Skip to main content
Erschienen in: European Spine Journal 10/2014

01.10.2014 | Original Article

Volumetric change in interbody bone graft after posterior lumbar interbody fusion (PLIF): a prospective study

verfasst von: Zenya Ito, Shiro Imagama, Tokumi Kanemura, Kotaro Satake, Kei Ando, Kazuyoshi Kobayashi, Ryuichi Shinjo, Hideki Yagi, Tetsuro Hida, Kenyu Ito, Yoshimoto Ishikawa, Mikito Tsushima, Akiyuki Matsumoto, Hany El Zahlawy, Hidetoshi Yamaguchi, Yukihiro Matsuyama, Naoki Ishiguro

Erschienen in: European Spine Journal | Ausgabe 10/2014

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The purpose of this study is to quantify the change in the volume of the interbody bone graft after the PLIF and monitor the change over time for subsequent analysis.

Methods

The 114 cases were selected as the subjects of this study. The observation period was for 5 years following the surgery. The volume of the bone graft in the interbody space was calculated by summing up the cross-sectional area of the bone graft on each axial image multiplied by the height (2 mm) (the volume of the two cages was excluded). The volume ratio (%) = (bone graft volume)/(total volume of the interbody space − cage volume) was used for the purpose of evaluation.

Results

The volumetric change of the bone graft was 51 % (3 months), 53 % (6 months), 54 % (1 year), 55 % (2 years), 59 % (3 years), 62 % (4 years), and 72 % (5 years), indicating a continued increase up to the 5-year mark. In particular, a significant increase was observed from the second year as compared with the previous years’ result. Additionally, the volumetric increase from the second year to the fifth year was significantly higher than that before the second year.

Conclusions

The post-PLIF volumes of interbody bone grafts exhibited increases particularly from the second to fifth years after the procedure. Even the elderly and those with poor bone qualities can expect to have volumetric increases over time. Sufficient interbody space should be secured for accommodating bone grafts by intraoperative reduction, wherever possible.
Literatur
1.
Zurück zum Zitat Tokuhashi Y, Matsuzaki H, Oda H, Uei H (2008) Clinical course and significance of the clear zone around the pedicle screws in the lumbar degenerative disease. Spine 33(8):903–908PubMedCrossRef Tokuhashi Y, Matsuzaki H, Oda H, Uei H (2008) Clinical course and significance of the clear zone around the pedicle screws in the lumbar degenerative disease. Spine 33(8):903–908PubMedCrossRef
2.
Zurück zum Zitat Ito Z, Matsuyama Y, Sakai Y, Imagama S, Wakao N, Ando K, Hirano K, Tauchi R, Muramoto A, Matsui H, Matsumoto T, Kanemura T, Yoshida G, Ishikawa Y, Ishiguro N (2010) Bone union rate with autologous iliac bone versus local bone graft in posterior lumbar interbody fusion. Spine 35(21):E1101–E1105PubMedCrossRef Ito Z, Matsuyama Y, Sakai Y, Imagama S, Wakao N, Ando K, Hirano K, Tauchi R, Muramoto A, Matsui H, Matsumoto T, Kanemura T, Yoshida G, Ishikawa Y, Ishiguro N (2010) Bone union rate with autologous iliac bone versus local bone graft in posterior lumbar interbody fusion. Spine 35(21):E1101–E1105PubMedCrossRef
3.
Zurück zum Zitat Brantigan JW, Steffee AD, Lewis ML et al (2000) Lumbar interbody fusion using the Brantigan I/F cage for posterior lumbar interbody fusion and the variable pedicle screw placement system: two-year results from a Food and Drug Administration investigational device exemption clinical trial. Spine 25:1437–1446PubMedCrossRef Brantigan JW, Steffee AD, Lewis ML et al (2000) Lumbar interbody fusion using the Brantigan I/F cage for posterior lumbar interbody fusion and the variable pedicle screw placement system: two-year results from a Food and Drug Administration investigational device exemption clinical trial. Spine 25:1437–1446PubMedCrossRef
4.
Zurück zum Zitat Agazzi S, Reverdin A, May D (1999) Posterior lumbar interbody fusion with cages: an independent review of 71 cases. J Neurosurg 91:186–192PubMed Agazzi S, Reverdin A, May D (1999) Posterior lumbar interbody fusion with cages: an independent review of 71 cases. J Neurosurg 91:186–192PubMed
5.
Zurück zum Zitat Christensen FB, Hansen ES, Eiskjaer SP et al (2002) Circumferential lumbar spinal fusion with Brantigan cage versus posterolateral fusion with titanium Cotrel–Dubousset instrumentation: a prospective, randomized clinical study of 146 patients. Spine 27:2674–2683PubMedCrossRef Christensen FB, Hansen ES, Eiskjaer SP et al (2002) Circumferential lumbar spinal fusion with Brantigan cage versus posterolateral fusion with titanium Cotrel–Dubousset instrumentation: a prospective, randomized clinical study of 146 patients. Spine 27:2674–2683PubMedCrossRef
6.
Zurück zum Zitat Hashimoto T, Shigenobu K, Kanayama M et al (2002) Clinical results of single-level posterior lumbar interbody fusion using the Brantigan I/F carbon cage filled with a mixture of local morselized bone and bioactive ceramic granules. Spine 27:258–262PubMedCrossRef Hashimoto T, Shigenobu K, Kanayama M et al (2002) Clinical results of single-level posterior lumbar interbody fusion using the Brantigan I/F carbon cage filled with a mixture of local morselized bone and bioactive ceramic granules. Spine 27:258–262PubMedCrossRef
7.
Zurück zum Zitat Su KK, Ki YT, Lee JC (2005) Radiological changes in the bone fusion site after posterior lumbar interbody fusion using carbon cages impacted with laminar bone chips: follow-up study over more than 4 years. Spine 30:655–660CrossRef Su KK, Ki YT, Lee JC (2005) Radiological changes in the bone fusion site after posterior lumbar interbody fusion using carbon cages impacted with laminar bone chips: follow-up study over more than 4 years. Spine 30:655–660CrossRef
8.
Zurück zum Zitat Diedrich O, Perlick L, Schmitt O et al (2001) Radiographic characteristics on conventional radiographs after posterior lumbar interbody fusion: comparative study between radiotranslucent and radiopaque cages. J Spinal Disord 14:522–532PubMedCrossRef Diedrich O, Perlick L, Schmitt O et al (2001) Radiographic characteristics on conventional radiographs after posterior lumbar interbody fusion: comparative study between radiotranslucent and radiopaque cages. J Spinal Disord 14:522–532PubMedCrossRef
9.
Zurück zum Zitat An HS, Lynch K, Toth J (1995) Prospective comparison of autograft vs. allograft for adult posterolateral lumbar spine fusion: differences among freeze-dried, frozen, and mixed grafts. J Spinal Disord 8:131–135PubMedCrossRef An HS, Lynch K, Toth J (1995) Prospective comparison of autograft vs. allograft for adult posterolateral lumbar spine fusion: differences among freeze-dried, frozen, and mixed grafts. J Spinal Disord 8:131–135PubMedCrossRef
10.
Zurück zum Zitat Le Huec JC, Lesprit E, Delavigne C et al (1997) Tri-calcium phosphate ceramics and allografts as bone substitutes for spinal fusion in idiopathic scoliosis: comparative clinical results at four years. Acta Orthop Belg 63:202–211PubMed Le Huec JC, Lesprit E, Delavigne C et al (1997) Tri-calcium phosphate ceramics and allografts as bone substitutes for spinal fusion in idiopathic scoliosis: comparative clinical results at four years. Acta Orthop Belg 63:202–211PubMed
11.
Zurück zum Zitat Frenkel SR, Moskovich R, Spivak J et al (1993) Demineralized bone matrix. Enhancement of spinal fusion. Spine 18:1634–1639PubMedCrossRef Frenkel SR, Moskovich R, Spivak J et al (1993) Demineralized bone matrix. Enhancement of spinal fusion. Spine 18:1634–1639PubMedCrossRef
12.
Zurück zum Zitat Holliger EH, Trawick RH, Boden SD et al (1996) Morphology of the lumbar intertransverse process fusion mass in the rabbit model: a comparison between two bone graft materials-rhBMP-2 and autograft. J Spinal Disord 9:125–128PubMedCrossRef Holliger EH, Trawick RH, Boden SD et al (1996) Morphology of the lumbar intertransverse process fusion mass in the rabbit model: a comparison between two bone graft materials-rhBMP-2 and autograft. J Spinal Disord 9:125–128PubMedCrossRef
13.
Zurück zum Zitat Tay BK, Le AX, Heilman M et al (1998) Use of a collagen-hydroxyapatite matrix in spinal fusion. A rabbit model. Spine 23:2276–2281PubMedCrossRef Tay BK, Le AX, Heilman M et al (1998) Use of a collagen-hydroxyapatite matrix in spinal fusion. A rabbit model. Spine 23:2276–2281PubMedCrossRef
14.
Zurück zum Zitat Miura Y, Imagama S, Yoda M et al (2003) Is local bone viable as a source of bone graft in posterior lumbar interbody fusion? Spine 28:2386–2389PubMedCrossRef Miura Y, Imagama S, Yoda M et al (2003) Is local bone viable as a source of bone graft in posterior lumbar interbody fusion? Spine 28:2386–2389PubMedCrossRef
15.
Zurück zum Zitat Ito Z, Imagama S, Kanemura T et al (2013) Bone union rate with autologous iliac bone versus local bone graft in posterior lumbar interbody fusion (PLIF): a multicenter study. Eur Spine J 22(5):1158–1163PubMedCrossRefPubMedCentral Ito Z, Imagama S, Kanemura T et al (2013) Bone union rate with autologous iliac bone versus local bone graft in posterior lumbar interbody fusion (PLIF): a multicenter study. Eur Spine J 22(5):1158–1163PubMedCrossRefPubMedCentral
16.
Zurück zum Zitat Thaler M, Lechner R, Gstottner M et al (2013) The use of beta-tricalcium phosphate and bone marrow aspirate as a bone graft substitute in posterior lumbar interbody fusion. Eur Spine J 22(5):1173–1182PubMedCrossRefPubMedCentral Thaler M, Lechner R, Gstottner M et al (2013) The use of beta-tricalcium phosphate and bone marrow aspirate as a bone graft substitute in posterior lumbar interbody fusion. Eur Spine J 22(5):1173–1182PubMedCrossRefPubMedCentral
17.
Zurück zum Zitat Kim H, Lee CK, Yeom JS et al (2012) The efficacy of porous hydroxyapatite bone chip as an extender of local bone graft in posterior lumbar interbody fusion. Eur Spine J 21(7):1324–1330PubMedCrossRefPubMedCentral Kim H, Lee CK, Yeom JS et al (2012) The efficacy of porous hydroxyapatite bone chip as an extender of local bone graft in posterior lumbar interbody fusion. Eur Spine J 21(7):1324–1330PubMedCrossRefPubMedCentral
18.
Zurück zum Zitat Mura PP, Costaglioli M, Piredda M et al (2011) TLIF for symptomatic disc degeneration: a retrospective study of 100 patients. Eur Spine J 20 Suppl 1:S57–S60PubMedCrossRef Mura PP, Costaglioli M, Piredda M et al (2011) TLIF for symptomatic disc degeneration: a retrospective study of 100 patients. Eur Spine J 20 Suppl 1:S57–S60PubMedCrossRef
19.
Zurück zum Zitat Nakashima H, Yukawa Y, Ito K et al (2011) Extension CT scan: its suitability for assessing fusion after posterior lumbar interbody fusion. Eur Spine J 20(9):1496–1502PubMedCrossRefPubMedCentral Nakashima H, Yukawa Y, Ito K et al (2011) Extension CT scan: its suitability for assessing fusion after posterior lumbar interbody fusion. Eur Spine J 20(9):1496–1502PubMedCrossRefPubMedCentral
20.
Zurück zum Zitat Younger EM, Chapman MW (1989) Morbidity at bone graft donor sites. J Orthop Trauma 3:192–195PubMedCrossRef Younger EM, Chapman MW (1989) Morbidity at bone graft donor sites. J Orthop Trauma 3:192–195PubMedCrossRef
21.
Zurück zum Zitat Keller EE, Triplett WW (1987) Iliac bone grafting: review of 160 consecutive cases. J Oral Maxillofac Surg 45:11–14PubMedCrossRef Keller EE, Triplett WW (1987) Iliac bone grafting: review of 160 consecutive cases. J Oral Maxillofac Surg 45:11–14PubMedCrossRef
22.
Zurück zum Zitat Summers BN, Eisenstein SM (1989) Donor site pain from the ilium: a complication of lumbar spine fusion. J Bone Joint Surg Br 71:677–680PubMed Summers BN, Eisenstein SM (1989) Donor site pain from the ilium: a complication of lumbar spine fusion. J Bone Joint Surg Br 71:677–680PubMed
23.
Zurück zum Zitat Robertson PA, Wray AC (2001) Natural history of posterior iliac crest bone graft donation for spinal surgery: a prospective analysis of morbidity. Spine 26:1473–1476PubMedCrossRef Robertson PA, Wray AC (2001) Natural history of posterior iliac crest bone graft donation for spinal surgery: a prospective analysis of morbidity. Spine 26:1473–1476PubMedCrossRef
24.
Zurück zum Zitat Brown CW, Orme TJ, Richardson HD (1986) The rate of pseudarthrosis (surgical nonunion) in patients who are smokers and patients who are nonsmokers: a comparison study. Spine 11(9):942–943PubMedCrossRef Brown CW, Orme TJ, Richardson HD (1986) The rate of pseudarthrosis (surgical nonunion) in patients who are smokers and patients who are nonsmokers: a comparison study. Spine 11(9):942–943PubMedCrossRef
25.
Zurück zum Zitat Daftari TK, Whitesides TE Jr, Heller JG, Goodrich AC, McCarey BE, Hutton WC (1994) Nicotine on the revascularization of bone graft. An experimental study in rabbits. Spine 19(8):904–911PubMedCrossRef Daftari TK, Whitesides TE Jr, Heller JG, Goodrich AC, McCarey BE, Hutton WC (1994) Nicotine on the revascularization of bone graft. An experimental study in rabbits. Spine 19(8):904–911PubMedCrossRef
26.
Zurück zum Zitat Silcox DH 3rd, Daftari T, Boden SD, Schimandle JH, Hutton WC, Whitesides TE Jr (1995) Effect of nicotine on spinal fusion. Spine 20(14):1549–1553PubMedCrossRef Silcox DH 3rd, Daftari T, Boden SD, Schimandle JH, Hutton WC, Whitesides TE Jr (1995) Effect of nicotine on spinal fusion. Spine 20(14):1549–1553PubMedCrossRef
27.
Zurück zum Zitat Theiss SM, Boden SD, Hair G, Titus L, Morone MA, Ugbo J (2000) The effect of nicotine on gene expression during spine fusion. Spine 25(20):2588–2594PubMedCrossRef Theiss SM, Boden SD, Hair G, Titus L, Morone MA, Ugbo J (2000) The effect of nicotine on gene expression during spine fusion. Spine 25(20):2588–2594PubMedCrossRef
28.
Zurück zum Zitat Glassman SD, Anagnost SC, Parker A, Burke D, Johnson JR, Dimar JR (2000) The effect of cigarette smoking and smoking cessation on spinal fusion. Spine 25(20):2608–2615PubMedCrossRef Glassman SD, Anagnost SC, Parker A, Burke D, Johnson JR, Dimar JR (2000) The effect of cigarette smoking and smoking cessation on spinal fusion. Spine 25(20):2608–2615PubMedCrossRef
Metadaten
Titel
Volumetric change in interbody bone graft after posterior lumbar interbody fusion (PLIF): a prospective study
verfasst von
Zenya Ito
Shiro Imagama
Tokumi Kanemura
Kotaro Satake
Kei Ando
Kazuyoshi Kobayashi
Ryuichi Shinjo
Hideki Yagi
Tetsuro Hida
Kenyu Ito
Yoshimoto Ishikawa
Mikito Tsushima
Akiyuki Matsumoto
Hany El Zahlawy
Hidetoshi Yamaguchi
Yukihiro Matsuyama
Naoki Ishiguro
Publikationsdatum
01.10.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
European Spine Journal / Ausgabe 10/2014
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-014-3410-z

Weitere Artikel der Ausgabe 10/2014

European Spine Journal 10/2014 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.