Skip to main content
Erschienen in: Pediatric Nephrology 10/2003

01.10.2003 | Review

Measurement of hydrostatic intraperitoneal pressure: a useful tool for the improvement of dialysis dose prescription

verfasst von: M. Fischbach, J. Terzic, V. Laugel, B. Escande, Cl. Dangelser, A. Helmstetter

Erschienen in: Pediatric Nephrology | Ausgabe 10/2003

Einloggen, um Zugang zu erhalten

Abstract

The prescription of peritoneal dialysis should be individualized based on parameters of tolerance and adequacy. Determination of the intraperitoneal fill volume is essential for optimal patient care. Fill volume enhancement is a factor of exchange surface area recruitment: the wetted, contact peritoneal dialysis membrane. Nevertheless, fill volume enhancement can also lead to patient discomfort, with the potential risk of too high an intraperitoneal pressure (hernia, gastro-esophageal reflux). The perception of the individual patient is also a subjective parameter of fill volume tolerance assessment. In contrast, measurement of the hydrostatic intraperitoneal pressure (IPP, cmH2O) allows an objective approach to fill volume tolerance. From our clinical experience of more than 10 years of IPP measurements in child care, we can give a recommendation for normal values in children: less than 18 cm of water, usually between 5 and 15 cm, correlated to the intraperitoneal fill volume (naturally), but individually taking into account age, gender, "accustomization" and overall body mass index.
Literatur
1.
Zurück zum Zitat Fischbach M, Terzic J, Menouer S, Haraldsson B (2000) Optimal volume prescription for children on peritoneal dialysis. Perit Dial Int 20:603–606PubMed Fischbach M, Terzic J, Menouer S, Haraldsson B (2000) Optimal volume prescription for children on peritoneal dialysis. Perit Dial Int 20:603–606PubMed
2.
Zurück zum Zitat Durand PY (2000) Optimization of fill volumes in automated peritoneal dialysis. Perit Dial Int 20:601–602PubMed Durand PY (2000) Optimization of fill volumes in automated peritoneal dialysis. Perit Dial Int 20:601–602PubMed
3.
Zurück zum Zitat Fischbach M, Stefanidis CJ, Watson A for the European Pediatric Dialysis Working Group (2002) Guidelines by an ad hoc European committee on adequacy of the pediatric peritoneal dialysis prescription. Nephrol Dial Transplant 17:380–385CrossRefPubMed Fischbach M, Stefanidis CJ, Watson A for the European Pediatric Dialysis Working Group (2002) Guidelines by an ad hoc European committee on adequacy of the pediatric peritoneal dialysis prescription. Nephrol Dial Transplant 17:380–385CrossRefPubMed
4.
Zurück zum Zitat Durand PY, Chanliau J, Gamberoni J, Hestin D, Kessler M (1996) Measurement of hydrostatic intraperitoneal pressure: a necessary routine test. Perit Dial Int 16:S84–S87PubMed Durand PY, Chanliau J, Gamberoni J, Hestin D, Kessler M (1996) Measurement of hydrostatic intraperitoneal pressure: a necessary routine test. Perit Dial Int 16:S84–S87PubMed
5.
Zurück zum Zitat Fischbach M, Terzic J, Becmeur F, Lahlou A, Desprez P, Battouche D, Geisert J (1996) Relationship between intraperitoneal hydrostatic pressure and dialysate volume in children on PD. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 16:330–340 Fischbach M, Terzic J, Becmeur F, Lahlou A, Desprez P, Battouche D, Geisert J (1996) Relationship between intraperitoneal hydrostatic pressure and dialysate volume in children on PD. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 16:330–340
6.
Zurück zum Zitat Durand PY, Chanliau J, Gamberoni J, Hestin D, Kessler M (1992) Routine measurement of hydrostatic intraperitoneal pressure. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 8:108–112 Durand PY, Chanliau J, Gamberoni J, Hestin D, Kessler M (1992) Routine measurement of hydrostatic intraperitoneal pressure. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 8:108–112
7.
Zurück zum Zitat Fischbach M, Terzic J, Dangelser C, Schneider P, Roger ML, Geisert J (1997) Improved dialysis dose by optimizing intraperitoneal volume prescription thanks to intraperitoneal pressure measurements in children. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 13:271–273 Fischbach M, Terzic J, Dangelser C, Schneider P, Roger ML, Geisert J (1997) Improved dialysis dose by optimizing intraperitoneal volume prescription thanks to intraperitoneal pressure measurements in children. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 13:271–273
8.
Zurück zum Zitat Ventura MJ, Amato D, Correa-Rotter R, Paniagna R (2000) Relationship between fill volume, intraperitoneal pressure, body size and subjective discomfort perception in CAPD patients. Perit Dial Int 20:188–193PubMed Ventura MJ, Amato D, Correa-Rotter R, Paniagna R (2000) Relationship between fill volume, intraperitoneal pressure, body size and subjective discomfort perception in CAPD patients. Perit Dial Int 20:188–193PubMed
9.
Zurück zum Zitat Scanziani R, Dozio B, Pasi A, Sangalli L, Bonforte G, Rivera R, Surian M (2001) Optimization of dialysate flow on automated peritoneal dialysis (APD). Perit Dial Int 21 (Suppl 1) S31 (abstract) Scanziani R, Dozio B, Pasi A, Sangalli L, Bonforte G, Rivera R, Surian M (2001) Optimization of dialysate flow on automated peritoneal dialysis (APD). Perit Dial Int 21 (Suppl 1) S31 (abstract)
10.
Zurück zum Zitat Fischbach M, Terzic J, Menouer S, Provot E, Laugel V (2001) Relationship between fill volume (IPV), intraperitoneal pressure (IPP) and body mass index in children on chronic peritoneal dialysis (PD). Perit Dial Int 21 (Suppl 1) S88 (abstract); Perit Dial Int 2003 (in press) Fischbach M, Terzic J, Menouer S, Provot E, Laugel V (2001) Relationship between fill volume (IPV), intraperitoneal pressure (IPP) and body mass index in children on chronic peritoneal dialysis (PD). Perit Dial Int 21 (Suppl 1) S88 (abstract); Perit Dial Int 2003 (in press)
11.
Zurück zum Zitat Barak N, Ehrenpreis ED, Harrison JR, Sitrin MD (2002) Gastro-oesophageal reflux disease in obesity: pathophysiological and therapeutic considerations. Obes Rev 3:9–15CrossRefPubMed Barak N, Ehrenpreis ED, Harrison JR, Sitrin MD (2002) Gastro-oesophageal reflux disease in obesity: pathophysiological and therapeutic considerations. Obes Rev 3:9–15CrossRefPubMed
12.
Zurück zum Zitat Fischbach M, Terzic J, Schneider P, Roger ML (1998) Effect of posture on intraperitoneal pressure and peritoneal equilibration test in children. Pediatr Nephrol 12:311–314CrossRefPubMed Fischbach M, Terzic J, Schneider P, Roger ML (1998) Effect of posture on intraperitoneal pressure and peritoneal equilibration test in children. Pediatr Nephrol 12:311–314CrossRefPubMed
13.
Zurück zum Zitat Fischbach M, Desprez P, Donnars F, Geisert J (1994) Hydrostatic intraperitoneal pressure in children on peritoneal dialysis: practical implications. An 18-month clinical experience. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 10:294–296 Fischbach M, Desprez P, Donnars F, Geisert J (1994) Hydrostatic intraperitoneal pressure in children on peritoneal dialysis: practical implications. An 18-month clinical experience. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 10:294–296
14.
Zurück zum Zitat Fischbach M, Terzic J, Chauve S, Laugel V, Muller A, Haraldsson B (2003) In children, the peritoneal area available for exchange is influenced by the composition of the peritoneal dialysis fluid. J Am Soc Nephrol (in press) Fischbach M, Terzic J, Chauve S, Laugel V, Muller A, Haraldsson B (2003) In children, the peritoneal area available for exchange is influenced by the composition of the peritoneal dialysis fluid. J Am Soc Nephrol (in press)
15.
Zurück zum Zitat Fischbach M, Lahlou A, Becmeur F, Desprez P, Geisert J (1995) Hydrostatic intraperitoneal pressure in infants on peritoneal dialysis: interest after surgical peritoneal catheter implantation. Pediatr Nephrol 9:C44 (abstract) Fischbach M, Lahlou A, Becmeur F, Desprez P, Geisert J (1995) Hydrostatic intraperitoneal pressure in infants on peritoneal dialysis: interest after surgical peritoneal catheter implantation. Pediatr Nephrol 9:C44 (abstract)
16.
Zurück zum Zitat Durand PY, Chanliau J, Gamberoni J, Hestin D, Kessler M (1993) Intraperitoneal hydrostatic pressure and ultrafiltration volume in CAPD. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 9:46–48 Durand PY, Chanliau J, Gamberoni J, Hestin D, Kessler M (1993) Intraperitoneal hydrostatic pressure and ultrafiltration volume in CAPD. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 9:46–48
17.
Zurück zum Zitat Aranda RA, Romao Junior JE, Kakehashi E, Domingos W, Sabbaga E, Marcondes M, Abensur H (2000) Intraperitoneal pressure and hernias in children on peritoneal dialysis. Pediatr Nephrol 14:22–24PubMed Aranda RA, Romao Junior JE, Kakehashi E, Domingos W, Sabbaga E, Marcondes M, Abensur H (2000) Intraperitoneal pressure and hernias in children on peritoneal dialysis. Pediatr Nephrol 14:22–24PubMed
18.
Zurück zum Zitat Fischbach M, Terzic J, Gaugler C, Bergere C, Munch K, Hamel G, Provot E, Donnars F (1998) Impact of an increased intraperitoneal fill volume both on tolerance and on dialysis effectiveness in children In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 14:258–264 Fischbach M, Terzic J, Gaugler C, Bergere C, Munch K, Hamel G, Provot E, Donnars F (1998) Impact of an increased intraperitoneal fill volume both on tolerance and on dialysis effectiveness in children In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 14:258–264
19.
Zurück zum Zitat Keshaviah P, Emerson PF, Vonesh EF, Brandes JC (1994) Relationship between body size, fill volume and mass transfer coefficient in peritoneal dialysis. J Am Soc Nephrol 4:1870–1876 Keshaviah P, Emerson PF, Vonesh EF, Brandes JC (1994) Relationship between body size, fill volume and mass transfer coefficient in peritoneal dialysis. J Am Soc Nephrol 4:1870–1876
20.
Zurück zum Zitat Brandes JC, Packard WJ, Walters SK, Fritsche C (1995) Optimization of dialysate flow and mass transfer during automated peritoneal dialysis. Am J Kidney Dis 25:603–610PubMed Brandes JC, Packard WJ, Walters SK, Fritsche C (1995) Optimization of dialysate flow and mass transfer during automated peritoneal dialysis. Am J Kidney Dis 25:603–610PubMed
21.
Zurück zum Zitat Fischbach M, Haraldsson B (2001) Dynamic changes of total pore area available for peritoneal exchange in children. J Am Soc Nephrol 12:1524–1529PubMed Fischbach M, Haraldsson B (2001) Dynamic changes of total pore area available for peritoneal exchange in children. J Am Soc Nephrol 12:1524–1529PubMed
22.
Zurück zum Zitat Chagnac A, Herskovitz P, Yaacov O, Weinstein T, Hirsh J, Katz M, Gafter U (2002) Effect of increased dialysate volume on peritoneal surface area among peritoneal dialysis patients. J Am Soc Nephrol 13:2254–2259 Chagnac A, Herskovitz P, Yaacov O, Weinstein T, Hirsh J, Katz M, Gafter U (2002) Effect of increased dialysate volume on peritoneal surface area among peritoneal dialysis patients. J Am Soc Nephrol 13:2254–2259
23.
Zurück zum Zitat Harris KP, Keogh AM, Alderson L (2001) Peritoneal dialysis fill volume: can the patient tell the difference? Perit Dial Int 21 (Suppl 3) S144–S147 Harris KP, Keogh AM, Alderson L (2001) Peritoneal dialysis fill volume: can the patient tell the difference? Perit Dial Int 21 (Suppl 3) S144–S147
Metadaten
Titel
Measurement of hydrostatic intraperitoneal pressure: a useful tool for the improvement of dialysis dose prescription
verfasst von
M. Fischbach
J. Terzic
V. Laugel
B. Escande
Cl. Dangelser
A. Helmstetter
Publikationsdatum
01.10.2003
Verlag
Springer-Verlag
Erschienen in
Pediatric Nephrology / Ausgabe 10/2003
Print ISSN: 0931-041X
Elektronische ISSN: 1432-198X
DOI
https://doi.org/10.1007/s00467-003-1199-9

Weitere Artikel der Ausgabe 10/2003

Pediatric Nephrology 10/2003 Zur Ausgabe

Obituary

Jan Winberg

Update Pädiatrie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.