Abstract

A postoperative pseudoaneurysm is a rare complication that is difficult to diagnose. Computed tomography (CT) revealed a pseudoaneurysm in the ascending aorta of a 68-year-old female 8 days after mitral valve replacement and tricuspid annuloplasty. The defect was simply repaired during emergency surgery without cardiopulmonary bypass (CPB). The early detection of a postoperative pseudoaneurysm is important to avoid a second operation complicated by adhesions. Enhanced CT was useful for early detection in this patient. Pseudoaneurysm of the ascending aorta at the cannulation site can occur soon after surgery, and early recognition might allow simpler surgery without CPB.
Literatur
1.
Zurück zum Zitat Malvindi PG, van Putte BP, Heijmen RH, Schepens MA, Morshuis WJ. Reoperations for aortic false aneurysms after cardiac surgery. Ann Thorac Surg. 2010;90:1437–43.PubMedCrossRef Malvindi PG, van Putte BP, Heijmen RH, Schepens MA, Morshuis WJ. Reoperations for aortic false aneurysms after cardiac surgery. Ann Thorac Surg. 2010;90:1437–43.PubMedCrossRef
2.
Zurück zum Zitat Murayama H, Watanabe T, Kobayashi Y, Matsumura Y, Kobayashi A. Nonmycotic false aneurysm of aortic cannulation site presenting 26 years postoperatively. Ann Thorac Surg. 2009;87:936–9.PubMedCrossRef Murayama H, Watanabe T, Kobayashi Y, Matsumura Y, Kobayashi A. Nonmycotic false aneurysm of aortic cannulation site presenting 26 years postoperatively. Ann Thorac Surg. 2009;87:936–9.PubMedCrossRef
3.
Zurück zum Zitat Branchini B, Zingone B, Vaccari M. Ascending aortic false aneurysm following cannulation for perfusion. Thorax. 1976;31:234–7.PubMedCrossRef Branchini B, Zingone B, Vaccari M. Ascending aortic false aneurysm following cannulation for perfusion. Thorax. 1976;31:234–7.PubMedCrossRef
4.
Zurück zum Zitat Nakayama T, Saito T, Asano M, Nomura N, Mishima A. An aneurysm at the cannulation site discovered 40 years after cardiac surgery: report of a case. Ann Thorac Cardiovasc Surg. 2008;14:267–9.PubMed Nakayama T, Saito T, Asano M, Nomura N, Mishima A. An aneurysm at the cannulation site discovered 40 years after cardiac surgery: report of a case. Ann Thorac Cardiovasc Surg. 2008;14:267–9.PubMed
5.
Zurück zum Zitat Atik FA, Navia JL, Svensson LG, Vega PR, Feng J, Brizzio ME, Gillinov AM, Pettersson BG, Blackstone EH, Lytle BW. Surgical treatment of pseudoaneurysm of the thoracic aorta. J Thorac Cardiovasc Surg. 2006;132:379–85.PubMedCrossRef Atik FA, Navia JL, Svensson LG, Vega PR, Feng J, Brizzio ME, Gillinov AM, Pettersson BG, Blackstone EH, Lytle BW. Surgical treatment of pseudoaneurysm of the thoracic aorta. J Thorac Cardiovasc Surg. 2006;132:379–85.PubMedCrossRef
6.
Zurück zum Zitat Villavicencio MA, Orszulak TA, Sundt TM 3rd, Daly RC, Dearani JA, McGregor CG, Mullany CJ, Puga FJ, Zehr KJ, Schaff HV. Thoracic aorta false aneurysm: what surgical strategy should be recommended? Ann Thorac Surg. 2006;82:81–9. Villavicencio MA, Orszulak TA, Sundt TM 3rd, Daly RC, Dearani JA, McGregor CG, Mullany CJ, Puga FJ, Zehr KJ, Schaff HV. Thoracic aorta false aneurysm: what surgical strategy should be recommended? Ann Thorac Surg. 2006;82:81–9.
7.
Zurück zum Zitat Mohammadi S, Bonnet N, Leprince P, Kolsi M, Rama A, Pavie A, Gandjbakhch I. Reoperation for false aneurysm of the ascending aorta after its prosthetic replacement: surgical strategy. Ann Thorac Surg. 2005;79:147–52.PubMedCrossRef Mohammadi S, Bonnet N, Leprince P, Kolsi M, Rama A, Pavie A, Gandjbakhch I. Reoperation for false aneurysm of the ascending aorta after its prosthetic replacement: surgical strategy. Ann Thorac Surg. 2005;79:147–52.PubMedCrossRef
8.
Zurück zum Zitat Settepani F, Muretti M, Barbone A, Citterio E, Eusebio A, Ornaghi D, Silvaggio G, Gallotti R. Reoperation for aortic false aneurysms: our experience and strategy for safe resternotomy. J Card Surg. 2008;23:216–20.PubMedCrossRef Settepani F, Muretti M, Barbone A, Citterio E, Eusebio A, Ornaghi D, Silvaggio G, Gallotti R. Reoperation for aortic false aneurysms: our experience and strategy for safe resternotomy. J Card Surg. 2008;23:216–20.PubMedCrossRef
Metadaten
Titel
Pseudoaneurysm at the cannulation site of the ascending aorta arising 8 days postoperatively: report of a case
verfasst von
Tatsuya Ogawa
Koichi Toda
Tomoyuki Fujita
Masahiro Higashi
Junjiro Kobayashi
Publikationsdatum
01.05.2013
Verlag
Springer Japan
Erschienen in
Surgery Today / Ausgabe 5/2013
Print ISSN: 0941-1291
Elektronische ISSN: 1436-2813
DOI
https://doi.org/10.1007/s00595-012-0194-9

Weitere Artikel der Ausgabe 5/2013

Surgery Today 5/2013 Zur Ausgabe

Leitlinien kompakt für die Allgemeinmedizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Facharzt-Training Allgemeinmedizin

Die ideale Vorbereitung zur anstehenden Prüfung mit den ersten 24 von 100 klinischen Fallbeispielen verschiedener Themenfelder

Mehr erfahren

Neu im Fachgebiet Allgemeinmedizin

11.04.2024 | DGP 2024 | Kongressbericht | Nachrichten

COPD früher diagnostizieren – und dann?

09.04.2024 | Sexuell übertragbare Erkrankungen | Podcast | Nachrichten

Wer kümmert sich um STI bei Frauen?

mit Dr. med. Angela Schuster und Pauline Meurer, Institut für Allgemeinmedizin, Charité Berlin
In Kooperation mit:
Zeitschrift für Allgemeinmedizin, DEGAM

Update Allgemeinmedizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.