Excerpt
We have described a laparoscopic technique for encircling the hepatoduodenal ligament using an Endo Retract Maxi as a tourniquet for complete interruption of blood inflow to the liver [
1]. Belli et al. [
2] stressed that this technique is not new because several years ago they started to encircle the hepatoduodenal ligament with vessel tape using an Endo Retract Maxi. Indeed, they described the same technique for performing a laparoscopic Pringle’s maneuver [
3]. However, for several years, we also had used an Endo Retract Maxi to encircle not only the hepatoduodenal ligament but also the Glissonean pedicles [
4]. …