Skip to main content
Erschienen in: European Spine Journal 1/2010

01.01.2010 | Review Article

Image-guided spine surgery: state of the art and future directions

verfasst von: Thorsten Tjardes, Sven Shafizadeh, Dieter Rixen, Thomas Paffrath, Bertil Bouillon, Eva S. Steinhausen, Holger Baethis

Erschienen in: European Spine Journal | Ausgabe 1/2010

Einloggen, um Zugang zu erhalten

Abstract

Navigation technology is a widely available tool in spine surgery and has become a part of clinical routine in many centers. The issue of where and when navigation technology should be used is still an issue of debate. It is the aim of this study to give an overview on the current knowledge concerning the technical capabilities of image-guided approaches and to discuss possible future directions of research and implementation of this technique. Based on a Medline search total of 1,462 publications published until October 2008 were retrieved. The abstracts were scanned manually for relevance to the topics of navigated spine surgery in the cervical spine, the thoracic spine, the lumbar spine, as well as ventral spine surgery, radiation exposure, tumor surgery and cost-effectivity in navigated spine surgery. Papers not contributing to these subjects were deleted resulting in 276 papers that were included in the analysis. Image-guided approaches have been investigated and partially implemented into clinical routine in virtually any field of spine surgery. However, the data available is mostly limited to small clinical series, case reports or retrospective studies. Only two RCTs and one metaanalysis have been retrieved. Concerning the most popular application of image-guided approaches, pedicle screw insertion, the evidence of clinical benefit in the most critical areas, e.g. the thoracic spine, is still lacking. In many other areas of spine surgery, e.g. ventral spine surgery or tumor surgery, image-guided approaches are still in an experimental stage. The technical development of image-guided techniques has reached a high level as the accuracies that can be achieved technically meet the anatomical demands. However, there is evidence that the interaction between the surgeon (‘human factor’) and the navigation system is a source of inaccuracy. It is concluded that more effort needs to be spend to understand this interaction.
Literatur
1.
Zurück zum Zitat Acosta FL Jr, Quinones-Hinojosa A, Gadkary CA, Schmidt MH, Chin CT, Ames CP, Rosenberg WS, Weinstein P (2005) Frameless stereotactic image-guided C1–C2 transarticular screw fixation for atlantoaxial instability: review of 20 patients. J Spinal Disord Tech 18:385–391. doi:10.1097/01.bsd.0000169443.44202.67 PubMed Acosta FL Jr, Quinones-Hinojosa A, Gadkary CA, Schmidt MH, Chin CT, Ames CP, Rosenberg WS, Weinstein P (2005) Frameless stereotactic image-guided C1–C2 transarticular screw fixation for atlantoaxial instability: review of 20 patients. J Spinal Disord Tech 18:385–391. doi:10.​1097/​01.​bsd.​0000169443.​44202.​67 PubMed
2.
Zurück zum Zitat Acosta FL Jr, Thompson TL, Campbell S, Weinstein PR, Ames CP (2005) Use of intraoperative isocentric C-arm 3D fluoroscopy for sextant percutaneous pedicle screw placement: case report and review of the literature. Spine J 5:339–343. doi:10.1016/j.spinee.2004.09.012 PubMed Acosta FL Jr, Thompson TL, Campbell S, Weinstein PR, Ames CP (2005) Use of intraoperative isocentric C-arm 3D fluoroscopy for sextant percutaneous pedicle screw placement: case report and review of the literature. Spine J 5:339–343. doi:10.​1016/​j.​spinee.​2004.​09.​012 PubMed
3.
Zurück zum Zitat Arand M, Hartwig E, Hebold D, Kinzl L, Gebhard F (2001) Precision analysis of navigation-assisted implanted thoracic and lumbar pedicled screws. A prospective clinical study. Unfallchirurg 104:1076–1081. doi:10.1007/s001130170023 PubMed Arand M, Hartwig E, Hebold D, Kinzl L, Gebhard F (2001) Precision analysis of navigation-assisted implanted thoracic and lumbar pedicled screws. A prospective clinical study. Unfallchirurg 104:1076–1081. doi:10.​1007/​s001130170023 PubMed
4.
Zurück zum Zitat Arand M, Hartwig E, Kinzl L, Gebhard F (2001) Spinal navigation in cervical fractures—a preliminary clinical study on Judet-osteosynthesis of the axis. Comput Aided Surg 6:170–175PubMed Arand M, Hartwig E, Kinzl L, Gebhard F (2001) Spinal navigation in cervical fractures—a preliminary clinical study on Judet-osteosynthesis of the axis. Comput Aided Surg 6:170–175PubMed
6.
Zurück zum Zitat Arand M, Schempf M, Hebold D, Teller S, Kinzl L, Gebhard F (2003) Precision of navigation-assisted surgery of the thoracic and lumbar spine. Unfallchirurg 106:899–906PubMed Arand M, Schempf M, Hebold D, Teller S, Kinzl L, Gebhard F (2003) Precision of navigation-assisted surgery of the thoracic and lumbar spine. Unfallchirurg 106:899–906PubMed
9.
Zurück zum Zitat Austin MS, Vaccaro AR, Brislin B, Nachwalter R, Hilibrand AS, Albert TJ (2002) Image-guided spine surgery: a cadaver study comparing conventional open laminoforaminotomy and two image-guided techniques for pedicle screw placement in posterolateral fusion and nonfusion models. Spine 27:2503–2508. doi:10.1097/00007632-200211150-00015 PubMed Austin MS, Vaccaro AR, Brislin B, Nachwalter R, Hilibrand AS, Albert TJ (2002) Image-guided spine surgery: a cadaver study comparing conventional open laminoforaminotomy and two image-guided techniques for pedicle screw placement in posterolateral fusion and nonfusion models. Spine 27:2503–2508. doi:10.​1097/​00007632-200211150-00015 PubMed
10.
Zurück zum Zitat Batista AP, Buneo CA, Snyder LH, Andersen RA (1999) Reach plans in eye-centered coordinates. Science 285:257–260. doi:7643[pii] PubMed Batista AP, Buneo CA, Snyder LH, Andersen RA (1999) Reach plans in eye-centered coordinates. Science 285:257–260. doi:7643[pii] PubMed
11.
Zurück zum Zitat Battaglia TC, Tannoury T, Crowl AC, Chan DP, Anderson DG (2005) A cadaveric study comparing standard fluoroscopy with fluoroscopy-based computer navigation for screw fixation of the odontoid. J Surg Orthop Adv 14:175–180PubMed Battaglia TC, Tannoury T, Crowl AC, Chan DP, Anderson DG (2005) A cadaveric study comparing standard fluoroscopy with fluoroscopy-based computer navigation for screw fixation of the odontoid. J Surg Orthop Adv 14:175–180PubMed
12.
Zurück zum Zitat Bloch O, Holly LT, Park J, Obasi C, Kim K, Johnson JP (2001) Effect of frameless stereotaxy on the accuracy of C1–2 transarticular screw placement. J Neurosurg 95:74–79PubMed Bloch O, Holly LT, Park J, Obasi C, Kim K, Johnson JP (2001) Effect of frameless stereotaxy on the accuracy of C1–2 transarticular screw placement. J Neurosurg 95:74–79PubMed
13.
Zurück zum Zitat Bolger C, Wigfield C (2000) Image-guided surgery: applications to the cervical and thoracic spine and a review of the first 120 procedures. J Neurosurg 92:175–180PubMed Bolger C, Wigfield C (2000) Image-guided surgery: applications to the cervical and thoracic spine and a review of the first 120 procedures. J Neurosurg 92:175–180PubMed
14.
Zurück zum Zitat Borm W, Konig RW, Albrecht A, Richter HP, Kast E (2004) Percutaneous transarticular atlantoaxial screw fixation using a cannulated screw system and image guidance. Minim Invasive Neurosurg 47:111–114. doi:10.1055/s-2004-818449 PubMed Borm W, Konig RW, Albrecht A, Richter HP, Kast E (2004) Percutaneous transarticular atlantoaxial screw fixation using a cannulated screw system and image guidance. Minim Invasive Neurosurg 47:111–114. doi:10.​1055/​s-2004-818449 PubMed
15.
Zurück zum Zitat Carl AL, Khanuja HS, Gatto CA, Matsumoto M, vom Lehn J, Schenck J, Rohling K, Lorensen W, Vosburgh K (2000) In vivo pedicle screw placement: image-guided virtual vision. J Spinal Disord 13:225–229. doi:10.1097/00002517-200006000-00005 PubMed Carl AL, Khanuja HS, Gatto CA, Matsumoto M, vom Lehn J, Schenck J, Rohling K, Lorensen W, Vosburgh K (2000) In vivo pedicle screw placement: image-guided virtual vision. J Spinal Disord 13:225–229. doi:10.​1097/​00002517-200006000-00005 PubMed
16.
Zurück zum Zitat Carl AL, Khanuja HS, Sachs BL, Gatto CA, vom Lehn J, Vosburgh K, Schenck J, Lorensen W, Rohling K, Disler D (1997) In vitro simulation. Early results of stereotaxy for pedicle screw placement. Spine 22:1160–1164. doi:10.1097/00007632-199705150-00018 PubMed Carl AL, Khanuja HS, Sachs BL, Gatto CA, vom Lehn J, Vosburgh K, Schenck J, Lorensen W, Rohling K, Disler D (1997) In vitro simulation. Early results of stereotaxy for pedicle screw placement. Spine 22:1160–1164. doi:10.​1097/​00007632-199705150-00018 PubMed
18.
Zurück zum Zitat Chibbaro S, Benvenuti L, Carnesecchi S, Marsella M, Serino D, Gagliardi R (2005) The use of virtual fluoroscopy in managing acute type II odontoid fracture with anterior single-screw fixation. A safe, effective, elegant and fast form of treatment. Acta Neurochir (Wien) 147:735–739. doi:10.1007/s00701-005-0522-6 (discussion 739) Chibbaro S, Benvenuti L, Carnesecchi S, Marsella M, Serino D, Gagliardi R (2005) The use of virtual fluoroscopy in managing acute type II odontoid fracture with anterior single-screw fixation. A safe, effective, elegant and fast form of treatment. Acta Neurochir (Wien) 147:735–739. doi:10.​1007/​s00701-005-0522-6 (discussion 739)
19.
Zurück zum Zitat Citak M, Board TN, Sun Y, Look V, Krettek C, Hufner T, Kendoff D (2007) Reference marker stability in computer aided orthopedic surgery: a biomechanical study in artificial bone and cadavers. Technol Health Care 15:407–414PubMed Citak M, Board TN, Sun Y, Look V, Krettek C, Hufner T, Kendoff D (2007) Reference marker stability in computer aided orthopedic surgery: a biomechanical study in artificial bone and cadavers. Technol Health Care 15:407–414PubMed
20.
Zurück zum Zitat Cleary K, Anderson J, Brazaitis M, Devey G, DiGioia A, Freedman M, Gronemeyer D, Lathan C, Lemke H, Long D, Mun SK, Taylor R (2000) Final report of the technical requirements for image-guided spine procedures Workshop, April 17–20, 1999, Ellicott City, Maryland, USA. Comput Aided Surg 5:180–215PubMed Cleary K, Anderson J, Brazaitis M, Devey G, DiGioia A, Freedman M, Gronemeyer D, Lathan C, Lemke H, Long D, Mun SK, Taylor R (2000) Final report of the technical requirements for image-guided spine procedures Workshop, April 17–20, 1999, Ellicott City, Maryland, USA. Comput Aided Surg 5:180–215PubMed
21.
Zurück zum Zitat di Pellegrino G, Frassinetti F (2000) Direct evidence from parietal extinction of enhancement of visual attention near a visible hand. Curr Biol 10:1475–1477. doi:S0960-9822(00)00809-5[pii] PubMed di Pellegrino G, Frassinetti F (2000) Direct evidence from parietal extinction of enhancement of visual attention near a visible hand. Curr Biol 10:1475–1477. doi:S0960-9822(00)00809-5[pii] PubMed
22.
Zurück zum Zitat Ebmeier K, Giest K, Kalff R (2003) Intraoperative computerized tomography for improved accuracy of spinal navigation in pedicle screw placement of the thoracic spine. Acta Neurochir (Wien) 85:105–113 Ebmeier K, Giest K, Kalff R (2003) Intraoperative computerized tomography for improved accuracy of spinal navigation in pedicle screw placement of the thoracic spine. Acta Neurochir (Wien) 85:105–113
24.
Zurück zum Zitat Fritsch E, Duchow J, Seil R, Grunwald I, Reith W (2002) Accuracy of fluoroscopic navigation of pedicle screws. CT-based evaluation of bone screw placement. Orthopade 31:385–391. doi:10.1007/s00132-001-0280-y PubMed Fritsch E, Duchow J, Seil R, Grunwald I, Reith W (2002) Accuracy of fluoroscopic navigation of pedicle screws. CT-based evaluation of bone screw placement. Orthopade 31:385–391. doi:10.​1007/​s00132-001-0280-y PubMed
25.
26.
Zurück zum Zitat Gebhard F, Kinzl L, Hartwig E, Arand M (2003) Navigation of tumors and metastases in the area of the thoraco-lumbar spine. Unfallchirurg 106:949–955PubMed Gebhard F, Kinzl L, Hartwig E, Arand M (2003) Navigation of tumors and metastases in the area of the thoraco-lumbar spine. Unfallchirurg 106:949–955PubMed
27.
Zurück zum Zitat Gebhard F, Kraus M, Schneider E, Arand M, Kinzl L, Hebecker A, Batz L (2003) Radiation dosage in orthopedics—a comparison of computer-assisted procedures. Unfallchirurg 106:492–497. doi:10.1007/s00113-003-0606-9 PubMed Gebhard F, Kraus M, Schneider E, Arand M, Kinzl L, Hebecker A, Batz L (2003) Radiation dosage in orthopedics—a comparison of computer-assisted procedures. Unfallchirurg 106:492–497. doi:10.​1007/​s00113-003-0606-9 PubMed
28.
Zurück zum Zitat Gebhard FT, Kraus MD, Schneider E, Liener UC, Kinzl L, Arand M (2006) Does computer-assisted spine surgery reduce intraoperative radiation doses? Spine 31:2024–2027 (discussion 202829)PubMed Gebhard FT, Kraus MD, Schneider E, Liener UC, Kinzl L, Arand M (2006) Does computer-assisted spine surgery reduce intraoperative radiation doses? Spine 31:2024–2027 (discussion 202829)PubMed
29.
Zurück zum Zitat Geerling J, Gosling T, Gosling A, Ortega G, Kendoff D, Citak M, Krettek C, Hufner T (2008) Navigated pedicle screw placement: experimental comparison between CT- and 3D fluoroscopy-based techniques. Comput Aided Surg 13:157–166PubMed Geerling J, Gosling T, Gosling A, Ortega G, Kendoff D, Citak M, Krettek C, Hufner T (2008) Navigated pedicle screw placement: experimental comparison between CT- and 3D fluoroscopy-based techniques. Comput Aided Surg 13:157–166PubMed
32.
Zurück zum Zitat Graziano MS, Cooke DF, Taylor CS (2000) Coding the location of the arm by sight. Science 290:1782–1786. doi:9014[pii] PubMed Graziano MS, Cooke DF, Taylor CS (2000) Coding the location of the arm by sight. Science 290:1782–1786. doi:9014[pii] PubMed
34.
Zurück zum Zitat Grutzner PA, Beutler T, Wendl K, von Recum J, Wentzensen A, Nolte LP (2004) Intraoperative three-dimensional navigation for pedicle screw placement. Der Chirurg; Zeitschrift fur alle Gebiete der operativen Medizen 75:967–975PubMed Grutzner PA, Beutler T, Wendl K, von Recum J, Wentzensen A, Nolte LP (2004) Intraoperative three-dimensional navigation for pedicle screw placement. Der Chirurg; Zeitschrift fur alle Gebiete der operativen Medizen 75:967–975PubMed
36.
Zurück zum Zitat Holly LT, Bloch O, Johnson JP (2006) Evaluation of registration techniques for spinal image guidance. J Neurosurg 4:323–328 Holly LT, Bloch O, Johnson JP (2006) Evaluation of registration techniques for spinal image guidance. J Neurosurg 4:323–328
39.
Zurück zum Zitat Hott JS, Deshmukh VR, Klopfenstein JD, Sonntag VK, Dickman CA, Spetzler RF, Papadopoulos SM (2004) Intraoperative Iso-C C-arm navigation in craniospinal surgery: the first 60 cases. Neurosurgery 54:1131–1136. doi:10.1227/01.NEU.0000119755.71141.13 (discussion 1136–1137)PubMed Hott JS, Deshmukh VR, Klopfenstein JD, Sonntag VK, Dickman CA, Spetzler RF, Papadopoulos SM (2004) Intraoperative Iso-C C-arm navigation in craniospinal surgery: the first 60 cases. Neurosurgery 54:1131–1136. doi:10.​1227/​01.​NEU.​0000119755.​71141.​13 (discussion 1136–1137)PubMed
41.
Zurück zum Zitat Iriki A, Tanaka M, Iwamura Y (1996) Coding of modified body schema during tool use by macaque postcentral neurones. NeuroReport 7:2325–2330PubMed Iriki A, Tanaka M, Iwamura Y (1996) Coding of modified body schema during tool use by macaque postcentral neurones. NeuroReport 7:2325–2330PubMed
43.
Zurück zum Zitat Ito H, Neo M, Yoshida M, Fujibayashi S, Yoshitomi H, Nakamura T (2007) Efficacy of computer-assisted pedicle screw insertion for cervical instability in RA patients. Rheumatol Int 27:567–574. doi:10.1007/s00296-006-0256-7 PubMed Ito H, Neo M, Yoshida M, Fujibayashi S, Yoshitomi H, Nakamura T (2007) Efficacy of computer-assisted pedicle screw insertion for cervical instability in RA patients. Rheumatol Int 27:567–574. doi:10.​1007/​s00296-006-0256-7 PubMed
44.
Zurück zum Zitat Jackson SR, Newport R, Husain M, Harvey M, Hindle JV (2000) Reaching movements may reveal the distorted topography of spatial representations after neglect. Neuropsychologia 38:500–507. doi:S0028-3932(99)00083-4[pii] PubMed Jackson SR, Newport R, Husain M, Harvey M, Hindle JV (2000) Reaching movements may reveal the distorted topography of spatial representations after neglect. Neuropsychologia 38:500–507. doi:S0028-3932(99)00083-4[pii] PubMed
46.
Zurück zum Zitat Kamimura M, Ebara S, Itoh H, Tateiwa Y, Kinoshita T, Takaoka K (1999) Accurate pedicle screw insertion under the control of a computer-assisted image guiding system: laboratory test and clinical study. J Orthop Sci 4:197–206. doi:10.1007/s007760050094 PubMed Kamimura M, Ebara S, Itoh H, Tateiwa Y, Kinoshita T, Takaoka K (1999) Accurate pedicle screw insertion under the control of a computer-assisted image guiding system: laboratory test and clinical study. J Orthop Sci 4:197–206. doi:10.​1007/​s007760050094 PubMed
47.
Zurück zum Zitat Kamimura M, Ebara S, Itoh H, Tateiwa Y, Kinoshita T, Takaoka K (2000) Cervical pedicle screw insertion: assessment of safety and accuracy with computer-assisted image guidance. J Spinal Disord 13:218–224. doi:10.1097/00002517-200006000-00004 PubMed Kamimura M, Ebara S, Itoh H, Tateiwa Y, Kinoshita T, Takaoka K (2000) Cervical pedicle screw insertion: assessment of safety and accuracy with computer-assisted image guidance. J Spinal Disord 13:218–224. doi:10.​1097/​00002517-200006000-00004 PubMed
48.
Zurück zum Zitat Kelleher MO, McEvoy L, Nagaria J, Kamel M, Bolger C (2006) Image-guided transarticular atlanto-axial screw fixation. Int J Med Robot 2:154–160. doi:10.1002/rcs.92 PubMed Kelleher MO, McEvoy L, Nagaria J, Kamel M, Bolger C (2006) Image-guided transarticular atlanto-axial screw fixation. Int J Med Robot 2:154–160. doi:10.​1002/​rcs.​92 PubMed
50.
Zurück zum Zitat Kotani Y, Abumi K, Ito M, Minami A (2003) Improved accuracy of computer-assisted cervical pedicle screw insertion. J Neurosurg 99:257–263PubMed Kotani Y, Abumi K, Ito M, Minami A (2003) Improved accuracy of computer-assisted cervical pedicle screw insertion. J Neurosurg 99:257–263PubMed
51.
Zurück zum Zitat Kothe R, Matthias Strauss J, Deuretzbacher G, Hemmi T, Lorenzen M, Wiesner L (2001) Computer navigation of parapedicular screw fixation in the thoracic spine: a cadaver study. Spine 26:E496–E501. doi:10.1097/00007632-200111010-00019 PubMed Kothe R, Matthias Strauss J, Deuretzbacher G, Hemmi T, Lorenzen M, Wiesner L (2001) Computer navigation of parapedicular screw fixation in the thoracic spine: a cadaver study. Spine 26:E496–E501. doi:10.​1097/​00007632-200111010-00019 PubMed
52.
Zurück zum Zitat Ladavas E, di Pellegrino G, Farne A, Zeloni G (1998) Neuropsychological evidence of an integrated visuotactile representation of peripersonal space in humans. J Cogn Neurosci 10:581–589. doi:10.1162/089892998562988 PubMed Ladavas E, di Pellegrino G, Farne A, Zeloni G (1998) Neuropsychological evidence of an integrated visuotactile representation of peripersonal space in humans. J Cogn Neurosci 10:581–589. doi:10.​1162/​089892998562988 PubMed
53.
Zurück zum Zitat Laine T, Lund T, Ylikoski M, Lohikoski J, Schlenzka D (2000) Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J 9:235–240. doi:10.1007/s005860000146 PubMed Laine T, Lund T, Ylikoski M, Lohikoski J, Schlenzka D (2000) Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J 9:235–240. doi:10.​1007/​s005860000146 PubMed
54.
Zurück zum Zitat Lekovic GP, Potts EA, Karahalios DG, Hall G (2007) A comparison of two techniques in image-guided thoracic pedicle screw placement: a retrospective study of 37 patients and 277 pedicle screws. J Neurosurg 7:393–398 Lekovic GP, Potts EA, Karahalios DG, Hall G (2007) A comparison of two techniques in image-guided thoracic pedicle screw placement: a retrospective study of 37 patients and 277 pedicle screws. J Neurosurg 7:393–398
56.
Zurück zum Zitat Linhardt O, Perlick L, Luring C, Stern U, Plitz W, Grifka J (2005) Extracorporeal single dose and radiographic dosage in image-controlled and fluoroscopic navigated pedicle screw implantation. Z Orthop Ihre Grenzgeb 143:175–179. doi:10.1055/s-2005-836489 PubMed Linhardt O, Perlick L, Luring C, Stern U, Plitz W, Grifka J (2005) Extracorporeal single dose and radiographic dosage in image-controlled and fluoroscopic navigated pedicle screw implantation. Z Orthop Ihre Grenzgeb 143:175–179. doi:10.​1055/​s-2005-836489 PubMed
57.
Zurück zum Zitat Little JB, Taveras JM (eds) (1992) Radiology: diagnosis, imaging, intervention. JB Lippincott, Philadelphia Little JB, Taveras JM (eds) (1992) Radiology: diagnosis, imaging, intervention. JB Lippincott, Philadelphia
58.
Zurück zum Zitat Liu YJ, Tian W, Liu B, Li Q, Hu L, Li ZY, Yuan Q, Xing YG, Wang YQ, Sun YZ (2005) Accuracy of CT-based navigation of pedicle screws implantation in the cervical spine compared with X-ray fluoroscopy technique. Zhonghua Wai Ke Za Zhi 43:1328–1330 Chin J SurgPubMed Liu YJ, Tian W, Liu B, Li Q, Hu L, Li ZY, Yuan Q, Xing YG, Wang YQ, Sun YZ (2005) Accuracy of CT-based navigation of pedicle screws implantation in the cervical spine compared with X-ray fluoroscopy technique. Zhonghua Wai Ke Za Zhi 43:1328–1330 Chin J SurgPubMed
59.
Zurück zum Zitat Mac Millan M (2005) Computer-guided percutaneous interbody fixation and fusion of the L5-S1 disc: a 2-year prospective study. J spinal Disord Tech 18 Suppl:S90–95 Mac Millan M (2005) Computer-guided percutaneous interbody fixation and fusion of the L5-S1 disc: a 2-year prospective study. J spinal Disord Tech 18 Suppl:S90–95
60.
Zurück zum Zitat Mahadewa T, Mizuno J, Inoue T, Nakagawa H (2004) C7 fracture treated with a pedicle screw system under navigation guidance. Singapore Med J 45:489–493PubMed Mahadewa T, Mizuno J, Inoue T, Nakagawa H (2004) C7 fracture treated with a pedicle screw system under navigation guidance. Singapore Med J 45:489–493PubMed
61.
Zurück zum Zitat Maier B, Zheng G, Ploss C, Zhang X, Welle K, Nolte LP, Marzi I (2007) A CT-free, intra-operative planning and navigation system for minimally invasive anterior spinal surgery—an accuracy study. Comput Aided Surg 12:233–241. doi:10.1080/10929080701552894 PubMed Maier B, Zheng G, Ploss C, Zhang X, Welle K, Nolte LP, Marzi I (2007) A CT-free, intra-operative planning and navigation system for minimally invasive anterior spinal surgery—an accuracy study. Comput Aided Surg 12:233–241. doi:10.​1080/​1092908070155289​4 PubMed
62.
63.
Zurück zum Zitat McAfee PC, Cunningham B, Holsapple G, Adams K, Blumenthal S, Guyer RD, Dmietriev A, Maxwell JH, Regan JJ, Isaza J (2005) A prospective, randomized, multicenter Food and Drug Administration investigational device exemption study of lumbar total disc replacement with the CHARITE artificial disc versus lumbar fusion: part II: evaluation of radiographic outcomes and correlation of surgical technique accuracy with clinical outcomes. Spine 30:1576–1583, discussion E1388–1590PubMed McAfee PC, Cunningham B, Holsapple G, Adams K, Blumenthal S, Guyer RD, Dmietriev A, Maxwell JH, Regan JJ, Isaza J (2005) A prospective, randomized, multicenter Food and Drug Administration investigational device exemption study of lumbar total disc replacement with the CHARITE artificial disc versus lumbar fusion: part II: evaluation of radiographic outcomes and correlation of surgical technique accuracy with clinical outcomes. Spine 30:1576–1583, discussion E1388–1590PubMed
66.
Zurück zum Zitat Merloz P, Troccaz J, Vouaillat H, Vasile C, Tonetti J, Eid A, Plaweski S (2007) Fluoroscopy-based navigation system in spine surgery. Proc Inst Mech Eng 221:813–820. doi:10.1243/09544119JEIM268 Merloz P, Troccaz J, Vouaillat H, Vasile C, Tonetti J, Eid A, Plaweski S (2007) Fluoroscopy-based navigation system in spine surgery. Proc Inst Mech Eng 221:813–820. doi:10.​1243/​09544119JEIM268
67.
Zurück zum Zitat Mirza SK, Wiggins GC, Ct Kuntz, York JE, Bellabarba C, Knonodi MA, Chapman JR, Shaffrey CI (2003) Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance: a cadaver study. Spine 28:402–413. doi:10.1097/00007632-200302150-00018 PubMed Mirza SK, Wiggins GC, Ct Kuntz, York JE, Bellabarba C, Knonodi MA, Chapman JR, Shaffrey CI (2003) Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance: a cadaver study. Spine 28:402–413. doi:10.​1097/​00007632-200302150-00018 PubMed
69.
Zurück zum Zitat Newport R, Hindle JV, Jackson SR (2001) Links between vision and somatosensation. Vision can improve the felt position of the unseen hand. Curr Biol 11:975–980. doi:S0960-9822(01)00266-4[pii] PubMed Newport R, Hindle JV, Jackson SR (2001) Links between vision and somatosensation. Vision can improve the felt position of the unseen hand. Curr Biol 11:975–980. doi:S0960-9822(01)00266-4[pii] PubMed
70.
Zurück zum Zitat Nolte LP, Visarius H, Arm E, Langlotz F, Schwarzenbach O, Zamorano L (1995) Computer-aided fixation of spinal implants. J Image Guided Surg 1:88–9369 Nolte LP, Visarius H, Arm E, Langlotz F, Schwarzenbach O, Zamorano L (1995) Computer-aided fixation of spinal implants. J Image Guided Surg 1:88–9369
71.
Zurück zum Zitat Nolte LP, Zamorano L, Visarius H, Berlemann U, Langlotz F, Arm E, Schwarzenbach O (1995) Clinical evaluation of a system for precision enhancement in spine surgery. Clin Biomech (Bristol, Avon) 10:293–303. doi:10.1016/0268-0033(95)00004-5 Nolte LP, Zamorano L, Visarius H, Berlemann U, Langlotz F, Arm E, Schwarzenbach O (1995) Clinical evaluation of a system for precision enhancement in spine surgery. Clin Biomech (Bristol, Avon) 10:293–303. doi:10.​1016/​0268-0033(95)00004-5
72.
Zurück zum Zitat Nottmeier EW, Crosby TL (2007) Timing of paired points and surface matching registration in three-dimensional (3D) image-guided spinal surgery. J Spinal Disord Tech 20:268–270PubMed Nottmeier EW, Crosby TL (2007) Timing of paired points and surface matching registration in three-dimensional (3D) image-guided spinal surgery. J Spinal Disord Tech 20:268–270PubMed
74.
Zurück zum Zitat Ohnsorge JA, Siebert CH, Schkommodau E, Mahnken AH, Prescher A, Weisskopf M (2005) Minimally-invasive computer-assisted fluoroscopic navigation for kyphoplasty. Z Orthop Ihre Grenzgeb 143:195–203. doi:10.1055/s-2005-836514 PubMed Ohnsorge JA, Siebert CH, Schkommodau E, Mahnken AH, Prescher A, Weisskopf M (2005) Minimally-invasive computer-assisted fluoroscopic navigation for kyphoplasty. Z Orthop Ihre Grenzgeb 143:195–203. doi:10.​1055/​s-2005-836514 PubMed
75.
Zurück zum Zitat Paramore CG, Dickman CA, Sonntag VK (1996) The anatomical suitability of the C1-2 complex for transarticular screw fixation. J Neurosurg 85:221–224PubMed Paramore CG, Dickman CA, Sonntag VK (1996) The anatomical suitability of the C1-2 complex for transarticular screw fixation. J Neurosurg 85:221–224PubMed
77.
79.
80.
Zurück zum Zitat Rajasekaran S, Vidyadhara S, Shetty AP (2007) Intra-operative Iso-C3D navigation for pedicle screw instrumentation of hangman’s fracture: a case report. J Orthop Surg (Hong Kong) 15:73–77 Rajasekaran S, Vidyadhara S, Shetty AP (2007) Intra-operative Iso-C3D navigation for pedicle screw instrumentation of hangman’s fracture: a case report. J Orthop Surg (Hong Kong) 15:73–77
81.
84.
Zurück zum Zitat Reichle E, Sellenschloh K, Morlock M, Eggers C (2002) Placement of pedicle screws using different navigation systems. A laboratory trial with 12 spinal preparations. Orthopade 31:368–371. doi:10.1007/s00132-001-0277-6 PubMed Reichle E, Sellenschloh K, Morlock M, Eggers C (2002) Placement of pedicle screws using different navigation systems. A laboratory trial with 12 spinal preparations. Orthopade 31:368–371. doi:10.​1007/​s00132-001-0277-6 PubMed
85.
Zurück zum Zitat Reinhold M, Bach C, Audige L, Bale R, Attal R, Blauth M, Magerl F (2008) Comparison of two novel fluoroscopy-based stereotactic methods for cervical pedicle screw placement and review of the literature. Eur Spine J Reinhold M, Bach C, Audige L, Bale R, Attal R, Blauth M, Magerl F (2008) Comparison of two novel fluoroscopy-based stereotactic methods for cervical pedicle screw placement and review of the literature. Eur Spine J
87.
Zurück zum Zitat Ruf M, Wagner R, Merk H, Harms J (2006) Preoperative planning and computer assisted surgery in ankylosing spondylitis. Z Orthop Ihre Grenzgeb 144:52–57. doi:10.1055/s-2006-921484 PubMed Ruf M, Wagner R, Merk H, Harms J (2006) Preoperative planning and computer assisted surgery in ankylosing spondylitis. Z Orthop Ihre Grenzgeb 144:52–57. doi:10.​1055/​s-2006-921484 PubMed
88.
Zurück zum Zitat Rushworth MF, Nixon PD, Passingham RE (1997) Parietal cortex and movement. I. Movement selection and reaching. Exp Brain Res Experimentelle Hirnforschung 117:292–310 Rushworth MF, Nixon PD, Passingham RE (1997) Parietal cortex and movement. I. Movement selection and reaching. Exp Brain Res Experimentelle Hirnforschung 117:292–310
90.
Zurück zum Zitat Sakai Y, Matsuyama Y, Yoshihara H, Nakamura H, Nakashima S, Ishiguro N (2006) Simultaneous registration with ct-fluoro matching for spinal navigation surgery. A case report. Nagoya J Med Sci 68:45–52PubMed Sakai Y, Matsuyama Y, Yoshihara H, Nakamura H, Nakashima S, Ishiguro N (2006) Simultaneous registration with ct-fluoro matching for spinal navigation surgery. A case report. Nagoya J Med Sci 68:45–52PubMed
93.
Zurück zum Zitat Schaeren S, Roth J, Dick W (2002) Effective in vivo radiation dose with image reconstruction controlled pedicle instrumentation vs. CT-based navigation. Orthopade 31:392–396. doi:10.1007/s00132-001-0281-x Schaeren S, Roth J, Dick W (2002) Effective in vivo radiation dose with image reconstruction controlled pedicle instrumentation vs. CT-based navigation. Orthopade 31:392–396. doi:10.​1007/​s00132-001-0281-x
94.
Zurück zum Zitat Schnake KJ, Konig B, Berth U, Schroeder RJ, Kandziora F, Stockle U, Raschke M, Haas NP (2004) Accuracy of CT-based navitation of pedicle screws in the thoracic spine compared with conventional technique. Unfallchirurg 107:104–112. doi:10.1007/s00113-003-0720-8 PubMed Schnake KJ, Konig B, Berth U, Schroeder RJ, Kandziora F, Stockle U, Raschke M, Haas NP (2004) Accuracy of CT-based navitation of pedicle screws in the thoracic spine compared with conventional technique. Unfallchirurg 107:104–112. doi:10.​1007/​s00113-003-0720-8 PubMed
95.
Zurück zum Zitat Seichi A, Takeshita K, Kawaguchi H, Kawamura N, Higashikawa A, Nakamura K (2005) Image-guided surgery for thoracic ossification of the posterior longitudinal ligament. Technical note. J Neurosurg 3:165–168 Seichi A, Takeshita K, Kawaguchi H, Kawamura N, Higashikawa A, Nakamura K (2005) Image-guided surgery for thoracic ossification of the posterior longitudinal ligament. Technical note. J Neurosurg 3:165–168
96.
Zurück zum Zitat Seichi A, Takeshita K, Nakajima S, Akune T, Kawaguchi H, Nakamura K (2005) Revision cervical spine surgery using transarticular or pedicle screws under a computer-assisted image-guidance system. J Orthop Sci 10:385–390. doi:10.1007/s00776-005-0902-z PubMed Seichi A, Takeshita K, Nakajima S, Akune T, Kawaguchi H, Nakamura K (2005) Revision cervical spine surgery using transarticular or pedicle screws under a computer-assisted image-guidance system. J Orthop Sci 10:385–390. doi:10.​1007/​s00776-005-0902-z PubMed
97.
Zurück zum Zitat Siewerdsen JH, Moseley DJ, Burch S, Bisland SK, Bogaards A, Wilson BC, Jaffray DA (2005) Volume CT with a flat-panel detector on a mobile, isocentric C-arm: pre-clinical investigation in guidance of minimally invasive surgery. Med Phys 32:241–254. doi:10.1118/1.1836331 PubMed Siewerdsen JH, Moseley DJ, Burch S, Bisland SK, Bogaards A, Wilson BC, Jaffray DA (2005) Volume CT with a flat-panel detector on a mobile, isocentric C-arm: pre-clinical investigation in guidance of minimally invasive surgery. Med Phys 32:241–254. doi:10.​1118/​1.​1836331 PubMed
98.
Zurück zum Zitat Slomczykowski M, Roberto M, Schneeberger P, Ozdoba C, Vock P (1999) Radiation dose for pedicle screw insertion. Fluoroscopic method versus computer-assisted surgery. Spine 24:975–982. doi:10.1097/00007632-199905150-00009 (discussion 983)PubMed Slomczykowski M, Roberto M, Schneeberger P, Ozdoba C, Vock P (1999) Radiation dose for pedicle screw insertion. Fluoroscopic method versus computer-assisted surgery. Spine 24:975–982. doi:10.​1097/​00007632-199905150-00009 (discussion 983)PubMed
100.
Zurück zum Zitat Theocharopoulos N, Perisinakis K, Damilakis J, Papadokostakis G, Hadjipavlou A, Gourtsoyiannis N (2003) Occupational exposure from common fluoroscopic projections used in orthopaedic surgery. J Bone Joint Surg Am 85-A:1698–1703PubMed Theocharopoulos N, Perisinakis K, Damilakis J, Papadokostakis G, Hadjipavlou A, Gourtsoyiannis N (2003) Occupational exposure from common fluoroscopic projections used in orthopaedic surgery. J Bone Joint Surg Am 85-A:1698–1703PubMed
101.
Zurück zum Zitat Thoranaghatte R, Zheng G, Nolte LP (2005) Novel method for registering an endoscope in an operative setup. Conf Proc IEEE Eng Med Biol Soc 4:4349–4352PubMed Thoranaghatte R, Zheng G, Nolte LP (2005) Novel method for registering an endoscope in an operative setup. Conf Proc IEEE Eng Med Biol Soc 4:4349–4352PubMed
102.
Zurück zum Zitat Thoranaghatte RU, Zheng G, Langlotz F, Nolte LP (2005) Endoscope-based hybrid navigation system for minimally invasive ventral spine surgeries. Comput Aided Surg 10:351–356. doi:10.1080/10929080500389738 PubMed Thoranaghatte RU, Zheng G, Langlotz F, Nolte LP (2005) Endoscope-based hybrid navigation system for minimally invasive ventral spine surgeries. Comput Aided Surg 10:351–356. doi:10.​1080/​1092908050038973​8 PubMed
103.
Zurück zum Zitat Vaccaro AR, Yuan PS, Smith HE, Hott J, Sasso R, Papadopoulos S (2005) An evaluation of image-guided technologies in the placement of anterior thoracic vertebral body screws in spinal trauma: a cadaver study. J Spinal Cord Med 28:308–313PubMed Vaccaro AR, Yuan PS, Smith HE, Hott J, Sasso R, Papadopoulos S (2005) An evaluation of image-guided technologies in the placement of anterior thoracic vertebral body screws in spinal trauma: a cadaver study. J Spinal Cord Med 28:308–313PubMed
104.
Zurück zum Zitat Van Royen BJ, Baayen JC, Pijpers R, Noske DP, Schakenraad D, Wuisman PI (2005) Osteoid osteoma of the spine: a novel technique using combined computer-assisted and gamma probe-guided high-speed intralesional drill excision. Spine 30:369–373. doi:10.1097/01.brs.0000152531.49095.34 PubMed Van Royen BJ, Baayen JC, Pijpers R, Noske DP, Schakenraad D, Wuisman PI (2005) Osteoid osteoma of the spine: a novel technique using combined computer-assisted and gamma probe-guided high-speed intralesional drill excision. Spine 30:369–373. doi:10.​1097/​01.​brs.​0000152531.​49095.​34 PubMed
106.
107.
Zurück zum Zitat Weinstein JN, Spratt KF, Spengler D, Brick C, Reid S (1988) Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine 13:1012–1018. doi:10.1097/00007632-198809000-00008 PubMed Weinstein JN, Spratt KF, Spengler D, Brick C, Reid S (1988) Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine 13:1012–1018. doi:10.​1097/​00007632-198809000-00008 PubMed
108.
Zurück zum Zitat Wendl K, von Recum J, Wentzensen A, Grutzner PA (2003) Iso-C(3D0-assisted) navigated implantation of pedicle screws in thoracic lumbar vertebrae. Unfallchirurg 106:907–913PubMed Wendl K, von Recum J, Wentzensen A, Grutzner PA (2003) Iso-C(3D0-assisted) navigated implantation of pedicle screws in thoracic lumbar vertebrae. Unfallchirurg 106:907–913PubMed
110.
111.
Zurück zum Zitat Youkilis AS, Quint DJ, McGillicuddy JE, Papadopoulos SM (2001) Stereotactic navigation for placement of pedicle screws in the thoracic spine. Neurosurgery 48:771-778, discussion 778–779PubMed Youkilis AS, Quint DJ, McGillicuddy JE, Papadopoulos SM (2001) Stereotactic navigation for placement of pedicle screws in the thoracic spine. Neurosurgery 48:771-778, discussion 778–779PubMed
Metadaten
Titel
Image-guided spine surgery: state of the art and future directions
verfasst von
Thorsten Tjardes
Sven Shafizadeh
Dieter Rixen
Thomas Paffrath
Bertil Bouillon
Eva S. Steinhausen
Holger Baethis
Publikationsdatum
01.01.2010
Verlag
Springer-Verlag
Erschienen in
European Spine Journal / Ausgabe 1/2010
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-009-1091-9

Weitere Artikel der Ausgabe 1/2010

European Spine Journal 1/2010 Zur Ausgabe

Announcements

Announcements

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.