Skip to main content
Erschienen in: European Journal of Applied Physiology 1/2012

01.01.2012 | Original Article

The validity of two Omron pedometers during treadmill walking is speed dependent

verfasst von: Dimitra M. Giannakidou, Antonis Kambas, Nikolaos Ageloussis, Ioannis Fatouros, Christos Christoforidis, Fotini Venetsanou, Ioannis Douroudos, Kyriakos Taxildaris

Erschienen in: European Journal of Applied Physiology | Ausgabe 1/2012

Einloggen, um Zugang zu erhalten

Abstract

The purpose of this study was to examine the effects of walking speed on the accuracy of measurement of steps, distance, and energy expenditure of two commercially available Omron pedometers [HJ-720IT-E2 (HJ-720) and HJ-113-E (HJ-113)]. Twenty-four untrained males (age, 22.7 ± 2.8 years; BMI, 24.38 ± 2.19 kg m−2; body fat (%), 16 ± 2.2; VO2max, 40.2 ± 6.5 ml kg−1 min−1) and 18 females (age, 22.4 ± 2.9 years; BMI, 21.68 ± 2.43 kg m−2; body fat (%), 23% ± 1.8; VO2max, 35.9 ± 2.8 ml kg−1 min−1) walked at five different velocities (54, 67, 80, 94 and 107 m min−1) on a treadmill in 5-min stages while wearing three types of pedometers: (a) HJ-720, (b) HJ-113, and (c) Yamax Digi-Walker SW-200 (YAM). Step-count for each pedometer was recorded at the end of each stage and compared with the value of a hand counter. Additionally, Omron pedometers were evaluated on their distance and energy expenditure (against VO2 measurement with a gas-exchange analyzer) accuracy during each stage. HJ-720 and HJ-113 demonstrated high accuracy (r = 0.80–0.99) at all speeds. YAM underestimated step-count only at 54 m min−1 (r = 0.46). HJ-720 and HJ-113 overestimated distance at slower speeds and underestimated distance at faster speeds, providing mean distance values that where to within 1.5–4% at 80 m min−1. HJ-720 and HJ-113 underestimated energy expenditure (gross kilocalories) by 28%, when compared to indirect calorimetry. These results suggest that although the Omron HJ-720 and HJ-113 pedometers are accurate in the measurement of step-count, they demonstrate limited accuracy in the assessment of traveled distance and energy expenditure in a speed-dependent manner.
Literatur
Zurück zum Zitat American College of Sports Medicine (2000) ACSM’s guidelines for exercise testing and prescription, 6th edn. Philadelphia, Lippincott Williams and Wilkins, pp 5–7 American College of Sports Medicine (2000) ACSM’s guidelines for exercise testing and prescription, 6th edn. Philadelphia, Lippincott Williams and Wilkins, pp 5–7
Zurück zum Zitat Ayabe M, Aoki J, Ishii K, Takayama K, Tanaka H (2008) Pedometer accuracy during stair climbing and bench stepping exercises. J Sports Sci Med 7:249–254 Ayabe M, Aoki J, Ishii K, Takayama K, Tanaka H (2008) Pedometer accuracy during stair climbing and bench stepping exercises. J Sports Sci Med 7:249–254
Zurück zum Zitat Basset DR, Ainsworth BE, Leggett SR (1996) Accuracy of five electronic pedometers for measuring distance walked. Med Sci Sports Exerc 28:1071–1077CrossRef Basset DR, Ainsworth BE, Leggett SR (1996) Accuracy of five electronic pedometers for measuring distance walked. Med Sci Sports Exerc 28:1071–1077CrossRef
Zurück zum Zitat Basset DR, Ainsworth BE, Swartz AM, Strath SJ, O’Brien WL, King GA (2000) Validity of four motion sensors in measuring moderate intensity physical activity. Med Sci Sports Exerc 32:S471–S480CrossRef Basset DR, Ainsworth BE, Swartz AM, Strath SJ, O’Brien WL, King GA (2000) Validity of four motion sensors in measuring moderate intensity physical activity. Med Sci Sports Exerc 32:S471–S480CrossRef
Zurück zum Zitat Bassett DR Jr, Mahar MT, Rowe DA, Morrow JR Jr (2008) Walking and measurement. Med Sci Sports Exerc 40(7S):S529–S536PubMed Bassett DR Jr, Mahar MT, Rowe DA, Morrow JR Jr (2008) Walking and measurement. Med Sci Sports Exerc 40(7S):S529–S536PubMed
Zurück zum Zitat Beets MW, Patton MM, Edwards S (2005) The accuracy of pedometers steps and time during walking in children. Med Sci Sports Exerc 37:513–520PubMedCrossRef Beets MW, Patton MM, Edwards S (2005) The accuracy of pedometers steps and time during walking in children. Med Sci Sports Exerc 37:513–520PubMedCrossRef
Zurück zum Zitat Corder K, Brage S, Wareham NJ, Ekelund U (2007) Accelerometers and pedometers: methodology and clinical application. Curr Opin Clin Nutr Metab Care 10:597–603PubMedCrossRef Corder K, Brage S, Wareham NJ, Ekelund U (2007) Accelerometers and pedometers: methodology and clinical application. Curr Opin Clin Nutr Metab Care 10:597–603PubMedCrossRef
Zurück zum Zitat Craig CL, Cameron C, Griffiths JM, Tudor-Locke C (2010a) Descriptive epidemiology of youth pedometer-determined physical activity: Canplay. Med Sci Sports Exerc. 42(9):1639–1643PubMedCrossRef Craig CL, Cameron C, Griffiths JM, Tudor-Locke C (2010a) Descriptive epidemiology of youth pedometer-determined physical activity: Canplay. Med Sci Sports Exerc. 42(9):1639–1643PubMedCrossRef
Zurück zum Zitat Craig CL, Tudor-Locke C, Cragg S, Cameron C (2010b) Process and treatment of pedometer data collection for youth: the Canadian physical activity levels among youth study. Med Sci Sports Exerc. 42(3):430–435PubMedCrossRef Craig CL, Tudor-Locke C, Cragg S, Cameron C (2010b) Process and treatment of pedometer data collection for youth: the Canadian physical activity levels among youth study. Med Sci Sports Exerc. 42(3):430–435PubMedCrossRef
Zurück zum Zitat Crouter SE, Schneider PL, Karabulut M, Basset DR Jr (2003) Validity of 10 electronic pedometers for measuring steps, distance, and energy cost. Med Sci Sports Exerc 8:1455–1460CrossRef Crouter SE, Schneider PL, Karabulut M, Basset DR Jr (2003) Validity of 10 electronic pedometers for measuring steps, distance, and energy cost. Med Sci Sports Exerc 8:1455–1460CrossRef
Zurück zum Zitat Crouter SE, Schneider PL, Basset DR Jr (2005) Spring-levered versus piezo-electric pedometer accuracy in overweight and obese adults. Med Sci Sports Exerc 37(11):1673–1679PubMedCrossRef Crouter SE, Schneider PL, Basset DR Jr (2005) Spring-levered versus piezo-electric pedometer accuracy in overweight and obese adults. Med Sci Sports Exerc 37(11):1673–1679PubMedCrossRef
Zurück zum Zitat De Vries SI, Van Hirtum WJEM, Bekker I, Hopman-Rock M, Hirasing RA, Van Mechellen W (2009) Validity and reproducibility of motion sensors in youth: a systematic update. Med Sci Sports Exerc. 41(4):818–827PubMedCrossRef De Vries SI, Van Hirtum WJEM, Bekker I, Hopman-Rock M, Hirasing RA, Van Mechellen W (2009) Validity and reproducibility of motion sensors in youth: a systematic update. Med Sci Sports Exerc. 41(4):818–827PubMedCrossRef
Zurück zum Zitat Doyle JAG, Michael S, Corona BT, Simone J, Dennison DA (2007) Validation of an electronic pedometer in a field-based setting. Med Sci Sports Exerc 39(5):S186 Doyle JAG, Michael S, Corona BT, Simone J, Dennison DA (2007) Validation of an electronic pedometer in a field-based setting. Med Sci Sports Exerc 39(5):S186
Zurück zum Zitat Fatouros IG, Tournis S, Leontsini D, Jamurtas AZ, Sxina M, Thomakos P, Manousaki M, Douroudos I, Taxildaris K, Mitrakou A (2005) Leptin and adiponectin responses in overweight inactive elderly following resistance training and detraining are intensity-related. J Clin Endocrinol Metabol. 90:5970–5977CrossRef Fatouros IG, Tournis S, Leontsini D, Jamurtas AZ, Sxina M, Thomakos P, Manousaki M, Douroudos I, Taxildaris K, Mitrakou A (2005) Leptin and adiponectin responses in overweight inactive elderly following resistance training and detraining are intensity-related. J Clin Endocrinol Metabol. 90:5970–5977CrossRef
Zurück zum Zitat Hasson RE, Jeannie H, Pober DM, Staudenmayer J, Freedson PT (2009) Validity of the Omron HJ-112 pedometer during treadmill walking. Med Sci Sports Exerc 41(4):805–809PubMedCrossRef Hasson RE, Jeannie H, Pober DM, Staudenmayer J, Freedson PT (2009) Validity of the Omron HJ-112 pedometer during treadmill walking. Med Sci Sports Exerc 41(4):805–809PubMedCrossRef
Zurück zum Zitat Hatano Y (1993) Use of the pedometer for promoting daily waking exercise. Int Council Health Phys Educ Recreat 29:4–8 Hatano Y (1993) Use of the pedometer for promoting daily waking exercise. Int Council Health Phys Educ Recreat 29:4–8
Zurück zum Zitat Hatano Y (1997) Prevelance and use of pedometer. Res J Walk 1:45–54 Hatano Y (1997) Prevelance and use of pedometer. Res J Walk 1:45–54
Zurück zum Zitat Hendelman D, Miller K, Baggett C, Debold E, Freedson P (2000) Validity of accelerometry for the assessment of moderate intensity physical activity in the field. Med Sci Sports Exerc 32:1320–1326CrossRef Hendelman D, Miller K, Baggett C, Debold E, Freedson P (2000) Validity of accelerometry for the assessment of moderate intensity physical activity in the field. Med Sci Sports Exerc 32:1320–1326CrossRef
Zurück zum Zitat Holbrook EA, Barreira TV, Kang M (2009) Validity and reliability of Omron pedometers for prescribed and self-paced walking. Med Sci Sports Exerc. 41(3):669–673 Holbrook EA, Barreira TV, Kang M (2009) Validity and reliability of Omron pedometers for prescribed and self-paced walking. Med Sci Sports Exerc. 41(3):669–673
Zurück zum Zitat Karabulut M, Crouter SE (2005) Comparison of two waist mounted and two ankle mounted electronic pedometers. Eur J Appl Physiol 95:335–343PubMedCrossRef Karabulut M, Crouter SE (2005) Comparison of two waist mounted and two ankle mounted electronic pedometers. Eur J Appl Physiol 95:335–343PubMedCrossRef
Zurück zum Zitat Katzmarzyk PT, Church TS, Blair SN (2004) Cardiorespiratory fitness attenuates the effects of the metabolic syndrome on all-cause and cardiovascular disease mortality in men. Arch Intern Med. 164:1092–1097PubMedCrossRef Katzmarzyk PT, Church TS, Blair SN (2004) Cardiorespiratory fitness attenuates the effects of the metabolic syndrome on all-cause and cardiovascular disease mortality in men. Arch Intern Med. 164:1092–1097PubMedCrossRef
Zurück zum Zitat Le Masurier GC, Tudor-Locke C (2003) Comparison of pedometer and accelerometer accuracy under controlled conditions. Med Sci Sports Exerc 35(5):867–871PubMedCrossRef Le Masurier GC, Tudor-Locke C (2003) Comparison of pedometer and accelerometer accuracy under controlled conditions. Med Sci Sports Exerc 35(5):867–871PubMedCrossRef
Zurück zum Zitat Le Masurier G, Lee SM, Tudor-Locke C (2004) Motion sensor accuracy under controlled and free-living conditions. Med Sci Sports Exerc. 36(5):905–910PubMedCrossRef Le Masurier G, Lee SM, Tudor-Locke C (2004) Motion sensor accuracy under controlled and free-living conditions. Med Sci Sports Exerc. 36(5):905–910PubMedCrossRef
Zurück zum Zitat Malm C, Nyberg P, Engstrom M, Sjodin B, Lenkei R, Ekblom B, Lundberg I (2000) Immunological changes in human skeletal muscle and blood after eccentric exercise and multiple biopsies. J Physiol 529:243–262PubMedCrossRef Malm C, Nyberg P, Engstrom M, Sjodin B, Lenkei R, Ekblom B, Lundberg I (2000) Immunological changes in human skeletal muscle and blood after eccentric exercise and multiple biopsies. J Physiol 529:243–262PubMedCrossRef
Zurück zum Zitat Melanson E, Knoll J, Bell M (2004) Commercially available pedometers: considerations for accurate step counting. Prev Med 39:361–368PubMedCrossRef Melanson E, Knoll J, Bell M (2004) Commercially available pedometers: considerations for accurate step counting. Prev Med 39:361–368PubMedCrossRef
Zurück zum Zitat Nakae S, Oshima Y, Ishii K (2008) Accuracy of spring levered and piezo-electric pedometers in primary school Japanese children. J Physiol Anthropol 27(5):233–239PubMedCrossRef Nakae S, Oshima Y, Ishii K (2008) Accuracy of spring levered and piezo-electric pedometers in primary school Japanese children. J Physiol Anthropol 27(5):233–239PubMedCrossRef
Zurück zum Zitat Nelson TE, Leenders NY, Sherman WM (1998) Comparison of activity monitors worn during treadmill walking. Med Sci Sports Exerc 30(5):11 (abstract) Nelson TE, Leenders NY, Sherman WM (1998) Comparison of activity monitors worn during treadmill walking. Med Sci Sports Exerc 30(5):11 (abstract)
Zurück zum Zitat Rafferty AP, Reeves MJ, McGee HB, Pivarnik JM (2002) Physical activity patterns among walkers and compliance with public health recommendations. Med Sci Sports Exerc. 34(8):1255–1261PubMedCrossRef Rafferty AP, Reeves MJ, McGee HB, Pivarnik JM (2002) Physical activity patterns among walkers and compliance with public health recommendations. Med Sci Sports Exerc. 34(8):1255–1261PubMedCrossRef
Zurück zum Zitat Rossiter HB, Kowalchuk JM, Whipp BJ (2006) A test to establish maximum O2 uptake despite no plateau in the O2 uptake response to ramp incremental exercise. J Appl Physiol 100:764–770PubMedCrossRef Rossiter HB, Kowalchuk JM, Whipp BJ (2006) A test to establish maximum O2 uptake despite no plateau in the O2 uptake response to ramp incremental exercise. J Appl Physiol 100:764–770PubMedCrossRef
Zurück zum Zitat Rowlands AV, Stone MR, Eston RG (2007) Influence of speed and step frequency during walking and running on motion sensor output. Med Sci Sports Exerc. 39(4):716–727PubMedCrossRef Rowlands AV, Stone MR, Eston RG (2007) Influence of speed and step frequency during walking and running on motion sensor output. Med Sci Sports Exerc. 39(4):716–727PubMedCrossRef
Zurück zum Zitat Schneider PL, Crouter SE, Lukajic O, Basset DR (2003) Accuracy and reliability of 10 pedometers for measuring steps over a 400-m walk. Med Sci Sports Exerc 10:1779–1784CrossRef Schneider PL, Crouter SE, Lukajic O, Basset DR (2003) Accuracy and reliability of 10 pedometers for measuring steps over a 400-m walk. Med Sci Sports Exerc 10:1779–1784CrossRef
Zurück zum Zitat Schneider PL, Crouter SE, Basset DR (2004) Pedometer measures of free-living physical activity: comparison of 13 models. Med Sci Sports Exerc 2:331–335CrossRef Schneider PL, Crouter SE, Basset DR (2004) Pedometer measures of free-living physical activity: comparison of 13 models. Med Sci Sports Exerc 2:331–335CrossRef
Zurück zum Zitat Shepherd FE, Toloza E, McClung DC, Schmalzried PT (1999) Step activity monitor: increased accuracy in quantifying ambulatory activity. J Orthop Res 17:703–708PubMedCrossRef Shepherd FE, Toloza E, McClung DC, Schmalzried PT (1999) Step activity monitor: increased accuracy in quantifying ambulatory activity. J Orthop Res 17:703–708PubMedCrossRef
Zurück zum Zitat Sidak Z (1967) Rectangular confidence regions for the means of multivariate normal distributions. J Am Stat Assoc 62:626–633CrossRef Sidak Z (1967) Rectangular confidence regions for the means of multivariate normal distributions. J Am Stat Assoc 62:626–633CrossRef
Zurück zum Zitat Swartz AM, Strath SJ, Miller NE, Grimm EK, Ewalt LA, Loy MS, Gennuso KP (2009) Validity of physical activity monitors in assessing energy expenditure in normal, overweight, and obese adults. Open Sports Sci J. 2:58–64PubMedCrossRef Swartz AM, Strath SJ, Miller NE, Grimm EK, Ewalt LA, Loy MS, Gennuso KP (2009) Validity of physical activity monitors in assessing energy expenditure in normal, overweight, and obese adults. Open Sports Sci J. 2:58–64PubMedCrossRef
Zurück zum Zitat Tudor-Locke CE, Myers AM (2001) Methodological considerations for researchers and practitioners using pedometers to measure physical (ambulatory) activity. Res Q Exerc Sport 72:1–12PubMed Tudor-Locke CE, Myers AM (2001) Methodological considerations for researchers and practitioners using pedometers to measure physical (ambulatory) activity. Res Q Exerc Sport 72:1–12PubMed
Zurück zum Zitat Tudor-Locke CE, Williams J, Reis J, Pluto D (2002) Utility of pedometers for assessing physical activity. Convergent validity. Sports Med 32:795–808PubMedCrossRef Tudor-Locke CE, Williams J, Reis J, Pluto D (2002) Utility of pedometers for assessing physical activity. Convergent validity. Sports Med 32:795–808PubMedCrossRef
Zurück zum Zitat Tudor-Locke C, Sisson SB, Lee SM, Swan PD (2005) Pedometer-determined step count guidelines for classifying walking intensity in a young ostensibly healthy population. Can J Appl Physiol 30(6):666–676PubMedCrossRef Tudor-Locke C, Sisson SB, Lee SM, Swan PD (2005) Pedometer-determined step count guidelines for classifying walking intensity in a young ostensibly healthy population. Can J Appl Physiol 30(6):666–676PubMedCrossRef
Zurück zum Zitat US Department of Health and Human Services (1996) Physical activity and health: a report of the surgeon general. US Department of Health and Human Services, Centers for Disease Control and Prevention, National Center for Chronic Disease Prevention and Promotion, Atlanta, GA US Department of Health and Human Services (1996) Physical activity and health: a report of the surgeon general. US Department of Health and Human Services, Centers for Disease Control and Prevention, National Center for Chronic Disease Prevention and Promotion, Atlanta, GA
Zurück zum Zitat Welk GJ, Differding JA, Thompson RW, Blair SN, Dziura J, Hart P (2000) The utility of the Digi-Walker step counter to assess daily physical activity patterns. Med Sci Sports Exerc 32(9 Suppl):S481–S448 Welk GJ, Differding JA, Thompson RW, Blair SN, Dziura J, Hart P (2000) The utility of the Digi-Walker step counter to assess daily physical activity patterns. Med Sci Sports Exerc 32(9 Suppl):S481–S448
Metadaten
Titel
The validity of two Omron pedometers during treadmill walking is speed dependent
verfasst von
Dimitra M. Giannakidou
Antonis Kambas
Nikolaos Ageloussis
Ioannis Fatouros
Christos Christoforidis
Fotini Venetsanou
Ioannis Douroudos
Kyriakos Taxildaris
Publikationsdatum
01.01.2012
Verlag
Springer-Verlag
Erschienen in
European Journal of Applied Physiology / Ausgabe 1/2012
Print ISSN: 1439-6319
Elektronische ISSN: 1439-6327
DOI
https://doi.org/10.1007/s00421-011-1951-y

Weitere Artikel der Ausgabe 1/2012

European Journal of Applied Physiology 1/2012 Zur Ausgabe