in: European Journal of Applied Physiology | Ausgabe 4/2010

Einloggen, um Zugang zu erhalten

Abstract

The first aim of this study was to compare an ambulatory five-lead ECG system with the commercially available breast belt measuring devices; Polar S810i and Suunto t6, in terms of R–R interval measures and heart rate variability (HRV) indices. The second aim was to compare different HRV spectral analysis methods. Nineteen young males (aged between 22 and 31 years, median 24 years) underwent simultaneous R–R interval recordings with the three instruments during supine and sitting rest, moderate dynamic, and moderate to vigorous static exercise of the upper and lower limb. For each subject, 17 R–R interval series of 3-min length were extracted from the whole recordings and then analyzed in frequency domain using (1) a fast Fourier transform (FFT), (2) an autoregressive model (AR), (3) a Welch periodogram (WP) and (4) a continuous wavelet transform (CWT). Intra-class correlation coefficients (ICC) and Bland–Altman limits of agreement (LoA) method served as criteria for measurement agreement. Regarding the R–R interval recordings, ICC (lower ICC 95% confidence interval >0.99) as well as LoA (maximum LoA: −15.1 to 14.3 ms for ECG vs. Polar) showed an excellent agreement between all devices. Therefore, the three instruments may be used interchangeably in recording and interpolation of R–R intervals. ICCs for HRV frequency parameters were also high, but in most cases LoA analysis revealed unacceptable discrepancies between the instruments. The agreement among the different frequency transform methods can be taken for granted when analyzing the normalized power in low and high frequency ranges; however, not when analyzing the absolute values.
Literatur
Zurück zum Zitat Backs RW (1995) Going beyond heart rate: autonomic space and cardiovascular assessment of mental workload. Int J d Psychology 5:25–48 Backs RW (1995) Going beyond heart rate: autonomic space and cardiovascular assessment of mental workload. Int J d Psychology 5:25–48
Zurück zum Zitat Belova NY, Mihaylov SV, Piryova BG (2007) Wavelet transform: a better approach for the evaluation of instantaneous changes in heart rate variability. Auton Neurosci 131:107–122CrossRefPubMed Belova NY, Mihaylov SV, Piryova BG (2007) Wavelet transform: a better approach for the evaluation of instantaneous changes in heart rate variability. Auton Neurosci 131:107–122CrossRefPubMed
Zurück zum Zitat Berntson GG, Bigger T Jr, Eckberg DL, Grossman P, Kaufmann PG, Malik M, Nagaraja HN, Porges SW, Saul JP, Stone PH, van der Molen MW (1997) Heart rate variability: origins methods, and interpretive caveats. Psychophysiology 34:623–648CrossRefPubMed Berntson GG, Bigger T Jr, Eckberg DL, Grossman P, Kaufmann PG, Malik M, Nagaraja HN, Porges SW, Saul JP, Stone PH, van der Molen MW (1997) Heart rate variability: origins methods, and interpretive caveats. Psychophysiology 34:623–648CrossRefPubMed
Zurück zum Zitat Bland JM, Altman DG (2007) Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat 17:571–582CrossRefPubMed Bland JM, Altman DG (2007) Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat 17:571–582CrossRefPubMed
Zurück zum Zitat Bürklein M, Vogt L, Banzer W (2005) Cross validation of heart rate variability measurements before and after exercise. Dtsch Z Sportmed 56:415–421 Bürklein M, Vogt L, Banzer W (2005) Cross validation of heart rate variability measurements before and after exercise. Dtsch Z Sportmed 56:415–421
Zurück zum Zitat Clifford GD, Tarassenko L (2005) Quantifying errors in spectral estimates of HRV due to beat replacement and resampling. IEEE Trans Biomed Eng 52:630–638CrossRefPubMed Clifford GD, Tarassenko L (2005) Quantifying errors in spectral estimates of HRV due to beat replacement and resampling. IEEE Trans Biomed Eng 52:630–638CrossRefPubMed
Zurück zum Zitat Gamelin FX, Berthoin S, Bosquet L (2006) Validity of the Polar S810 heart rate monitor to measure R–R intervals at rest. Med Sci Sports Exerc 38:887–893CrossRefPubMed Gamelin FX, Berthoin S, Bosquet L (2006) Validity of the Polar S810 heart rate monitor to measure R–R intervals at rest. Med Sci Sports Exerc 38:887–893CrossRefPubMed
Zurück zum Zitat Gamelin FX, Baquet G, Berthoin S, Bosquet L (2008) Validity of the Polar S810 to measure R–R intervals in children. Int J Sports Med 29:134–138CrossRefPubMed Gamelin FX, Baquet G, Berthoin S, Bosquet L (2008) Validity of the Polar S810 to measure R–R intervals in children. Int J Sports Med 29:134–138CrossRefPubMed
Zurück zum Zitat Hernandez-Garcia R, Torres-Luque G, Villaverde-Gutierrez C (2009) Physiological requirements of judo combat. Int J Sports Med 10:145–151 Hernandez-Garcia R, Torres-Luque G, Villaverde-Gutierrez C (2009) Physiological requirements of judo combat. Int J Sports Med 10:145–151
Zurück zum Zitat Hottenrott K, Hoos O, Esperer HD (2006) Heart rate variability and physical exercise. Current status. Herz 31:544–552CrossRefPubMed Hottenrott K, Hoos O, Esperer HD (2006) Heart rate variability and physical exercise. Current status. Herz 31:544–552CrossRefPubMed
Zurück zum Zitat Kaber DB, Perry CM, Segall N, Sheik-Nainar MA (2007) Workload state classification with automation during simulated air traffic control. Int J Aviat Psychol 17:371–390 Kaber DB, Perry CM, Segall N, Sheik-Nainar MA (2007) Workload state classification with automation during simulated air traffic control. Int J Aviat Psychol 17:371–390
Zurück zum Zitat Kingsley M, Lewis MJ, Marson RE (2005) Comparison of Polar 810s and an ambulatory ECG system for RR interval measurement during progressive exercise. Int J Sports Med 26:39–44CrossRefPubMed Kingsley M, Lewis MJ, Marson RE (2005) Comparison of Polar 810s and an ambulatory ECG system for RR interval measurement during progressive exercise. Int J Sports Med 26:39–44CrossRefPubMed
Zurück zum Zitat Kiviniemi AM, Hautala AJ, Kinnunen H, Tulppo MP (2007) Endurance training guided individually by daily heart rate variability measurements. Eur J Appl Physiol 101:743–751CrossRefPubMed Kiviniemi AM, Hautala AJ, Kinnunen H, Tulppo MP (2007) Endurance training guided individually by daily heart rate variability measurements. Eur J Appl Physiol 101:743–751CrossRefPubMed
Zurück zum Zitat Kumar M, Weippert M, Vilbrandt R, Kreuzfeld S, Stoll R (2007) Fuzzy evaluation of heart rate signals for mental stress assessment. IEEE Trans Fuzzy Syst 15:791–808CrossRef Kumar M, Weippert M, Vilbrandt R, Kreuzfeld S, Stoll R (2007) Fuzzy evaluation of heart rate signals for mental stress assessment. IEEE Trans Fuzzy Syst 15:791–808CrossRef
Zurück zum Zitat Nunan D, Jakovljevic DG, Donovan G, Hodges LD, Sandercock GR, Brodie DA (2008) Levels of agreement for RR intervals and short-term heart rate variability obtained from the Polar S810 and an alternative system. Eur J Appl Physiol 103:529–537CrossRefPubMed Nunan D, Jakovljevic DG, Donovan G, Hodges LD, Sandercock GR, Brodie DA (2008) Levels of agreement for RR intervals and short-term heart rate variability obtained from the Polar S810 and an alternative system. Eur J Appl Physiol 103:529–537CrossRefPubMed
Zurück zum Zitat Roy RA, Boucher JP, Comtois AS (2009) Heart rate variability modulation after manipulation in pain-free patients vs patients in pain. J Manipulative Physiol Ther 32:277–286CrossRefPubMed Roy RA, Boucher JP, Comtois AS (2009) Heart rate variability modulation after manipulation in pain-free patients vs patients in pain. J Manipulative Physiol Ther 32:277–286CrossRefPubMed
Zurück zum Zitat Sandercock GR, Shelton C, Bromley P, Brodie DA (2004) Agreement between three commercially available instruments for measuring short-term heart rate variability. Physiol Meas 25:1115–1124CrossRefPubMed Sandercock GR, Shelton C, Bromley P, Brodie DA (2004) Agreement between three commercially available instruments for measuring short-term heart rate variability. Physiol Meas 25:1115–1124CrossRefPubMed
Zurück zum Zitat Schandry R (1981) Psychophysiologie. Urban & Schwarzenberg, München Schandry R (1981) Psychophysiologie. Urban & Schwarzenberg, München
Zurück zum Zitat Turner SE, Eastwood PR, Cecins NM, Hillman DR, Jenkins SC (2004) Physiologic responses to incremental and self-paced exercise in COPD: a comparison of three tests. Chest 126:766–773CrossRefPubMed Turner SE, Eastwood PR, Cecins NM, Hillman DR, Jenkins SC (2004) Physiologic responses to incremental and self-paced exercise in COPD: a comparison of three tests. Chest 126:766–773CrossRefPubMed
Zurück zum Zitat Van Ravenswaaij-Arts CMA, Kollee LAA, Hopman JCW, Stoelinga GBA, van Geijn HP (1993) Heart rate variability. Ann Intern Med 118:436–447PubMed Van Ravenswaaij-Arts CMA, Kollee LAA, Hopman JCW, Stoelinga GBA, van Geijn HP (1993) Heart rate variability. Ann Intern Med 118:436–447PubMed
Zurück zum Zitat Vanderlei LC, Silva RA, Pastre CM, Azevedo FM, Godoy MF (2008) Comparison of the Polar S810i monitor and the ECG for the analysis of heart rate variability in the time and frequency domains. Braz J Med Biol Res 41:854–859CrossRefPubMed Vanderlei LC, Silva RA, Pastre CM, Azevedo FM, Godoy MF (2008) Comparison of the Polar S810i monitor and the ECG for the analysis of heart rate variability in the time and frequency domains. Braz J Med Biol Res 41:854–859CrossRefPubMed
Zurück zum Zitat Verlinde D, Beckers F, Ramaekers D, Aubert AE (2001) Wavelet decomposition analysis of heart rate variability in aerobic athletes. Auton Neurosci 90:138–141CrossRefPubMed Verlinde D, Beckers F, Ramaekers D, Aubert AE (2001) Wavelet decomposition analysis of heart rate variability in aerobic athletes. Auton Neurosci 90:138–141CrossRefPubMed
Zurück zum Zitat Wirtz PH, Elsenbruch S, Emini L, Rüdisüli K, Groessbauer S, Ehlert U (2007) Perfectionism and the cortisol response to psychosocial stress in men. Psychosom Med 69:249–255CrossRefPubMed Wirtz PH, Elsenbruch S, Emini L, Rüdisüli K, Groessbauer S, Ehlert U (2007) Perfectionism and the cortisol response to psychosocial stress in men. Psychosom Med 69:249–255CrossRefPubMed
Zurück zum Zitat Zhang JQ, Ji LL, Fogt DL, Fretwell VS (2007) Effect of exercise duration on postprandial hypertriglyceridemia in men with metabolic syndrome. J Appl Physiol 103:1339–1345CrossRefPubMed Zhang JQ, Ji LL, Fogt DL, Fretwell VS (2007) Effect of exercise duration on postprandial hypertriglyceridemia in men with metabolic syndrome. J Appl Physiol 103:1339–1345CrossRefPubMed
Zurück zum Zitat Zhong Y, Jan KM, Ju KH, Chon KH (2006) Quantifying cardiac sympathetic and parasympathetic nervous activities using principal dynamic modes analysis of heart rate variability. Am J Physiol Heart Circ Physiol 291:1475–1483CrossRef Zhong Y, Jan KM, Ju KH, Chon KH (2006) Quantifying cardiac sympathetic and parasympathetic nervous activities using principal dynamic modes analysis of heart rate variability. Am J Physiol Heart Circ Physiol 291:1475–1483CrossRef
Zurück zum Zitat Ziemssen T, Gasch J, Ruediger H (2008) Influence of ECG sampling frequency on spectral analysis of RR intervals and baroreflex sensitivity using the EUROBAVAR data set. J Clin Monit Comput 22:159–168CrossRefPubMed Ziemssen T, Gasch J, Ruediger H (2008) Influence of ECG sampling frequency on spectral analysis of RR intervals and baroreflex sensitivity using the EUROBAVAR data set. J Clin Monit Comput 22:159–168CrossRefPubMed
Metadaten
Titel
Comparison of three mobile devices for measuring R–R intervals and heart rate variability: Polar S810i, Suunto t6 and an ambulatory ECG system
verfasst von
Matthias Weippert
Mohit Kumar
Steffi Kreuzfeld
Dagmar Arndt
Annika Rieger
Regina Stoll
Publikationsdatum
01.07.2010
Verlag
Springer-Verlag
Erschienen in
European Journal of Applied Physiology / Ausgabe 4/2010
Print ISSN: 1439-6319
Elektronische ISSN: 1439-6327
DOI
https://doi.org/10.1007/s00421-010-1415-9

Weitere Artikel der Ausgabe 4/2010

European Journal of Applied Physiology 4/2010 Zur Ausgabe