Abstract

Background: Previous studies have failed to establish clear advantages for the use of stereoscopic visualization systems in minimal-access surgery. The aim of this study was to objectively assess whether stereoscopic visualization improves performance on bench models using the da Vinci robotic system. Methods: Eleven surgeons carried out a series of four tasks. Positional data streamed from the da Vinci system was analyzed by means of a previously validated custom-designed software-package. An independent blinded observer scored errors. Statistical analysis included the Wilcoxon signed rank test. A p < 0.05 was deemed significant. Results: We found significant improvements in all tasks and for all parameters (p < 0.05). In addition, a significantly lower number of errors was scored using the stereoscopic mode as compared to the standard two-dimensional image (p < 0.001). Conclusion: Robotic-assisted performance on bench models is more efficient and accurate using stereoscopic visualization.
Literatur
1.
Zurück zum Zitat Datta, V, Mackay, S, Mandalia, M, Darzi, A 2001The use of electromagnetic motion tracking analysis to objectively measure open surgical skill in the laboratory-based model.J Am Coll Surg193479485CrossRefPubMed Datta, V, Mackay, S, Mandalia, M, Darzi, A 2001The use of electromagnetic motion tracking analysis to objectively measure open surgical skill in the laboratory-based model.J Am Coll Surg193479485CrossRefPubMed
2.
Zurück zum Zitat Datta, V, Chang, A, Mackay, S, Darzi, A 2002The relationship between motion analysis and surgical technical assessment.Am J Surg1847073CrossRefPubMed Datta, V, Chang, A, Mackay, S, Darzi, A 2002The relationship between motion analysis and surgical technical assessment.Am J Surg1847073CrossRefPubMed
3.
Zurück zum Zitat Chan, A, Chung, S, Yim, A, Lau, J, Ng, E, Li, A 1997Comparison of two-dimensional vs three-dimensional camera systems in laparoscopic surgery.Surg Endosc11438440 Chan, A, Chung, S, Yim, A, Lau, J, Ng, E, Li, A 1997Comparison of two-dimensional vs three-dimensional camera systems in laparoscopic surgery.Surg Endosc11438440
4.
Zurück zum Zitat Cheah, WK, Lenzi, JE, So, J, Dong, F, Kum, CK, Goh, P 2001Evaluation of a head-mounted display (HMD) in the performance of a simulated laparoscopic task.Surg Endosc15990991PubMed Cheah, WK, Lenzi, JE, So, J, Dong, F, Kum, CK, Goh, P 2001Evaluation of a head-mounted display (HMD) in the performance of a simulated laparoscopic task.Surg Endosc15990991PubMed
5.
Zurück zum Zitat Hanna, GB, Cuschieri, A 2000Influence of two-dimensional and three-dimensional imaging on endoscopic bowel suturing.World J Surg24444449PubMed Hanna, GB, Cuschieri, A 2000Influence of two-dimensional and three-dimensional imaging on endoscopic bowel suturing.World J Surg24444449PubMed
6.
Zurück zum Zitat Hanna, GB, Shimi, SM, Cuschieri, A 1998Randomised study of influence of two-dimensional versus three-dimensional imaging on performance of laparoscopic cholecystectomy.Lancet351248251CrossRefPubMed Hanna, GB, Shimi, SM, Cuschieri, A 1998Randomised study of influence of two-dimensional versus three-dimensional imaging on performance of laparoscopic cholecystectomy.Lancet351248251CrossRefPubMed
7.
Zurück zum Zitat Hernandez, JD, Bann, SD, Munz, Y, Moorthy, K, Datta, V, Martin, S, Dosis, A, Bello, F, Darzi, A, Rockall, T 2002The learning curve of a simulated surgical task using the da Vinci telemanipulator system.Br J Surg891718CrossRef Hernandez, JD, Bann, SD, Munz, Y, Moorthy, K, Datta, V, Martin, S, Dosis, A, Bello, F, Darzi, A, Rockall, T 2002The learning curve of a simulated surgical task using the da Vinci telemanipulator system.Br J Surg891718CrossRef
8.
Zurück zum Zitat Hofmeister, J, Frank, TG, Cuschieri, A, Wade, NJ 2001Perceptual aspects of two-dimensional and stereoscopic display techniques in endoscopic surgery: review and current problems.Semin Laparosc Surg81224CrossRefPubMed Hofmeister, J, Frank, TG, Cuschieri, A, Wade, NJ 2001Perceptual aspects of two-dimensional and stereoscopic display techniques in endoscopic surgery: review and current problems.Semin Laparosc Surg81224CrossRefPubMed
9.
Zurück zum Zitat Johns, DB, Brewer, JD, Soper, NJ 1996The influence of three-dimensional video systems on laparoscopic task performance.Surg Laparosc Endosc6191197CrossRefPubMed Johns, DB, Brewer, JD, Soper, NJ 1996The influence of three-dimensional video systems on laparoscopic task performance.Surg Laparosc Endosc6191197CrossRefPubMed
10.
Zurück zum Zitat McDougall, EM, Soble, JJ, Wolf, JS, Nakada, SY, Elashry, OM, Clayman, RVAD 1996Comparison of three-dimensional and two-dimensional laparoscopic video systems.J Endourol10371374PubMed McDougall, EM, Soble, JJ, Wolf, JS, Nakada, SY, Elashry, OM, Clayman, RVAD 1996Comparison of three-dimensional and two-dimensional laparoscopic video systems.J Endourol10371374PubMed
11.
Zurück zum Zitat Mueller, MD, Camartin, C, Dreher, E, Hanggi, W 1999Three-dimensional laparoscopy: gadget or progress? A randomized trial on the efficacy of three-dimensional laparoscopy.Surg Endosc13469472 Mueller, MD, Camartin, C, Dreher, E, Hanggi, W 1999Three-dimensional laparoscopy: gadget or progress? A randomized trial on the efficacy of three-dimensional laparoscopy.Surg Endosc13469472
12.
Zurück zum Zitat Prasad, SM, Maniar, HS, Soper, NJ, Damiano Jr, RJ, Klingensmith, ME 2002The effects of robotic assistance on learning curves for basic laparoscopic skills.Am J Surg183702707CrossRefPubMed Prasad, SM, Maniar, HS, Soper, NJ, Damiano Jr, RJ, Klingensmith, ME 2002The effects of robotic assistance on learning curves for basic laparoscopic skills.Am J Surg183702707CrossRefPubMed
13.
Zurück zum Zitat Peli, F 1998The visual effects of head-mounted display (HMD) are not distinguishable from those of desk-top computer display.Vision Res3820532066CrossRefPubMed Peli, F 1998The visual effects of head-mounted display (HMD) are not distinguishable from those of desk-top computer display.Vision Res3820532066CrossRefPubMed
14.
Zurück zum Zitat Satava, RM 19933-D vision technology applied to advanced minimally invasive surgery systems.Surg Endosc7429431PubMed Satava, RM 19933-D vision technology applied to advanced minimally invasive surgery systems.Surg Endosc7429431PubMed
15.
Zurück zum Zitat Schurr, MO, Kunert, W, Arezzo, A, Buess, G 1999The role and future of endoscopic imaging systems.Endoscopy31557562PubMed Schurr, MO, Kunert, W, Arezzo, A, Buess, G 1999The role and future of endoscopic imaging systems.Endoscopy31557562PubMed
16.
Zurück zum Zitat Taffinder, N, Smith, SGT, Huber, J, Russel, RCG, Darzi, A 1999The effect of a second-generation 3D endoscope on laparoscopic precision of novices and experienced surgeons.Surg Endosc1310871092PubMed Taffinder, N, Smith, SGT, Huber, J, Russel, RCG, Darzi, A 1999The effect of a second-generation 3D endoscope on laparoscopic precision of novices and experienced surgeons.Surg Endosc1310871092PubMed
17.
Zurück zum Zitat Tyrrell, RA, Leibowitz, HW 1990The relation of vergence effort to reports of visual fatigue following prolonged near work.Hum Factors32341357PubMed Tyrrell, RA, Leibowitz, HW 1990The relation of vergence effort to reports of visual fatigue following prolonged near work.Hum Factors32341357PubMed
18.
Zurück zum Zitat van Bergen, P, Kunert, W, Buess, GF 2000The effects of high-definition imaging on surgical task efficiency in minimally invasive surgery: an experimental comparison between three-dimensional imaging and direct vision through a stereoscopic TEM rectoscope.Surg Endosc147174CrossRefPubMed van Bergen, P, Kunert, W, Buess, GF 2000The effects of high-definition imaging on surgical task efficiency in minimally invasive surgery: an experimental comparison between three-dimensional imaging and direct vision through a stereoscopic TEM rectoscope.Surg Endosc147174CrossRefPubMed
19.
Zurück zum Zitat Wentink, M, Jakimowicz, JJ, Vos, LM, Meijer, DW, Wieringa, PA 2002Quantitative evaluation of three advanced laparoscopic technologies: a stereo endoscope, an image projection display and a TFT display.Surg Endosc1612371241CrossRefPubMed Wentink, M, Jakimowicz, JJ, Vos, LM, Meijer, DW, Wieringa, PA 2002Quantitative evaluation of three advanced laparoscopic technologies: a stereo endoscope, an image projection display and a TFT display.Surg Endosc1612371241CrossRefPubMed
Metadaten
Titel
The benfits of stereoscopic vision in robotic-assisted performance on bench models
verfasst von
Y. Munz
K. Moorthy
A. Dosis
J. D. Hernandez
S. Bann
F. Bello
S. Martin
A. Darzi
T. Rockall
Publikationsdatum
01.04.2004
Erschienen in
Surgical Endoscopy / Ausgabe 4/2004
Print ISSN: 0930-2794
Elektronische ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-003-9017-9

Weitere Artikel der Ausgabe 4/2004

Surgical Endoscopy 4/2004 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.