Skip to main content
Erschienen in: Surgical Endoscopy 10/2003

01.10.2003 | Letter to the editor

Laparoscopic surgery and ergonomics: It’s time to think of ourselves as well

verfasst von: A. Vereczkel, H. Bubb, H. Feussner

Erschienen in: Surgical Endoscopy | Ausgabe 10/2003

Einloggen, um Zugang zu erhalten

Excerpt

Laparoscopic surgery has brought many benefits to patients. The reduction of pain, the shorter recovery time and hospital stay, and the earlier restitution of normal physiological markers have been proven objectively in many well-designed clinical studies. It has also been clear from the beginning, and has been investigated thoroughly ever since that time, that minimally invasive techniques can also cause harm to patients if they are applied indiscriminately [6]. However, the fact that laparoscopic surgery can also harm laparoscopic surgeons was only recognized somewhat later, and this phenomenon is now being investigated worldwide. …
Literatur
1.
Zurück zum Zitat Berguer, R, Rab, GT, Abu-Ghaida, H, Alarcon, A, Chung, J 1997A comparison of surgeons’ posture during laparoscopic and open surgical procedures.Surg Endosc2139142CrossRef Berguer, R, Rab, GT, Abu-Ghaida, H, Alarcon, A, Chung, J 1997A comparison of surgeons’ posture during laparoscopic and open surgical procedures.Surg Endosc2139142CrossRef
2.
Zurück zum Zitat Berguer, R, Forkey, DL, Smith, WD 1999Ergonomic problems associated with laparoscopic surgery.Surg Endosc5466468 Berguer, R, Forkey, DL, Smith, WD 1999Ergonomic problems associated with laparoscopic surgery.Surg Endosc5466468
3.
Zurück zum Zitat Berguer, R, Smith, WD, Chung, YH 2001Performing laparoscopic surgery is significantly more stressful for the surgeon than open surgery.Surg Endosc1012041207 Berguer, R, Smith, WD, Chung, YH 2001Performing laparoscopic surgery is significantly more stressful for the surgeon than open surgery.Surg Endosc1012041207
4.
Zurück zum Zitat Berguer, R, Smith, WD, Davis, S 2002An ergonomic study of the optimum operating table height for laparoscopic surgery.Surg Endosc3416421CrossRef Berguer, R, Smith, WD, Davis, S 2002An ergonomic study of the optimum operating table height for laparoscopic surgery.Surg Endosc3416421CrossRef
5.
Zurück zum Zitat Crothers, IR, Gallagher, AG, McClure, N, James, DT, McGuigan, J 1999Experienced laparoscopic surgeons are automated to the “fulcrum effect”: an ergonomic demonstration.Endoscopy5365369CrossRef Crothers, IR, Gallagher, AG, McClure, N, James, DT, McGuigan, J 1999Experienced laparoscopic surgeons are automated to the “fulcrum effect”: an ergonomic demonstration.Endoscopy5365369CrossRef
6.
Zurück zum Zitat Cuschieri, A 1995Whither minimal access surgery: tribulations and expectations.Am J Surg1919 Cuschieri, A 1995Whither minimal access surgery: tribulations and expectations.Am J Surg1919
7.
Zurück zum Zitat Emam, TA, Frank, TG, Hanna, GB, Cuschieri, A 2001Influence of handle design on the surgeon’s upper limb movements, muscle recruitment, and fatigue during endoscopic suturing.Surg Endosc7667672CrossRef Emam, TA, Frank, TG, Hanna, GB, Cuschieri, A 2001Influence of handle design on the surgeon’s upper limb movements, muscle recruitment, and fatigue during endoscopic suturing.Surg Endosc7667672CrossRef
8.
Zurück zum Zitat Gallagher, AG, McClure, N, McGuigan, J, Ritchie, K, Sheehy, NP 1998An ergonomic analysis of the fulcrum effect in the acquisition of endoscopic skills.Endoscopy7617620 Gallagher, AG, McClure, N, McGuigan, J, Ritchie, K, Sheehy, NP 1998An ergonomic analysis of the fulcrum effect in the acquisition of endoscopic skills.Endoscopy7617620
9.
Zurück zum Zitat Hanna, GB, Shimi, SM, Cuschieri, A 1998Taskperformance in endoscopic surgery is influenced by location of the image display.Ann Surg4481484 Hanna, GB, Shimi, SM, Cuschieri, A 1998Taskperformance in endoscopic surgery is influenced by location of the image display.Ann Surg4481484
10.
Zurück zum Zitat Herron, DM, Gagner, M, Kenyon, TL, Swanstrom, LL 2001The minimally invasive surgical suite enters the 21st century: a discussion of critical design elements.Surg Endosc4415422CrossRef Herron, DM, Gagner, M, Kenyon, TL, Swanstrom, LL 2001The minimally invasive surgical suite enters the 21st century: a discussion of critical design elements.Surg Endosc4415422CrossRef
11.
Zurück zum Zitat Horgan, LF, O’Rionda, DC, Doctor, N 1997Neoropraxia following laparoscopic procedures: an occupational injury.Min Invas Ther Allied Technol63335 Horgan, LF, O’Rionda, DC, Doctor, N 1997Neoropraxia following laparoscopic procedures: an occupational injury.Min Invas Ther Allied Technol63335
12.
Zurück zum Zitat Nguyen, NT, Ho, HS, Smith, WD, Philipps, C, Lewis, C, De Vera, RM, Berguer, R 2001An ergonomic evaluation of surgeons’ axial skeletal and upper extremity movements during laparoscopic and open surgery.Am J Surg6720724CrossRef Nguyen, NT, Ho, HS, Smith, WD, Philipps, C, Lewis, C, De Vera, RM, Berguer, R 2001An ergonomic evaluation of surgeons’ axial skeletal and upper extremity movements during laparoscopic and open surgery.Am J Surg6720724CrossRef
13.
Zurück zum Zitat Niebuhr, H, Born, O 2000Image tracking system: a new technique for safe and cost-saving laparoscopic operation.Chirurg5580584CrossRef Niebuhr, H, Born, O 2000Image tracking system: a new technique for safe and cost-saving laparoscopic operation.Chirurg5580584CrossRef
14.
Zurück zum Zitat Omote, K, Feussner, H, Ungeheuer, A, Arbter, K, Wei, GQ, Siewert, JR, Hirzinger, G 1999Self-guided robotic camera control for laparoscopic surgery compared with human camera control.Am J Surg4321324CrossRef Omote, K, Feussner, H, Ungeheuer, A, Arbter, K, Wei, GQ, Siewert, JR, Hirzinger, G 1999Self-guided robotic camera control for laparoscopic surgery compared with human camera control.Am J Surg4321324CrossRef
15.
Zurück zum Zitat Person, JG, Hodgson, AJ, Nagy, AG 2001Automated high-frequency posture sampling for ergonomic assessment of laparoscopic surgery.Surg Endosc99971003 Person, JG, Hodgson, AJ, Nagy, AG 2001Automated high-frequency posture sampling for ergonomic assessment of laparoscopic surgery.Surg Endosc99971003
16.
Zurück zum Zitat Schurr, MO, Buess, GF, Wieth, F, Saile, HJ, Botsch, M 1999Ergonomic surgeon’s chair for use during minimally invasive surgery.Surg Laparosc Endosc Percutan Tech4244247CrossRef Schurr, MO, Buess, GF, Wieth, F, Saile, HJ, Botsch, M 1999Ergonomic surgeon’s chair for use during minimally invasive surgery.Surg Laparosc Endosc Percutan Tech4244247CrossRef
17.
Zurück zum Zitat Seitz, T, Balzulat, J, Bubb, H 2000Anthropometry and measurement of posture and motion.Int J Indust Ergonom25447453CrossRef Seitz, T, Balzulat, J, Bubb, H 2000Anthropometry and measurement of posture and motion.Int J Indust Ergonom25447453CrossRef
18.
Zurück zum Zitat Van Veelen, MA, Meijer, DW 1999Ergonomics and design of laparoscopic instruments: results of a survey among laparoscopic surgeons.J Laparoendosc Adv Surg Tech A6481489 Van Veelen, MA, Meijer, DW 1999Ergonomics and design of laparoscopic instruments: results of a survey among laparoscopic surgeons.J Laparoendosc Adv Surg Tech A6481489
Metadaten
Titel
Laparoscopic surgery and ergonomics: It’s time to think of ourselves as well
verfasst von
A. Vereczkel
H. Bubb
H. Feussner
Publikationsdatum
01.10.2003
Erschienen in
Surgical Endoscopy / Ausgabe 10/2003
Print ISSN: 0930-2794
Elektronische ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-003-9020-1

Weitere Artikel der Ausgabe 10/2003

Surgical Endoscopy 10/2003 Zur Ausgabe

Letter to the editor

The author replies

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

CME: 2 Punkte

Prof. Dr. med. Gregor Antoniadis Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

CME: 2 Punkte

Dr. med. Benjamin Meyknecht, PD Dr. med. Oliver Pieske Das Webinar S2e-Leitlinie „Distale Radiusfraktur“ beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

CME: 2 Punkte

Dr. med. Mihailo Andric
Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.