Skip to main content
Erschienen in: Surgical Endoscopy 4/2014

01.04.2014

Objective analysis of surgeons’ ergonomy during laparoendoscopic single-site surgery through the use of surface electromyography and a motion capture data glove

verfasst von: F. J. Pérez-Duarte, M. Lucas-Hernández, A. Matos-Azevedo, J. A. Sánchez-Margallo, I. Díaz-Güemes, F. M. Sánchez-Margallo

Erschienen in: Surgical Endoscopy | Ausgabe 4/2014

Einloggen, um Zugang zu erhalten

Abstract

Background

Adding to the ergonomic inconveniences already presented by traditional laparoscopy (LAP), laparoendoscopic single-site (LESS) surgery has been found to entail other more specific problems, including greater reduction in movement freedom, in-line vision with loss of triangulation, and greater proximity of instruments. The objective of this study was to evaluate surgeons’ ergonomy during LESS surgery, through the study of muscular activity, wrist angle, and hand movements, and compare it with conventional laparoscopy.

Methods

The study group was composed by 14 experienced laparoscopic surgeons, all right-handed. Each one performed dissection tasks on a physical simulator through LAP and LESS approaches. For LAP, straight laparoscopic scissors and dissector were used, whilst for LESS articulating tip scissors and dissector were chosen. During both tasks, muscular activity of biceps brachii, triceps brachii, forearm flexors and extensors, and trapezius muscles was registered through surface electromyography. Simultaneously right-hand movements and wrist angles were obtained through a motion capture data glove (CyberGlove®), which allowed for the use of a modified RULA test applied to the recorded angles with subsequent establishment of risk levels for the wrist joint.

Results

Muscular activity for trapezius (LAP 6.94 ± 4.12 vs. LESS 11.32 ± 4.68; p ≤ 0.05) and forearm extensor muscles (LAP 9.2 ± 2.45 vs. LESS 37.07 ≤ 16.05; p ≤ 0.001) was significantly lower in conventional laparoscopy compared with LESS approach. No statistical significance was obtained between the different sensors, except in 3 of the 11 analyzed CyberGlove® sensors. The modified RULA test showed a score of 3 for laparoscopy (unacceptable), whereas for LESS a score of 2 was obtained (acceptable), with statistically significant differences between them (p ≤ 0.05).

Conclusions

The LESS approach entails greater level of muscular activity in the trapezius and forearm extensor muscles, but we have found evidences of a better wrist position during LESS compared with traditional laparoscopy.
Literatur
1.
Zurück zum Zitat Raman JD, Bagrodia A, Cadeddu JA (2009) Single-incision, umbilical laparoscopic versus conventional laparoscopic nephrectomy: a comparison of perioperative outcomes and short-term measures of convalescence. Eur Urol 55:1198–1204CrossRefPubMed Raman JD, Bagrodia A, Cadeddu JA (2009) Single-incision, umbilical laparoscopic versus conventional laparoscopic nephrectomy: a comparison of perioperative outcomes and short-term measures of convalescence. Eur Urol 55:1198–1204CrossRefPubMed
2.
Zurück zum Zitat Ponsky LE, Cherullo EE, Sawyer M, Hartke D (2008) Single access site laparoscopic radical nephrectomy: initial clinical experience. J Endourol 22:663–666CrossRefPubMed Ponsky LE, Cherullo EE, Sawyer M, Hartke D (2008) Single access site laparoscopic radical nephrectomy: initial clinical experience. J Endourol 22:663–666CrossRefPubMed
3.
Zurück zum Zitat Kaouk JH, Haber GP, Goel RK, Desai MM, Aron M, Rackley RR, Moore C, Gill IS (2008) Single-port laparoscopic surgery in urology: initial experience. Urology 71:3–6CrossRefPubMed Kaouk JH, Haber GP, Goel RK, Desai MM, Aron M, Rackley RR, Moore C, Gill IS (2008) Single-port laparoscopic surgery in urology: initial experience. Urology 71:3–6CrossRefPubMed
4.
Zurück zum Zitat Uematsu D, Akiyama G, Narita M, Magishi A (2011) Single-access laparoscopic low anterior resection with vertical suspension of the rectum. Dis Colon Rectum 54:632–637CrossRefPubMed Uematsu D, Akiyama G, Narita M, Magishi A (2011) Single-access laparoscopic low anterior resection with vertical suspension of the rectum. Dis Colon Rectum 54:632–637CrossRefPubMed
5.
Zurück zum Zitat Emami CN, Garrett D, Anselmo D, Nguyen NX (2011) Pediatric single incision laparoscopic cholecystectomy: lessons learned in the first 25 cases. Pediatr Surg Int 27:743–746CrossRefPubMed Emami CN, Garrett D, Anselmo D, Nguyen NX (2011) Pediatric single incision laparoscopic cholecystectomy: lessons learned in the first 25 cases. Pediatr Surg Int 27:743–746CrossRefPubMed
6.
Zurück zum Zitat Park HS, Kim TJ, Song T, Kim MK, Lee YY, Choi CH, Lee JW, Kim BG, Bae DS (2011) Single-port access (SPA) laparoscopic surgery in gynecology: a surgeon’s experience with an initial 200 cases. Eur J Obstet Gynecol Reprod Biol 154:81–84CrossRefPubMed Park HS, Kim TJ, Song T, Kim MK, Lee YY, Choi CH, Lee JW, Kim BG, Bae DS (2011) Single-port access (SPA) laparoscopic surgery in gynecology: a surgeon’s experience with an initial 200 cases. Eur J Obstet Gynecol Reprod Biol 154:81–84CrossRefPubMed
7.
Zurück zum Zitat Gaujoux S, Kingham TP, Jarnagin WR, D’Angelica MI, Allen PJ, Fong Y (2011) Single-incision laparoscopic liver resection. Surg Endosc 25:1489–1494CrossRefPubMed Gaujoux S, Kingham TP, Jarnagin WR, D’Angelica MI, Allen PJ, Fong Y (2011) Single-incision laparoscopic liver resection. Surg Endosc 25:1489–1494CrossRefPubMed
9.
Zurück zum Zitat Warren D, Smith D, Denise L, Forkey MS, Berguer R (1998) The virtual instrumentation (VI) laboratory facilitates customized on-site ergonomic analysis of minimally invasive surgery. Med Meets Virtual Real 50:240–245 Warren D, Smith D, Denise L, Forkey MS, Berguer R (1998) The virtual instrumentation (VI) laboratory facilitates customized on-site ergonomic analysis of minimally invasive surgery. Med Meets Virtual Real 50:240–245
10.
Zurück zum Zitat Berguer R, Chen J, Smith WD (2003) A comparison of the physical effort required for laparoscopic and open surgical techniques. Arch Surg 138:967–970CrossRefPubMed Berguer R, Chen J, Smith WD (2003) A comparison of the physical effort required for laparoscopic and open surgical techniques. Arch Surg 138:967–970CrossRefPubMed
11.
Zurück zum Zitat Hemal AK, Srinivas M, Charles AR (2001) Ergonomic problems associated with laparoscopy. J Endourol 15:499–503CrossRefPubMed Hemal AK, Srinivas M, Charles AR (2001) Ergonomic problems associated with laparoscopy. J Endourol 15:499–503CrossRefPubMed
12.
Zurück zum Zitat Berguer R, Forkey DL, Smith WD (1999) Ergonomic problems associated with laparoscopic surgery. Surg Endosc 13:466–468CrossRefPubMed Berguer R, Forkey DL, Smith WD (1999) Ergonomic problems associated with laparoscopic surgery. Surg Endosc 13:466–468CrossRefPubMed
13.
Zurück zum Zitat Berguer R, Rab GT, Abu-Ghaida H, Alarcon A, Chung J (1997) A comparison of surgeons’ posture during laparoscopic and open surgical procedures. Surg Endosc 11:139–142CrossRefPubMed Berguer R, Rab GT, Abu-Ghaida H, Alarcon A, Chung J (1997) A comparison of surgeons’ posture during laparoscopic and open surgical procedures. Surg Endosc 11:139–142CrossRefPubMed
14.
Zurück zum Zitat Perez-Duarte FJ, Sanchez-Margallo FM, Martin-Portugues ID, Sanchez-Hurtado MA, Lucas-Hernandez M, Sanchez-Margallo JA, Uson-Gargallo J (2013) Ergonomic analysis of muscle activity in the forearm and back muscles during laparoscopic surgery: influence of previous experience and performed task. Surg Laparosc Endosc Percutan Tech 23:203–207CrossRefPubMed Perez-Duarte FJ, Sanchez-Margallo FM, Martin-Portugues ID, Sanchez-Hurtado MA, Lucas-Hernandez M, Sanchez-Margallo JA, Uson-Gargallo J (2013) Ergonomic analysis of muscle activity in the forearm and back muscles during laparoscopic surgery: influence of previous experience and performed task. Surg Laparosc Endosc Percutan Tech 23:203–207CrossRefPubMed
15.
Zurück zum Zitat Perez-Duarte FJ, Sanchez-Margallo FM, Diaz-Guemes Martin-Portugues I, Sanchez-Hurtado MA, Lucas-Hernandez M, Uson Gargallo J (2012) Ergonomics in laparoscopic surgery and its importance in surgical training. Cir Esp 90:284–291CrossRefPubMed Perez-Duarte FJ, Sanchez-Margallo FM, Diaz-Guemes Martin-Portugues I, Sanchez-Hurtado MA, Lucas-Hernandez M, Uson Gargallo J (2012) Ergonomics in laparoscopic surgery and its importance in surgical training. Cir Esp 90:284–291CrossRefPubMed
16.
Zurück zum Zitat Morandeira-Rivas A, Millan-Casas L, Moreno-Sanz C, Herrero-Bogajo ML, Tenias-Burillo JM, Gimenez-Salillas L (2012) Ergonomics in laparoendoscopic single-site surgery: survey results. J Gastrointest Surg 16:2151–2159CrossRefPubMed Morandeira-Rivas A, Millan-Casas L, Moreno-Sanz C, Herrero-Bogajo ML, Tenias-Burillo JM, Gimenez-Salillas L (2012) Ergonomics in laparoendoscopic single-site surgery: survey results. J Gastrointest Surg 16:2151–2159CrossRefPubMed
17.
Zurück zum Zitat Autorino R, Cadeddu JA, Desai MM, Gettman M, Gill IS, Kavoussi LR, Lima E, Montorsi F, Richstone L, Stolzenburg JU, Kaouk JH (2011) Reply from Authors re: Jens J. Rassweiler. Is LESS/NOTES really more? Eur Urol 59:48–50CrossRef Autorino R, Cadeddu JA, Desai MM, Gettman M, Gill IS, Kavoussi LR, Lima E, Montorsi F, Richstone L, Stolzenburg JU, Kaouk JH (2011) Reply from Authors re: Jens J. Rassweiler. Is LESS/NOTES really more? Eur Urol 59:48–50CrossRef
18.
Zurück zum Zitat Montero PN, Acker CE, Heniford BT, Stefanidis D (2011) Single incision laparoscopic surgery (SILS) is associated with poorer performance and increased surgeon workload compared with standard laparoscopy. Am Surg 77:73–77PubMed Montero PN, Acker CE, Heniford BT, Stefanidis D (2011) Single incision laparoscopic surgery (SILS) is associated with poorer performance and increased surgeon workload compared with standard laparoscopy. Am Surg 77:73–77PubMed
19.
Zurück zum Zitat Islam A, Castellvi AO, Tesfay ST, Castellvi AD, Wright AS, Scott DJ (2011) Early surgeon impressions and technical difficulty associated with laparoendoscopic single-site surgery: a Society of American Gastrointestinal and Endoscopic Surgeons learning center study. Surg Endosc 25:2597–2603CrossRefPubMed Islam A, Castellvi AO, Tesfay ST, Castellvi AD, Wright AS, Scott DJ (2011) Early surgeon impressions and technical difficulty associated with laparoendoscopic single-site surgery: a Society of American Gastrointestinal and Endoscopic Surgeons learning center study. Surg Endosc 25:2597–2603CrossRefPubMed
20.
Zurück zum Zitat Canes D, Desai MM, Aron M, Haber GP, Goel RK, Stein RJ, Kaouk JH, Gill IS (2008) Transumbilical single-port surgery: evolution and current status. Eur Urol 54:1020–1029CrossRefPubMed Canes D, Desai MM, Aron M, Haber GP, Goel RK, Stein RJ, Kaouk JH, Gill IS (2008) Transumbilical single-port surgery: evolution and current status. Eur Urol 54:1020–1029CrossRefPubMed
21.
Zurück zum Zitat Cadeddu J, Fernandez R, Desai M, Bergs R, Tracy C, Tang SJ, Rao P, Scott D (2009) Novel magnetically guided intra-abdominal camera to facilitate laparoendoscopic single-site surgery: initial human experience. Surg Endosc 23:1894–1899CrossRefPubMed Cadeddu J, Fernandez R, Desai M, Bergs R, Tracy C, Tang SJ, Rao P, Scott D (2009) Novel magnetically guided intra-abdominal camera to facilitate laparoendoscopic single-site surgery: initial human experience. Surg Endosc 23:1894–1899CrossRefPubMed
22.
Zurück zum Zitat Kommu SS, Rane A (2009) Devices for laparoendoscopic single-site surgery in urology. Expert Rev Med Devices 6:95–103CrossRefPubMed Kommu SS, Rane A (2009) Devices for laparoendoscopic single-site surgery in urology. Expert Rev Med Devices 6:95–103CrossRefPubMed
23.
Zurück zum Zitat Autorino R, Stein RJ, Lima E, Damiano R, Khanna R, Haber GP, White MA, Kaouk JH (2010) Current status and future perspectives in laparoendoscopic single-site and natural orifice transluminal endoscopic urological surgery. Int J Urol 17:410–431CrossRefPubMed Autorino R, Stein RJ, Lima E, Damiano R, Khanna R, Haber GP, White MA, Kaouk JH (2010) Current status and future perspectives in laparoendoscopic single-site and natural orifice transluminal endoscopic urological surgery. Int J Urol 17:410–431CrossRefPubMed
24.
Zurück zum Zitat Yin G, Han WK, Faddegon S, Tan YK, Liu ZW, Olweny EO, Scott DJ, Cadeddu JA (2013) Laparoendoscopic single site (LESS) in vivo suturing using a magnetic anchoring and guidance system (MAGS) camera in a porcine model: impact on ergonomics and workload. Urology 81:80–84CrossRefPubMed Yin G, Han WK, Faddegon S, Tan YK, Liu ZW, Olweny EO, Scott DJ, Cadeddu JA (2013) Laparoendoscopic single site (LESS) in vivo suturing using a magnetic anchoring and guidance system (MAGS) camera in a porcine model: impact on ergonomics and workload. Urology 81:80–84CrossRefPubMed
25.
Zurück zum Zitat Han WK, Tan YK, Olweny EO, Yin G, Liu ZW, Faddegon S, Scott DJ, Cadeddu JA (2013) Comparison between magnetic anchoring and guidance system camera-assisted laparoendoscopic single-site surgery nephrectomy and conventional laparoendoscopic single-site surgery nephrectomy in a porcine model: focus on ergonomics and workload profiles. J Endourol 27:490–496CrossRefPubMed Han WK, Tan YK, Olweny EO, Yin G, Liu ZW, Faddegon S, Scott DJ, Cadeddu JA (2013) Comparison between magnetic anchoring and guidance system camera-assisted laparoendoscopic single-site surgery nephrectomy and conventional laparoendoscopic single-site surgery nephrectomy in a porcine model: focus on ergonomics and workload profiles. J Endourol 27:490–496CrossRefPubMed
26.
Zurück zum Zitat Yun MH, Eoh H, Cho J (2002) A two-dimensional dynamic finger modeling for the analysis of repetitive finger flexion and extension. Int J Ind Ergon 29:231–248CrossRef Yun MH, Eoh H, Cho J (2002) A two-dimensional dynamic finger modeling for the analysis of repetitive finger flexion and extension. Int J Ind Ergon 29:231–248CrossRef
27.
Zurück zum Zitat Grinyagin IV, Biryukova EV, Maier MA (2005) Kinematic and dynamic synergies of human precision-grip movements. J Neurophysiol 94:2284–2294CrossRefPubMed Grinyagin IV, Biryukova EV, Maier MA (2005) Kinematic and dynamic synergies of human precision-grip movements. J Neurophysiol 94:2284–2294CrossRefPubMed
28.
Zurück zum Zitat Wong JPYLR, Ma L (2000) Virtual 3D sculpting. J Visual Comp Animat 11:155–166CrossRef Wong JPYLR, Ma L (2000) Virtual 3D sculpting. J Visual Comp Animat 11:155–166CrossRef
29.
Zurück zum Zitat Sánchez-Margallo F, Sánchez-Margallo J, Pagador J, Moyano J, Moreno J, Usón J (2010) Ergonomic assessment of hand movements in laparoscopic surgery using the CyberGlove®. Computational Biomechanics for Medicine. Springer, New York, pp 121–128 Sánchez-Margallo F, Sánchez-Margallo J, Pagador J, Moyano J, Moreno J, Usón J (2010) Ergonomic assessment of hand movements in laparoscopic surgery using the CyberGlove®. Computational Biomechanics for Medicine. Springer, New York, pp 121–128
30.
Zurück zum Zitat Tang B, Hou S, Cuschieri SA (2012) Ergonomics of and technologies for single-port laparoscopic surgery. Minim Invasive Ther Allied Technol 21:46–54CrossRefPubMed Tang B, Hou S, Cuschieri SA (2012) Ergonomics of and technologies for single-port laparoscopic surgery. Minim Invasive Ther Allied Technol 21:46–54CrossRefPubMed
Metadaten
Titel
Objective analysis of surgeons’ ergonomy during laparoendoscopic single-site surgery through the use of surface electromyography and a motion capture data glove
verfasst von
F. J. Pérez-Duarte
M. Lucas-Hernández
A. Matos-Azevedo
J. A. Sánchez-Margallo
I. Díaz-Güemes
F. M. Sánchez-Margallo
Publikationsdatum
01.04.2014
Verlag
Springer US
Erschienen in
Surgical Endoscopy / Ausgabe 4/2014
Print ISSN: 0930-2794
Elektronische ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-013-3334-4

Weitere Artikel der Ausgabe 4/2014

Surgical Endoscopy 4/2014 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.