Skip to main content
Erschienen in: Journal of Gastroenterology 11/2009

01.11.2009 | Original Article—Alimentary Tract

Diagnosis of endoscopic Barrett’s esophagus by transnasal flexible spectral imaging color enhancement

verfasst von: Hiroyuki Osawa, Hironori Yamamoto, Naoshi Yamada, Mitsuyo Yoshizawa, Keijiro Sunada, Hiroto Kita, Hironari Ajibe, Kiichi Satoh, Kentaro Sugano

Erschienen in: Journal of Gastroenterology | Ausgabe 11/2009

Einloggen, um Zugang zu erhalten

Abstract

Background

The diagnosis of endoscopic Barrett’s esophagus (BE) has been under discussion for the past decade because palisade vessels may be obscured by inflammation or the location of upper end of gastric fold may be diversely changed. The flexible spectral imaging color enhancement (FICE) system can reconstruct improved spectral images decomposed from ordinary endoscopic images with free selection of three wavelengths, and can provide non-magnified images with high light intensity.

Methods

To evaluate whether the transnasal FICE system enables easier diagnosis of endoscopic BE, 72 patients with endoscopic BE were observed prospectively with a transnasal endoscope using both conventional images and FICE images. The visualization of palisade vessels and the identification of the demarcation between endoscopic BE mucosa and gastric mucosa were compared between FICE images and conventional endoscopic images, and the CIELAB color differences were calculated among palisade vessels, background BE mucosa and gastric folds.

Results

Palisade vessels could be more clearly visualized in BE mucosa with transnasal FICE than with conventional endoscopy. Demarcation between whitish BE mucosa and the upper end of the brownish gastric mucosa could be clearly identified using transnasal FICE images. Greater color differences existed with FICE images between palisade vessels and background BE mucosa as well as between BE mucosa and gastric folds than with conventional images, leading to better contrasting images.

Conclusions

The transnasal FICE system enables clear visualization of palisade vessels and provides better contrasting images of the demarcation between the BE mucosa and the gastric mucosa, and thus contributes to easier diagnosis of endoscopic BE.
Literatur
1.
Zurück zum Zitat Cameron AJ, Zinsmeister AR, Ballard DJ, Carney JA. Prevalence of columnar-lined (Barrett’s) esophagus. Comparison of population-based clinical and autopsy findings. Gastroenterology. 1990;99:918–22.PubMed Cameron AJ, Zinsmeister AR, Ballard DJ, Carney JA. Prevalence of columnar-lined (Barrett’s) esophagus. Comparison of population-based clinical and autopsy findings. Gastroenterology. 1990;99:918–22.PubMed
2.
Zurück zum Zitat Schnell TG, Sontag SJ, Chejfec G. Adenocarcinomas arising in tongues or short segments of Barrett’s esophagus. Dig Dis Sci. 1992;37:137–43.CrossRefPubMed Schnell TG, Sontag SJ, Chejfec G. Adenocarcinomas arising in tongues or short segments of Barrett’s esophagus. Dig Dis Sci. 1992;37:137–43.CrossRefPubMed
3.
Zurück zum Zitat Pera M, Cameron AJ, Trastek VF, Carpenter HA, Zinsmeister AR. Increasing incidence of adenocarcinoma of the esophagus and esophagogastric junction. Gastroenterology. 1993;104:510–3.PubMed Pera M, Cameron AJ, Trastek VF, Carpenter HA, Zinsmeister AR. Increasing incidence of adenocarcinoma of the esophagus and esophagogastric junction. Gastroenterology. 1993;104:510–3.PubMed
4.
Zurück zum Zitat Sharma P, Dent J, Armstrong D, Bergman JJ, Gossner L, Hoshihara Y, et al. The development and validation of an endoscopic grading system for Barrett’s esophagus: the Prague C & M criteria. Gastroenterology. 2006;131:1392–9.CrossRefPubMed Sharma P, Dent J, Armstrong D, Bergman JJ, Gossner L, Hoshihara Y, et al. The development and validation of an endoscopic grading system for Barrett’s esophagus: the Prague C & M criteria. Gastroenterology. 2006;131:1392–9.CrossRefPubMed
5.
Zurück zum Zitat Armstrong D. Review article: towards consistency in the endoscopic diagnosis of Barrett’s oesophagus and columnar metaplasia. Aliment Pharmacol Ther. 2004;20(Suppl 5):40–7.CrossRefPubMed Armstrong D. Review article: towards consistency in the endoscopic diagnosis of Barrett’s oesophagus and columnar metaplasia. Aliment Pharmacol Ther. 2004;20(Suppl 5):40–7.CrossRefPubMed
6.
Zurück zum Zitat Azuma N, Endo T, Arimura Y, Motoya S, Itoh F, Hinoda Y, et al. Prevalence of Barrett’s esophagus and expression of mucin antigens detected by a panel of monoclonal antibodies in Barrett’s esophagus and esophageal adenocarcinoma in Japan. J Gastroenterol. 2000;35:583–92.CrossRefPubMed Azuma N, Endo T, Arimura Y, Motoya S, Itoh F, Hinoda Y, et al. Prevalence of Barrett’s esophagus and expression of mucin antigens detected by a panel of monoclonal antibodies in Barrett’s esophagus and esophageal adenocarcinoma in Japan. J Gastroenterol. 2000;35:583–92.CrossRefPubMed
7.
Zurück zum Zitat Eda A, Osawa H, Satoh K, Yanaka I, Kihira K, Ishino Y, et al. Aberrant expression of CDX2 in Barrett’s epithelium and inflammatory esophageal mucosa. J Gastroenterol. 2003;38:14–22.CrossRefPubMed Eda A, Osawa H, Satoh K, Yanaka I, Kihira K, Ishino Y, et al. Aberrant expression of CDX2 in Barrett’s epithelium and inflammatory esophageal mucosa. J Gastroenterol. 2003;38:14–22.CrossRefPubMed
8.
Zurück zum Zitat Takubo K, Honma N, Aryal G, Sawabe M, Arai T, Tanaka Y, et al. Is there a set of histologic changes that are invariably reflux associated? Arch Pathol Lab Med. 2005;129:159–63.PubMed Takubo K, Honma N, Aryal G, Sawabe M, Arai T, Tanaka Y, et al. Is there a set of histologic changes that are invariably reflux associated? Arch Pathol Lab Med. 2005;129:159–63.PubMed
9.
Zurück zum Zitat Osawa H, Yoshizawa M, Yamamoto H, Kita H, Satoh K, Ohnishi H, et al. Optimal band imaging system can facilitate detection of changes in depressed-type early gastric cancer. Gastrointest Endosc. 2008;67:226–34.CrossRefPubMed Osawa H, Yoshizawa M, Yamamoto H, Kita H, Satoh K, Ohnishi H, et al. Optimal band imaging system can facilitate detection of changes in depressed-type early gastric cancer. Gastrointest Endosc. 2008;67:226–34.CrossRefPubMed
10.
Zurück zum Zitat Yoshizawa M, Osawa H, Yamamoto H, Kita H, Nakano H, Satoh K, et al. Diagnosis of elevated-type early gastric cancer by optimal band imaging system. Gastrointest Endosc. 2009;69:19–28.CrossRefPubMed Yoshizawa M, Osawa H, Yamamoto H, Kita H, Nakano H, Satoh K, et al. Diagnosis of elevated-type early gastric cancer by optimal band imaging system. Gastrointest Endosc. 2009;69:19–28.CrossRefPubMed
11.
Zurück zum Zitat Togashi K, Osawa H, Koinuma K, Hayashi Y, Miyata T, Sunada K, et al. A comparison of conventional endoscopy, chromoendoscopy and optimal band imaging system for the differentiation of neoplastic versus nonneoplastic colon polyps. Gastrointest Endosc. 2009;69:734–41.CrossRefPubMed Togashi K, Osawa H, Koinuma K, Hayashi Y, Miyata T, Sunada K, et al. A comparison of conventional endoscopy, chromoendoscopy and optimal band imaging system for the differentiation of neoplastic versus nonneoplastic colon polyps. Gastrointest Endosc. 2009;69:734–41.CrossRefPubMed
12.
Zurück zum Zitat Shaker R. Unsedated trans-nasal pharyngoesophagogastroduodenoscopy (T-EGD): technique. Gastrointest Endosc. 1994;40:346–8.PubMed Shaker R. Unsedated trans-nasal pharyngoesophagogastroduodenoscopy (T-EGD): technique. Gastrointest Endosc. 1994;40:346–8.PubMed
13.
Zurück zum Zitat Craig A, Hanlon J, Dent J, Schoeman M. A comparison of transnasal and transoral endoscopy with small-diameter endoscopes in unsedated patients. Gastrointest Endosc. 1999;49:292–6.CrossRefPubMed Craig A, Hanlon J, Dent J, Schoeman M. A comparison of transnasal and transoral endoscopy with small-diameter endoscopes in unsedated patients. Gastrointest Endosc. 1999;49:292–6.CrossRefPubMed
14.
Zurück zum Zitat Zaman A, Hahn M, Hapke R, Knigge K, Fennerty MB, Katon RM. A randomized trial of peroral versus transnasal unsedated endoscopy using an ultrathin videoendoscope. Gastrointest Endosc. 1999;49:279–84.CrossRefPubMed Zaman A, Hahn M, Hapke R, Knigge K, Fennerty MB, Katon RM. A randomized trial of peroral versus transnasal unsedated endoscopy using an ultrathin videoendoscope. Gastrointest Endosc. 1999;49:279–84.CrossRefPubMed
15.
Zurück zum Zitat Preiss C, Charton JP, Schumacher B, Neuhaus H. A randomized trial of unsedated transnasal small-caliber esophagogastroduodenoscopy (EGD) versus peroral small-caliber EGD versus conventional EGD. Endoscopy. 2003;35:641–6.CrossRefPubMed Preiss C, Charton JP, Schumacher B, Neuhaus H. A randomized trial of unsedated transnasal small-caliber esophagogastroduodenoscopy (EGD) versus peroral small-caliber EGD versus conventional EGD. Endoscopy. 2003;35:641–6.CrossRefPubMed
16.
Zurück zum Zitat Yagi J, Adachi K, Arima N, Tanaka S, Ose T, Azumi T, et al. A prospective randomized comparative study on the safety and tolerability of transnasal esophagogastroduodenoscopy. Endoscopy. 2005;37:1226–31.CrossRefPubMed Yagi J, Adachi K, Arima N, Tanaka S, Ose T, Azumi T, et al. A prospective randomized comparative study on the safety and tolerability of transnasal esophagogastroduodenoscopy. Endoscopy. 2005;37:1226–31.CrossRefPubMed
17.
Zurück zum Zitat Miyake Y, Sekiya T, Kubo S, Hara T. A new spectrophotometer for measuring the spectral reflectance of gastric mucous membrane. J Photogr Sci. 1989;37:134–8. Miyake Y, Sekiya T, Kubo S, Hara T. A new spectrophotometer for measuring the spectral reflectance of gastric mucous membrane. J Photogr Sci. 1989;37:134–8.
18.
Zurück zum Zitat Shiobara T, Zhou S, Haneishi H, Tsumura N, Miyake Y. Improved color reproduction of electronic endoscopes. J Imag Sci Technol. 1996;40:494–501. Shiobara T, Zhou S, Haneishi H, Tsumura N, Miyake Y. Improved color reproduction of electronic endoscopes. J Imag Sci Technol. 1996;40:494–501.
19.
Zurück zum Zitat Tsumura N, Tanaka T, Haneishi H, Miyake Y. Optimal design of mosaic color electronic endoscopes. Opt Commun. 1998;145:27–32.CrossRef Tsumura N, Tanaka T, Haneishi H, Miyake Y. Optimal design of mosaic color electronic endoscopes. Opt Commun. 1998;145:27–32.CrossRef
20.
Zurück zum Zitat Shiobara T, Haneishi H, Miyake Y. Color correction for colorimetric color reproduction in an electronic endoscope. Opt Commun. 1995;114:57–63.CrossRef Shiobara T, Haneishi H, Miyake Y. Color correction for colorimetric color reproduction in an electronic endoscope. Opt Commun. 1995;114:57–63.CrossRef
21.
Zurück zum Zitat Amano Y, Ishimura N, Furuta K, Takahashi Y, Chinuki D, Mishima Y, et al. Which landmark results in a more consistent diagnosis of Barrett’s esophagus, the gastric folds or the palisade vessels? Gastrointest Endosc. 2006;64:206–11.CrossRefPubMed Amano Y, Ishimura N, Furuta K, Takahashi Y, Chinuki D, Mishima Y, et al. Which landmark results in a more consistent diagnosis of Barrett’s esophagus, the gastric folds or the palisade vessels? Gastrointest Endosc. 2006;64:206–11.CrossRefPubMed
22.
Zurück zum Zitat Kuehni RG. Color-tolerance data and the tentative CIE 1976 L a b formula. J Opt Soc Am. 1976;66:497–500.CrossRefPubMed Kuehni RG. Color-tolerance data and the tentative CIE 1976 L a b formula. J Opt Soc Am. 1976;66:497–500.CrossRefPubMed
23.
Zurück zum Zitat Birkner B, Fritz N, Schatke W, Hasford J. A prospective randomized comparison of unsedated ultrathin versus standard esophagogastroduodenoscopy in routine outpatient gastroenterology practice: does it work better through the nose? Endoscopy. 2003;35:647–51.CrossRefPubMed Birkner B, Fritz N, Schatke W, Hasford J. A prospective randomized comparison of unsedated ultrathin versus standard esophagogastroduodenoscopy in routine outpatient gastroenterology practice: does it work better through the nose? Endoscopy. 2003;35:647–51.CrossRefPubMed
24.
Zurück zum Zitat Faulx AL, Catanzaro A, Zyzanski S, Cooper GS, Pfau PR, Isenberg G, et al. Patient tolerance and acceptance of unsedated ultrathin esophagoscopy. Gastrointest Endosc. 2002;55:620–3.CrossRefPubMed Faulx AL, Catanzaro A, Zyzanski S, Cooper GS, Pfau PR, Isenberg G, et al. Patient tolerance and acceptance of unsedated ultrathin esophagoscopy. Gastrointest Endosc. 2002;55:620–3.CrossRefPubMed
25.
Zurück zum Zitat Hongo M. Review article: Barrett’s oesophagus and carcinoma in Japan. Aliment Pharmacol Ther. 2004;8:50–4.CrossRef Hongo M. Review article: Barrett’s oesophagus and carcinoma in Japan. Aliment Pharmacol Ther. 2004;8:50–4.CrossRef
26.
Zurück zum Zitat Sambongi M, Igarashi T, OBI T, Yamaguchi M, Ohyama N, Kobayashi M, et al. Analysis of spectral reflectance using normalization methods from endoscopic spectrophy system. Opt Rev. 2002;9:238–43.CrossRef Sambongi M, Igarashi T, OBI T, Yamaguchi M, Ohyama N, Kobayashi M, et al. Analysis of spectral reflectance using normalization methods from endoscopic spectrophy system. Opt Rev. 2002;9:238–43.CrossRef
27.
Zurück zum Zitat Zonios G, Perelman LT, Backman V, Manoharan R, Fitzmaurice M, Van Dam J, et al. Diffuse reflectance spectroscopy of human adenomatous colon polyps in vivo. Appl Opt. 1999;38:6628–37.CrossRefPubMed Zonios G, Perelman LT, Backman V, Manoharan R, Fitzmaurice M, Van Dam J, et al. Diffuse reflectance spectroscopy of human adenomatous colon polyps in vivo. Appl Opt. 1999;38:6628–37.CrossRefPubMed
28.
Zurück zum Zitat Yao K, Yao T, Matsui T, Iwashita A, Oishi T. Hemoglobin content in intramucosal gastric carcinoma as a marker of histologic differentiation: a clinical application of quantitative electronic endoscopy. Gastrointest Endosc. 2000;52:241–5.CrossRefPubMed Yao K, Yao T, Matsui T, Iwashita A, Oishi T. Hemoglobin content in intramucosal gastric carcinoma as a marker of histologic differentiation: a clinical application of quantitative electronic endoscopy. Gastrointest Endosc. 2000;52:241–5.CrossRefPubMed
29.
Zurück zum Zitat Gono K, OBI T, Ohyama N, Ohyama N, Machida H, Sano Y, et al. Appearance of enhanced tissue features in narrow-band endoscopic imaging. J Biomed Opt. 2004;9:568–77.CrossRefPubMed Gono K, OBI T, Ohyama N, Ohyama N, Machida H, Sano Y, et al. Appearance of enhanced tissue features in narrow-band endoscopic imaging. J Biomed Opt. 2004;9:568–77.CrossRefPubMed
Metadaten
Titel
Diagnosis of endoscopic Barrett’s esophagus by transnasal flexible spectral imaging color enhancement
verfasst von
Hiroyuki Osawa
Hironori Yamamoto
Naoshi Yamada
Mitsuyo Yoshizawa
Keijiro Sunada
Hiroto Kita
Hironari Ajibe
Kiichi Satoh
Kentaro Sugano
Publikationsdatum
01.11.2009
Verlag
Springer Japan
Erschienen in
Journal of Gastroenterology / Ausgabe 11/2009
Print ISSN: 0944-1174
Elektronische ISSN: 1435-5922
DOI
https://doi.org/10.1007/s00535-009-0121-z

Weitere Artikel der Ausgabe 11/2009

Journal of Gastroenterology 11/2009 Zur Ausgabe

Original Article—Alimentary Tract

Sonic hedgehog relates to colorectal carcinogenesis

Original Article—Liver, Pancreas, and Biliary Tract

Decreased production of immunoglobulin M and A in autoimmune pancreatitis

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.