Skip to main content
Erschienen in: European Journal of Applied Physiology 3/2018

22.01.2018 | Original Article

Validity of the Polar V800 monitor for measuring heart rate variability in mountain running route conditions

verfasst von: Pere Caminal, Fuensanta Sola, Pedro Gomis, Eduard Guasch, Alexandre Perera, Núria Soriano, Lluis Mont

Erschienen in: European Journal of Applied Physiology | Ausgabe 3/2018

Einloggen, um Zugang zu erhalten

Abstract

Purpose

This study was conducted to test, in mountain running route conditions, the accuracy of the Polar V800™ monitor as a suitable device for monitoring the heart rate variability (HRV) of runners.

Method

Eighteen healthy subjects ran a route that included a range of running slopes such as those encountered in trail and ultra-trail races. The comparative study of a V800 and a Holter SEER 12 ECG Recorder™ included the analysis of RR time series and short-term HRV analysis. A correction algorithm was designed to obtain the corrected Polar RR intervals. Six 5-min segments related to different running slopes were considered for each subject.

Results

The correlation between corrected V800 RR intervals and Holter RR intervals was very high (r = 0.99, p < 0.001), and the bias was less than 1 ms. The limits of agreement (LoA) obtained for SDNN and RMSSD were (− 0.25 to 0.32 ms) and (− 0.90 to 1.08 ms), respectively. The effect size (ES) obtained in the time domain HRV parameters was considered small (ES < 0.2). Frequency domain HRV parameters did not differ (p > 0.05) and were well correlated (r ≥ 0.96, p < 0.001).

Conclusion

Narrow limits of agreement, high correlations and small effect size suggest that the Polar V800 is a valid tool for the analysis of heart rate variability in athletes while running high endurance events such as marathon, trail, and ultra-trail races.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
Zurück zum Zitat Arai Y, Saul JP, Albrecht P et al (1989) Modulation of cardiac autonomic activity during and immediately after exercise. Am J Physiol 256:H132–H141PubMed Arai Y, Saul JP, Albrecht P et al (1989) Modulation of cardiac autonomic activity during and immediately after exercise. Am J Physiol 256:H132–H141PubMed
Zurück zum Zitat Aubert A, Seps B, Beckers F (2003) Heart rate variability in athletes. Sports Med 33(12):889–919CrossRefPubMed Aubert A, Seps B, Beckers F (2003) Heart rate variability in athletes. Sports Med 33(12):889–919CrossRefPubMed
Zurück zum Zitat Bland JM, Altman DG (2007) Agreement between methods of measurement with multiple observations per individual. J Biopharmaceut Stat 17:571–582CrossRef Bland JM, Altman DG (2007) Agreement between methods of measurement with multiple observations per individual. J Biopharmaceut Stat 17:571–582CrossRef
Zurück zum Zitat Boardman A, Schlindwein F, Rocha A, Leite A (2002) A study on the optimum order of autoregressive models for heart rate variability. Physiol Meas 23(2):325–336CrossRefPubMed Boardman A, Schlindwein F, Rocha A, Leite A (2002) A study on the optimum order of autoregressive models for heart rate variability. Physiol Meas 23(2):325–336CrossRefPubMed
Zurück zum Zitat Broersen P (2000) Finite sample criteria for autoregressive order selection. IEEE Trans Signal Process 48(12):3550–3558CrossRef Broersen P (2000) Finite sample criteria for autoregressive order selection. IEEE Trans Signal Process 48(12):3550–3558CrossRef
Zurück zum Zitat Burg JP (1975) Maximum entropy spectral analysis. Dissertation, Stanford University Burg JP (1975) Maximum entropy spectral analysis. Dissertation, Stanford University
Zurück zum Zitat Cohen J (1988) Statistical power analysis for the behavioral sciences. Lawrence Eribaum Associates, Hillsdale Cohen J (1988) Statistical power analysis for the behavioral sciences. Lawrence Eribaum Associates, Hillsdale
Zurück zum Zitat Furlan R, Piazza S, Dell’Orto S et al (1993) Early and late effects of exercise and athletic training on neural mechanisms controlling heart rate. Cardiovasc Res 27:482–488CrossRefPubMed Furlan R, Piazza S, Dell’Orto S et al (1993) Early and late effects of exercise and athletic training on neural mechanisms controlling heart rate. Cardiovasc Res 27:482–488CrossRefPubMed
Zurück zum Zitat Gamelin FX, Bosquet L, Berthoin S (2006) Validity of the Polar S810 heart rate monitor to measure R–R intervals at rest. Med Sci Sports Exerc 38(5):887–893CrossRefPubMed Gamelin FX, Bosquet L, Berthoin S (2006) Validity of the Polar S810 heart rate monitor to measure R–R intervals at rest. Med Sci Sports Exerc 38(5):887–893CrossRefPubMed
Zurück zum Zitat Gamelin FX, Baquet G, Berthoin S, Bosquet L (2008) Validity of the Polar S810 to measure R–R intervals in children. Int J Sports Med 29:134–138CrossRefPubMed Gamelin FX, Baquet G, Berthoin S, Bosquet L (2008) Validity of the Polar S810 to measure R–R intervals in children. Int J Sports Med 29:134–138CrossRefPubMed
Zurück zum Zitat Giavarina D (2015) Understanding Bland Altman analysis. Biochem Med 25(2):141–151CrossRef Giavarina D (2015) Understanding Bland Altman analysis. Biochem Med 25(2):141–151CrossRef
Zurück zum Zitat Giles D, Draper N, Neil W (2016) Validity of the Polar V800 heart rate monitor to measure RR intervals at rest. Eur J Appl Physiol 116:563–571CrossRefPubMed Giles D, Draper N, Neil W (2016) Validity of the Polar V800 heart rate monitor to measure RR intervals at rest. Eur J Appl Physiol 116:563–571CrossRefPubMed
Zurück zum Zitat Gomis P, Caminal P, Vallverdú M, Warren S, Stein P, Wagner G (2012) Assessment of autonomic control of the heart during transient myocardial ischemia. J Electrocardiol 45(1):82–89CrossRefPubMed Gomis P, Caminal P, Vallverdú M, Warren S, Stein P, Wagner G (2012) Assessment of autonomic control of the heart during transient myocardial ischemia. J Electrocardiol 45(1):82–89CrossRefPubMed
Zurück zum Zitat Hynynen E, Uusitalo A, Konttinen N, Rusko H (2006) Heart rate variability during night sleep and after awakening in overtrained athletes. Med Sci Sports Exerc 38(2):313–317CrossRefPubMed Hynynen E, Uusitalo A, Konttinen N, Rusko H (2006) Heart rate variability during night sleep and after awakening in overtrained athletes. Med Sci Sports Exerc 38(2):313–317CrossRefPubMed
Zurück zum Zitat Kingsley M, Lewis M, Marson R (2005) Comparison of Polar 810S and an ambulatory ECG system for RR interval measurement during progressive exercise. Int J Sports Med 26(01/02):39–44CrossRefPubMed Kingsley M, Lewis M, Marson R (2005) Comparison of Polar 810S and an ambulatory ECG system for RR interval measurement during progressive exercise. Int J Sports Med 26(01/02):39–44CrossRefPubMed
Zurück zum Zitat Mainardi L (2009) On the quantification of heart rate variability spectral parameters using time–frequency and time-varying methods. Philos Trans R Soc A 367:255–275CrossRef Mainardi L (2009) On the quantification of heart rate variability spectral parameters using time–frequency and time-varying methods. Philos Trans R Soc A 367:255–275CrossRef
Zurück zum Zitat Mateo J, Serrano P, Bailón R et al (2001) Heart rate variability measurements during exercise test may improve the diagnosis of ischemic heart disease. Proc 23rd Ann Int Conf IEEE 503–506 Mateo J, Serrano P, Bailón R et al (2001) Heart rate variability measurements during exercise test may improve the diagnosis of ischemic heart disease. Proc 23rd Ann Int Conf IEEE 503–506
Zurück zum Zitat Melia U, Roca E, Brotons et al (2014) Heart rate variability in ultra-trail runners. Comput Cardiol 41:997–1000 Melia U, Roca E, Brotons et al (2014) Heart rate variability in ultra-trail runners. Comput Cardiol 41:997–1000
Zurück zum Zitat Nunan D, Jakovljevic D, Donovan G, Hodges L, Sandercock G, Brodie D (2008) Levels of agreement for RR intervals and short-term heart rate variability obtained from the Polar S810 and an alternative system. Eur J Appl Physiol 103(5):529–537CrossRefPubMed Nunan D, Jakovljevic D, Donovan G, Hodges L, Sandercock G, Brodie D (2008) Levels of agreement for RR intervals and short-term heart rate variability obtained from the Polar S810 and an alternative system. Eur J Appl Physiol 103(5):529–537CrossRefPubMed
Zurück zum Zitat Nunan D, Donovan G, Jakovljevic D, Hodges L, Sandercock G. Brodie D (2009) Validity and reliability of short-term heart-rate variability from the Polar S810. Med Sci Sports Exerc 41(1):243–250CrossRefPubMed Nunan D, Donovan G, Jakovljevic D, Hodges L, Sandercock G. Brodie D (2009) Validity and reliability of short-term heart-rate variability from the Polar S810. Med Sci Sports Exerc 41(1):243–250CrossRefPubMed
Zurück zum Zitat O’Connor GT, Buring JE, Yusuf S et al (1989) An overview of randomized trials of rehabilitation with exercise after myocardial infarction. Circulation 80:234–244CrossRefPubMed O’Connor GT, Buring JE, Yusuf S et al (1989) An overview of randomized trials of rehabilitation with exercise after myocardial infarction. Circulation 80:234–244CrossRefPubMed
Zurück zum Zitat Pichot V, Roche F, Gaspoz JM et al (2000) Relation between heart rate variability and training load in middle-distance runners. Med Sci Sports Exerc 32(10):1729–1736CrossRefPubMed Pichot V, Roche F, Gaspoz JM et al (2000) Relation between heart rate variability and training load in middle-distance runners. Med Sci Sports Exerc 32(10):1729–1736CrossRefPubMed
Zurück zum Zitat Plews D, Laursen P, Stanley J, Kilding A, Buchheit M (2013) Training adaptation and heart rate variability in elite endurance athletes: opening the door to effective monitoring. Sports Med 43(9):773–781CrossRefPubMed Plews D, Laursen P, Stanley J, Kilding A, Buchheit M (2013) Training adaptation and heart rate variability in elite endurance athletes: opening the door to effective monitoring. Sports Med 43(9):773–781CrossRefPubMed
Zurück zum Zitat Porto LGG, Junqueira J (2009) Comparison of time-domain short-term heart interval variability analysis using a wrist-worn heart rate monitor and the conventional electrocardiogram. Pacing Clin Electrophysiol 32:43–51CrossRefPubMed Porto LGG, Junqueira J (2009) Comparison of time-domain short-term heart interval variability analysis using a wrist-worn heart rate monitor and the conventional electrocardiogram. Pacing Clin Electrophysiol 32:43–51CrossRefPubMed
Zurück zum Zitat Radespiel-Tröger M, Rauh R, Mahlke C, Gottschalk T, Mück-Weymann M (2003) Agreement of two different methods for measurement of heart rate variability. Clin Auton Res 13(2):99–102CrossRefPubMed Radespiel-Tröger M, Rauh R, Mahlke C, Gottschalk T, Mück-Weymann M (2003) Agreement of two different methods for measurement of heart rate variability. Clin Auton Res 13(2):99–102CrossRefPubMed
Zurück zum Zitat Rocha AP, Almeida R, Leite A, Silva MJ, Silva ME (2014) Long-term HRV in critically ill pediatric patients: coma versus brain death. Comput Cardiol 41:89–92 Rocha AP, Almeida R, Leite A, Silva MJ, Silva ME (2014) Long-term HRV in critically ill pediatric patients: coma versus brain death. Comput Cardiol 41:89–92
Zurück zum Zitat Ruha A, Sallinen S, Nissila S (1997) A real-time microprocessor QRS detector with a 1-ms timing accuracy for the measurement of ambulatory HRV. IEEE Trans Biomed Eng 44:159–167CrossRefPubMed Ruha A, Sallinen S, Nissila S (1997) A real-time microprocessor QRS detector with a 1-ms timing accuracy for the measurement of ambulatory HRV. IEEE Trans Biomed Eng 44:159–167CrossRefPubMed
Zurück zum Zitat Sumi K, Suzuki S, Matsubara M, Ando Y, Kobayashi F (2006) Heart rate variability during high-intensity field exercise in female distance runners. Scand J Med Sci Sports 16(5):314–320CrossRefPubMed Sumi K, Suzuki S, Matsubara M, Ando Y, Kobayashi F (2006) Heart rate variability during high-intensity field exercise in female distance runners. Scand J Med Sci Sports 16(5):314–320CrossRefPubMed
Zurück zum Zitat Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology (1996) Heart rate variability: standards of measurement, physiological interpretation and clinical use. Circulation 93: 1043–1065CrossRef Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology (1996) Heart rate variability: standards of measurement, physiological interpretation and clinical use. Circulation 93: 1043–1065CrossRef
Zurück zum Zitat Thomas JR, Nelson JK, Silverman SJ (2015) Research methods in physical activity. Human Kinetics Publishers, Champaign Thomas JR, Nelson JK, Silverman SJ (2015) Research methods in physical activity. Human Kinetics Publishers, Champaign
Zurück zum Zitat Vanderlei L, Silva R, Pastre C, Azevedo F, Godoy M (2008) Comparison of the Polar S810i monitor and the ECG for the analysis of heart rate variability in the time and frequency domains. Braz J Med Biol Res 41(10):854–859CrossRefPubMed Vanderlei L, Silva R, Pastre C, Azevedo F, Godoy M (2008) Comparison of the Polar S810i monitor and the ECG for the analysis of heart rate variability in the time and frequency domains. Braz J Med Biol Res 41(10):854–859CrossRefPubMed
Zurück zum Zitat Voss A, Schroeder R, Vallverdú M, Schulz et al (2013) Short-term vs long-term heart rate variability in ischemic cardiomyopathy risk stratification. Front Physiol 4:364–380CrossRefPubMedPubMedCentral Voss A, Schroeder R, Vallverdú M, Schulz et al (2013) Short-term vs long-term heart rate variability in ischemic cardiomyopathy risk stratification. Front Physiol 4:364–380CrossRefPubMedPubMedCentral
Zurück zum Zitat Voss A, Schroeder R, Heitmann A, Peters A, Perz S (2015) Short-term heart rate variability. Influence of gender and age in healthy subjects. PLoS One 10(3):e0118308CrossRefPubMedPubMedCentral Voss A, Schroeder R, Heitmann A, Peters A, Perz S (2015) Short-term heart rate variability. Influence of gender and age in healthy subjects. PLoS One 10(3):e0118308CrossRefPubMedPubMedCentral
Zurück zum Zitat Wallén MB, Hasson D, Theorell T, Canlon B, Osika W (2012) Possibilities and limitations of the polar RS800 in measuring heart rate variability at rest. Eur J Appl Physiol 112:1153–1165CrossRefPubMed Wallén MB, Hasson D, Theorell T, Canlon B, Osika W (2012) Possibilities and limitations of the polar RS800 in measuring heart rate variability at rest. Eur J Appl Physiol 112:1153–1165CrossRefPubMed
Zurück zum Zitat Weippert M, Kumar M, Kreuzfeld S, Arndt D, Rieger A, Stoll R (2010) Comparison of three mobile devices for measuring R–R intervals and heart rate variability: Polar S810i, Suunto t6 and an ambulatory ECG system. Eur J Appl Physiol 109(4):779–786CrossRefPubMed Weippert M, Kumar M, Kreuzfeld S, Arndt D, Rieger A, Stoll R (2010) Comparison of three mobile devices for measuring R–R intervals and heart rate variability: Polar S810i, Suunto t6 and an ambulatory ECG system. Eur J Appl Physiol 109(4):779–786CrossRefPubMed
Metadaten
Titel
Validity of the Polar V800 monitor for measuring heart rate variability in mountain running route conditions
verfasst von
Pere Caminal
Fuensanta Sola
Pedro Gomis
Eduard Guasch
Alexandre Perera
Núria Soriano
Lluis Mont
Publikationsdatum
22.01.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Applied Physiology / Ausgabe 3/2018
Print ISSN: 1439-6319
Elektronische ISSN: 1439-6327
DOI
https://doi.org/10.1007/s00421-018-3808-0

Weitere Artikel der Ausgabe 3/2018

European Journal of Applied Physiology 3/2018 Zur Ausgabe