Purpose

The cervical pedicle screw (CPS) requires careful and accurate placement because of the critical risk for neurovascular injury. This study aimed to introduce and evaluate the safety and efficacy of a new CPS placement technique using intraoperative C-arm cone-beam CT (CBCT) and a pilot screw without navigation system.

Methods

This was a case–control study to compare the accuracy and safety of intraoperative C-arm CBCT-guided CPS placement with freehand CPS placement under lateral fluoroscopy using control data from a previous multicenter study. A total of 166 CPSs were inserted under intraoperative C-arm CBCT guidance in 48 consecutive patients (20 rheumatoid arthritis, 16 degenerative spinal disorders, 6 spinal tumor, 2 congenital deformity, 2 ossification of posterior longitudinal ligament, and 2 fracture dislocation). Accuracy and safety of CPS placement were assessed.

Results

The overall malposition rate was 2.4% (4 screws in grade 1: malposition by less than half-screw diameter, 0 in grade 2: malposition by more than half-screw diameter), which was significantly lower than the reported malposition rate of 14.8% in lateral fluoroscopy-guided freehand placement. There were no complications directly related to CPS insertion. The average estimated effective radiation dose per surgery was 14.7 mSv.

Conclusions

The novel technique enables intraoperative adjustment of the trajectory of the CPS as well as confirmation of the CPS path before penetrating the isthmus of the pedicle, resulting in accurate and safe CPS placement, which outweighs the demerits of radiation exposure.

Graphical abstract

These slides can be retrieved under Electronic Supplementary Material.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
2.
Zurück zum Zitat Hojo Y, Ito M, Suda K, Oda I, Yoshimoto H, Abumi K (2014) A multicenter study on accuracy and complications of freehand placement of cervical pedicle screws under lateral fluoroscopy in different pathological conditions: CT-based evaluation of more than 1,000 screws. Eur Spine J 23:2166–2174. https://doi.org/10.1007/s00586-014-3470-0 CrossRefPubMed Hojo Y, Ito M, Suda K, Oda I, Yoshimoto H, Abumi K (2014) A multicenter study on accuracy and complications of freehand placement of cervical pedicle screws under lateral fluoroscopy in different pathological conditions: CT-based evaluation of more than 1,000 screws. Eur Spine J 23:2166–2174. https://​doi.​org/​10.​1007/​s00586-014-3470-0 CrossRefPubMed
3.
Zurück zum Zitat Neo M, Sakamoto T, Fujibayashi S (2005) The clinical risk of vertebral artery injury from cervical pedicle screw inserted in degenerative vertebrae. Spine 30:2800–2805CrossRefPubMed Neo M, Sakamoto T, Fujibayashi S (2005) The clinical risk of vertebral artery injury from cervical pedicle screw inserted in degenerative vertebrae. Spine 30:2800–2805CrossRefPubMed
7.
Zurück zum Zitat Jeanneret B, Gebhard JS, Magerl F (1994) Transpedicular screw fixation of articular mass fracture-separation: results of an anatomical study and operative technique. J Spinal Disord 7(3):222–229CrossRefPubMed Jeanneret B, Gebhard JS, Magerl F (1994) Transpedicular screw fixation of articular mass fracture-separation: results of an anatomical study and operative technique. J Spinal Disord 7(3):222–229CrossRefPubMed
8.
Zurück zum Zitat Rhee JM, Kraiwattanapong C, Hutton WC (2005) A comparison of pedicle and lateral mass screw construct stiffnesses at the cervicothoracic junction: a biomechanical study. Spine 30(21):40CrossRef Rhee JM, Kraiwattanapong C, Hutton WC (2005) A comparison of pedicle and lateral mass screw construct stiffnesses at the cervicothoracic junction: a biomechanical study. Spine 30(21):40CrossRef
9.
Zurück zum Zitat Abumi K, Kaneda K (1997) Pedicle screw fixation for nontraumatic lesions of the cervical spine. Spine 22:1853–1863CrossRefPubMed Abumi K, Kaneda K (1997) Pedicle screw fixation for nontraumatic lesions of the cervical spine. Spine 22:1853–1863CrossRefPubMed
11.
Zurück zum Zitat Xu R, Ebraheim NA, Skie M (2008) Pedicle screw fixation in the cervical spine. Am J Orthop 37:403–408PubMed Xu R, Ebraheim NA, Skie M (2008) Pedicle screw fixation in the cervical spine. Am J Orthop 37:403–408PubMed
13.
23.
Metadaten
Titel
A novel technique of cervical pedicle screw placement with a pilot screw under the guidance of intraoperative 3D imaging from C-arm cone-beam CT without navigation for safe and accurate insertion
verfasst von
Masahiko Takahata
Katsuhisa Yamada
Iwata Akira
Tsutomu Endo
Hideki Sudo
Hidetoki Yokoyama
Norimasa Iwasaki
Publikationsdatum
23.07.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
European Spine Journal / Ausgabe 11/2018
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-018-5706-x

Weitere Artikel der Ausgabe 11/2018

European Spine Journal 11/2018 Zur Ausgabe

Announcements

Announcements

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.