Skip to main content
Erschienen in: European Spine Journal 3/2005

01.04.2005 | Original Article

Biomechanical comparison of anterior cervical spine locked and unlocked plate-fixation systems

verfasst von: Wolfgang Lehmann, Daniel Briem, Michael Blauth, Ulf Schmidt

Erschienen in: European Spine Journal | Ausgabe 3/2005

Einloggen, um Zugang zu erhalten

Abstract

Three different anterior plate-fixation systems are available for the stabilisation of the cervical spine: (1) the cervical spine locking plate (CSLP), (2) dynamic plates allowing vertical migration of the fixation screws, and (3) various types of plates that are secured with either monocortical or bicortical unlocked screws. Unicortical screw purchase does not involve the risk of posterior cortex penetration and possible injuries to the spinal cord. The development of locking plates with unicortical screw-fixation and intrinsic stability of the screw–plate interface, via an angle-stabilised connection, was an attempt to increase the stability of unicortical screw-fixation systems. The aim of the study was to compare the biomechanical properties of a non-locking, anterior-plate system with 4.5 mm screw fixation and a locking anterior-plate system, in a single destabilised cervical spine-motion segment. Using fresh cadaveric cervical spine specimen C3–C7, multidirectional flexibility was measured at the C4–C5 level in an unconstrained test system, before and after destabilisation and fixation with an anterior plate with either locked or unlocked screw purchase. Direct comparison of the fixed cervical spine segments with unlocked and locked anterior-plate fixation did not demonstrate significant differences. This in vitro study documented that neither locked nor unlocked anterior-plate fixation can increase stability in all modes of testing. H-plate spondylodesis with unlocked screws seems to provide sufficient mechanical integrity in most cases of monosegmental lesions.
Literatur
1.
Zurück zum Zitat Aebi M, Zuber K, Marchesi D (1991) Treatment of cervical spine injuries with anterior plating. Indications, techniques, and results. Spine 16: S38–S45PubMed Aebi M, Zuber K, Marchesi D (1991) Treatment of cervical spine injuries with anterior plating. Indications, techniques, and results. Spine 16: S38–S45PubMed
2.
Zurück zum Zitat Banzer D, Felsenberg D (1989) Computerized tomography determination of bone mineral content in quantitative diagnosis of osteoporosis. Orthopade 18:12–17PubMed Banzer D, Felsenberg D (1989) Computerized tomography determination of bone mineral content in quantitative diagnosis of osteoporosis. Orthopade 18:12–17PubMed
3.
Zurück zum Zitat Berven S, Pedlow F (1999) A review of recent literature on the biomechanics of spinal instrumentation. Curr Opin Orthop 10:142–147 Berven S, Pedlow F (1999) A review of recent literature on the biomechanics of spinal instrumentation. Curr Opin Orthop 10:142–147
4.
Zurück zum Zitat Blauth M, Schmidt U, Dienst M, Knop C, Lobenhoffer P, Tscherne H (1996) Long-term outcome of 57 patients after ventral interbody spondylodesis of the lower cervical spine. Unfallchirurg 99:925–939CrossRefPubMed Blauth M, Schmidt U, Dienst M, Knop C, Lobenhoffer P, Tscherne H (1996) Long-term outcome of 57 patients after ventral interbody spondylodesis of the lower cervical spine. Unfallchirurg 99:925–939CrossRefPubMed
5.
Zurück zum Zitat Blauth M, Knop C, Bastian L, Lobenhoffer P (1997) New developments in surgery of the injured spine. Orthopade 26:437–449CrossRefPubMed Blauth M, Knop C, Bastian L, Lobenhoffer P (1997) New developments in surgery of the injured spine. Orthopade 26:437–449CrossRefPubMed
6.
Zurück zum Zitat Böhler J (1971) Operative Behandlung von Halswirbelsäulenverletzungen. Hefte Unfallheilkd 108:132–136PubMed Böhler J (1971) Operative Behandlung von Halswirbelsäulenverletzungen. Hefte Unfallheilkd 108:132–136PubMed
7.
Zurück zum Zitat Bohler J, Gaudernak T (1980) Anterior plate stabilization for fracture-dislocations of the lower cervical spine. J Trauma 20:203–205PubMed Bohler J, Gaudernak T (1980) Anterior plate stabilization for fracture-dislocations of the lower cervical spine. J Trauma 20:203–205PubMed
8.
Zurück zum Zitat Brown JA, Havel P, Ebraheim N, Greenblatt SH, Jackson WT (1988) Cervical stabilization by plate and bone fusion. Spine 13:236–240PubMed Brown JA, Havel P, Ebraheim N, Greenblatt SH, Jackson WT (1988) Cervical stabilization by plate and bone fusion. Spine 13:236–240PubMed
9.
Zurück zum Zitat Cabanela ME, Ebersold MJ (1988) Anterior plate stabilization for bursting teardrop fractures of the cervical spine. Spine 13:888–891PubMed Cabanela ME, Ebersold MJ (1988) Anterior plate stabilization for bursting teardrop fractures of the cervical spine. Spine 13:888–891PubMed
10.
Zurück zum Zitat Caspar W, Barbier DD, Klara PM (1989) Anterior cervical fusion and Caspar plate stabilization for cervical trauma. Neurosurgery 25:491–502PubMed Caspar W, Barbier DD, Klara PM (1989) Anterior cervical fusion and Caspar plate stabilization for cervical trauma. Neurosurgery 25:491–502PubMed
11.
Zurück zum Zitat Clausen JD, Ryken TC, Traynelis VC, Sawin PD, Dexter F, Goel VK (1996) Biomechanical evaluation of Caspar and Cervical Spine Locking Plate systems in a cadaveric model. J Neurosurg 84:1039–1045PubMed Clausen JD, Ryken TC, Traynelis VC, Sawin PD, Dexter F, Goel VK (1996) Biomechanical evaluation of Caspar and Cervical Spine Locking Plate systems in a cadaveric model. J Neurosurg 84:1039–1045PubMed
12.
Zurück zum Zitat Coe JD, Warden KE, Sutterlin CE III, McAfee PC (1989) Biomechanical evaluation of cervical spinal stabilization methods in a human cadaveric model. Spine 14:1122–1131PubMed Coe JD, Warden KE, Sutterlin CE III, McAfee PC (1989) Biomechanical evaluation of cervical spinal stabilization methods in a human cadaveric model. Spine 14:1122–1131PubMed
13.
Zurück zum Zitat Gallagher MR, Maiman DJ, Reinartz J, Pintar F, Yoganandan N (1993) Biomechanical evaluation of Caspar cervical screws: comparative stability under cyclical loading. Neurosurgery 33:1045–1050PubMed Gallagher MR, Maiman DJ, Reinartz J, Pintar F, Yoganandan N (1993) Biomechanical evaluation of Caspar cervical screws: comparative stability under cyclical loading. Neurosurgery 33:1045–1050PubMed
14.
Zurück zum Zitat Garvey TA, Eismont FJ, Roberti LJ (1992) Anterior decompression, structural bone grafting, and Caspar plate stabilization for unstable cervical spine fractures and/or dislocations. Spine 17:S431-S435PubMed Garvey TA, Eismont FJ, Roberti LJ (1992) Anterior decompression, structural bone grafting, and Caspar plate stabilization for unstable cervical spine fractures and/or dislocations. Spine 17:S431-S435PubMed
15.
Zurück zum Zitat Gassman J, Seligson D (1983) The anterior cervical plate. Spine 8:700–707PubMed Gassman J, Seligson D (1983) The anterior cervical plate. Spine 8:700–707PubMed
16.
Zurück zum Zitat Goffin J, van Loon J, Van Calenbergh F, Plets C (1995) Long-term results after anterior cervical fusion and osteosynthetic stabilization for fractures and/or dislocations of the cervical spine. J Spinal Disord 8:500–508PubMed Goffin J, van Loon J, Van Calenbergh F, Plets C (1995) Long-term results after anterior cervical fusion and osteosynthetic stabilization for fractures and/or dislocations of the cervical spine. J Spinal Disord 8:500–508PubMed
17.
Zurück zum Zitat Grubb MR, Currier BL, Shih JS, Bonin V, Grabowski JJ, Chao EY (1998) Biomechanical evaluation of anterior cervical spine stabilization. Spine 23:886–892CrossRefPubMed Grubb MR, Currier BL, Shih JS, Bonin V, Grabowski JJ, Chao EY (1998) Biomechanical evaluation of anterior cervical spine stabilization. Spine 23:886–892CrossRefPubMed
18.
Zurück zum Zitat Hoffmann R, McKellop HA, Sarmiento A, Lu B, Ebramzadeh E (1991) Three-dimensional measurement of fracture gap motion. Biomechanical study of experimental tibial fractures with anterior clasp fixator and ring fixator. Unfallchirurg 94:395–400PubMed Hoffmann R, McKellop HA, Sarmiento A, Lu B, Ebramzadeh E (1991) Three-dimensional measurement of fracture gap motion. Biomechanical study of experimental tibial fractures with anterior clasp fixator and ring fixator. Unfallchirurg 94:395–400PubMed
19.
Zurück zum Zitat Lehmann W, Blauth M, Briem D, Schmidt U (2004) Biomechanical analysis of anterior cervical spine plate fixation system with unicortical and bicortical screw purchase. Eur Spine J 13:69–75CrossRefPubMed Lehmann W, Blauth M, Briem D, Schmidt U (2004) Biomechanical analysis of anterior cervical spine plate fixation system with unicortical and bicortical screw purchase. Eur Spine J 13:69–75CrossRefPubMed
20.
Zurück zum Zitat Orozco DR, Llovet-Tapies J (1970) Osteosintesis en las fractures de raquis cervical. Revista Orthop Traumatol 14:285–288 Orozco DR, Llovet-Tapies J (1970) Osteosintesis en las fractures de raquis cervical. Revista Orthop Traumatol 14:285–288
21.
Zurück zum Zitat Panjabi MM (1988) Biomechanical evaluation of spinal fixation devices: I. A conceptual framework. Spine 13:1129–1134PubMed Panjabi MM (1988) Biomechanical evaluation of spinal fixation devices: I. A conceptual framework. Spine 13:1129–1134PubMed
22.
23.
Zurück zum Zitat Pitzen T, Wilke HJ, Caspar W, Claes L, Steudel WI (1999) Evaluation of a new monocortical screw for anterior cervical fusion and plating by a combined biomechanical and clinical study. Eur Spine J 8:382–387PubMed Pitzen T, Wilke HJ, Caspar W, Claes L, Steudel WI (1999) Evaluation of a new monocortical screw for anterior cervical fusion and plating by a combined biomechanical and clinical study. Eur Spine J 8:382–387PubMed
24.
Zurück zum Zitat Pitzen T, Barbier D, Tintinger F, Steudel WI, Strowitzki M (2002) Screw fixation to the posterior cortical shell does not influence peak torque and pullout in anterior cervical plating. Eur Spine J 11:494–499CrossRefPubMed Pitzen T, Barbier D, Tintinger F, Steudel WI, Strowitzki M (2002) Screw fixation to the posterior cortical shell does not influence peak torque and pullout in anterior cervical plating. Eur Spine J 11:494–499CrossRefPubMed
25.
Zurück zum Zitat Pitzen T, Lane C, Goertzen D, Dvorak M, Fisher C, Barbier D, Steudel WI, Oxland T (2003) Anterior cervical plate fixation: biomechanical effectiveness as a function of posterior element injury. J Neurosurg 99:84–90PubMed Pitzen T, Lane C, Goertzen D, Dvorak M, Fisher C, Barbier D, Steudel WI, Oxland T (2003) Anterior cervical plate fixation: biomechanical effectiveness as a function of posterior element injury. J Neurosurg 99:84–90PubMed
26.
Zurück zum Zitat Randle MJ, Wolf A, Levi L, Rigamonti D, Mirvis S, Robinson W, Bellis E, Greenberg J, Salcman M (1991) The use of anterior Caspar plate fixation in acute cervical spine injury. Surg Neurol 36:181–189CrossRefPubMed Randle MJ, Wolf A, Levi L, Rigamonti D, Mirvis S, Robinson W, Bellis E, Greenberg J, Salcman M (1991) The use of anterior Caspar plate fixation in acute cervical spine injury. Surg Neurol 36:181–189CrossRefPubMed
27.
Zurück zum Zitat Richter M, Wilke HJ, Kluger P, Claes L, Puhl W (1999) Biomechanical evaluation of a newly developed monocortical expansion screw for use in anterior internal fixation of the cervical spine. In vitro comparison with two established internal fixation systems. Spine 24:207–212CrossRefPubMed Richter M, Wilke HJ, Kluger P, Claes L, Puhl W (1999) Biomechanical evaluation of a newly developed monocortical expansion screw for use in anterior internal fixation of the cervical spine. In vitro comparison with two established internal fixation systems. Spine 24:207–212CrossRefPubMed
28.
Zurück zum Zitat Ripa DR, Kowall MG, Meyer PR Jr, Rusin JJ (1991) Series of 92 traumatic cervical spine injuries stabilized with anterior ASIF plate fusion technique. Spine 16: S46-S55PubMed Ripa DR, Kowall MG, Meyer PR Jr, Rusin JJ (1991) Series of 92 traumatic cervical spine injuries stabilized with anterior ASIF plate fusion technique. Spine 16: S46-S55PubMed
29.
Zurück zum Zitat Ryken TC, Goel VK, Clausen JD, Traynelis VC (1995) Assessment of unicortical and bicortical fixation in a quasistatic cadaveric model. Role of bone mineral density and screw torque. Spine 20:1861–1867PubMed Ryken TC, Goel VK, Clausen JD, Traynelis VC (1995) Assessment of unicortical and bicortical fixation in a quasistatic cadaveric model. Role of bone mineral density and screw torque. Spine 20:1861–1867PubMed
30.
Zurück zum Zitat Smith SA, Lindsey RW, Doherty BJ, Alexander J, Dickson JH (1995) An in-vitro biomechanical comparison of the Orosco and AO locking plates for anterior cervical spine fixation. J Spinal Disord 8:220–223PubMed Smith SA, Lindsey RW, Doherty BJ, Alexander J, Dickson JH (1995) An in-vitro biomechanical comparison of the Orosco and AO locking plates for anterior cervical spine fixation. J Spinal Disord 8:220–223PubMed
31.
Zurück zum Zitat Spivak JM, Chen D, Kummer FJ (1999) The effect of locking fixation screws on the stability of anterior cervical plating. Spine 24:334–338CrossRefPubMed Spivak JM, Chen D, Kummer FJ (1999) The effect of locking fixation screws on the stability of anterior cervical plating. Spine 24:334–338CrossRefPubMed
32.
Zurück zum Zitat Tscherne H, Hiebler G, Muhr G (1971) Zur operativen Behandlung von Frakturen und Luxationen der Halswirbelsäule. Hefte Unfallheilkd 142–144 Tscherne H, Hiebler G, Muhr G (1971) Zur operativen Behandlung von Frakturen und Luxationen der Halswirbelsäule. Hefte Unfallheilkd 142–144
33.
Zurück zum Zitat White AA, Panjabi MM (1990) Clinical Biomechanics of the spine. Lippincott, Philadelphia White AA, Panjabi MM (1990) Clinical Biomechanics of the spine. Lippincott, Philadelphia
34.
Zurück zum Zitat Wilke HJ, Wenger K, Claes L (1998) Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants. Eur Spine J 7:148–154PubMed Wilke HJ, Wenger K, Claes L (1998) Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants. Eur Spine J 7:148–154PubMed
Metadaten
Titel
Biomechanical comparison of anterior cervical spine locked and unlocked plate-fixation systems
verfasst von
Wolfgang Lehmann
Daniel Briem
Michael Blauth
Ulf Schmidt
Publikationsdatum
01.04.2005
Verlag
Springer-Verlag
Erschienen in
European Spine Journal / Ausgabe 3/2005
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-004-0746-9

Weitere Artikel der Ausgabe 3/2005

European Spine Journal 3/2005 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.