Skip to main content
Erschienen in: European Spine Journal 12/2015

01.12.2015 | Original Article

Feasibility and trajectory study of anterior transarticular crossing screw placement for atlantoaxial joint instability: a cadaveric study and description of a novel technique

verfasst von: Wei Ji, Minghui Zheng, Jie Tong, Zhiping Huang, Jianting Chen, Dongbin Qu, Qingan Zhu

Erschienen in: European Spine Journal | Ausgabe 12/2015

Einloggen, um Zugang zu erhalten

Abstract

Purpose

In unique clinical situations where C1–C2 anterior transarticular screw (ATS) fixation is not available or has failed, an anterior transarticular crossing screw (ATCS) with transcorporal pathway of the screws inside the contralateral promontory of C2 may enhance the stabilization and achieve atlantoaxial arthrodesis. The present study was to describe a novel technique of ATCS fixation for atlantoaxial joint instability and its applied anatomy, and compared it with ATS fixation method.

Methods

Direct measurements using digital calipers and a goniometer were conducted on 30 pairs of dried human C1 and C2 vertebrae. The ATS and ATCS with screws (Φ 4.0 mm) were performed on 11 fresh cervical spine specimens. The screw lengths in the C1 and C2, and screw entry angles of the ATS and ATCS were measured, respectively. Cadaver specimens were dissected to observe the incidence of violation to the important structures surrounding the ATS and ATCS fixation technique.

Results

There was enough osseous space for ATCS placement. The lateral and incline angle of the ATCS was 36.2° and 28.7°, respectively. Screw purchase in C2 of the ATCS (25.6 mm) was greater than that of the ATS (11.4 mm). The ATCS C1 purchase (14.8 mm) was similar to the ATS C1 purchase (14.9 mm). No violation to the vertebral artery groove, the spinal canal or the atlanto-occipital joint was observed after the ATCS placement.

Conclusion

Anterior transarticular crossing screw is a feasible and viable option for atlantoaxial fixation in selected cases. This technique achieved remarkable longer screw purchase and could enhance the atlantoaxial stability.
Literatur
1.
Zurück zum Zitat Barbour JR (1971) Screw fixation in fractures of the odontoid process. S Aust Clin 5:20 Barbour JR (1971) Screw fixation in fractures of the odontoid process. S Aust Clin 5:20
2.
Zurück zum Zitat Lu J, Ebraheim NA, Yang H et al (1998) Anatomic considerations of anterior transarticular screw fixation for atlantoaxial instability. Spine 23:1229–1235CrossRefPubMed Lu J, Ebraheim NA, Yang H et al (1998) Anatomic considerations of anterior transarticular screw fixation for atlantoaxial instability. Spine 23:1229–1235CrossRefPubMed
3.
Zurück zum Zitat Reindl R, Sen M, Aebi M (2003) Anterior instrumentation for traumatic C1-C2 instability. Spine 28:E329–E333CrossRefPubMed Reindl R, Sen M, Aebi M (2003) Anterior instrumentation for traumatic C1-C2 instability. Spine 28:E329–E333CrossRefPubMed
4.
Zurück zum Zitat Sen MK, Steffen T, Beckman L et al (2005) Atlantoaxial fusion using anterior transarticular screw fixation of C1-C2: technical innovation and biomechanical study. Eur Spine J 14:512–518PubMedCentralCrossRefPubMed Sen MK, Steffen T, Beckman L et al (2005) Atlantoaxial fusion using anterior transarticular screw fixation of C1-C2: technical innovation and biomechanical study. Eur Spine J 14:512–518PubMedCentralCrossRefPubMed
5.
Zurück zum Zitat Li WL, Chi YL, Xu HZ et al (2010) Percutaneous anterior transarticular screw fixation for atlantoaxial instability: a case series. J Bone Joint Surg Br 92:545–549CrossRefPubMed Li WL, Chi YL, Xu HZ et al (2010) Percutaneous anterior transarticular screw fixation for atlantoaxial instability: a case series. J Bone Joint Surg Br 92:545–549CrossRefPubMed
6.
Zurück zum Zitat Padua MRA, Yeom JS, Lee SY et al (2013) Fluoroscopically guided anterior atlantoaxial transarticular screws: a feasibility and trajectory study using CT-based simulation software. Spine J 13:1455–1463CrossRefPubMed Padua MRA, Yeom JS, Lee SY et al (2013) Fluoroscopically guided anterior atlantoaxial transarticular screws: a feasibility and trajectory study using CT-based simulation software. Spine J 13:1455–1463CrossRefPubMed
7.
Zurück zum Zitat Koller H, Kammermeier V, Ulbricht D et al (2006) Anterior retropharyngeal fixation C1-2 for stabilization of atlantoaxial instabilities: study of feasibility, technical description and preliminary results. Eur Spine J 15:1326–1338PubMedCentralCrossRefPubMed Koller H, Kammermeier V, Ulbricht D et al (2006) Anterior retropharyngeal fixation C1-2 for stabilization of atlantoaxial instabilities: study of feasibility, technical description and preliminary results. Eur Spine J 15:1326–1338PubMedCentralCrossRefPubMed
8.
Zurück zum Zitat Cavalcanti DD, Agrawal A, Garcia-Gonzalez U et al (2010) Anterolateral C1-C2 transarticular fixation for atlantoaxial arthrodesis: landmarks, working area, and angles of approach. Neurosurgery 67:38–42 Cavalcanti DD, Agrawal A, Garcia-Gonzalez U et al (2010) Anterolateral C1-C2 transarticular fixation for atlantoaxial arthrodesis: landmarks, working area, and angles of approach. Neurosurgery 67:38–42
9.
Zurück zum Zitat Wang J, Zhou Y, Zhang Z et al (2012) Minimally invasive anterior transarticular screw fixation and microendoscopic bone graft for atlantoaxial instability. Eur Spine J 21:1568–1574PubMedCentralCrossRefPubMed Wang J, Zhou Y, Zhang Z et al (2012) Minimally invasive anterior transarticular screw fixation and microendoscopic bone graft for atlantoaxial instability. Eur Spine J 21:1568–1574PubMedCentralCrossRefPubMed
10.
Zurück zum Zitat Kansal R, Sharma A, Kukreja S (2011) An anterior high cervical retropharyngeal approach for C1-C2 intrafacetal fusion and transarticular screw insertion. J Clin Neurosci 18:1705–1708CrossRefPubMed Kansal R, Sharma A, Kukreja S (2011) An anterior high cervical retropharyngeal approach for C1-C2 intrafacetal fusion and transarticular screw insertion. J Clin Neurosci 18:1705–1708CrossRefPubMed
11.
Zurück zum Zitat Polli FM, Miscusi M, Forcato S et al (2015) Atlantoaxial anterior transarticular screw fixation: a case series and reappraisal of the technique. Spine J 15:185–193CrossRefPubMed Polli FM, Miscusi M, Forcato S et al (2015) Atlantoaxial anterior transarticular screw fixation: a case series and reappraisal of the technique. Spine J 15:185–193CrossRefPubMed
12.
Zurück zum Zitat Xu H, Chi YL, Wang XY et al (2012) Comparison of the anatomic risk for vertebral artery injury associated with percutaneous atlantoaxial anterior and posterior transarticular screws. Spine J 12:656–662CrossRefPubMed Xu H, Chi YL, Wang XY et al (2012) Comparison of the anatomic risk for vertebral artery injury associated with percutaneous atlantoaxial anterior and posterior transarticular screws. Spine J 12:656–662CrossRefPubMed
13.
Zurück zum Zitat Lapsiwala SB, Anderson PA, Oza A et al (2006) Biomechanical comparison of four C1 to C2 rigid fixative techniques: anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws. Neurosurgery 58:516–521CrossRefPubMed Lapsiwala SB, Anderson PA, Oza A et al (2006) Biomechanical comparison of four C1 to C2 rigid fixative techniques: anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws. Neurosurgery 58:516–521CrossRefPubMed
14.
Zurück zum Zitat Cacciola F, Phalke U, Goel A (2004) Vertebral artery in relationship to C1-C2 vertebrae: an anatomical study. Neurol India 52:178–184PubMed Cacciola F, Phalke U, Goel A (2004) Vertebral artery in relationship to C1-C2 vertebrae: an anatomical study. Neurol India 52:178–184PubMed
15.
Zurück zum Zitat Peng CW, Chou BT, Bendo JA, Spivak JM (2009) Vertebral artery injury in cervical spine surgery: anatomical considerations, management, and preventive measures. Spine J 9:70–76CrossRefPubMed Peng CW, Chou BT, Bendo JA, Spivak JM (2009) Vertebral artery injury in cervical spine surgery: anatomical considerations, management, and preventive measures. Spine J 9:70–76CrossRefPubMed
16.
Zurück zum Zitat Finn MA, Apfelbaum RI (2010) Atlantoaxial transarticular screw fixation: update on technique and outcomes in 269 patients. Neurosurgery 66:184–192CrossRefPubMed Finn MA, Apfelbaum RI (2010) Atlantoaxial transarticular screw fixation: update on technique and outcomes in 269 patients. Neurosurgery 66:184–192CrossRefPubMed
17.
Zurück zum Zitat Kandziora F, Schulze-Stahl N, Khodadadyan-Klostermann C, Schroder R, Mittlmeier T (2001) Screw placement in transoral atlantoaxial plate systems: an anatomical study. J Neurosurg 95:80–87PubMed Kandziora F, Schulze-Stahl N, Khodadadyan-Klostermann C, Schroder R, Mittlmeier T (2001) Screw placement in transoral atlantoaxial plate systems: an anatomical study. J Neurosurg 95:80–87PubMed
Metadaten
Titel
Feasibility and trajectory study of anterior transarticular crossing screw placement for atlantoaxial joint instability: a cadaveric study and description of a novel technique
verfasst von
Wei Ji
Minghui Zheng
Jie Tong
Zhiping Huang
Jianting Chen
Dongbin Qu
Qingan Zhu
Publikationsdatum
01.12.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
European Spine Journal / Ausgabe 12/2015
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-015-4135-3

Weitere Artikel der Ausgabe 12/2015

European Spine Journal 12/2015 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.