Skip to main content
Erschienen in: Surgical Endoscopy 5/2021

08.05.2020

Poly-4-hydroxybutyrate (Phasix™) mesh onlay in complex abdominal wall repair

verfasst von: Adam S. Levy, Jaime L. Bernstein, Ishani D. Premaratne, Christine H. Rohde, David M. Otterburn, Kerry A. Morrison, Michael Lieberman, Alfons Pomp, Jason A. Spector

Erschienen in: Surgical Endoscopy | Ausgabe 5/2021

Einloggen, um Zugang zu erhalten

Abstract

Background

Poly-4-hydroxybutyric acid (P4HB, Phasix™) is a biosynthetic polymer that degrades by hydrolysis that can be woven into a mesh for use in soft tissue reinforcement. Herein, we describe our initial experience performing complex abdominal wall repair (CAWR) utilizing component separation and P4HB mesh as onlay reinforcement.

Methods

All patients undergoing CAWR between June 2014 and May 2017 were followed prospectively for postoperative outcomes. Only those patients who underwent components separation with primary repair of the fascial edges followed by onlay of P4HB mesh were included in this study.

Results

105 patients (52 male, 53 female; mean age 59.2 years, range 22–84) met inclusion criteria. Mean BMI was 29.1 (range 16–48); 52% patients had prior attempted hernia repair, most with multiple medical comorbidities (71% of patients with ASA 3 or greater). 30% of cases were not clean at the time of repair (CDC class 2 or greater). Median follow-up was 36 months (range 9–63). Eighteen patients (17%) developed a hernia recurrence ranging from 2 to 36 months postoperatively. Five (5%) patients developed a localized superficial infection treated with antibiotics, three (2.8%) required re-operation for non-healing wounds, and six (6%) patients developed seroma.

Conclusions

These data demonstrate a relatively low rate of hernia recurrence, seroma, and other common complications of CAWR in a highly morbid patient population. Importantly, the rate of mesh infection was low and no patients required complete mesh removal, even when placed into a contaminated or infected surgical field.
Literatur
4.
Zurück zum Zitat Hodgson NCF, Malthaner RA, Østbye T (2000) The search for an ideal method of abdominal fascial closure. Ann Surg 231:436–442CrossRef Hodgson NCF, Malthaner RA, Østbye T (2000) The search for an ideal method of abdominal fascial closure. Ann Surg 231:436–442CrossRef
12.
Zurück zum Zitat Luijendijk RW, Hop WC, van den Tol MP, de Lange DC, Braaksma MM, Ijzermans JN, Boelhouwer RU, de Vries BC, Salu MK, Wereldsma JC, Bruijninckx CM, Jeekel J (2000) A comparison of suture repair with mesh repair for incisional hernia. N Engl J Med Boston 343:392–398CrossRef Luijendijk RW, Hop WC, van den Tol MP, de Lange DC, Braaksma MM, Ijzermans JN, Boelhouwer RU, de Vries BC, Salu MK, Wereldsma JC, Bruijninckx CM, Jeekel J (2000) A comparison of suture repair with mesh repair for incisional hernia. N Engl J Med Boston 343:392–398CrossRef
14.
Zurück zum Zitat Ramirez OMMD, Ruas EMD, Dellon ALMD (1990) “Components separation” method for closure of abdominal-wall defects: an anatomic and clinical study. Plast Reconstr Surg 86:519–526CrossRef Ramirez OMMD, Ruas EMD, Dellon ALMD (1990) “Components separation” method for closure of abdominal-wall defects: an anatomic and clinical study. Plast Reconstr Surg 86:519–526CrossRef
19.
Zurück zum Zitat Szczerba SR, Dumanian GA (2003) Definitive surgical treatment of infected or exposed ventral hernia mesh. Ann Surg 237:437–441PubMedPubMedCentral Szczerba SR, Dumanian GA (2003) Definitive surgical treatment of infected or exposed ventral hernia mesh. Ann Surg 237:437–441PubMedPubMedCentral
24.
Zurück zum Zitat Deeken CR, Matthews BD (2013) Characterization of the Mechanical Strength, Resorption Properties, and Histologic Characteristics of a Fully Absorbable Material (Poly-4-hydroxybutyrate—PHASIX Mesh) in a Porcine Model of Hernia Repair. In: International Scholarly Research Notices. https://www.hindawi.com/journals/isrn/2013/238067/. Accessed 11 July 2019 Deeken CR, Matthews BD (2013) Characterization of the Mechanical Strength, Resorption Properties, and Histologic Characteristics of a Fully Absorbable Material (Poly-4-hydroxybutyrate—PHASIX Mesh) in a Porcine Model of Hernia Repair. In: International Scholarly Research Notices. https://​www.​hindawi.​com/​journals/​isrn/​2013/​238067/​. Accessed 11 July 2019
29.
Zurück zum Zitat Shubinets V, Fox JP, Lanni MA, Tecce MG, Pauli EM, Hope WW, Kovach SJ, Fischer JP (2018) Incisional hernia in the United States: trends in hospital encounters and corresponding healthcare charges. Am Surg 84:118–125CrossRef Shubinets V, Fox JP, Lanni MA, Tecce MG, Pauli EM, Hope WW, Kovach SJ, Fischer JP (2018) Incisional hernia in the United States: trends in hospital encounters and corresponding healthcare charges. Am Surg 84:118–125CrossRef
41.
49.
Zurück zum Zitat Roth JS, Anthone GJ, Selzer DJ, Poulose BK, Bittner JG, Hope WW, Dunn RM, Martindale RG, Goldblatt MI, Earle DB, JohnR R, Mancini GJ, Greenberg JA, Linn JG, Parra-Davila E, Sandler BJ, Deeken CR, Voeller GR (2018) Prospective evaluation of poly-4-hydroxybutyrate mesh in CDC class I/high-risk ventral and incisional hernia repair: 18-month follow-up. Surg Endosc 32:1929–1936. https://doi.org/10.1007/s00464-017-5886-1CrossRefPubMed Roth JS, Anthone GJ, Selzer DJ, Poulose BK, Bittner JG, Hope WW, Dunn RM, Martindale RG, Goldblatt MI, Earle DB, JohnR R, Mancini GJ, Greenberg JA, Linn JG, Parra-Davila E, Sandler BJ, Deeken CR, Voeller GR (2018) Prospective evaluation of poly-4-hydroxybutyrate mesh in CDC class I/high-risk ventral and incisional hernia repair: 18-month follow-up. Surg Endosc 32:1929–1936. https://​doi.​org/​10.​1007/​s00464-017-5886-1CrossRefPubMed
52.
Zurück zum Zitat Cano-Valderrama O, Porrero JL, Quirós E, Bonachia O, Castillo MJ, Cervantes N, Marcos A, Torres AJ (2019) Is onlay polypropylene mesh repair an available option for incisional hernia repair? A retrospective cohort study. Am Surg 85:183–187CrossRef Cano-Valderrama O, Porrero JL, Quirós E, Bonachia O, Castillo MJ, Cervantes N, Marcos A, Torres AJ (2019) Is onlay polypropylene mesh repair an available option for incisional hernia repair? A retrospective cohort study. Am Surg 85:183–187CrossRef
58.
Zurück zum Zitat Hutchison CE, Rhemtulla IA, Mauch JT, Broach RB, Enriquez FA, Hernandez JA, Messa CA, Williams NN, Harbison SP, Fischer JP (2019) Cutting through the fat: a retrospective analysis of clinical outcomes, cost, and quality of life with the addition of panniculectomy to ventral hernia repair in overweight patients. Hernia 23:969–977. https://doi.org/10.1007/s10029-019-02024-5CrossRefPubMed Hutchison CE, Rhemtulla IA, Mauch JT, Broach RB, Enriquez FA, Hernandez JA, Messa CA, Williams NN, Harbison SP, Fischer JP (2019) Cutting through the fat: a retrospective analysis of clinical outcomes, cost, and quality of life with the addition of panniculectomy to ventral hernia repair in overweight patients. Hernia 23:969–977. https://​doi.​org/​10.​1007/​s10029-019-02024-5CrossRefPubMed
Metadaten
Titel
Poly-4-hydroxybutyrate (Phasix™) mesh onlay in complex abdominal wall repair
verfasst von
Adam S. Levy
Jaime L. Bernstein
Ishani D. Premaratne
Christine H. Rohde
David M. Otterburn
Kerry A. Morrison
Michael Lieberman
Alfons Pomp
Jason A. Spector
Publikationsdatum
08.05.2020
Verlag
Springer US
Erschienen in
Surgical Endoscopy / Ausgabe 5/2021
Print ISSN: 0930-2794
Elektronische ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-020-07601-9

Weitere Artikel der Ausgabe 5/2021

Surgical Endoscopy 5/2021 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.