Computed tomographic measurements of mesh shrinkage after laparoscopic ventral incisional hernia repair with an expanded polytetrafluoroethylene mesh

verfasst von: Ernst J. P. Schoenmaeckers, Steef B. A. van der Valk, Huib W. van den Hout, Johan F. T. J. Raymakers, Srdjan Rakic

Erschienen in: Surgical Endoscopy | Ausgabe 7/2009

Einloggen, um Zugang zu erhalten

Abstract

Background

The potential for shrinkage of intraperitoneally implanted meshes for laparoscopic repair of ventral and incisional hernia (LRVIH) remains a concern. Numerous experimental studies on this issue reported very inconsistent results. Expanded polytetrafluoroethylene (ePTFE) mesh has the unique property of being revealed by computed tomography (CT). We therefore conducted an analysis of CT findings in patients who had previously undergone LRVIH with an ePTFE mesh (DualMesh, WL Gore, Flagstaff, AZ, USA) in order to evaluate the shrinkage of implanted meshes.

Patients and methods

Of 656 LRVIH patients with DualMesh, all patients who subsequently underwent CT scanning were identified and only those with precisely known transverse diameter of implanted mesh and with CT scans made more than 3 months postoperatively were selected (n = 40). Two radiologists who were blinded to the size of the implanted mesh measured in consensus the maximal transverse diameter of the meshes by using the AquariusNET program (TeraRecon Inc., San Mateo, CA, USA). Mesh shrinkage was defined as the relative loss of transverse diameter as compared with the original transverse diameter of the mesh.

Results

The mean time from LRVIH to CT scan was 17.9 months (range 3–59 months). The mean shrinkage of the mesh was 7.5% (range 0–23.7%). For 11 patients (28%) there was no shrinkage at all. Shrinkage of 1–10% was found in 16 patients (40%), of 10–20% in 10 patients (25%), and of 20–24% in 3 patients (7.5%). No correlation was found regarding the elapsed time between LRVIH and CT, and shrinkage. There were two recurrences, one possibly related to shrinkage.

Conclusion

Our observations indicate that shrinkage of DualMesh is remarkably lower than has been reported in experimental studies (8–51%). This study is the first to address the problem of shrinkage after intraperitoneal implantation of synthetic mesh in a clinical material.
Literatur
1.
Zurück zum Zitat Garcia-Urena MA, Vega Ruiz V, Diaz Godoy A, Baez Perea JM, Marin Gomez LM, Carnero Hernandez FJ, Velasco Garcia MA (2007) Differences in polypropylene shrinkage depending on mesh position in an experimental study. Am J Surg 193:538–542PubMedCrossRef Garcia-Urena MA, Vega Ruiz V, Diaz Godoy A, Baez Perea JM, Marin Gomez LM, Carnero Hernandez FJ, Velasco Garcia MA (2007) Differences in polypropylene shrinkage depending on mesh position in an experimental study. Am J Surg 193:538–542PubMedCrossRef
2.
Zurück zum Zitat Harrell AG, Novitsky YW, Peindl RD, Cobb WS, Austin CE, Cristiano JA, Norton JH, Kercher KW, Heniford BT (2006) Prospective evaluation of adhesion formation and shrinkage of intra-abdominal prosthetics in a rabbit model. Am Surg 72:808–813 (discussion 813–814) Harrell AG, Novitsky YW, Peindl RD, Cobb WS, Austin CE, Cristiano JA, Norton JH, Kercher KW, Heniford BT (2006) Prospective evaluation of adhesion formation and shrinkage of intra-abdominal prosthetics in a rabbit model. Am Surg 72:808–813 (discussion 813–814)
3.
Zurück zum Zitat Jacob BP, Hogle NJ, Durak E, Kim T, Fowler DL (2007) Tissue ingrowth and bowel adhesion formation in an animal comparative study: polypropylene versus Proceed versus Parietex Composite. Surg Endosc 21:629–633PubMedCrossRef Jacob BP, Hogle NJ, Durak E, Kim T, Fowler DL (2007) Tissue ingrowth and bowel adhesion formation in an animal comparative study: polypropylene versus Proceed versus Parietex Composite. Surg Endosc 21:629–633PubMedCrossRef
4.
Zurück zum Zitat Burger JW, Halm JA, Wijsmuller AR, ten Raa S, Jeekel J (2006) Evaluation of new prosthetic meshes for ventral hernia repair. Surg Endosc 20:1320–1325PubMedCrossRef Burger JW, Halm JA, Wijsmuller AR, ten Raa S, Jeekel J (2006) Evaluation of new prosthetic meshes for ventral hernia repair. Surg Endosc 20:1320–1325PubMedCrossRef
5.
Zurück zum Zitat Judge TW, Parker DM, Dinsmore RC (2007) Abdominal wall hernia repair: a comparison of sepramesh and parietex composite mesh in a rabbit hernia model. J Am Coll Surg 204:276–281PubMedCrossRef Judge TW, Parker DM, Dinsmore RC (2007) Abdominal wall hernia repair: a comparison of sepramesh and parietex composite mesh in a rabbit hernia model. J Am Coll Surg 204:276–281PubMedCrossRef
6.
Zurück zum Zitat Ladurner R, Drosse I, Seitz S, Plitz W, Barbaryka G, Siebeck M, Burklein D, Kirchhoff C, Buhman S, Mutschler W, Schieker M, Mussack T (2008) Tissue attachment strength and adhesion formation of intraabdominal fixed meshes with cyanoacrylate glues. Eur J Med Res 13:185–191PubMed Ladurner R, Drosse I, Seitz S, Plitz W, Barbaryka G, Siebeck M, Burklein D, Kirchhoff C, Buhman S, Mutschler W, Schieker M, Mussack T (2008) Tissue attachment strength and adhesion formation of intraabdominal fixed meshes with cyanoacrylate glues. Eur J Med Res 13:185–191PubMed
7.
Zurück zum Zitat Bellon JM, Rodriguez M, Garcia Honduvilla N, Pascual G, Bujan J (2007) Partially absorbable meshes for hernia repair offer advantages over nonabsorbable meshes. Am J Surg 194:68–74PubMedCrossRef Bellon JM, Rodriguez M, Garcia Honduvilla N, Pascual G, Bujan J (2007) Partially absorbable meshes for hernia repair offer advantages over nonabsorbable meshes. Am J Surg 194:68–74PubMedCrossRef
8.
Zurück zum Zitat Novitsky YW, Harrell AG, Cristiano JA, Paton BL, Norton HJ, Peindl RD, Kercher KW, Heniford BT (2007) Comparative evaluation of adhesion formation, strength of ingrowth, and textile properties of prosthetic meshes after long-term intra-abdominal implantation in a rabbit. J Surg Res 140:6–11PubMedCrossRef Novitsky YW, Harrell AG, Cristiano JA, Paton BL, Norton HJ, Peindl RD, Kercher KW, Heniford BT (2007) Comparative evaluation of adhesion formation, strength of ingrowth, and textile properties of prosthetic meshes after long-term intra-abdominal implantation in a rabbit. J Surg Res 140:6–11PubMedCrossRef
9.
Zurück zum Zitat Schug Pass C, Tamme C, Tannapfel A, Kockerling F (2006) A lightweight polypropylene mesh (TiMesh) for laparoscopic intraperitoneal repair of abdominal wall hernias: comparison of biocompatibility with the DualMesh in an experimental study using the porcine model. Surg Endosc 20:402–409PubMedCrossRef Schug Pass C, Tamme C, Tannapfel A, Kockerling F (2006) A lightweight polypropylene mesh (TiMesh) for laparoscopic intraperitoneal repair of abdominal wall hernias: comparison of biocompatibility with the DualMesh in an experimental study using the porcine model. Surg Endosc 20:402–409PubMedCrossRef
10.
Zurück zum Zitat McGinty JJ, Hogle NJ, McCarthy H, Fowler DL (2005) A comparative study of adhesion formation and abdominal wall ingrowth after laparoscopic ventral hernia repair in a porcine model using multiple types of mesh. Surg Endosc 19:786–790PubMedCrossRef McGinty JJ, Hogle NJ, McCarthy H, Fowler DL (2005) A comparative study of adhesion formation and abdominal wall ingrowth after laparoscopic ventral hernia repair in a porcine model using multiple types of mesh. Surg Endosc 19:786–790PubMedCrossRef
11.
Zurück zum Zitat Johnson EK, Hoyt CH, Dinsmore RC (2004) Abdominal wall hernia repair: a long-term comparison of Sepramesh and Dualmesh in a rabbit hernia model. Am Surg 70:657–661PubMed Johnson EK, Hoyt CH, Dinsmore RC (2004) Abdominal wall hernia repair: a long-term comparison of Sepramesh and Dualmesh in a rabbit hernia model. Am Surg 70:657–661PubMed
12.
Zurück zum Zitat Schug Pass C, Tamme C, Sommerer F, Tannapfel A, Lippert H, Kockerling F (2008) A lightweight, partially absorbable mesh (Ultrapro) for endoscopic hernia repair: experimental biocompatibility results obtained with a porcine model. Surg Endosc 22:1100–1106PubMedCrossRef Schug Pass C, Tamme C, Sommerer F, Tannapfel A, Lippert H, Kockerling F (2008) A lightweight, partially absorbable mesh (Ultrapro) for endoscopic hernia repair: experimental biocompatibility results obtained with a porcine model. Surg Endosc 22:1100–1106PubMedCrossRef
Metadaten
Titel
Computed tomographic measurements of mesh shrinkage after laparoscopic ventral incisional hernia repair with an expanded polytetrafluoroethylene mesh
verfasst von
Ernst J. P. Schoenmaeckers
Steef B. A. van der Valk
Huib W. van den Hout
Johan F. T. J. Raymakers
Srdjan Rakic
Publikationsdatum
01.07.2009
Verlag
Springer-Verlag
Erschienen in
Surgical Endoscopy / Ausgabe 7/2009
Print ISSN: 0930-2794
Elektronische ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-009-0500-9

Weitere Artikel der Ausgabe 7/2009

Surgical Endoscopy 7/2009 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.