Electrical impedance tomography: changes in distribution of pulmonary ventilation during laparoscopic surgery in a porcine model

verfasst von: T. Meier, T. Leibecke, C. Eckmann, U. W. Gosch, M. Grossherr, H. P. Bruch, H. Gehring, S. Leonhardt

Erschienen in: Langenbeck's Archives of Surgery | Ausgabe 4/2006

Einloggen, um Zugang zu erhalten

Abstract

Background

Because of the creation of a pneumoperitoneum, impairment of ventilation is a common side-effect during laparoscopic surgery. Electrical impedance tomography (EIT) is a method with the potential for becoming a tool to quantify these alterations during surgery. We have studied the change of regional ventilation during and after laparoscopic surgery with EIT and compared the diagnostic findings with computed tomography (CT) scans in a porcine study.

Materials and methods

After approval by the local animal ethics committee, six pigs were included in the study. Two laparoscopic operations were performed [colon resection (n=3) and fundoplicatio (n=3)]. The EIT measurements (6th parasternal intercostal space) were continuously recorded by an EIT prototype (EIT Evaluation Kit, Dräger Medical, Lübeck, Germany). To verify ventilatory alterations detected by EIT, a CT scan was performed postoperatively.

Results

Ventilation with defined tidal volumes was significantly correlated to EIT measurements (r 2=0.99). After creation of the pneumoperitoneum, lung compliance typically decreased, which agreed well with an alteration of the distribution of pulmonary ventilation measured by EIT. Elevation of positive end-inspiratory pressure reopened non-aerated lung areas and showed a recovery of the regional ventilation measured by EIT. Additionally, we could detect pulmonary complications by EIT monitoring as verified by CT scans postoperatively.

Conclusion

EIT monitoring can be used as a continuous non-invasive intraoperative monitor of ventilation to detect regional changes of ventilation and pulmonary complications during laparoscopic surgery. These EIT findings indicate that surgeons and anesthetists may eventually be able to optimize ventilation directly in the operating theatre.
Literatur
1.
Zurück zum Zitat Sharma KC, Brandstetter RD, Brensilver JM, Jung LD (1996) Cardiopulmonary physiology and pathophysiology as a consequence of laparoscopic surgery. Chest 110:810–815PubMedCrossRef Sharma KC, Brandstetter RD, Brensilver JM, Jung LD (1996) Cardiopulmonary physiology and pathophysiology as a consequence of laparoscopic surgery. Chest 110:810–815PubMedCrossRef
2.
Zurück zum Zitat Nguyen NT, Wolfe BM (2005) The physiologic effects of pneumoperitoneum in the morbidly obese. Ann Surg 241:219–226CrossRefPubMed Nguyen NT, Wolfe BM (2005) The physiologic effects of pneumoperitoneum in the morbidly obese. Ann Surg 241:219–226CrossRefPubMed
3.
Zurück zum Zitat Andersson LE, Baath M, Thorne A, Aspelin P, Odeberg-Wernerman S (2005) Effect of carbon dioxide pneumoperitoneum on development of atelectasis during anesthesia, examined by spiral computed tomography. Anesthesiology 102:293–299CrossRefPubMed Andersson LE, Baath M, Thorne A, Aspelin P, Odeberg-Wernerman S (2005) Effect of carbon dioxide pneumoperitoneum on development of atelectasis during anesthesia, examined by spiral computed tomography. Anesthesiology 102:293–299CrossRefPubMed
4.
Zurück zum Zitat Sharma KC, Kabinoff G, Ducheine Y, Tierney J, Brandstetter RD (1997) Laparoscopic surgery and its potential for medical complications. Heart Lung 26:52–64CrossRefPubMed Sharma KC, Kabinoff G, Ducheine Y, Tierney J, Brandstetter RD (1997) Laparoscopic surgery and its potential for medical complications. Heart Lung 26:52–64CrossRefPubMed
5.
Zurück zum Zitat Gutt CN, Oniu T, Mehrabi A, Schemmer P, Kashfi A, Kraus T, Buchler MW (2004) Circulatory and respiratory complications of carbon dioxide insufflation. Dig Surg 21:95–105CrossRefPubMed Gutt CN, Oniu T, Mehrabi A, Schemmer P, Kashfi A, Kraus T, Buchler MW (2004) Circulatory and respiratory complications of carbon dioxide insufflation. Dig Surg 21:95–105CrossRefPubMed
6.
Zurück zum Zitat Frerichs I, Hahn G, Golisch W, Kurpitz M, Burchardi H, Hellige G (1998) Monitoring perioperative changes in distribution of pulmonary ventilation by functional electrical impedance tomography. Acta Anaesthesiol Scand 42:721–726PubMedCrossRef Frerichs I, Hahn G, Golisch W, Kurpitz M, Burchardi H, Hellige G (1998) Monitoring perioperative changes in distribution of pulmonary ventilation by functional electrical impedance tomography. Acta Anaesthesiol Scand 42:721–726PubMedCrossRef
7.
Zurück zum Zitat Victorino JA, Borges JB, Okamoto VN, Matos GF, Tucci MR, Caramez MP, Tanaka H, Sipmann FS, Santos DC, Barbas CS, Carvalho CR, Amato MB (2004) Imbalances in regional lung ventilation: a validation study on electrical impedance tomography. Am J Respir Crit Care Med 169:791–800CrossRefPubMed Victorino JA, Borges JB, Okamoto VN, Matos GF, Tucci MR, Caramez MP, Tanaka H, Sipmann FS, Santos DC, Barbas CS, Carvalho CR, Amato MB (2004) Imbalances in regional lung ventilation: a validation study on electrical impedance tomography. Am J Respir Crit Care Med 169:791–800CrossRefPubMed
8.
Zurück zum Zitat Brown BH (2003) Electrical impedance tomography (EIT): a review. J Med Eng Technol 27:97–108CrossRefPubMed Brown BH (2003) Electrical impedance tomography (EIT): a review. J Med Eng Technol 27:97–108CrossRefPubMed
9.
Zurück zum Zitat Barber DC (1989) A review of image reconstruction techniques for electrical impedance tomography. Med Phys 16:162–169CrossRefPubMed Barber DC (1989) A review of image reconstruction techniques for electrical impedance tomography. Med Phys 16:162–169CrossRefPubMed
10.
Zurück zum Zitat Frerichs I, Hinz J, Herrmann P, Weisser G, Hahn G, Dudykevych T, Quintel M, Hellige G (2002) Detection of local lung air content by electrical impedance tomography compared with electron beam CT. J Appl Physiol 93:660–666PubMed Frerichs I, Hinz J, Herrmann P, Weisser G, Hahn G, Dudykevych T, Quintel M, Hellige G (2002) Detection of local lung air content by electrical impedance tomography compared with electron beam CT. J Appl Physiol 93:660–666PubMed
11.
Zurück zum Zitat Blue RS, Isaacson D, Newell JC (2000) Real-time three-dimensional electrical impedance imaging. Physiol Meas 21:15–26CrossRefPubMed Blue RS, Isaacson D, Newell JC (2000) Real-time three-dimensional electrical impedance imaging. Physiol Meas 21:15–26CrossRefPubMed
12.
Zurück zum Zitat Hahn G, Beer M, Frerichs I, Dudykevych T, Schroder T, Hellige G (2000) A simple method to check the dynamic performance of electrical impedance tomography systems. Physiol Meas 21:53–60CrossRefPubMed Hahn G, Beer M, Frerichs I, Dudykevych T, Schroder T, Hellige G (2000) A simple method to check the dynamic performance of electrical impedance tomography systems. Physiol Meas 21:53–60CrossRefPubMed
13.
Zurück zum Zitat Frerichs I, Hahn G, Hellige G (1999) Thoracic electrical impedance tomographic measurements during volume controlled ventilation-effects of tidal volume and positive end-expiratory pressure. IEEE Trans Med Imag 18:764–773CrossRef Frerichs I, Hahn G, Hellige G (1999) Thoracic electrical impedance tomographic measurements during volume controlled ventilation-effects of tidal volume and positive end-expiratory pressure. IEEE Trans Med Imag 18:764–773CrossRef
14.
Zurück zum Zitat Adler A, Amyot R, Guardo R, Bates JH, Berthiaume Y (1997) Monitoring changes in lung air and liquid volumes with electrical impedance tomography. J Appl Physiol 83:1762–1767PubMed Adler A, Amyot R, Guardo R, Bates JH, Berthiaume Y (1997) Monitoring changes in lung air and liquid volumes with electrical impedance tomography. J Appl Physiol 83:1762–1767PubMed
15.
Zurück zum Zitat van Genderingen HR, van Vught AJ, Jansen JR (2003) Estimation of regional lung volume changes by electrical impedance pressures tomography during a pressure-volume maneuver. Intensive Care Med 29:233–240PubMed van Genderingen HR, van Vught AJ, Jansen JR (2003) Estimation of regional lung volume changes by electrical impedance pressures tomography during a pressure-volume maneuver. Intensive Care Med 29:233–240PubMed
16.
Zurück zum Zitat Hinz J, Neumann P, Dudykevych T, Andersson LG, Wrigge H, Burchardi H, Hedenstierna G (2003) Regional ventilation by electrical impedance tomography: a comparison with ventilation scintigraphy in pigs. Chest 124:314–322CrossRefPubMed Hinz J, Neumann P, Dudykevych T, Andersson LG, Wrigge H, Burchardi H, Hedenstierna G (2003) Regional ventilation by electrical impedance tomography: a comparison with ventilation scintigraphy in pigs. Chest 124:314–322CrossRefPubMed
17.
Zurück zum Zitat Kunst PW, Vonk Noordegraaf A, Hoekstra OS, Postmus PE, de Vries PM (1998) Ventilation and perfusion imaging by electrical impedance tomography: a comparison with radionuclide scanning. Physiol Meas 19:481–490CrossRefPubMed Kunst PW, Vonk Noordegraaf A, Hoekstra OS, Postmus PE, de Vries PM (1998) Ventilation and perfusion imaging by electrical impedance tomography: a comparison with radionuclide scanning. Physiol Meas 19:481–490CrossRefPubMed
18.
Zurück zum Zitat Kunst PW, Vazquez de Anda G, Bohm SH, Faes TJ, Lachmann B, Postmus PE, de Vries PM (2000) Monitoring of recruitment and derecruitment by electrical impedance tomography in a model of acute lung injury. Crit Care Med 28:3891–3895CrossRefPubMed Kunst PW, Vazquez de Anda G, Bohm SH, Faes TJ, Lachmann B, Postmus PE, de Vries PM (2000) Monitoring of recruitment and derecruitment by electrical impedance tomography in a model of acute lung injury. Crit Care Med 28:3891–3895CrossRefPubMed
19.
Zurück zum Zitat Adler A, Shinozuka N, Berthiaume Y, Guardo R, Bates JH (1998) Electrical impedance tomography can monitor dynamic hyperinflation in dogs. J Appl Physiol 84:726–732PubMed Adler A, Shinozuka N, Berthiaume Y, Guardo R, Bates JH (1998) Electrical impedance tomography can monitor dynamic hyperinflation in dogs. J Appl Physiol 84:726–732PubMed
20.
Zurück zum Zitat Joris JL, Chiche JD, Lamy ML (1995) Pneumothorax during laparoscopic fundoplication: diagnosis and treatment with positive end-expiratory pressure. Anesth Analg 81:993–1000CrossRefPubMed Joris JL, Chiche JD, Lamy ML (1995) Pneumothorax during laparoscopic fundoplication: diagnosis and treatment with positive end-expiratory pressure. Anesth Analg 81:993–1000CrossRefPubMed
21.
Zurück zum Zitat Wolf GK, Arnold JH (2005) Noninvasive assessment of lung volume: respiratory inductance plethysmography and electrical impedance tomography. Crit Care Med 33:S163–S169CrossRefPubMed Wolf GK, Arnold JH (2005) Noninvasive assessment of lung volume: respiratory inductance plethysmography and electrical impedance tomography. Crit Care Med 33:S163–S169CrossRefPubMed
22.
Zurück zum Zitat Hahn G, Hartung C, Hellige C (1998) Elektrische Impedanztomographie (EIT) als Methode zur regionalen Beurteilung der Lungenventilaiton. Fischer, Stuttgart, p 69 Hahn G, Hartung C, Hellige C (1998) Elektrische Impedanztomographie (EIT) als Methode zur regionalen Beurteilung der Lungenventilaiton. Fischer, Stuttgart, p 69
Metadaten
Titel
Electrical impedance tomography: changes in distribution of pulmonary ventilation during laparoscopic surgery in a porcine model
verfasst von
T. Meier
T. Leibecke
C. Eckmann
U. W. Gosch
M. Grossherr
H. P. Bruch
H. Gehring
S. Leonhardt
Publikationsdatum
01.08.2006
Verlag
Springer-Verlag
Erschienen in
Langenbeck's Archives of Surgery / Ausgabe 4/2006
Print ISSN: 1435-2443
Elektronische ISSN: 1435-2451
DOI
https://doi.org/10.1007/s00423-006-0034-8

Weitere Artikel der Ausgabe 4/2006

Langenbeck's Archives of Surgery 4/2006 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

CME: 2 Punkte

Prof. Dr. med. Gregor Antoniadis Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

CME: 2 Punkte

Dr. med. Benjamin Meyknecht, PD Dr. med. Oliver Pieske Das Webinar S2e-Leitlinie „Distale Radiusfraktur“ beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

CME: 2 Punkte

Dr. med. Mihailo Andric
Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.