Skip to main content
Erschienen in: European Journal of Orthopaedic Surgery & Traumatology 2/2014

01.02.2014 | Original Article

Retrospective comparison of external fixation versus volar locking plate in the treatment of unstable intra-articular distal radius fractures

verfasst von: Mert Kumbaraci, Levent Kucuk, Levent Karapinar, Cengizhan Kurt, Erhan Coskunol

Erschienen in: European Journal of Orthopaedic Surgery & Traumatology | Ausgabe 2/2014

Einloggen, um Zugang zu erhalten

Abstract

The aim of this study is to compare the radiological and functional outcomes of open reduction and volar locking plates versus external fixation (EF) in the treatment of unstable intra-articular distal radius fractures. In this retrospective comparative study, 69 of 80 patients who underwent an operation for AO/ASIF C1, C2 and C3 distal radius fractures were assessed. Functional evaluation was performed using the Gartland–Werley scoring system and the PRWE scale, and wrist range of motion and grip strength was also measured. For the radiological assessment, radial inclination, volar tilt, radial length, ulnar variance, and articular step-off were compared. The range of movement was better for all parameters in the volar plate group, but only wrist flexion and pronation range differed significantly between the groups (p = 0.037 and p = 0.014, respectively). With the exception of better subjective functional results in the volar plate group, the differences were not significant. With respect to radiological evaluation, all parameters were better in the volar plate group, but only radial inclination and articular step-off were significantly better (p = 0.018 and p = 0.029, respectively). In the volar plate group, two patients had carpal tunnel syndrome and one patient had regional pain syndrome. In the external fixator group, six patients had superficial pin tract infection, two patients had sensory branch injury, and four patients had regional pain syndrome. Volar locking plate fixation appeared as a dependable method for the treatment of intra-articular distal radius, with lower complication rates. On the other hand, EF remains a suitable surgical alternative for these fractures, with easy application and acceptable results.
Literatur
1.
Zurück zum Zitat Chung KC, Watt AJ, Kotsis SV et al (2006) Treatment of unstable distal radial fractures with the volar locking plating system. J Bone Jt Surg 88-A:2687–2694CrossRef Chung KC, Watt AJ, Kotsis SV et al (2006) Treatment of unstable distal radial fractures with the volar locking plating system. J Bone Jt Surg 88-A:2687–2694CrossRef
2.
Zurück zum Zitat Ruch DS, McQueen MM (2010) Distal radius and ulna fractures. In: Bucholz RW, Heckman JD, Court-Brown CM, Tornetta P (eds) Rockwood and green’s fractures in adults, 7th edn. Wolters Kluver, Philadelphia, pp 829–880 Ruch DS, McQueen MM (2010) Distal radius and ulna fractures. In: Bucholz RW, Heckman JD, Court-Brown CM, Tornetta P (eds) Rockwood and green’s fractures in adults, 7th edn. Wolters Kluver, Philadelphia, pp 829–880
3.
Zurück zum Zitat Fernandez DL, Wolfe SW (2005) Distal radius fractures. In: Green DP, Hotchkiss RN, Pederson WC, Wolfe SW (eds) Green’s operative hand surgery, 5th edn. Churchill Livingstone, Philadelphia, pp 645–710 Fernandez DL, Wolfe SW (2005) Distal radius fractures. In: Green DP, Hotchkiss RN, Pederson WC, Wolfe SW (eds) Green’s operative hand surgery, 5th edn. Churchill Livingstone, Philadelphia, pp 645–710
4.
Zurück zum Zitat Geissler WB, Fernandez DL (1991) Percutaneous and limited open reduction of the articular surface of the distal radius. J Orthop Trauma 5:255–264PubMedCrossRef Geissler WB, Fernandez DL (1991) Percutaneous and limited open reduction of the articular surface of the distal radius. J Orthop Trauma 5:255–264PubMedCrossRef
5.
Zurück zum Zitat Hove LM, Furnes O, Nilsen PT et al (1997) Closed reduction and external fixation of unstable fractures of distal radius. Scand J Plast Reconstr Surg Hand Surg 31:159–164PubMedCrossRef Hove LM, Furnes O, Nilsen PT et al (1997) Closed reduction and external fixation of unstable fractures of distal radius. Scand J Plast Reconstr Surg Hand Surg 31:159–164PubMedCrossRef
6.
Zurück zum Zitat Hutchinson DT, Strenz GO, Cautilli RA (1995) Pins and plaster vs external fixation in the treatment of unstable distal radius fractures. A randomized prospective study. J Hand Surg 20:365–372CrossRef Hutchinson DT, Strenz GO, Cautilli RA (1995) Pins and plaster vs external fixation in the treatment of unstable distal radius fractures. A randomized prospective study. J Hand Surg 20:365–372CrossRef
7.
Zurück zum Zitat Riis J, Fruensgaard S (1989) Treatment of unstable distal Colles’ fractures with external fixation. J Hand Surg 4:145–148CrossRef Riis J, Fruensgaard S (1989) Treatment of unstable distal Colles’ fractures with external fixation. J Hand Surg 4:145–148CrossRef
8.
Zurück zum Zitat Rikli DA, Kupfer K, Bodoky A (1998) Long term results of external fixation distal radius fractures. J Trauma 44:970–976PubMedCrossRef Rikli DA, Kupfer K, Bodoky A (1998) Long term results of external fixation distal radius fractures. J Trauma 44:970–976PubMedCrossRef
9.
Zurück zum Zitat Sanders RA, Keppel FL, Waldrop JI (1991) External fixation of distal radius fractures: results and complications. J Hand Surg 16:385–391CrossRef Sanders RA, Keppel FL, Waldrop JI (1991) External fixation of distal radius fractures: results and complications. J Hand Surg 16:385–391CrossRef
10.
Zurück zum Zitat Seitz WH Jr, Froimson AI, Leb R, Shapiro JD (1991) Augmented external fixation of unstable distal radius fractures. J Hand Surg 16:1010–1016CrossRef Seitz WH Jr, Froimson AI, Leb R, Shapiro JD (1991) Augmented external fixation of unstable distal radius fractures. J Hand Surg 16:1010–1016CrossRef
11.
Zurück zum Zitat Westphal T, Piatek S, Schubert S, Winckler S (2005) Outcome after surgery of distal radius fracture: no differences between external fixation and ORIF. Arch Orthop Trauma Surg 125:507–514PubMedCrossRef Westphal T, Piatek S, Schubert S, Winckler S (2005) Outcome after surgery of distal radius fracture: no differences between external fixation and ORIF. Arch Orthop Trauma Surg 125:507–514PubMedCrossRef
12.
Zurück zum Zitat Kreder HJ, Hanel DP, Agel J et al (2005) Indirect reduction and percutaneous fixation versus open reduction and internal fixation for displaced intra-articular fractures of the distal radius: a randomised, controlled trial. J Bone Jt Surg 87-B:829–836CrossRef Kreder HJ, Hanel DP, Agel J et al (2005) Indirect reduction and percutaneous fixation versus open reduction and internal fixation for displaced intra-articular fractures of the distal radius: a randomised, controlled trial. J Bone Jt Surg 87-B:829–836CrossRef
13.
Zurück zum Zitat Orbay JL, Fernandez DL (2002) Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg 27:205–215CrossRef Orbay JL, Fernandez DL (2002) Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg 27:205–215CrossRef
14.
Zurück zum Zitat Gartland JJ, Werley CW (1951) Evaluation of healed Colles fractures. J Bone Jt Surg 33-A:898–903 Gartland JJ, Werley CW (1951) Evaluation of healed Colles fractures. J Bone Jt Surg 33-A:898–903
15.
Zurück zum Zitat Frattini M, Soncini G, Corradi M et al (2009) Complex fractures of the distal radius treated with angular stability plates. Musculoskelet Surg 93:155–162CrossRef Frattini M, Soncini G, Corradi M et al (2009) Complex fractures of the distal radius treated with angular stability plates. Musculoskelet Surg 93:155–162CrossRef
16.
Zurück zum Zitat Dobretz H, Kutscha-Lissberg E (2003) Osteosynthesis of distal radial fractures with volar locking plate system. Int Orthop 27:1–6 Dobretz H, Kutscha-Lissberg E (2003) Osteosynthesis of distal radial fractures with volar locking plate system. Int Orthop 27:1–6
17.
Zurück zum Zitat Egol K, Walsh M, Tejwani N et al (2008) Bridging external fixation and supplementary Kirschner-wire fixation versus volar locked plating for the unstable fractures of the distal radius: a randomised, prospective trial. J Bone Joint Surg 90-A:1214–1221CrossRef Egol K, Walsh M, Tejwani N et al (2008) Bridging external fixation and supplementary Kirschner-wire fixation versus volar locked plating for the unstable fractures of the distal radius: a randomised, prospective trial. J Bone Joint Surg 90-A:1214–1221CrossRef
18.
Zurück zum Zitat Grewal R, Perey B, Wilmink M, Stothers K (2005) A randomized prospective study on the treatment of intra-articular distal radius fractures: open reduction and internal fixation with dorsal plating versus mini open reduction, percutaneous fixation, and external fixation. J Hand Surg 30:764–767CrossRef Grewal R, Perey B, Wilmink M, Stothers K (2005) A randomized prospective study on the treatment of intra-articular distal radius fractures: open reduction and internal fixation with dorsal plating versus mini open reduction, percutaneous fixation, and external fixation. J Hand Surg 30:764–767CrossRef
19.
Zurück zum Zitat Grewal R, MacDermid JC, King JC, Faber KJ (2011) Open reduction internal fixation versus percutaneous pinning with external fixation of distal radius fractures: a prospective, randomized clinical trial. J Hand Surg 36:1899–1906CrossRef Grewal R, MacDermid JC, King JC, Faber KJ (2011) Open reduction internal fixation versus percutaneous pinning with external fixation of distal radius fractures: a prospective, randomized clinical trial. J Hand Surg 36:1899–1906CrossRef
20.
Zurück zum Zitat Kamano M, Honda Y, Kazuki K, Yasuda M (2002) Palmar plating for dorsally displaced fractures of the distal radius. Clin Orthop Relat Res 397:403–408PubMedCrossRef Kamano M, Honda Y, Kazuki K, Yasuda M (2002) Palmar plating for dorsally displaced fractures of the distal radius. Clin Orthop Relat Res 397:403–408PubMedCrossRef
21.
Zurück zum Zitat Kamano M, Koshimune M, Kazuki K, Honda Y (2005) Palmar plating for AO/ASIF C 3.2 fractures of the distal radius with arthroscopically assisted reduction. Hand Surg 10:71–76PubMedCrossRef Kamano M, Koshimune M, Kazuki K, Honda Y (2005) Palmar plating for AO/ASIF C 3.2 fractures of the distal radius with arthroscopically assisted reduction. Hand Surg 10:71–76PubMedCrossRef
22.
Zurück zum Zitat Landgren M, Jerrhag D, Tagil M et al (2011) External or internal fixation in the treatment of non-reducible distal radial fractures? A 5-year follow-up of a randomized study involving 50 patients. Acta Orthop 82:610–613PubMedCrossRef Landgren M, Jerrhag D, Tagil M et al (2011) External or internal fixation in the treatment of non-reducible distal radial fractures? A 5-year follow-up of a randomized study involving 50 patients. Acta Orthop 82:610–613PubMedCrossRef
23.
Zurück zum Zitat Sakhaii M, Groenewold U, Klonz A, Reilmann H (2003) Results after palmar plate- osteosynthesis with angularly stable T-plate in 100 distal radius fractures: a prospective study. Unfallchirurg 106:272–280PubMedCrossRef Sakhaii M, Groenewold U, Klonz A, Reilmann H (2003) Results after palmar plate- osteosynthesis with angularly stable T-plate in 100 distal radius fractures: a prospective study. Unfallchirurg 106:272–280PubMedCrossRef
24.
Zurück zum Zitat Lattmann T, Meier C, Dietrich M, Forberger J, Platz A (2011) Results of volar locking plate osteosynthesis for distal radius fractures. J Trauma 70:1510–1518PubMedCrossRef Lattmann T, Meier C, Dietrich M, Forberger J, Platz A (2011) Results of volar locking plate osteosynthesis for distal radius fractures. J Trauma 70:1510–1518PubMedCrossRef
25.
Zurück zum Zitat Scmelzer-Schmeid N, Wieloch P, Martini AK (2009) Comparison of external fixation, locking and non-locking palmar plating for unstable distal radius fractures in elderly. Int Orthop 33:773–778CrossRef Scmelzer-Schmeid N, Wieloch P, Martini AK (2009) Comparison of external fixation, locking and non-locking palmar plating for unstable distal radius fractures in elderly. Int Orthop 33:773–778CrossRef
26.
Zurück zum Zitat Wei DW, Raizman NM, Bottino CJ et al (2009) Unstable distal radial fractures treated with external fixation, a radial column plate, or a volar plate. J Bone Jt Surg 91-A:1568–1577CrossRef Wei DW, Raizman NM, Bottino CJ et al (2009) Unstable distal radial fractures treated with external fixation, a radial column plate, or a volar plate. J Bone Jt Surg 91-A:1568–1577CrossRef
27.
Zurück zum Zitat Wilcke MK, Abbaszadegan H, Adolphson PY (2011) Wrist function recovers more rapidly after volar locked plating than after external fixation but the outcomes are similar after 1 year. Acta Orthop 82:76–81PubMedCrossRef Wilcke MK, Abbaszadegan H, Adolphson PY (2011) Wrist function recovers more rapidly after volar locked plating than after external fixation but the outcomes are similar after 1 year. Acta Orthop 82:76–81PubMedCrossRef
Metadaten
Titel
Retrospective comparison of external fixation versus volar locking plate in the treatment of unstable intra-articular distal radius fractures
verfasst von
Mert Kumbaraci
Levent Kucuk
Levent Karapinar
Cengizhan Kurt
Erhan Coskunol
Publikationsdatum
01.02.2014
Verlag
Springer Paris
Erschienen in
European Journal of Orthopaedic Surgery & Traumatology / Ausgabe 2/2014
Print ISSN: 1633-8065
Elektronische ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-012-1155-0

Weitere Artikel der Ausgabe 2/2014

European Journal of Orthopaedic Surgery & Traumatology 2/2014 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.