Skip to main content
Erschienen in: European Spine Journal 7/2008

01.07.2008 | Original Article

Percutaneous CT-guided biopsy of the spine: results of 430 biopsies

verfasst von: Eugenio Rimondi, Eric L. Staals, Costantino Errani, Giuseppe Bianchi, Roberto Casadei, Marco Alberghini, Maria Cristina Malaguti, Giuseppe Rossi, Stefano Durante, Mario Mercuri

Erschienen in: European Spine Journal | Ausgabe 7/2008

Einloggen, um Zugang zu erhalten

Abstract

Biopsies of lesions in the spine are often challenging procedures with significant risk of complications. CT-guided needle biopsies could lower these risks but uncertainties still exist about the diagnostic accuracy. Aim of this retrospective study was to evaluate the diagnostic accuracy of CT-guided needle biopsies for bone lesions of the spine. We retrieved the results of 430 core needle biopsies carried out over the past fifteen years at the authors’ institute and examined the results obtained. Of the 430 biopsies performed, in 401 cases the right diagnosis was made with the first CT-guided needle biopsy (93.3% accuracy rate). Highest accuracy rates were obtained in primary and secondary malignant lesions. Most false negative results were found in cervical lesions and in benign, pseudotumoral, inflammatory, and systemic pathologies. There were only 9 complications (5 transient paresis, 4 haematomas that resolved spontaneously) that had no influence on the treatment strategy, nor on the patient’s outcome. In conclusion we can assert that this technique is reliable and safe and should be considered the gold standard in biopsies of the spine.
Literatur
1.
Zurück zum Zitat Ayala AG, Ro JY, Fanning CV, Flores JP, Yasko AW (1995) Core needle biopsy and fine needle aspiration in the diagnosis of bone and soft tissue lesions. Hematol Oncol Clin North Am 9:633–651PubMed Ayala AG, Ro JY, Fanning CV, Flores JP, Yasko AW (1995) Core needle biopsy and fine needle aspiration in the diagnosis of bone and soft tissue lesions. Hematol Oncol Clin North Am 9:633–651PubMed
2.
Zurück zum Zitat Bickels J, Jelinek J, Shmookler B, Neff RS, Malawer MM (2001) Biopsy of muscoluloskeletal tumors. Current concepts. Cinical Orthop Relat Res 368:212–219 Bickels J, Jelinek J, Shmookler B, Neff RS, Malawer MM (2001) Biopsy of muscoluloskeletal tumors. Current concepts. Cinical Orthop Relat Res 368:212–219
3.
Zurück zum Zitat Campanacci M, Mercuri M, Gamberini G (1995) Biopsy. Chir Organi Mov 80(2):113–123PubMed Campanacci M, Mercuri M, Gamberini G (1995) Biopsy. Chir Organi Mov 80(2):113–123PubMed
4.
Zurück zum Zitat Costa MJ, Campman SC, Davis RL, Howell LP (1996) Fine needle aspiration cytology of sarcoma: retrospective review of diagnostic utility and specificity. Diagn Cytopathol 15:23–32PubMedCrossRef Costa MJ, Campman SC, Davis RL, Howell LP (1996) Fine needle aspiration cytology of sarcoma: retrospective review of diagnostic utility and specificity. Diagn Cytopathol 15:23–32PubMedCrossRef
5.
Zurück zum Zitat Dondelinger RF, Vanderschelden P, Capasso P, Trotteur G (1995) Spiral tomodensitometry applied to interventional procedures. J Belge Radiol 78:118–125PubMed Dondelinger RF, Vanderschelden P, Capasso P, Trotteur G (1995) Spiral tomodensitometry applied to interventional procedures. J Belge Radiol 78:118–125PubMed
6.
Zurück zum Zitat Hau MA, Kim JI, Kattapuram S, Hornicek FJ, Rosenberg AE, Gebhardt MC, Mankin HJ (2002) Accuracy of CT-guided biopsies in 359 patient with musculoskeletal lesions. Skeletal Radiol 31(6):349–353PubMedCrossRef Hau MA, Kim JI, Kattapuram S, Hornicek FJ, Rosenberg AE, Gebhardt MC, Mankin HJ (2002) Accuracy of CT-guided biopsies in 359 patient with musculoskeletal lesions. Skeletal Radiol 31(6):349–353PubMedCrossRef
7.
Zurück zum Zitat Issakov J, Flusser G, Kollender Y, Merimsky O, Lifschitz-Mercer B, Meller I (2003) Computed tomography-guided core needle biopsy for bone and sof tissue tumors. Isr Med Assoc J 5:28–30PubMed Issakov J, Flusser G, Kollender Y, Merimsky O, Lifschitz-Mercer B, Meller I (2003) Computed tomography-guided core needle biopsy for bone and sof tissue tumors. Isr Med Assoc J 5:28–30PubMed
8.
Zurück zum Zitat Kattapuram SV, Rosenthal DI (1990) Percutaneous needle biopsy of the spine. In: Sundarsen N, Schidek HH, Schliller AL, Rosenthal DI (eds) Tumor of the spine: diagnosis and clinical management. WB Saunders, Philadelphia, pp 45–61 Kattapuram SV, Rosenthal DI (1990) Percutaneous needle biopsy of the spine. In: Sundarsen N, Schidek HH, Schliller AL, Rosenthal DI (eds) Tumor of the spine: diagnosis and clinical management. WB Saunders, Philadelphia, pp 45–61
9.
Zurück zum Zitat Kornblum MB, Wesolowski DP, Fischgrund, Herkowitz HN (1998) Computed tomography-guided biopsy of the spine. A review of 103 patients. Spine 23(1):81–85 Kornblum MB, Wesolowski DP, Fischgrund, Herkowitz HN (1998) Computed tomography-guided biopsy of the spine. A review of 103 patients. Spine 23(1):81–85
10.
Zurück zum Zitat Layfield LF, Anders KH, Glasgow BJ, Mirra JM (1986) Fine needle aspiration of primary soft tissue lesion. Arch Pathol Lab Med 110:420–424PubMed Layfield LF, Anders KH, Glasgow BJ, Mirra JM (1986) Fine needle aspiration of primary soft tissue lesion. Arch Pathol Lab Med 110:420–424PubMed
11.
Zurück zum Zitat Lis E, Bilsky MH, Pisinski L, Boland P, Healey JH, O’Malley B, Krol G (2004) Percutaneous CT-guided biopsy of osseous lesion of the spine in patients with known or suspected malignancy. Am J Neuroradiol 25(9):1583–1588PubMed Lis E, Bilsky MH, Pisinski L, Boland P, Healey JH, O’Malley B, Krol G (2004) Percutaneous CT-guided biopsy of osseous lesion of the spine in patients with known or suspected malignancy. Am J Neuroradiol 25(9):1583–1588PubMed
12.
Zurück zum Zitat Madhavan VP, Smile SR, Chandra SS, Ratnakar C (2002) Value of core needle biopsy in the diagnosis of soft tissue tumours. Indian J Pathol Microbiol 45:165–168PubMed Madhavan VP, Smile SR, Chandra SS, Ratnakar C (2002) Value of core needle biopsy in the diagnosis of soft tissue tumours. Indian J Pathol Microbiol 45:165–168PubMed
13.
Zurück zum Zitat Mankin HJ, Lange TE, Spanier SS (1982) The hazards of biopsy in patients with malignant primary bone and soft-tissue tumors. J Bone Joint Surg 64A(8):1121–1127 Mankin HJ, Lange TE, Spanier SS (1982) The hazards of biopsy in patients with malignant primary bone and soft-tissue tumors. J Bone Joint Surg 64A(8):1121–1127
14.
Zurück zum Zitat Mankin HJ, Mankin CJ, Simon MA (1996) The hazards of biopsy, revisited. J Bone Joint Surg Am 78(5):656–663PubMed Mankin HJ, Mankin CJ, Simon MA (1996) The hazards of biopsy, revisited. J Bone Joint Surg Am 78(5):656–663PubMed
15.
Zurück zum Zitat Monti C, Rimondi E, Rollo G, Bettini N, Picci P, Marchi M (1994) Percutaneous computed tomography-guided biopsy in spinal diseases. Radiol Med 87(3):299–304 Monti C, Rimondi E, Rollo G, Bettini N, Picci P, Marchi M (1994) Percutaneous computed tomography-guided biopsy in spinal diseases. Radiol Med 87(3):299–304
16.
Zurück zum Zitat Ottolenghi CE (1969) Aspiration biopsy of the spine. Technique for the thoracic spine and results of twenty-eight biopsies in this region and over-all results of 1050 biopsies of other spinal segments. J Bone Joint Surg Am 51(8):1531–1544PubMed Ottolenghi CE (1969) Aspiration biopsy of the spine. Technique for the thoracic spine and results of twenty-eight biopsies in this region and over-all results of 1050 biopsies of other spinal segments. J Bone Joint Surg Am 51(8):1531–1544PubMed
17.
Zurück zum Zitat Puri A, Shingade V, Agarwal M, Anchan C, Juvekar S, Desai S, Jambhekar NA (2006) CT-guided percutaneous core needle biopsy in deep seated musculoskeletal lesions: a prospective study of 128 cases. Skeletal Radiol 35(3):138–143PubMedCrossRef Puri A, Shingade V, Agarwal M, Anchan C, Juvekar S, Desai S, Jambhekar NA (2006) CT-guided percutaneous core needle biopsy in deep seated musculoskeletal lesions: a prospective study of 128 cases. Skeletal Radiol 35(3):138–143PubMedCrossRef
18.
Zurück zum Zitat Skrzynski MC, Biermann JS, Montag A, Simon MA (1996) Diagnostic accuracy and charge savings of outpatient core needle biopsy compared with open biopsy of muscoloskeletal tumors. J Bone Joint Surg Am 78(5):644–649PubMed Skrzynski MC, Biermann JS, Montag A, Simon MA (1996) Diagnostic accuracy and charge savings of outpatient core needle biopsy compared with open biopsy of muscoloskeletal tumors. J Bone Joint Surg Am 78(5):644–649PubMed
19.
Zurück zum Zitat Welker JA, Henshaw RM, Jelinek J, Shmooker BM, Malawer MM (2000) The percutaneous needle biopsy is safe and recommended in the diagnosis of musculoskeletal masses: outcomes analysis of 155 patients at a sarcoma referred Center. Cancer 89:2677–2686PubMedCrossRef Welker JA, Henshaw RM, Jelinek J, Shmooker BM, Malawer MM (2000) The percutaneous needle biopsy is safe and recommended in the diagnosis of musculoskeletal masses: outcomes analysis of 155 patients at a sarcoma referred Center. Cancer 89:2677–2686PubMedCrossRef
20.
Zurück zum Zitat Yang YJ, Damron TA (2004) Comparison of needle core biopsy and fine needle aspiration for diagnostic accuracy in musculoskeletal lesions. Arch of Pathol Lab Med 128(7):759–764 Yang YJ, Damron TA (2004) Comparison of needle core biopsy and fine needle aspiration for diagnostic accuracy in musculoskeletal lesions. Arch of Pathol Lab Med 128(7):759–764
Metadaten
Titel
Percutaneous CT-guided biopsy of the spine: results of 430 biopsies
verfasst von
Eugenio Rimondi
Eric L. Staals
Costantino Errani
Giuseppe Bianchi
Roberto Casadei
Marco Alberghini
Maria Cristina Malaguti
Giuseppe Rossi
Stefano Durante
Mario Mercuri
Publikationsdatum
01.07.2008
Verlag
Springer-Verlag
Erschienen in
European Spine Journal / Ausgabe 7/2008
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-008-0678-x

Weitere Artikel der Ausgabe 7/2008

European Spine Journal 7/2008 Zur Ausgabe

Announcements

Announcements

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.